1.Efficacy and safety of cryoablation combined with Camrelizumab monoclonal antibody in treatment of hepatocellular carcinoma
Changwang ZHANG ; Ninghan WU ; Cong WANG ; Zheng ZHENG ; Siming GAO ; Changpeng ZOU ; Sujing ZHANG ; Na LI
Journal of Clinical Hepatology 2024;40(6):1169-1174
Objective To investigate the efficacy and safety of cryoablation combined with Camrelizumab monoclonal antibody in the treatment of hepatocellular carcinoma(HCC).Methods A total of 103 HCC patients who were admitted to our hospital from June 2020 to June 2023 were enrolled and randomly divided into combined treatment group with 53 patients and control group with 50 patients.The patients in the control group received percutaneous argon-helium cryoablation,and those in the combined treatment group received percutaneous argon-helium cryoablation combined with Camrelizumab monoclonal antibody.The two groups were compared in terms of short-term response,changes in T lymphocyte subsets after treatment,changes in liver function and alpha-fetoprotein(AFP)after treatment,and progression-free survival and overall survival during follow-up.The t-test was used for comparison of normally distributed continuous data between groups,and the chi-square test was used for comparison of categorical data between groups.The Kaplan-Meier method was used to plot survival curves,and the log-rank test was used for comparison of survival time between the two groups.Results The combined treatment group had significantly higher overall response rate and disease control rate than the control group(χ2=4.156 and 4.348,P=0.042 and 0.037).After treatment,the combined treatment group had significant increases in the percentages of CD3+and CD4+T lymphocytes and CD4+/CD8+ratio(P<0.05)and a significant reduction in the percentage of CD8+T lymphocytes(P<0.05),while the control group had no significant changes in T lymphocyte subsets after treatment(P>0.05),and compared with the control group after treatment,the combined treatment group had significantly higher percentages of CD3+and CD4+T lymphocytes and CD4+/CD8+ratio(all P<0.05)and a significantly lower percentage of CD8+T lymphocytes(P<0.05).After treatment,both groups had significant reductions in the levels of alanine aminotransferase(ALT),aspartate aminotransferase(AST),and AFP(all P<0.05)and a significant increase in the level of albumin(Alb)(P>0.05),and compared with the control group after treatment,the combined treatment group had significantly lower levels of ALT,AST,and AFP(all P<0.05)and a significantly higher level of Alb(P<0.05).There were no significant differences in the incidence rates of grade Ⅲ—Ⅳ(moderate to severe)adverse reactions between the two groups(P>0.05).Compared with the control group,the combined treatment group had significantly better median progression-free survival(21.32 months vs 15.31 months,χ2=4.689,P=0.030)and median overall survival(28.36 months vs 20.75 months,χ2=5.030,P=0.025).Conclusion Argon-helium cryoablation combined with Camrelizumab monoclonal antibody can effectively improve short-term response,enhance immune function,and prolong survival time,with a favorable safety profile.
2.The comparison of bladder neck descent and the hiatus area of levator ani between lithotomy position and separating-legs-holding-knees position
Xiufeng HUANG ; Jian ZHENG ; Qingjuan WANG ; Junyan CAO ; Qian LIANG ; Sujing WU ; Xinling ZHANG
Chinese Journal of Ultrasonography 2020;29(7):618-622
Objective:To investigate whether the bladder neck descent and the area of levator ani hiatus obtained on the maximum Valsalva were consistent at the lithotomy position and separating-legs-holding-knees position.Methods:Forty four subjects who underwent perineal pelvic floor four-dimensional ultrasound at 6-8 weeks postpartum in Third Hospital of Longgang Shenzhen from November 2019 to January 2020 were enrolled in this study. All subjects were able to effectively complete the maximum Valsalva maneuver both at the lithotomy position and the separating-legs-holding-knees position. The bladder neck descent and hiatus area of the levator Ani on the maximum Valsalva at these two positions were measured and compared.Results:The bladder neck descent at the separating-legs-holding-knees position was higher than that at the lithotomy position [(41.06±8.25)mm vs (39.96±8.10)mm; t=-2.965, P=0.005], and the hiatus area of levator Ani at the separating-legs-holding-knees position was larger than that at the lithotomy position[(27.55±4.90)cm 2 vs (26.32±4.76)cm 2; t=-3.820, P<0.001]. Conclusions:The bladder neck descent and the area of levator Ani hiatus on the maximum Valsalva at separating-legs- holding-knees position are larger than those on the maximum Valsalva at the lithotomy position.
3. Impact of hypertensive disorder complicating pregnancy on neonatal mortality and major complications in preterm infants
Meiyu WANG ; Xiangyong KONG ; Zhichun FENG ; Fengdan XU ; Hongyan LYU ; Lihong YANG ; Sujing WU ; Rong JU ; Jin WANG ; Li PENG ; Zhankui LI ; Xiaolin ZHAO ; Shujuan ZENG ; Huixian QIU ; Weixi WEN ; Hui WU ; Ying LI ; Nan LI ; Xuefeng ZHANG ; Wenzheng JIA ; Guo GUO ; Weipeng LIU ; Feng WANG ; Gaimei LI ; Fang LIU ; Wei LI ; Xiao-ying ZHAO ; Hongbin CHENG ; Yunbo XU ; Wenchao CHEN ; Huan YIN ; Yanjie DING ; Xiaoliang WANG ; Ruiyan SHAN ; Ping XU ; Meiying HAN ; Chunyan YANG ; Tieqiang CHEN ; Xiaomei TONG ; Shaojun LIU ; Ziyuan LIU
Chinese Journal of Applied Clinical Pediatrics 2018;33(14):1065-1070
Objective:
To investigate the effect of hypertensive disorder complicating pregnancy (HDCP) on the mortality and early complications of premature infants.
Methods:
The general clinical data of preterm infants with gestational age 24-36+ 6 weeks were collected from the cooperative units in the task group from January 1, 2013 to December 31, 2014.According to the severity of HDCP, the infants were divided into 4 groups: HDCP group, preeclampsia group, eclampsia group and non HDCP group, the mortality and major complications of preterm infants were compared, and the influencing factors were analyzed.
Results:
The mortality rate of preterm in the HDCP group was significantly higher than that of non HDCP group, and there was statistical significance (
4.Biomonitoring of 33 Elements in Blood and Urine Samples from Coastal Popula-tions in Sanmen County of Zhejiang Province
Sujing ZHANG ; Ruxin LUO ; Dong MA ; Xianyi ZHUO
Journal of Forensic Medicine 2016;32(2):114-118
Objective To determ ine the norm al reference values of 33 elem ents, Ag, Al, As, Au, B , B a, Be, Ca, Cd, Co, Cr, Cs, Cu, Fe, G a, H g, Li, Mg, Mn, Mo, N i, Pb, Rb, Sb, Se, Sr, Th, Ti, Tl, U , V , Zn and Zr, in the blood and urine sam ples from the general population in Sanm en County of Zhejiang province, a typical coastal area of eastern China. Methods The 33 elem ents in 272 blood and 300 urine sam ples w ere determ ined by inductively coupled plasm a-m ass spectrom etry (ICP-MS ). The norm ality test of data w as conducted using SPSS 17.0 Statistics.The data w as com pared w ith other reports. Results The norm al reference values of the 33 elem ents in the blood and urine sam ples from the general population in Sanm en County w ere obtained, w hich of som e elem ents w ere found to be sim ilar w ith other reports, such as Co, Cu, Mn and Sr, w hile As, Cd, H g and Pb w ere generally found to be higher than those previously reported. There w as a w ide variation betw een the reports from different countries in blood B a. Conclusion The norm al reference values of the 33 elem ents in the blood and urine sam ples from the general population in Sanm en County are established, and successfully applied to tw o poisoning cases.
5.Normal Range of 33 Elements in Blood Samples from General Population in Hu-nan Province
Yao WANG ; Sujing ZHANG ; Yuejin WANG ; Xianyi ZHUO
Journal of Forensic Medicine 2015;(2):117-122
Objective T o determine the normal range of the 33 elements (Li, Be, B, mg, Al, Ca, Ti, V , Cr, mn, Fe, Co, Ni, Cu, Zn, Ga, As, Se, Rb, Sr, Zr, mo, Ag, Cd, Sb, Cs, Ba, Au, Hg, Tl, Pb, Th and U ) in human whole blood of general population in Hunan province. Methods Blood samples were ana-lyzed by inductively coupled plasma-mass spectrometry (ICP-mS ) to determine the normal range. T he influences of district, gender and age to the element content in blood samples were also observed. Re-sults T he normal range of 33 elements in blood samples fromgeneral population in Hunan province were obtained. Gender was shown to statistically influence the concentrations of B, mg, Ca, Ti, mn, Fe, Co, Cu, Zn, As, Se, Rb, Sr, Ag, Cd, Cs, Hg and Pb (P<0.05), while age was shown to influence the concentrations of Co, Ni, Cs and Hg in women (P<0.05) as well as Cu, Se and Hg in men(P<0.05). Conclusion Although there are variables in different districts, the normal ranges of trace element in blood of the four cities in Hunan province are established.
6.Study of building up a comprehensive system for predicting difficult laryngeal exposure under suspension laryngoscopy.
Hongqiang ZHANG ; Sujing TIAN ; Guoqing YANG ; Xiaoming LI
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2015;29(16):1471-1473
OBJECTIVE:
To build up a simple and effective comprehensive system for predicting difficult laryngeal exposure under suspension laryngoscopy.
METHOD:
One hundred and twenty cases of laryngeal tubor were selected. Using Logistic regression method to analyse relative factors, including weight, height, BMI, neck girth, neck upward degree, upper-lower incisor teeth distance, thyroid-mentum distance, thyroid-sternum distance, Mallampati test, Yamamoto test and Upper lip bite test. Build data-base to construct a comprehensive system for predicting difficult laryngeal exposure under suspension laryngoscopy.
RESULT:
The relative factors of difficult laryngeal exposure were BMI, neck girth, upper-lower incisor teeth distance, neck upward degree, thyroid-mentum distance, Mallampati test and Yamamoto test (P < 0.05). To build up a comprehensive system for predicting difficult laryngeal exposure under suspension laryngoscopy. The predicting standards included the seven relative factors, each factor has 1 score, 2 score, 3 score. Higher score means more risk. Eight score was designed as minimum, under the premise,the sensibility, misdiagnosis rate, missed misdiagnosis rate, specificity of the experiment were 95.5%, 5.3%, 4.5%, 94.7%.
CONCLUSION
The comprehesive system is an effective method for predicting difficult intubation. It can help to identify difficult cases according to the results of this predicting system.
Anthropometry
;
Chin
;
Humans
;
Intubation, Intratracheal
;
methods
;
Laryngoscopy
;
methods
;
Larynx
;
Lip
;
Neck
;
Thyroid Gland
7.Study on establishing a project concerning the process quality control of treating liver cancer with CyberKnife.
Huijun XU ; Yu LI ; Sujing ZHANG ; Xiao YANG ; Junhua ZHANG
Journal of Biomedical Engineering 2014;31(2):298-301
In order to guarantee the safety and accuracy of the whole treating process as well as better link up of each section during the treatment, we did research in order to establish a project concerning the process quality control (PQC) of treating liver cancer with CyberKnife. From the safety and accuracy point of view, we divided the whole process of treating liver cancer with CyberKnife into ten links, i.e. the registration of patients' information, the im plantation of fiducial markers, fixation of body posture, CT localization, target delineation, design of the treatment plan, quality assurance in physics, implementation of the treatment plan, inspection on the correctness and data archiving. We analyzed the possible mistakes in each link and the consequences brought by them. To smoothly connect all the links, a special part "Attention" was added between every two links. Various wrong operations which may influence the safety and accuracy of treatment were illustrated, and the consequences brought by them were also ex plained. The "Attention" part among links offers important information for the next step, and gives us reminding and warnings. The project of quality control covers all the important links when treating liver cancer with Cy berKnife. It offers regulations, reminding and warning for us so that the safety and accuracy of treatment can be guaranteed, and the work of all staff could be closely connected.
Humans
;
Liver Neoplasms
;
surgery
;
Quality Control
;
Radiosurgery
;
methods
8.Comparison of the effect of three cryoprotectants on vitrification-cryopreservation of mouse epididymis
Miao LI ; Lili YU ; Yibao ZHANG ; Sujing QIANG ; Lijun LIU ; Ping XU
Acta Laboratorium Animalis Scientia Sinica 2014;(2):62-65
Objective To compare the effect of three cryoprotectants on vitrification-cryopreservation of C57BL/6J mouse epididymis.Method Epididymises from 6-8-week old male C57BL/6J mice (age) were cryopreserved using DMSO, PROH and R18S3 cryoprotectant solution and thawed , respectively.The morphology of sperm from thawed epididy-mis, the rate of post-thawing survival and reproductive capacity were determined to evaluate the freezing efficiency of the three cryoprotectants .Results The sperms from thawed epididymis of the three groups were all well-preserved structural-ly.The survival rate of sperms was 88.17%, 61.17% and 16.83% in the PROH, DMSO and R18S3 cryoprotectant solu-tions, respectively, and there were significant differences between the three cryopreservation groups (P<0.05 for all). The number of pups from the DMSO , PROH and R18S3 groups were 13, 8 and 17 mice after ICSI and embryo implantation , respectively.Conclusions All the three cryoprotectants DMSO , PROH and R18S3 solutions are suitable for vitrification-cryopreservation of C57BL/6J mouse epididymis.But PROH is the preference of these cryoprotectant solutions .
9.Effect of different transplantation sites on the outcome of testicular grafts in mice
Yibao ZHANG ; Miao LI ; Lili YU ; Sujing QIANG ; Lijun LIU ; Ping XU ; Rong RUI
Acta Laboratorium Animalis Scientia Sinica 2014;(4):56-59
Objective To compare the effects of different transplantation sites on the outcome of testicular grafts in mice, and to provide a basis for development and application of this technique in relevant research .Method 5-day old and 4-week old SPF male C57BL/6J mice were used in this study .Three groups of testicular transplantation , i.e.dorsal subcutaneous transplantation ( 5 mice, 40 testes ) , transplantation inside the testicular tunica albuginea ( 6 mice, 12 testes), and were subrenal capsule transplantation (10 mice,15 testes) groups were set up for evaluating the effect of transplantation site on the outcomes in mice .Sham operation (4 mice) and castration (4 mice) groups were also used in this study.The mice were sacrificed at 8 weeks after transplantation and the transplanted testes were collected for analysis of their weight, transplant survival, weight gain, and germ cell differentiation.Results There were significant differences of the testicular germ cell differentiation in different transplantation groups .The germ cell differentiation was best in the in-tra-tunica albuginea transplantation group , and were similar to that in the sham operation group .The germ cell differentia-tion rate was 100%in the intra-tunica albuginea transplantation group , 29.2% in the subcutaneous transplantation group and 0%in the subrenal capsule transplantation group .Conclusions Transplantation beneath the testicular tunica albug-inea is the most favorable site for germ cell differentiation , and dorsal subcutaneous transplantation is an alternative choice . Subrenal capsule transplantation is not appropriate for preservation of male reproductive organs in mice .
10.Research on the capability test and evaluation of the QuickCheck's accelerator
Yu LI ; Huijun XU ; Sujing ZHANG
China Medical Equipment 2013;(12):19-21
Objective:To give the test in cases of changing the conditions of measurement and reference value, compare the test results, and detect the capacity of QuickCheck, so as to offer reference for the daily morning check of accelerator and the evaluation of test results. Methods:Change the output dose, field size, SSD, angle of collimator and gantry angle of the accelerator, and then evaluate QuickCheck’s capacity of monitoring accelerator accordingly. Compare the field parameters measured by QuickCheck with the data from the 3D water tank. Results:When the output dose was 1 cGy higher than the reference value or 6 cGy lower than it, the field size expanded or contracted more than 2 cm simutaneouly, SSD was 2 cm higher or 1 cm lower than reference value, the collimator rotated more than 2 °, the gantry angle rotated more than 6 °, and then the test results of QuickCheck surpassed threshold. Comparing the measuring results of QuickCheck with 3D water tank, the difference between the flatness of the two was 3.84%, symmetry (G/T) 0.67%, symmetry (L/R) 0.47%and dose rate 1.2 MU/min. Conclusion:QuickCheck is rather accurate in testing the output dose, field size, angle of collimator, flatness, symmetry and dose rate, so it could meet the requirement of accelerator’s daily QA. However, its capability is relatively poor on examining SSD and the deviation of gantry angle.