1.Graphite furnace atomic absorption spectrometry for the determination of trace gallium in whole blood.
Chinese Journal of Industrial Hygiene and Occupational Diseases 2022;40(10):776-778
Objective: To establish a graphite furnace atomic absorption spectrometry method for the determination of trace gallium in whole blood. Methods: From January to May 2021, the five factors of ashing temperature, ashing time, atomization temperature, atomization time and matrix modifier concentration in the determination of gallium in whole blood by graphite furnace atomic absorption spectrometry were optimized by using L(16) (4(5)) orthogonal test design. At the same time, within-run, between-run, spiking recovery test and other methodological indicators were tested. Results: Under the optimized detection conditions, the linear range of determination of gallium in whole blood by graphite furnace atomic absorption spectrometry was 0.29-100.00 μg/L (r=0.9991) . The within-run and between-run relative standard deviations (RSD) of repetitive measurement at 10.0, 50.0, 80.0 μg/L concentration levels were 2.3%-4.4% and 1.5%-3.6%, the recovery rate of spiking was 98.1%-103.8%, and the detection limit of the method was 0.13 μg/L. Conclusion: Graphite furnace atomic absorption spectrometry for the determination of trace gallium in whole blood is easy to operate, has a wide linear range, low detection limit, accurate and reliable results, which is suitable for occupational health examinations and the determination of acute gallium poisoning.
Spectrophotometry, Atomic/methods*
;
Graphite/chemistry*
;
Gallium
;
Limit of Detection
;
Temperature
2.Research progress on identification and quality evaluation of glues medicines.
Hui-Hu LI ; Gang REN ; Li-Min CHEN ; Guo-Yue ZHONG
China Journal of Chinese Materia Medica 2018;43(1):15-20
Glues medicines is a special kind of traditional Chinese medicine.As the market demand is large, the raw materials are in short supply and lacks proper quality evaluation technology, which causes inconsistent quality of products on the market. Its authentic identification and evaluation stay a problem to be solved. In this paper, the research progress of the methods and techniques of the evaluation of the identification and quality of glues medicines were reviewed. The researches of medicinal glue type identification and quality evaluation mainly concentrated in four aspects of medicinal materials of physical and chemical properties, trace elements, organic chemicals and biological genetic methods and techniques. The methods of physicochemical properties include thermal analysis, gel electrophoresis, isoelectric focusing electrophoresis, infrared spectroscopy, gel exclusion chromatography, and circular dichroism. The methods including atomic absorption spectrometry, X-ray fluorescence spectrometry, plasma emission spectrometry and visible spectrophotometry were used for the study of the trace elements of glues medicines. The organic chemical composition was studied by methods of composition of amino acids, content detection, odor detection, lipid soluble component, organic acid detection. Methods based on the characteristics of biogenetics include DNA, polypeptide and amino acid sequence difference analysis. Overall, because of relative components similarity of the glues medicines (such as amino acids, proteins and peptides), its authenticity and quality evaluation index is difficult to judge objectively, all sorts of identification evaluation methods have different characteristics, but also their limitations. It indicates that further study should focus on identification of evaluation index and various technology integrated application combining with the characteristics of the production process.
Adhesives
;
Drugs, Chinese Herbal
;
Medicine, Chinese Traditional
;
Quality Control
;
Spectrophotometry, Atomic
;
Trace Elements
3.Lead, Mercury, and Cadmium Exposure in the Korean General Population
Sang Yong EOM ; Young Sub LEE ; Seul Gi LEE ; Mi Na SEO ; Byung Sun CHOI ; Yong Dae KIM ; Ji Ae LIM ; Myung Sil HWANG ; Ho Jang KWON ; Yu Mi KIM ; Young Seoub HONG ; Seok Joon SOHN ; Kyung Su PARK ; Hee Soo PYO ; Ho KIM ; Heon KIM ; Jung Duck PARK
Journal of Korean Medical Science 2018;33(2):e9-
BACKGROUND: Lead (Pb), mercury (Hg), and cadmium (Cd) are well-known environmental pollutants. They are unnecessary in the biological processes of humans. This study was performed to estimate the representative background exposure levels to the metals by measuring concentrations in whole blood of the Korean general population. METHODS: This population-based cross-sectional study included 4,000 subjects (1,886 males and 2,114 females) 0–83 years of age in 2010 and 2011. Adult subjects (≥ 19 years of age) were collected by sex- and age-stratified probability method, and preschool- and school-aged subjects were recruited by a cluster sampling method. Written consent was provided prior to blood sampling. Pb and Cd blood concentrations were determined by a flameless atomic absorption spectrophotometry, and blood Hg was analyzed by a direct Hg analyzer. RESULTS: The geometric mean, median and 95th percentile of blood Pb was 1.82 µg/dL, 1.83 µg/dL, and 3.78 µg/dL, respectively. The respective values were 2.92 µg/L, 2.87 µg/L, 9.12 µg/L for Hg, and 0.56 µg/L, 0.59 µg/L, 2.20 µg/L for Cd. Blood Pb and Hg were higher in males than in females, but no sex difference was observed, respectively, in subjects 0–4 years of age for Pb and in subjects less than 20 years for Hg. However, blood Cd was higher in females than in males and no sex difference was observed in subjects < 30 years of age. CONCLUSION: This study provides representative data of human exposure to Pb, Hg, and Cd covering whole age groups of the general population in Korea.
Adult
;
Biological Processes
;
Cadmium
;
Cross-Sectional Studies
;
Environmental Pollutants
;
Female
;
Humans
;
Korea
;
Male
;
Metals
;
Methods
;
Sex Characteristics
;
Spectrophotometry, Atomic
4.Investigations on the effects of mouthrinses on the colour stability and surface roughness of different dental bioceramics.
Koray SOYGUN ; Osman VAROL ; Ali OZER ; Giray BOLAYIR
The Journal of Advanced Prosthodontics 2017;9(3):200-207
PURPOSE: In this study, three bioceramic materials, [IPS Empress CAD (Ivoclar), IPS e.max CAD (Ivoclar), and Lava Ultimate CAD (3M ESPE)] were treated with three commercial mouthrinses [Listerine, Tantum Verde, and Klorhex]; and changes in colour reflectance and surface roughness values were then quantitatively assessed. MATERIALS AND METHODS: One hundred and twenty ceramic samples, with dimensions of 2 × 12 × 14 mm, were prepared and divided into nine sample groups, except three control samples. The samples were immersed in the mouthrinse solutions for 120 hrs, and changes in colour reflectance and surface roughness values were measured by UV light spectrophotometry (Vita Easyshade; VITA Zahnfabrik) and by profilometer device (MitutoyoSurftest SJ-301), respectively. The change of surface roughness was inspected by Scanning Electron Microscopy (SEM) and Atomic Force Microscopy (AFM). RESULTS: There was a positive correlation between the ΔE and increase in the surface roughness. Two of the ceramic materials, IPS Empress and Lava Ultimate, were affected significantly by the treatment of the mouthrinse solutions (P<.05). The most affecting solution was Tantum Verde and the most affected material was Lava Ultimate. As expected, the most resistant material to ΔE and chemical corrosion was IPS e max CAD among the materials used. CONCLUSION: This work implied that mouthrinse with lower alcohol content had less deteriorating effect on colour and on the surface morphology of the bioceramic materials.
Benzydamine
;
Ceramics
;
Corrosion
;
Microscopy, Atomic Force
;
Microscopy, Electron, Scanning
;
Refractometry
;
Spectrophotometry
;
Ultraviolet Rays
5.Occupational Lead Exposure from Indoor Firing Ranges in Korea.
Won Ju PARK ; Suk Ho LEE ; Se Ho LEE ; Hye Sik YOON ; Jai Dong MOON
Journal of Korean Medical Science 2016;31(4):497-501
Military personnel often use ammunitions that contain lead. The present study aimed to identify the risks for lead exposure and lead poisoning among workers at indoor firing ranges. A special health examination, including blood lead level (BLL) testing, was performed for all 120 workers at the indoor firing ranges of the Republic of Korea's Air Force, Navy, and Armed Forces Athletic Corps. The overall mean BLL was 11.3 ± 9.4 µg/dL (range: 2.0-64.0 µg/dL). The arithmetic mean of the BLL for professional shooters belong to Armed Forces Athletic Corps was 14.0 ± 8.3 µg/dL, while those of shooting range managers and shooting range supervisors were 13.8 ± 11.1 µg/dL and 6.4 ± 3.1 µg/dL, respectively. One individual had a BLL of 64 µg/dL, and ultimately completed chelation treatment (with CaNa2-ethylenediaminetetraacetic acid) without any adverse effects. These findings indicate that indoor firing range workers are exposed to elevated levels of lead. Therefore, when constructing an indoor firing range, a specialist should be engaged to design and assess the ventilation system; and safety guidelines regarding ammunition and waste handling must be mandatory. Moreover, workplace environmental monitoring should be implemented for indoor firing ranges, and the workers should undergo regularly scheduled special health examinations.
Adult
;
Air Pollutants/*blood
;
Air Pollution, Indoor
;
Drinking
;
Edetic Acid/chemistry
;
Female
;
Firearms
;
Humans
;
Lead/*blood/chemistry
;
Male
;
Military Personnel
;
Occupational Exposure/*analysis
;
Odds Ratio
;
Republic of Korea
;
Risk Factors
;
Spectrophotometry, Atomic
;
Young Adult
6.Environmental Exposure to Arsenic, Lead, and Cadmium in People Living near Janghang Copper Smelter in Korea.
Yong Dae KIM ; Sang Yong EOM ; Dong Hyuk YIM ; In Soo KIM ; Hee Kwan WON ; Choong Hee PARK ; Guen Bae KIM ; Seung Do YU ; Byung Sun CHOI ; Jung Duck PARK ; Heon KIM
Journal of Korean Medical Science 2016;31(4):489-496
Concentrations of heavy metals exceed safety thresholds in the soil near Janghang Copper Refinery, a smelter in Korea that operated from 1936 to 1989. This study was conducted to evaluate the level of exposure to toxic metals and the potential effect on health in people living near the smelter. The study included 572 adults living within 4 km of the smelter and compared them with 413 controls group of people living similar lifestyles in a rural area approximately 15 km from the smelter. Urinary arsenic (As) level did not decrease according to the distance from the smelter, regardless of gender and working history in smelters and mines. However, in subjects who had no occupational exposure to toxic metals, blood lead (Pb) and cadmium (Cd) and urinary Cd decreased according to the distance from the smelter, both in men and women. Additionally, the distance from the smelter was a determinant factor for a decrease of As, Pb, and Cd in multiple regression models, respectively. On the other hands, urinary Cd was a risk factor for renal tubular dysfunction in populations living near the smelter. These results suggest that Janghang copper smelter was a main contamination source of As, Pb, and Cd, and populations living near the smelter suffered some adverse health effects as a consequence. The local population should be advised to make efforts to reduce exposure to environmental contaminants, in order to minimize potential health effects, and to pay close attention to any health problems possibly related to toxic metal exposure.
Acetylglucosaminidase/urine
;
Adult
;
Aged
;
Arsenic/*urine
;
Bone Density
;
Cadmium/*blood
;
Case-Control Studies
;
Chemical Industry
;
Creatinine/urine
;
*Environmental Exposure
;
Environmental Pollutants/*analysis/blood/urine
;
Female
;
Humans
;
Lead/*blood
;
Male
;
Middle Aged
;
Regression Analysis
;
Republic of Korea
;
Spectrophotometry, Atomic
7.Determination of residual aluminium Ion in Huoxiang Zhengqi pellets by GFAAS with EDTA complexation extraction.
Xue-Na WANG ; Cong-Cong RAN ; Qing-Lian LI ; Chao-Hui DU ; Ye JIANG
China Journal of Chinese Materia Medica 2015;40(12):2345-2348
To establish an EDTA complexation extraction pretreatment combining with GFAAS method for the determination of residual aluminium ion in Huoxiang zhengqi pellets without digestive treatment, systematical investigation was made on sample preparation, and EDTA was used for the complexation extraction of residual aluminium ion in samples. The pH, concentration and volume of extraction solution, the temperature and time of microwave extraction, and graphite furnace temperature program were investigated. The results were compared with the microwave digestion. It was showed that, 0.1 g of sample weight was added in 20 mL 0.05 mol x L(-1) EDTA solution (pH 3.5), followed by heating at 150 degrees C for 10 min in the microwave extraction device. The determination of GFAAS was performed at optimized detection wavelength (257.4 nm) as well as graphite furnace temperature program, the detection limits and quantification limits were 2.37 μg x L(-1) and 7.89 μg x L(-1), respectively. The precision (RSD) was less than 2.3%. The average recovery was 96.9% -101%. The present method is easy, rapid and accurate for the determination of residual aluminium ion in Huoxiang zhengqi pellets.
Aluminum
;
chemistry
;
isolation & purification
;
Drug Contamination
;
Drugs, Chinese Herbal
;
chemistry
;
Edetic Acid
;
chemistry
;
Graphite
;
chemistry
;
Spectrophotometry, Atomic
;
methods
;
Temperature
8.Determination of indium in whole blood by graphite furnace atomic absorption spectrometry.
Juntao HE ; Fen LIU ; Yingping XIANG ; Zhimin LI ; E-mail: LIZHIMIN567@SINA.COM.
Chinese Journal of Industrial Hygiene and Occupational Diseases 2015;33(8):627-629
OBJECTIVETo investigate the sensitization effect of different chemical modifiers in the determination of indium in whole blood by graphite furnace atomic absorption spectrometry, and to develop a new method for the determination of indium in whole blood.
METHODSA mixture of 0.3% HNO3 (V/V) + 0.1% Triton X-100 (V/V) was used as a diluent, and a solution of 1 000 µg/ml Pd (NO3)2 + 3 000 µg/ml Mg (NO3)2 was used as modifier. After being diluted five times, the concentration of indium of the blood was directly determined by graphite furnace atomic absorption spectrometry.
RESULTSThe detection limit of the method was 0.33 µg/L, the linear range was 0.33~100.00 µg/L, the relative standard deviation was 1.43%~2.65%, and the recovery rate was 98.3%~105.3%.
CONCLUSIONThe method is simple and fast and has high recovery and precision, and it is suitable for the determination of indium in whole blood.
Blood Chemical Analysis ; instrumentation ; Graphite ; Humans ; Indium ; blood ; Limit of Detection ; Spectrophotometry, Atomic ; methods
9.Determination of stannum in urine by graphite furnace atomic absorption spectrometry.
Jiu CHEN ; Shihua WU ; Guanhao GUO ; Yimin LIU
Chinese Journal of Industrial Hygiene and Occupational Diseases 2015;33(12):924-926
OBJECTIVETo establish the method of graphite furnace atomic absorption spectrometry for the measurement of stannum in urine with calcium nitrate as the matrix modifier.
METHODSGraphite tube was pretreated with calcium nitrate as the matrix modifier, the urine sample was diluted with 1% nitric acid and then direct injection was performed for these samples, and graphite furnace atomic absorption spectrometry was applied for measurement.
RESULTSThe concentration of stannum in urine showed a good linear relationship within the range of 8.0~40.0 μg/L, with a correlation coefficient of 0.9981. The minimum detectable concentration was 0.72 μg/L, the degree of precision was 1.54%~6.69%, and the recovery rate was 99.23%~107.63%.
CONCLUSIONThis method can determine the content of stannum in urine accurately and rapidly, with a high sensitivity and a low cost.
Graphite ; Humans ; Spectrophotometry, Atomic ; Tin ; urine
10.Evaluation of uncertainty for determination of tin and its compounds in air of workplace by flame atomic absorption spectrometry.
Qiuning WEI ; Yuan WEI ; Fangfang LIU ; Yalei DING
Chinese Journal of Industrial Hygiene and Occupational Diseases 2015;33(10):782-783
OBJECTIVETo investigate the method for uncertainty evaluation of determination of tin and its compounds in the air of workplace by flame atomic absorption spectrometry.
METHODSThe national occupational health standards, GBZ/T160.28-2004 and JJF1059-1999, were used to build a mathematical model of determination of tin and its compounds in the air of workplace and to calculate the components of uncertainty.
RESULTSIn determination of tin and its compounds in the air of workplace using flame atomic absorption spectrometry, the uncertainty for the concentration of the standard solution, atomic absorption spectrophotometer, sample digestion, parallel determination, least square fitting of the calibration curve, and sample collection was 0.436%, 0.13%, 1.07%, 1.65%, 3.05%, and 2.89%, respectively. The combined uncertainty was 9.3%.The concentration of tin in the test sample was 0.132 mg/m³, and the expanded uncertainty for the measurement was 0.012 mg/m³ (K=2).
CONCLUSIONThe dominant uncertainty for determination of tin and its compounds in the air of workplace comes from least squares fitting of the calibration curve and sample collection. Quality control should be improved in the process of calibration curve fitting and sample collection.
Air Pollutants, Occupational ; analysis ; Models, Theoretical ; Spectrophotometry, Atomic ; Tin ; analysis ; Uncertainty ; Workplace

Result Analysis
Print
Save
E-mail