1.Effectiveness of comprehensive rhinoplasty on secondary nasal deformity with saddle nasal deformity after cleft lip surgery.
Ming CHEN ; Zongke GUO ; Bing YU
Chinese Journal of Reparative and Reconstructive Surgery 2024;38(1):56-61
OBJECTIVE:
To investigate the effectiveness of comprehensive rhinoplasty with autogenous costal cartilage grafting and prosthesis augmentation rhinoplasty in the treatment of secondary nasal deformity with saddle nasal deformity after cleft lip surgery.
METHODS:
The clinical data of 96 patients with secondary nasal deformity with saddle nasal deformity after cleft lip surgery between September 2008 and January 2019 were retrospectively analyzed. There were 17 males and 79 females with an average age of 25.6 years (range, 17-38 years). Autogenous costal cartilage grafts were used to construct stable nasal tip framework and enhance the strength of alar cartilage. Nasal dorsum prostheses (39 cases of bulge, 45 cases of silicone prosthesis) or autogenous costal cartilage (12 cases) were used for comprehensive rhinoplasty. Visual analogue scale (VAS) score was used to evaluate the postoperative satisfaction subjectively, and nasal alar height symmetry index, nasal alar width symmetry index, nasal dorsum central axis deviation angle, and nasal columella deviation angle were calculated to evaluate objectively before and after operation.
RESULTS:
All patients were followed up 6 months to 8 years, with an average of 13.4 months. Nasal septal hematoma occurred in 3 patients after operation, which was improved after local aspiration and nasal pressure packing. Two cases had mild deformation of the rib cartilage graft of the nasal dorsum, one of which had no obvious deviation of the nasal dorsum and was not given special treatment, and one case underwent the cartilage graft of the nasal dorsum removed and replaced with silicone prosthesis. The incisions of the other patients healed by first intention, and there was no complication such as postoperative infection and prosthesis displacement. The nasal alar height symmetry index, nasal alar width symmetry index, nasal dorsum central axis deviation angle, and nasal columella deviation angle significantly improved after operation when compared with preoperative ones ( P<0.05). Postoperative subjective satisfaction evaluation reached the level of basic satisfaction or above, and most of them were very satisfied.
CONCLUSION
Comprehensive rhinoplasty using autologous rib cartilage grafting to construct a stable nasal tip support, combined with dorsal nasal prosthesis or autologous cartilage implantation, can achieve good effectiveness on secondary nasal deformity with saddle nasal deformity after cleft lip surgery.
Male
;
Female
;
Humans
;
Adult
;
Rhinoplasty
;
Cleft Lip/surgery*
;
Retrospective Studies
;
Nose/surgery*
;
Nasal Septum/surgery*
;
Nasal Cartilages/surgery*
;
Silicones
;
Treatment Outcome
2.Embedded 3D printing of porous silicon orbital implants and its surface modification.
Hong ZHAO ; Yilin WANG ; Yanfang WANG ; Haihuan GONG ; Feiyang YINJUN ; Xiaojun CUI ; Jiankai ZHANG ; Wenhua HUANG
Journal of Southern Medical University 2023;43(5):783-792
OBJECTIVE:
To prepare customized porous silicone orbital implants using embedded 3D printing and assess the effect of surface modification on the properties of the implants.
METHODS:
The transparency, fluidity and rheological properties of the supporting media were tested to determine the optimal printing parameters of silicone. The morphological changes of silicone after modification were analyzed by scanning electron microscopy, and the hydrophilicity and hydrophobicity of silicone surface were evaluated by measuring the water contact angle. The compression modulus of porous silicone was measured using compression test. Porcine aortic endothelial cells (PAOECs) were co-cultured with porous silicone scaffolds for 1, 3 and 5 days to test the biocompatibility of silicone. The local inflammatory response to subcutaneous porous silicone implants was evaluated in rats.
RESULTS:
The optimal printing parameters of silicone orbital implants were determined as the following: supporting medium 4% (mass ratio), printing pressure 1.0 bar and printing speed 6 mm/s. Scanning electron microscopy showed that the silicone surface was successfully modified with polydopamine and collagen, which significantly improved hydrophilicity of the silicone surface (P < 0.05) without causing significant changes in the compression modulus (P > 0.05). The modified porous silicone scaffold had no obvious cytotoxicity and obviously promoted adhesion and proliferation of PAOECs (P < 0.05). In rats bearing the subcutaneous implants, no obvious inflammation was observed in the local tissue.
CONCLUSION
Poprous silicone orbital implants with uniform pores can be prepared using embedded 3D printing technology, and surface modification obviously improves hydrophilicity and biocompatibility of the silicone implants for potential clinical application.
Animals
;
Rats
;
Swine
;
Silicon
;
Orbital Implants
;
Endothelial Cells
;
Porosity
;
Silicones
;
Printing, Three-Dimensional
4.Retinal Toxicity Following the Injection Ganciclovir into Silicone Oil-filled Eye to Treat Acute Retinal Necrosis
Yeon Ji JO ; Seung Kwon CHOI ; Sun Ho PARK ; Jae Jung LEE ; Ji Eun LEE ; Sung Who PARK
Journal of the Korean Ophthalmological Society 2020;61(1):111-115
PURPOSE: To report a case of retinal toxicity after an intravitreal ganciclovir injection to treat acute retinal necrosis in an eye filled with silicone oil.CASE SUMMARY: A 56-year-old male presented with ocular pain and visual loss in his right eye. His best-corrected visual acuity was 20/25, inflammatory cells in the anterior chamber, multiple retinitis lesions and retinal vessel occlusions in the peripheral retina and vitreous opacity were showed. Acute retinal necrosis was suspected, anterior chamber polymerase chain reaction (PCR) test was done. Aciclovir 2,400 mg/day intravenously and ganciclovir 2.0 mg were administered by intravitreal injection. After 4 days, retinitis was worsened and PCR test was positive for varicella zoster virus. Ganciclovir intravitreal injections were increased twice a week. After 16 days, retinal detachment occurred, so scleral encircling, vitrectomy, laser photocoagulation, and silicone oil tamponade were conducted. Ganciclovir 1.0 mg was injected at the end of surgery. The patient's visual acuity decreased to hand motion, and multiple crystal deposits with multiple retinal hemorrhages were observed in the right eye the next day. Visual acuity did not recover and optical coherent tomography showed that the macula was thinned.CONCLUSIONS: Visual loss seemed to be related with the retinal toxicity of ganciclovir. The increased local concentration due to the silicone oil tamponade is thought to have caused the toxicity.
Acyclovir
;
Anterior Chamber
;
Ganciclovir
;
Hand
;
Herpesvirus 3, Human
;
Humans
;
Intravitreal Injections
;
Light Coagulation
;
Male
;
Middle Aged
;
Polymerase Chain Reaction
;
Retina
;
Retinal Detachment
;
Retinal Hemorrhage
;
Retinal Necrosis Syndrome, Acute
;
Retinal Vessels
;
Retinaldehyde
;
Retinitis
;
Silicon
;
Silicones
;
Visual Acuity
;
Vitrectomy
5.Comparison of the diagnostic yield of various systematic randomized prostate biopsy protocols using prostate phantoms made of devil's tongue jelly.
Ultrasonography 2019;38(1):44-49
PURPOSE: The purpose of this study was to compare the diagnostic yield of five systematic randomized protocols using 12–20 biopsy cores with variably-sized phantoms. METHODS: A total of 100 prostate phantom models were produced by casting liquid devil's tongue jelly using silicone molds. Sets of 20 phantoms were created with the following volumes: 20 mL, 40 mL, 60 mL, 80 mL, and 100 mL. Three focal lesions were created by injecting 0.5 mL of warm agar solution stained with red, blue, and green ink into each phantom model. The focal lesions were verified by ultrasonography. The systematic randomized biopsy protocols consisted of 12, 14, 16, 18, and 20 biopsy cores. The diagnostic yield of the multiple systematic biopsy protocols was compared. RESULTS: The overall detection rates of each model set were 93.3% for 20 mL, 88.3% for 40 mL, 71.7% for 60 mL, 43.3% for 80 mL, and 30.0% for 100 mL. Statistically significant differences in the detection rate were found between 40 mL and 60 mL and between 60 mL and 80 mL. No statistically significant increase in the detection rate was observed within a given volume set even when the number of core biopsies increased from 12 to 20. CONCLUSION: The diagnostic yield of systematic randomized biopsies is inversely proportional to the phantom volume.
Agar
;
Amorphophallus
;
Biopsy*
;
Fungi
;
Ink
;
Prostate*
;
Silicon
;
Silicones
;
Tongue*
;
Ultrasonography
6.Effects of different surface finishing protocols for zirconia on surface roughness and bacterial biofilm formation
Du Hyeong LEE ; Hang Nga MAI ; Phyu Pwint THANT ; Su Hyung HONG ; Jaewon KIM ; Seung Mi JEONG ; Keun Woo LEE
The Journal of Advanced Prosthodontics 2019;11(1):41-47
PURPOSE: Surface finishing of a zirconia restoration is essential after clinical adjustment. Herein, we investigated the effects of a surface finishing protocol for monolithic zirconia on final roughness and bacterial adherence. MATERIALS AND METHODS: Forty-eight disk-shaped monolithic zirconia specimens were fabricated and divided into four groups (n = 12) based on initial surface treatment, finishing, and polishing protocols: diamond bur+polishing bur (DP group), diamond bur+stone grinding bur+polishing bur (DSP group), no diamond bur+polishing bur (NP group), and no diamond bur+stone grinding bur+polishing bur (NSP group). Initial and final surface roughness was measured with a profilometer, and shown using scanning electron microscope. Bacterial adhesion was evaluated by quantifying Streptococcus mutans in the biofilm. Kruskal-Wallis and Mann-Whitney U tests were used to compare results among groups, and two-way analysis of variance was used to evaluate the effects of grinding burs on final roughness (α=.05). RESULTS: The DP group had the highest final Ra value, followed by the DSP, NP, and NSP groups. Use of the stone grinding bur as a coarse-finishing step significantly decreased final Ra values when a diamond bur was used (P < .001). Omission of the stone grinding bur increased biofilm formation on specimen surfaces. Combining a stone grinding bur with silicone polishing burs produced the smallest final biofilm values, regardless of the use of a diamond bur in initial surface treatment. CONCLUSION: Coarse finishing of monolithic zirconia with a stone grinding bur significantly decreased final Ra values and bacterial biofilm formation when surfaces had been roughened by a diamond bur.
Bacterial Adhesion
;
Biofilms
;
Dental Instruments
;
Dental Polishing
;
Diamond
;
Silicon
;
Silicones
;
Streptococcus mutans
7.Physical characteristics of ceramic/glass-polymer based CAD/CAM materials: Effect of finishing and polishing techniques
Mugem Asli EKICI ; Ferhan EGILMEZ ; Isil CEKIC-NAGAS ; Gulfem ERGUN
The Journal of Advanced Prosthodontics 2019;11(2):128-137
PURPOSE: The aim of this study was to compare the effect of different finishing and polishing techniques on water absorption, water solubility, and microhardness of ceramic or glass-polymer based computer-aided design and computer-aided manufacturing (CAD/CAM) materials following thermocycling. MATERIALS AND METHODS: 150 disc-shaped specimens were prepared from three different hybrid materials and divided into five subgroups according to the applied surface polishing techniques. All specimens were subjected up to #4000 grit SiC paper grinding. No additional polishing has been done to the control group (Group I). Other polishing procedures were as follows: Group II: two-stage diamond impregnated polishing discs; Group III: yellow colored rubber based silicone discs; Group IV: diamond polishing paste; and Group V: Aluminum oxide polishing discs. Subsequently, 5000-cycles of thermocycling were applied. The analyses were conducted after 24 hours, 7 days, and 30 days of water immersion. Water absorption and water solubility results were analyzed by two-way ANOVA and Tukey post-hoc tests. Besides, microhardness data were compared by Kruskal-Wallis and Mann-Whitney U tests (P<.05). RESULTS: Surface polishing procedures had significant effects on water absorption and solubility and surface microhardness of resin ceramics (P<.05). Group IV exhibited the lowest water absorption and the highest microhardness values (P<.05). Immersion periods had no effect on the microhardness of hybrid ceramic materials (P>.05). CONCLUSION: Surface finishing and polishing procedures might negatively affect physical properties of hybrid ceramic materials. Nevertheless, immersion periods do not affect the microhardness of the materials. Final polishing by using diamond polishing paste can be recommended for all CAD/CAM materials.
Absorption
;
Aluminum Oxide
;
Ceramics
;
Computer-Aided Design
;
Dental Polishing
;
Diamond
;
Immersion
;
Rubber
;
Silicon
;
Silicones
;
Solubility
;
Water
8.Effects of primers on the microtensile bond strength of resin cements to cobalt-chromium alloy
Hong Taek JUNG ; Shiela A CAMPANA ; Jin Hong PARK ; Joo Hee SHIN ; Jeong Yol LEE
The Journal of Korean Academy of Prosthodontics 2019;57(2):95-101
PURPOSE: The aim of this study is to evaluate the effects of various primers on the microtensile bond strength (µTBS) of resin cements to cobalt-chromium (Co-Cr) dental casting alloy. MATERIALS AND METHODS: Four adhesive primers (Universal primer, Metal primer II, Alloy primer, and Metal/Zirconia primer) and two resin cements (Panavia F2.0, G-CEM LinkAce) were tested. One hundred fifty Co-Cr beams were prepared from Co-Cr ingots via casting (6 mm length × 1 mm width × 1 mm thick). The metal beams were randomly divided into ten groups according to the adhesive primers and resin cements used; the no-primer groups served as the control (n = 15). After sandblasting with aluminum oxide (125 µm grain), the metal and resin cements were bonded together using a silicone mold. Prior to testing, all metal-resin beams were examined under stereomicroscope, and subjected to the µTBS test. The mean value of each group was analyzed via one-way ANOVA with Tukey's test as post hoc (α = .05) using SPSS software. RESULTS: The mean µTBS of all groups was ranged from 20 to 28 MPa. There is no statistically significant difference between groups (P > .05). Mixed failure, which is the combination of adhesive and cohesive failures, is the most prevalent failure mode in both the Panavia F2.0 and G-Cem LinkAce groups. CONCLUSION: The µTBS of all tested groups are relatively high; however, the primers used in this study result in no favorable effect in the µTBS of Panavia F2.0 and G-Cem LinkAce resin cement to Co-Cr alloy.
Adhesives
;
Alloys
;
Aluminum Oxide
;
Fungi
;
Resin Cements
;
Silicon
;
Silicones
9.An Unusual Case of Double Lacrimal Puncta
Won Seok SONG ; Hyun Sup CHOI ; Youn Joo CHOI
Journal of the Korean Ophthalmological Society 2019;60(2):187-189
PURPOSE: Congenital double puncta are usually unilateral, and the accessory punctum exists on the medial side in a slit configuration that is distinct from the shape of the normal punctum. We report a case of an unusual case of double lacrimal puncta which the lateral, rather than the medial, punctum was judged to be the accessory punctum. CASE SUMMARY: A 39-year-old male patient with no underlying disease and no ophthalmologic history visited our clinic with right eye epiphora of 2 weeks duration. On slit lamp examination, double puncta were observed in the right lower eyelid and the remaining puncta were normal. On lacrimal syringing test and dacryocystography were performed and revealed incomplete obstruction with partial narrowing of the nasolacrimal duct. Silicone tube intubation was performed through the right lower medial punctum and symptoms improved postoperatively. CONCLUSIONS: The present case is an unusual case of double lacrimal puncta which has not been reported in Korea. Unlike the previous literature, the lateral, rather than the medial, punctum was judged to be the accessory punctum. Because accessory punctm can be present on the lateral side, it is necessary to distinguish between the accessory punctm and the main punctum through the accurate dacryocystography and lacrimal syringing test for the treatment of the patient.
Adult
;
Eyelids
;
Humans
;
Intubation
;
Korea
;
Lacrimal Apparatus
;
Lacrimal Apparatus Diseases
;
Male
;
Nasolacrimal Duct
;
Silicon
;
Silicones
;
Slit Lamp
10.Reconstruction of temporal hollowing using two alloplastic materials simultaneously with titanium mesh and a silicone implant
Han Byeol JIN ; Jee Hyeok CHUNG ; Kyung Sik KIM ; Seung Hong KIM ; Joon CHOE ; Jeong Yeol YANG
Archives of Aesthetic Plastic Surgery 2019;25(1):37-41
Temporal hollowing is a contour deformity that results in a concavity or hollowing of the temporal region, causing significant cosmetic problems that affect patients both physically and psychologically. For these patients, cranioplasty is needed for protective coverage of the brain and to restore a pleasing aesthetic contour to the cranium. We report a case in which titanium mesh was used as a customized craniofacial implant for a bony defect and a silicone implant was used for soft tissue augmentation of muscle and to address temporal fat pad atrophy. The procedure resulted in high patient satisfaction from an aesthetic standpoint and, importantly, restored a functional barrier resistant to trauma.
Adipose Tissue
;
Atrophy
;
Brain
;
Congenital Abnormalities
;
Humans
;
Patient Satisfaction
;
Silicon
;
Silicones
;
Skull
;
Temporal Bone
;
Temporal Lobe
;
Titanium

Result Analysis
Print
Save
E-mail