1.Development and validation of the “Questionnaires on the Knowledge, Attitudes, and Practices of College Students in Response to Public Health Emergencies”
Hong JIANG ; Shuli MA ; Yufeng ZHANG ; Yue ZHAO ; Xinling YANG
China Occupational Medicine 2025;52(1):33-39
Objective To develop the "Questionnaires on the Knowledge, Attitudes, and Practices of College Students in Response to Public Health Emergencies" and validate its reliability and validity. Methods The initial questionnaire was developed according to literature review, expert consultations, and one-on-one interviews with students and educators. A total of 43 college students were selected as the pre-test subjects using the convenience sampling method. The final version of the questionnaire was developed using item analysis and expert consultations. A total of 682 college students were selected as the validation subjects using the cluster sampling method. The exploratory factor analysis and confirmatory factor analysis were used to assess the reliability and validity of the questionnaire. Results The final version of the questionnaire consisted of three dimensions: knowledge, practice, and attitude, with 5, 10, 7 items, respectively. The KMO test value for the questionnaire was 0.804, with Bartlett′s test of sphericity showing a chi-square value of 2 000.557 (P<0.01). The content validity index for each item ranged from 0.894 to 1.000, with the overall content validity index for the questionnaire being 0.966 and 0.973. The exploratory factor analysis identified three common factors, with a cumulative variance contribution rate of 54.1%. The result of confirmatory factor analysis showed good model fit, with model fit index, comparative fit index, normed fit index, incremental fit index, Tucker-Lewis Index, root mean square error of approximation of 2.960, 0.930, 0.940, 0.930, 0.950 and 0.070, respectively. The Cronbach's α coefficient for the questionnaire was 0.772, split-half reliability was 0.604, and test-retest reliability was 0.905. Conclusion The "Questionnaires on the Knowledge, Attitudes, and Practices of College Students in Response to Public Health Emergencies" demonstrates good reliability, and it is suitable for widespread application.
2.Mechanism of quercetin alleviating postherpetic neuralgia in rats by inhibiting MIP-1α/CCR1/CCR5 signaling pathway
Jiayu TIAN ; Dan FENG ; Han HU ; Shuli ZHANG ; Shengxiong TONG ; Shaojun LI
Tianjin Medical Journal 2024;52(3):256-260
Objective To investigate the impact of quercetin(Que)on postherpetic neuralgia(PHN)and chemokine ligand 3(CCL3,namely MIP-1α)/C-C chemokine receptor 1(CCR1)/C-C chemokine receptor 5(CCR5)signaling pathway in rats.Methods Sixty rats were divided into the control group(Con),the PHN group(model group),the L-Que(30 mg/kg)group,the M-Que(60 mg/kg)group,the H-Que(120 mg/kg)group and the H-Que+pathway activator MIP-1α(120 mg/kg Que+0.4 mg/kg recombinant MIP-1α)group.The mechanical paw withdrawal threshold(PWT)and thermal pain threshold(TWL)of rats were detected in each group.The kit was used to detect adenosine,Adenine ribonucleotide(AMP),adenosine diphosphate(ADP)and tumor necrosis factor in spinal dorsal horn samples-α(TNF-α),and interleukin-1 β(IL-1 β)levels in spinal dorsal horn samples.HE staining was applied to observe the pathological sections of spinal dorsal horn.Immunofluorescence staining was used to detect the activation of microglia in spinal dorsal horn.Western blot assay was applied to detect MIP-1α/CCR1/CCR5 signaling pathway protein expression.Results In the PHN group,the dorsal horn of the spinal cord was ruptured,the arrangement of nerve bundles was disordered,and inflammatory cell infiltration,edema,and slight atrophy of neurons appeared.Compared with the Con group,the PWT value,adenosine,AMP and ADP levels were obviously decreased in the PHN group(P<0.05),and TWL value,TNF-α,IL-1β levels,the number of Iba1-positive microglia,MIP-1α,CCR1 and CCR5 protein levels were obviously increased(P<0.05).After treatment with Que,the disordered arrangement of nerve bundles was improved,the infiltration of inflammatory cells was reduced,and the phenomenon of neuronal atrophy disappeared.Compared with the PHN group,the PWT value,adenosine,AMP and ADP levels were obviously increased in the L-Que group,the M-Que group and the H-Que group(P<0.05).TWL value,TNF-αand IL-1β levels,the number of Iba1-positive microglia,and MIP-1α,CCR1 and CCR5 protein levels were obviously decreased(P<0.05).The effect of Que was dose dependent.Compared with the H-Que group,PWT value,adenosine,AMP and ADP levels were obviously decreased in the H-Que+MIP-1α group(P<0.05),and TWL value,TNF-α,IL-1β levels,the number of Iba1 positive microglia,MIP-1α,CCR1 and CCR5 protein levels were obviously increased(P<0.05).Conclusion Que may reduce the inflammatory response in rats by inhibiting the MIP-1α/CCR1/CCR5 signaling pathway,thereby reducing PHN.
3.Construction of blood quality monitoring indicator system in blood banks of Shandong
Qun LIU ; Xuemei LI ; Yuqing WU ; Zhiquan RONG ; Zhongsi YANG ; Zhe SONG ; Shuhong ZHAO ; Lin ZHU ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xiaojuan FAN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):249-257
【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level
4.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
5.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
6.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
7.Health Economic Evaluation of Hepatocellular Carcinoma Screening and Optimal Delicacy Management Strategies in China
Qing XIE ; Fangzhou WANG ; Liyue ZHANG ; Shuli QU ; Jingya WU ; Yihan LIAO ; Chunlin JIN
Chinese Health Economics 2024;43(2):16-20
Objective:Based on the cost-effectiveness,it aimed to assess the health benefits amd economic value of screening,di-agnosis,treatment,and optimal delicacy management of liver disease in hepatocellular carcinoma(HCC)patients.Methods:A Deci-sion tree-Markov model was developed to compare the cost-effectiveness of HCC screening and long-term surveillance versus no screening in population at risk from the health care system perspective.Results:It is found that HCC screening was a cost-effective approach compared to no screening(Incremental Cost-Effectiveness Ratio[ICER]:17 790 yuan/QALY).Scenario analyses suggested that initiating HCC screening at the age of 40,as recommended by clinical guidelines,and implementing long-term surveillance based on risk stratification were more cost-effective.Conclusions:For the implementation of HCC screening programs,attention should be paid to improving participation and compliance among the population at risk,incorporating advanced screening methods,improving management efficiency with digital tools,and introducing innovative payment methods to reduce economic burden.
8.Expert consensus on difficulty assessment of endodontic therapy
Huang DINGMING ; Wang XIAOYAN ; Liang JINGPING ; Ling JUNQI ; Bian ZHUAN ; Yu QING ; Hou BENXIANG ; Chen XINMEI ; Li JIYAO ; Ye LING ; Cheng LEI ; Xu XIN ; Hu TAO ; Wu HONGKUN ; Guo BIN ; Su QIN ; Chen ZHI ; Qiu LIHONG ; Chen WENXIA ; Wei XI ; Huang ZHENGWEI ; Yu JINHUA ; Lin ZHENGMEI ; Zhang QI ; Yang DEQIN ; Zhao JIN ; Pan SHUANG ; Yang JIAN ; Wu JIAYUAN ; Pan YIHUAI ; Xie XIAOLI ; Deng SHULI ; Huang XIAOJING ; Zhang LAN ; Yue LIN ; Zhou XUEDONG
International Journal of Oral Science 2024;16(1):15-25
Endodontic diseases are a kind of chronic infectious oral disease.Common endodontic treatment concepts are based on the removal of inflamed or necrotic pulp tissue and the replacement by gutta-percha.However,it is very essential for endodontic treatment to debride the root canal system and prevent the root canal system from bacterial reinfection after root canal therapy(RCT).Recent research,encompassing bacterial etiology and advanced imaging techniques,contributes to our understanding of the root canal system's anatomy intricacies and the technique sensitivity of RCT.Success in RCT hinges on factors like patients,infection severity,root canal anatomy,and treatment techniques.Therefore,improving disease management is a key issue to combat endodontic diseases and cure periapical lesions.The clinical difficulty assessment system of RCT is established based on patient conditions,tooth conditions,root canal configuration,and root canal needing retreatment,and emphasizes pre-treatment risk assessment for optimal outcomes.The findings suggest that the presence of risk factors may correlate with the challenge of achieving the high standard required for RCT.These insights contribute not only to improve education but also aid practitioners in treatment planning and referral decision-making within the field of endodontics.
9.Expert consensus on irrigation and intracanal medication in root canal therapy
Zou XIAOYING ; Zheng XIN ; Liang YUHONG ; Zhang CHENGFEI ; Fan BING ; Liang JINGPING ; Ling JUNQI ; Bian ZHUAN ; Yu QING ; Hou BENXIANG ; Chen ZHI ; Wei XI ; Qiu LIHONG ; Chen WENXIA ; He WENXI ; Xu XIN ; Meng LIUYAN ; Zhang CHEN ; Chen LIMING ; Deng SHULI ; Lei YAYAN ; Xie XIAOLI ; Wang XIAOYAN ; Yu JINHUA ; Zhao JIN ; Shen SONG ; Zhou XUEDONG ; Yue LIN
International Journal of Oral Science 2024;16(1):26-35
Chemical cleaning and disinfection are crucial steps for eliminating infection in root canal treatment.However,irrigant selection or irrigation procedures are far from clear.The vapor lock effect in the apical region has yet to be solved,impeding irrigation efficacy and resulting in residual infections and compromised treatment outcomes.Additionally,ambiguous clinical indications for root canal medication and non-standardized dressing protocols must be clarified.Inappropriate intracanal medication may present side effects and jeopardize the therapeutic outcomes.Indeed,clinicians have been aware of these concerns for years.Based on the current evidence of studies,this article reviews the properties of various irrigants and intracanal medicaments and elucidates their effectiveness and interactions.The evolution of different kinetic irrigation methods,their effects,limitations,the paradigm shift,current indications,and effective operational procedures regarding intracanal medication are also discussed.This expert consensus aims to establish the clinical operation guidelines for root canal irrigation and a position statement on intracanal medication,thus facilitating a better understanding of infection control,standardizing clinical practice,and ultimately improving the success of endodontic therapy.
10.Discussion on the TCM pathogenesis of acute respiratory distress syndrome of sepsis syndrome from "blood stasis with toxin blocking collaterals" and "deficient healthy qi"
Qing ZHANG ; Chengxiang WANG ; Shuli CHENG ; Nan KOU ; Jingqin WU ; Hongri XU ; Qingquan LIU
International Journal of Traditional Chinese Medicine 2024;46(6):681-685
Acute respiratory distress syndrome is one of the common complications of sepsis syndrome, belonging to the "Chuan syndrome", "Baochuan", and "Chuantuo" in the TCM field, and the disease is mainly located in the lung. The main etiology and pathogenesis of sepsis syndrome is deficient healthy qi and blood stasis with toxin blocking collaterals. Blood stasis and toxin invade the lung, causing heat and toxin to burn the body fluid in the blood. Blood viscosity and poor circulation lead to the accumulation of blood stasis and toxin in the lung. Acute deficiency syndrome, heat toxin damaging qi, heat toxin burning body fluid deficiency with little ability to dissipate qi, resulting in deficiency of healthy qi, inability to regulate breathing, inability to consolidate body fluid, inability to promote blood circulation, causing phlegm, dampness, and blood stasis blocking the lung. This disease is characterized by blood stasis with toxin blocking collaterals, deficient lung qi, and obstruction of lung qi caused by phlegm, water, dampness, and blood stasis. Therefore, blood stasis with toxin blocking collaterals, as well as deficient healthy qi are TCM pathogenesis of ARDS with sepsis syndrome.

Result Analysis
Print
Save
E-mail