1.Development and validation of the “Questionnaires on the Knowledge, Attitudes, and Practices of College Students in Response to Public Health Emergencies”
Hong JIANG ; Shuli MA ; Yufeng ZHANG ; Yue ZHAO ; Xinling YANG
China Occupational Medicine 2025;52(1):33-39
Objective To develop the "Questionnaires on the Knowledge, Attitudes, and Practices of College Students in Response to Public Health Emergencies" and validate its reliability and validity. Methods The initial questionnaire was developed according to literature review, expert consultations, and one-on-one interviews with students and educators. A total of 43 college students were selected as the pre-test subjects using the convenience sampling method. The final version of the questionnaire was developed using item analysis and expert consultations. A total of 682 college students were selected as the validation subjects using the cluster sampling method. The exploratory factor analysis and confirmatory factor analysis were used to assess the reliability and validity of the questionnaire. Results The final version of the questionnaire consisted of three dimensions: knowledge, practice, and attitude, with 5, 10, 7 items, respectively. The KMO test value for the questionnaire was 0.804, with Bartlett′s test of sphericity showing a chi-square value of 2 000.557 (P<0.01). The content validity index for each item ranged from 0.894 to 1.000, with the overall content validity index for the questionnaire being 0.966 and 0.973. The exploratory factor analysis identified three common factors, with a cumulative variance contribution rate of 54.1%. The result of confirmatory factor analysis showed good model fit, with model fit index, comparative fit index, normed fit index, incremental fit index, Tucker-Lewis Index, root mean square error of approximation of 2.960, 0.930, 0.940, 0.930, 0.950 and 0.070, respectively. The Cronbach's α coefficient for the questionnaire was 0.772, split-half reliability was 0.604, and test-retest reliability was 0.905. Conclusion The "Questionnaires on the Knowledge, Attitudes, and Practices of College Students in Response to Public Health Emergencies" demonstrates good reliability, and it is suitable for widespread application.
2.The early prediction of umbilical cord blood S100β protein and lactate combined with amplitude integrated electroencephalogram in small for gestational age preterm infants with brain injury
Junlong CHEN ; Xiaoli WANG ; Xiaoling YANG ; Xuewen SU ; Fuhua JIA ; Shuli WU
International Journal of Pediatrics 2024;51(1):64-68
Objective:To explore the early predictive value of umbilical cord blood S100β protein and lactate combined with amplitude integrated electroencephalogram(aEEG)in small for gestational age(SGA)preterm infants with brain injury.Methods:One hundred and six cases of SGA preterm infants were enrolled in this study in Neonatology Department of Inner Mongolia People's Hospital from January 2019 to December 2021. Umbilical cord blood serum S100β protein and lactate at birth of All SGA preterm infants were tested,and aEEG was monitored at 6h and 72 h after birth,corrected gestational age of 32 weeks and 37 weeks. According to the diagnostic criteria of brain injury in preterm infants,SGA preterm infants were divided into brain injury group(45 cases)and non-brain injury group(61 cases),and compared the differences of S100β protein,lactate and the designated time aEEG between the two groups.SGA preterm infants with brain injury were further divided into symmetrical group(28 cases)and non-symmetrical group(15 cases). The differences of umbilical cord blood S100β protein and lactate level between the two groups were compared,and the diagnostic value in different types of SGA preterm infants with brain injury was also compared.Results:SGA preterm infants in the brain injury group had significantly higher levels of umbilical cord blood S100β protein[(0.826±0.218)μg/L vs(0.397±0.196)μg/L, t=8.316, P<0.05]and lactate[(8.5±1.3)mmol/L vs(3.8±0.9)mmol/L, t=3.281, P<0.05]than those in non-brain injury group.Symmetric SGA group had higher level of S100β protein than the asymmetric SGA group[(0.924±0.205)μg/L vs(0.438±0.196)μg/L, t=5.734, P<0.05].But there was no statistically significant difference in lactate levels[(5.6±1.4)mmol/L vs(3.9±1.2)mmol/L, t=0.932, P>0.05]between symmetric SGA group and asymmetric SGA group. The abnormal rates of aEEG in brain injury group and non-brain injury group were respectively 100%(45/45)vs 22.95%(14/61)at 6 h after birth,95.56%(43/45)vs 16.39%(10/61)at 72 h after birth,62.22%(28/45)vs 6.56%(4/61)at 32 weeks of corrected gestational age,22.22%(10/45)vs 3.28%(2/61)at 37 weeks of corrected gestational age. The abnormal rate of brain injury group was higher than the non-brain injury group in the same nodal time,and the differences were statistically significant( χ 2 value respectively 62.292,64.913,38.074,9.257,all P<0.05). Conclusion:There were significant value in umbilical cord blood S100β protein,lactate level and aEEG monitoring in the early diagnosis in preterm infants SGA with brain injury. The combination of the three might be more helpful for the early diagnosis and timely treatment of brain injury in SGA preterm infants.
3.Construction of blood quality monitoring indicator system in blood banks of Shandong
Qun LIU ; Xuemei LI ; Yuqing WU ; Zhiquan RONG ; Zhongsi YANG ; Zhe SONG ; Shuhong ZHAO ; Lin ZHU ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xiaojuan FAN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):249-257
【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level
4.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
5.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
6.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
7.Expert consensus on difficulty assessment of endodontic therapy
Huang DINGMING ; Wang XIAOYAN ; Liang JINGPING ; Ling JUNQI ; Bian ZHUAN ; Yu QING ; Hou BENXIANG ; Chen XINMEI ; Li JIYAO ; Ye LING ; Cheng LEI ; Xu XIN ; Hu TAO ; Wu HONGKUN ; Guo BIN ; Su QIN ; Chen ZHI ; Qiu LIHONG ; Chen WENXIA ; Wei XI ; Huang ZHENGWEI ; Yu JINHUA ; Lin ZHENGMEI ; Zhang QI ; Yang DEQIN ; Zhao JIN ; Pan SHUANG ; Yang JIAN ; Wu JIAYUAN ; Pan YIHUAI ; Xie XIAOLI ; Deng SHULI ; Huang XIAOJING ; Zhang LAN ; Yue LIN ; Zhou XUEDONG
International Journal of Oral Science 2024;16(1):15-25
Endodontic diseases are a kind of chronic infectious oral disease.Common endodontic treatment concepts are based on the removal of inflamed or necrotic pulp tissue and the replacement by gutta-percha.However,it is very essential for endodontic treatment to debride the root canal system and prevent the root canal system from bacterial reinfection after root canal therapy(RCT).Recent research,encompassing bacterial etiology and advanced imaging techniques,contributes to our understanding of the root canal system's anatomy intricacies and the technique sensitivity of RCT.Success in RCT hinges on factors like patients,infection severity,root canal anatomy,and treatment techniques.Therefore,improving disease management is a key issue to combat endodontic diseases and cure periapical lesions.The clinical difficulty assessment system of RCT is established based on patient conditions,tooth conditions,root canal configuration,and root canal needing retreatment,and emphasizes pre-treatment risk assessment for optimal outcomes.The findings suggest that the presence of risk factors may correlate with the challenge of achieving the high standard required for RCT.These insights contribute not only to improve education but also aid practitioners in treatment planning and referral decision-making within the field of endodontics.
8.Evaluation of the effect of contrast medium injection in CT enhanced examination of malignant tumor patients with standardized nursing procedure of totally implantable venous power port
Yanli PENG ; Yifan WANG ; Shuli FENG ; Xingping TANG ; Yuanfang LIU ; Yanping LUO ; Xiang ZHANG ; Ming GAO ; Zehong YANG ; Hong DENG
Chinese Journal of Practical Nursing 2024;40(22):1705-1709
Objective:To explore the standardization of totally implantable venous power port of nursing process in CT enhancement and application effect of contrast medium injection, so as to provide a safer and more efficient way for contrast medium injection in CT enhanced examination for patients with malignant tumors.Methods:A non-randomized prospective study was conducted, 358 patients with malignant tumors were selected in Sun Yat-sen Memorial Hospital, Sun Yat-sen University who underwent CT enhanced examination from August 1, 2022 to July 31, 2023, 179 patients who had been implanted totally implantable venous power port were selected as the experimental group, and the standardized nursing procedure was given. The other 179 patients were the control group, using radiology routine high-pressure intravenous indwelling needle as the contrast medium access, with routine peripheral venous nursing process. The incidence of contrast medium extravasation during CT enhanced examination was observed and compared between the two groups.Results:All the patients were included. There were 85 males and 94 females, aged (55.50±11.72) years old in the control group. There were 83 males and 96 females, aged (54.50±12.24) years old in the experimental group. The incidence of contrast medium extravasation was 0 in the experimental group and 3.35%(6/179) in the control group. The difference between the two groups was statistically significant (Fisher exact probability, P<0.05). Conclusions:The application of standardized nursing procedure of totally implantable venous power port to the injection of contrast medium in CT enhanced examination of malignant tumor patients, can significantly reduce the incidence of contrast medium extravasation.
9.Clinical and genetic analysis of one patient with familial glucocorticoid deficiency type 4 caused by NNT gene variation
Junlin WANG ; Mingying HAN ; Changjuan ZHAO ; Shuli WANG ; Xiuying QIAO ; Yang GUO ; Meihong SUN
Chinese Journal of Endocrinology and Metabolism 2024;40(7):580-585
Familial glucocorticoid deficiency type 4(FGD4) is a rare autosomal recessive disorder caused by mutations in the nicotinamide nucleotide transhydrogenase(NNT) gene. The article presented clinical data, laboratory results, and genetic mutation findings of a child with FGD4. Additionally, a retrospective analysis of the clinical data of FGD4 patients reported domestically and internationally was conducted, summarizing the types of gene mutations and clinical characteristics. This case identifies novel mutation sites in the NNT gene, providing a basis for the early diagnosis and treatment of FGD4 patients.
10.Experts consensus on the procedure of dental operative microscope in endodontics and operative dentistry.
Bin LIU ; Xuedong ZHOU ; Lin YUE ; Benxiang HOU ; Qing YU ; Bing FAN ; Xi WEI ; Lihong QIU ; Zhengwei HUANG ; Wenwei XIA ; Zhe SUN ; Hanguo WANG ; Liuyan MENG ; Bin PENG ; Chen ZHANG ; Shuli DENG ; Zhaojie LU ; Deqin YANG ; Tiezhou HOU ; Qianzhou JIANG ; Xiaoli XIE ; Xuejun LIU ; Jiyao LI ; Zuhua WANG ; Haipeng LYU ; Ming XUE ; Jiuyu GE ; Yi DU ; Jin ZHAO ; Jingping LIANG
International Journal of Oral Science 2023;15(1):43-43
The dental operative microscope has been widely employed in the field of dentistry, particularly in endodontics and operative dentistry, resulting in significant advancements in the effectiveness of root canal therapy, endodontic surgery, and dental restoration. However, the improper use of this microscope continues to be common in clinical settings, primarily due to operators' insufficient understanding and proficiency in both the features and established operating procedures of this equipment. In October 2019, Professor Jingping Liang, Vice Chairman of the Society of Cariology and Endodontology, Chinese Stomatological Association, organized a consensus meeting with Chinese experts in endodontics and operative dentistry. The objective of this meeting was to establish a standard operation procedure for the dental operative microscope. Subsequently, a consensus was reached and officially issued. Over the span of about four years, the content of this consensus has been further developed and improved through practical experience.
Humans
;
Dentistry, Operative
;
Consensus
;
Endodontics
;
Root Canal Therapy
;
Dental Care

Result Analysis
Print
Save
E-mail