1.The value of early VA-ECMO support in the perioperative period of emergency percutaneous coronary intervention
Haijia YU ; Jingchao LI ; Huihui SONG ; Luqian CUI ; Shujuan DONG ; Yingjie CHU ; Lijie QIN
Chinese Journal of Emergency Medicine 2024;33(7):946-954
Objective:To investigate the effect of different timing of arterial -venous extracorporeal membrane oxygenation (VA-ECMO) on the prognosis of patients with acute myocardial infarction complicated with cardiogenic shock (AMICS).Methods:This study was a prospective cohort study. AMICS patients received VA-ECMO support primary percutaneous coronary intervention in Henan Provincial People's Hospital from May 2017 to July 2023 were divided into early VA-ECMO group and late VA-ECMO group. 64 AMICS patients who met the indications for VA-ECMO implantation, but did not revive VA-ECMO were included as control group. Demographic characteristics, coronary interventional (PCI) information and complications after VA-ECMO implantation were collected. The primary end points was 1-year survival, minor end point were in-hospital and perioperative death. Multivariate Logistic and Cox regression models were used to evaluate the effect of timing of VA-ECMO on prognosis of AMICS patients. Kaplan-Meier survival curve was used to analyze the 1-year survival outcome of the 3 groups.Results:A total of 143 AMICS patients were included, and materials of 136 patients entered in the final analysis, including 42 in the early VA-ECMO group, 34 in the late VA-ECMO group, and 60 in the non-VA-ECMO group. Compared with the late VA-ECMO group, the early VA-ECMO group had a higher ratio of PPCI after VA-ECMO, a longer D-to-B time, a shorter VA-ECMO support time, a higher success rate of VA-ECMO withdrawal, and a lower complication rate (all P<0.05). Compared with the early VA-ECMO group, the perioperative, in-hospital and 1-year mortality were significantly higher in Non-ECMO support (all P<0.05). There was no difference in perioperative and in-hospital mortality between the early VA-ECMO group and the late VA-ECMO group, but the 1-year mortality in the late VA-ECMO group was significantly higher ( P<0.05). Perioperative, in-hospital and 1-year mortality rates were lower in the late VA-ECMO group than in the no-VA-ECMO group, but the differences were not statistically significant. Multivariate Logistic and Cox regression analysis showed that after adjusting interference factors, early VA-ECMO was still a protective factor for in-hospital ( OR=0.244, P=0.015) and one year ( HR=0.308, P=0.001)mortality. Kaplan-Merier survival curve showed that compared with the late VA-ECMO group and the group without VA-ECMO, the early VA-ECMO group had the highest 1-year survival rate. Conclusion:Patients with AMICS may benefit more from early VA-ECMO than from late VA-ECMO support for PPCI.
2.Chinese expert consensus on blood support mode and blood transfusion strategies for emergency treatment of severe trauma patients (version 2024)
Yao LU ; Yang LI ; Leiying ZHANG ; Hao TANG ; Huidan JING ; Yaoli WANG ; Xiangzhi JIA ; Li BA ; Maohong BIAN ; Dan CAI ; Hui CAI ; Xiaohong CAI ; Zhanshan ZHA ; Bingyu CHEN ; Daqing CHEN ; Feng CHEN ; Guoan CHEN ; Haiming CHEN ; Jing CHEN ; Min CHEN ; Qing CHEN ; Shu CHEN ; Xi CHEN ; Jinfeng CHENG ; Xiaoling CHU ; Hongwang CUI ; Xin CUI ; Zhen DA ; Ying DAI ; Surong DENG ; Weiqun DONG ; Weimin FAN ; Ke FENG ; Danhui FU ; Yongshui FU ; Qi FU ; Xuemei FU ; Jia GAN ; Xinyu GAN ; Wei GAO ; Huaizheng GONG ; Rong GUI ; Geng GUO ; Ning HAN ; Yiwen HAO ; Wubing HE ; Qiang HONG ; Ruiqin HOU ; Wei HOU ; Jie HU ; Peiyang HU ; Xi HU ; Xiaoyu HU ; Guangbin HUANG ; Jie HUANG ; Xiangyan HUANG ; Yuanshuai HUANG ; Shouyong HUN ; Xuebing JIANG ; Ping JIN ; Dong LAI ; Aiping LE ; Hongmei LI ; Bijuan LI ; Cuiying LI ; Daihong LI ; Haihong LI ; He LI ; Hui LI ; Jianping LI ; Ning LI ; Xiying LI ; Xiangmin LI ; Xiaofei LI ; Xiaojuan LI ; Zhiqiang LI ; Zhongjun LI ; Zunyan LI ; Huaqin LIANG ; Xiaohua LIANG ; Dongfa LIAO ; Qun LIAO ; Yan LIAO ; Jiajin LIN ; Chunxia LIU ; Fenghua LIU ; Peixian LIU ; Tiemei LIU ; Xiaoxin LIU ; Zhiwei LIU ; Zhongdi LIU ; Hua LU ; Jianfeng LUAN ; Jianjun LUO ; Qun LUO ; Dingfeng LYU ; Qi LYU ; Xianping LYU ; Aijun MA ; Liqiang MA ; Shuxuan MA ; Xainjun MA ; Xiaogang MA ; Xiaoli MA ; Guoqing MAO ; Shijie MU ; Shaolin NIE ; Shujuan OUYANG ; Xilin OUYANG ; Chunqiu PAN ; Jian PAN ; Xiaohua PAN ; Lei PENG ; Tao PENG ; Baohua QIAN ; Shu QIAO ; Li QIN ; Ying REN ; Zhaoqi REN ; Ruiming RONG ; Changshan SU ; Mingwei SUN ; Wenwu SUN ; Zhenwei SUN ; Haiping TANG ; Xiaofeng TANG ; Changjiu TANG ; Cuihua TAO ; Zhibin TIAN ; Juan WANG ; Baoyan WANG ; Chunyan WANG ; Gefei WANG ; Haiyan WANG ; Hongjie WANG ; Peng WANG ; Pengli WANG ; Qiushi WANG ; Xiaoning WANG ; Xinhua WANG ; Xuefeng WANG ; Yong WANG ; Yongjun WANG ; Yuanjie WANG ; Zhihua WANG ; Shaojun WEI ; Yaming WEI ; Jianbo WEN ; Jun WEN ; Jiang WU ; Jufeng WU ; Aijun XIA ; Fei XIA ; Rong XIA ; Jue XIE ; Yanchao XING ; Yan XIONG ; Feng XU ; Yongzhu XU ; Yongan XU ; Yonghe YAN ; Beizhan YAN ; Jiang YANG ; Jiangcun YANG ; Jun YANG ; Xinwen YANG ; Yongyi YANG ; Chunyan YAO ; Mingliang YE ; Changlin YIN ; Ming YIN ; Wen YIN ; Lianling YU ; Shuhong YU ; Zebo YU ; Yigang YU ; Anyong YU ; Hong YUAN ; Yi YUAN ; Chan ZHANG ; Jinjun ZHANG ; Jun ZHANG ; Kai ZHANG ; Leibing ZHANG ; Quan ZHANG ; Rongjiang ZHANG ; Sanming ZHANG ; Shengji ZHANG ; Shuo ZHANG ; Wei ZHANG ; Weidong ZHANG ; Xi ZHANG ; Xingwen ZHANG ; Guixi ZHANG ; Xiaojun ZHANG ; Guoqing ZHAO ; Jianpeng ZHAO ; Shuming ZHAO ; Beibei ZHENG ; Shangen ZHENG ; Huayou ZHOU ; Jicheng ZHOU ; Lihong ZHOU ; Mou ZHOU ; Xiaoyu ZHOU ; Xuelian ZHOU ; Yuan ZHOU ; Zheng ZHOU ; Zuhuang ZHOU ; Haiyan ZHU ; Peiyuan ZHU ; Changju ZHU ; Lili ZHU ; Zhengguo WANG ; Jianxin JIANG ; Deqing WANG ; Jiongcai LAN ; Quanli WANG ; Yang YU ; Lianyang ZHANG ; Aiqing WEN
Chinese Journal of Trauma 2024;40(10):865-881
Patients with severe trauma require an extremely timely treatment and transfusion plays an irreplaceable role in the emergency treatment of such patients. An increasing number of evidence-based medicinal evidences and clinical practices suggest that patients with severe traumatic bleeding benefit from early transfusion of low-titer group O whole blood or hemostatic resuscitation with red blood cells, plasma and platelet of a balanced ratio. However, the current domestic mode of blood supply cannot fully meet the requirements of timely and effective blood transfusion for emergency treatment of patients with severe trauma in clinical practice. In order to solve the key problems in blood supply and blood transfusion strategies for emergency treatment of severe trauma, Branch of Clinical Transfusion Medicine of Chinese Medical Association, Group for Trauma Emergency Care and Multiple Injuries of Trauma Branch of Chinese Medical Association, Young Scholar Group of Disaster Medicine Branch of Chinese Medical Association organized domestic experts of blood transfusion medicine and trauma treatment to jointly formulate Chinese expert consensus on blood support mode and blood transfusion strategies for emergency treatment of severe trauma patients ( version 2024). Based on the evidence-based medical evidence and Delphi method of expert consultation and voting, 10 recommendations were put forward from two aspects of blood support mode and transfusion strategies, aiming to provide a reference for transfusion resuscitation in the emergency treatment of severe trauma and further improve the success rate of treatment of patients with severe trauma.
3.Feasibility and safety of remote programming in postoperative follow-up of cardiovascular implantable electronic devices
Yu LONG ; Lin TONG ; Shujuan QIN ; Jin LI ; Shiqiang XIONG ; Lin CAI
Chinese Journal of Cardiology 2024;52(6):684-689
Objective:To explore the feasibility and safety of remote programming technology based on 5G cloud technology support platform in postoperative follow-up of cardiovascular implantable electronic devices(CIED).Methods:This study was a multicenter cross-sectional study. CIED patients from 12 hospitals lacking full-time follow-up specialists in Sichuan Province were enrolled from June 2021 to October 2021. All patients′ devices received remote inspecting and programming by the follow-up specialist of the remote follow-up center of the Third People′s Hospital of Chengdu through 5G cloud technology support platform. The baseline data, device alarm events, device reprogramming events, adverse reactions and satisfaction questionnaire survey results were collected.Results:A total of 195 CIED implantation patients were included, with an age of (72.5±11.3) years, including 103 males (52.6%). All patients completed remote inspecting and programming successfully, with a duration of (5.8±4.0) min. Ninety-one patients′ CIED were reprogrammed, with a total of 104 parameter adjustments. No abnormal communication or adverse events occurred. The satisfaction questionnaire showed that 97.9%(191/195) of the patients trusted or relatively trusted remote follow-up and 86.7%(169/195) of the patients were willing to choose remote follow-up mode for device management.Conclusion:The remote programming based on 5G cloud technology support platform may be feasible and safe for postoperative follow-up of CIED patients.
4.Multi-enzyme isothermal rapid amplification assay for the detection of Escherichia coli O157∶H7
Shujuan WANG ; Yiling FAN ; Zhen FENG ; Bo JIANG ; Minghui SONG ; Qiongqiong LI ; Hao LIU ; Feng QIN ; Meicheng YANG
Shanghai Journal of Preventive Medicine 2022;34(6):511-518
ObjectiveA rapid enrichment and detection method for Escherichia coli O157∶H7 was developed by using multienzyme isothermal rapid amplification (MIRA) fluorescence method combined with metal organic frameworks immunomagnetic beads. MethodsUsing rfbE gene as the target, the primers, probes and reaction system were screened, and the specificity, sensitivity and practical application of this method were investigated. ResultsThe detection limit of Escherichia coli O157∶H7 was 1.18×105 CFU‧mL-1, and the detection limit of DNA concentration was 9 pg‧μL-1. The detection process was completed in 20 minutes. The test results of 47 strains (24 target strains and 23 non-target strains) were consistent with real-time PCR (RT-PCR). ConclusionA method based on metal-organic framework immunomagnetic beads enrichment combined with MIRA assay is developed in this study. The method is simple, rapid and suitable for rapid enrichment and detection of Escherichia coli O157∶H7 in food.
5.Clinical analysis of 555 outpatients with hand, foot and mouth diseases caused by different enteroviruses
Peng CUI ; Yu LI ; Chongchen ZHOU ; Yonghong ZHOU ; Chunlan SONG ; Qi QIU ; Fang WANG ; Chun GUO ; Shujuan HAN ; Lu LIANG ; Yan YUAN ; Mengyao ZENG ; Jin YUE ; Lu LONG ; Xinhua QIN ; Zhi LI ; Xiulan CHEN ; Yanping ZOU ; Yibing CHENG ; Hongjie YU
Chinese Journal of Pediatrics 2019;57(6):445-451
Objective To study the clinical characteristics of outpatients with hand,foot and mouth disease (HFMD) caused by different serotypes of enteroviruses.Methods This was a prospective study.From February 2017 to March 2018,563 outpatients with HFMD were enrolled by systematic sampling in the Department of Infectious Diseases,Henan Children's Hospital.Throat swabs were collected to determine the serotypes via PCR.Demographic,clinical,and laboratory data were collected by standard questionnaire.All cases were followed up twice at 2 and 9 weeks after the initial outpatient visit through telephone interview.A total of 563 cases were enrolled and 555 (98.6%) cases were positive for human enteroviruses,including 338 (60.9%) males.Analyses were stratified by enterovirus serotypes,Chi square test or Fisher's exact test,Rank sum test was used for comparison among different groups.Results The age of 555 cases was 24.2 (16.4,41.3) months.Among them 44.0% (224 cases) were identified as coxsackievirus (CV)-A6,while 189 cases,35 cases,14 cases and 73 cases were identified as CV-A16,enterovirus (EV)-A71,CV-A10 and other serotypes,respectively.Fever (≥37.5 ℃C) was present in 51.4%(285/555) of laboratory confirmed cases.The proportions of fever in cases of CV-A6 (68.9%(168/244)) and CV-A10 (12/14) were significantly higher than those in cases of CV-A16 (31.7%(60/189),x2=57.344,14.313,both P=0.000),other serotypes (43.8%(32/73),x2=15.101 and 8.242,P=0.000 and 0.004) and EV-A71 (37.1%(13/35),x2=13.506 and 9.441,P=0.000 and 0.002) respectively.There was no significant difference between CV-A6 and CV-A10 in presentation of fever (x2=1.785,P=0.182).There were 359 cases (64.7%) with eruptions in mouth,hands,feet and buttocks.Cases infected with EV-A71 had the highest proportions (74.3%(26/35)) of rash emerging simultaneously in mouth,hands,feet,and buttocks.The proportion in cases of CV-A 16,CV-A6,CVA 10 and other serotype were 73.5% (139/189),61.9% (151/244),7/14 and 49.3% (36/73),respectively.The proportion of rash on other parts of body,such as face,limbs or torso in cases infected with CV-A6 (16.8% (41/244)) was the higherest and the proportion in cases of CV-A16,EV-A71,CV-A10 or other serotypes were 8.5%(16/189),5.7%(2/35),1/14,6.8%(5/73),respectively.None of these cases developed serious complications.Desquamation occurred in 45.5% (179/393) cases 7.5 (5.0,9.0) days after disease onset and 13.5% (53/393) cases showed onychomadesis 31.0 (18.0,33.5) days after disease onset.The proportion of desquamation and onychomadesis associated with CV-A6 (64.2% (95/148) and 31.8% (47/148)) was significantly higher than CV-A16 (31.8% (49/154) and 1.3% (2/154),x2=33.601 and 52.482,both P=0.000) and other serotypes (38.0%(19/50) and 6.0%(3/50),x2=10.236 and 12.988,P=0.001 and 0.000).Desquamation appeared more in cases of CV-A6 than in cases of CV-A10 (2/11,x2=9.386,P=0.002),with the proportion of onychomadesis higher in CV-A6 than in EV-A71 (3.3% (1/30),x2=11.088,P=0.001).Conclusion Clinical manifestation such as fever,rash emerging parts,desquamation and onychomadesis are different among outpatient HFMD cases infected with CV-A16,CV-A6,EV-A71,CV-A10 and other enteroviruses.
7.Efficacy and safety of mycophenolate mofetil in treatment of IgA nephropathy: a systematic review
Qin WANG ; Jianjiang ZHANG ; Wenjie DOU ; Li ZHANG ; Shujuan ZHEN
Chinese Journal of Nephrology 2018;34(12):900-908
Objective To evaluate the efficacy and safety of mycophenolate mofetil (MMF) in treatment of IgA nephropathy. Methods The Cochrane library, PubMed, EMBASE, Wanfang Data Knowledge Service Platform, CNKI and VIP were searched from the time when the databases were established to March 31, 2018. Reports on randomized controlled trials (RCTs) on treating IgAN with MMF were collected. Data were extracted and assessed independently by three reviewers and the methodological quality of included RCTs was assessed by the Cochrane collaboration's tool for assessing risk of bias. The Meta analysis of homogeneous RCTs was managed by using Stata 12.0. Results Nine RCTs, of which two RCTs were assessed as A-level studies scoring from 4 to 7 points, six RCTs were assessed as B-level studies scoring from 2 to 3 points, and one RCT was assessed as C-level study with scores less than 2 points, were enrolled in the study. Important outcomes of this systematic review were described as follows: (1) Compared to placebo plus ACEI/ARB or ACEI/ARB monotherapy, MMF plus ACEI/ARB did not reduce the incidence of increased serum creatinine and ESRD, but increased the partial remission rate of urinary protein (OR=2.59, 95%CI 1.01-6.65, P=0.049. (2) No significant difference was detected in the efficacy of reducing urinary protein for MMF monotherapy or MMF plus glucocorticoid (GC) compared to GC monotherapy. (3) MMF showed no significant difference in the efficacy of reducing urinary protein compared to LEF or CTX, but lower incidence rate of serum creatinine increasing than that of CTX group (OR=0.21, 95%CI 0.04-1.07, P=0.043. (4) Different levels of adverse reactions occurred in each treatment group with MMF, but most symptoms were mild, and recovered gradually after reducing or withdrawing MMF. Conclusions MMF monotherapy shows a superiority in curing IgAN compared to ACEI/ARB, but no significant superiority compared to GC. MMF can replace a part of the effect of GC when used in combination with GC and can reduce the dosage of GC compared to GC monotherapy. Additionally, MMF displays no better short-term efficacy than LEF or CTX, but a better long-term efficacy and fewer side effects than CTX. And the side effects occurred in the treatment groups with MMF are mostly mild, and disappear gradually after reducing or stopping the use of the drug. MMF is a safe and effective drug for the treatment of IgAN.
8. Ventilator-associated pneumonia among premature infants <34 weeks′ gestational age in neonatal intensive care unit in China: a multicenter study
Shujuan LI ; Weili YAN ; Qi ZHOU ; Shuping HAN ; Jinzhen GUO ; Shiwen XIA ; Shah VIBHUTI ; Sannan WANG ; Yong JI ; Changyi YANG ; Chuanzhong YANG ; Ruobing SHAN ; Ling LIU ; Bin YI ; Jiangqin LIU ; Zhenlang LIN ; Yang WANG ; Ling HE ; Mingxia LI ; Xinnian PAN ; Yan GUO ; Ling CHEN ; Cuiqing LIU ; Qin ZHOU ; Xiaoying LI ; Hong XIONG ; Yujie QI ; Mingyan HEI ; Yun CAO ; Siyuan JIANG ; Yi ZHANG ; K. Lee SHOO
Chinese Journal of Pediatrics 2017;55(3):182-187
Objective:
To investigate the incidence and pathogen distribution of ventilator-associated pneumonia (VAP) among preterm infants admitted to level Ⅲ neonatal intensive care units (NICU) in China.
Method:
A prospective study was conducted in 25 level Ⅲ NICU, enrolling all preterm infants <34 weeks gestational age admitted to the participating NICU within the first 7 days of life from May 2015 to April 2016. Chi-square test,
9.Expression of polo-like kinase 1 in human renal cell carcinoma and impact of BI2536 on the cell proliferation of renal cell carcinoma A498 cell line
Yaolei LIU ; Shujuan QIN ; Jizheng WANG
Chinese Journal of Urology 2016;37(3):219-222
Objective To investigate the expression of Polo-like kinase 1 in renal clear cell carcinoma and tissue adjacent to carcinoma;impact of BI2536 on the cell proliferation of renal clear cell carcinoma A498 cell line.Methods We select 12 cases of renal cancer Specimens of randical surgery between January 2013 and December 2014.The study included 7 male patients and 5 female patients,whose age ranged from 41 to 68 years(mean 49 years).Tumors were single and the location of tumor included 5 in left kidney,7 in right kidney.The size of renal tumor ranged from 2.1 to 6.3 cm.All patients did not have radiotherapy and chemotherapy preoperative who have no local and distant matastasis.The pathological results demonstrated renal clear cell carcinoma in 12 cases.At the same time,we collect the tissue 2 centimeters away as control,which pathological results demonstrated normal tissue.The expression of PLK1 was detected by western bloting in tissues from 12 cases of renal clear cell carcinoma and tissue adjacent to carcinoma and quantitative analysis was made.Cell proliferation of A498 cell line at the different concentrations of BI2536 were assayed by flow cytometry (0,20,40,60μg/L).Results The expression of PLK1 in renal clear cell carcinoma tissue are 0.74 ±0.2 and 0.21 ±0.13.The carcinoma tissue is higher than tissue adjacent to carcinoma (P =0.02).BI2536 act on A498 after 48 hours,the A498 cell number were arrested at G2/M phase at 0μg/L,20μg/L,40μg/L and 60μg/L were (10.28 ± 0.47) %,(14.35 ± 0.85) %,(20.49 ± 0.78) % and (23.90 ± 0.54) %,respectively.The A498 cell number were arrested at G2/M phase increase when we incearse the concentrations of BI2536 at 48 hours (P < 0.05).Conclusions The higher expression of PLK1 in renal clear cell carcinoma and the proliferation of the renal clear carcinoma cell can be repressed by BI2536 both reveal PLK1 may be used as the molecular maker and therapeutics target of renal clear cell carcinoma.
10.Cytotoxicity in Vitro of a Noval Ni-free ZrCuFeAlAg Bulk Metallic Glass.
Huifang PANG ; Cong XU ; Hua QIN ; Demin LI ; Peiyuan LI ; Bo WANG ; Shujuan ZHANG ; Qiu ZHAO
Journal of Biomedical Engineering 2015;32(2):380-386
This paper is to evaluate the biocompatibility and cytotoxicity of a new Ni-free Zr-based bulk metallic glass (BMG), Zr60.14 Cu22.31 Fe4.85 Al9.7 Ag3, by comparing it with conventional Ti6Al4V alloy. According to ISO 10993-5: 1999 and GB/T 16886.5-1997 standards, Zr60.14 Cu22.31 Fe4.85 Al9.7 Ag3, pure Zr and Ti6Al4V materials were extracted with surface area of sample/volume of medium ratio being 1 cm2/mL and 0.5 cm2/mL, respectively. The viabilities of MG-63 cells (Human osteosarcoma cell line) cultured in the BMG medium extracts for 1, 3 and 5 days were determined by CCK-8 assay. The cellular morphology of MG-63 cells cultured on the surface of samples for 3 days was tested through laser scanning confocal microscopy (LSCM) and scanning electron microscopy (SEM). The relative growth rate (RGR) of MG-63 cells cultured in Zr60.14 Cu22.31 Fe4.85 Al9.7 Ag3 and pure Zr were both more than 85%, indicating that the cytotoxicity of BMG was relatively low and met the national biomedical material eligibility standard. There was insignificant difference in the morphology of MG-63 cells cultured in the BMG medium extracts and the control group through LSCM and SEM, which showed the BMG had excellent biological compatibility. The Zr-based bulk metallic glass Zr60.14 Cu22.31 Fe4.85 Al9.7 Ag3 and the conventional Ti6Al4V alloy both had no obvious cytotoxicity to MG-63 cells. These results provided evidence that the new Zr-based bulk metallic glass could be potential replacement material for the orthopedic surgical implant.
Alloys
;
Biocompatible Materials
;
Cell Line
;
Glass
;
Humans
;
Microscopy, Electron, Scanning
;
Nickel
;
Titanium
;
Zirconium

Result Analysis
Print
Save
E-mail