1.A qualitative study on the causes of delayed decisions to seek medical attention among patients with ischemic stroke
Xue LI ; Kaili FAN ; Shouping GONG
Chinese Medical Ethics 2025;38(5):596-601
		                        		
		                        			
		                        			ObjectiveTo learn the inner experience of decisions to seek medical attention among patients with ischemic stroke and to explore the factors that affect patients’ early decisions to seek medical attention, providing a basis for formulating intervention measures to reduce patient delays. MethodsUsing qualitative research methods, semi-structured in-depth interviews were conducted with 24 patients with ischemic stroke who had delayed seeking medical attention through purposive sampling, and the data were analyzed by category analysis method. ResultsThe five major themes that affected ischemic stroke patients’ decisions to seek medical attention were symptom experience (insufficient attention to disease and the impact of symptoms on the patients), symptom assessment (symptom perception, symptom interpretation, and symptom recognition), symptom response (psychological denial and self-relief), prior knowledge of the diseases (deficient knowledge and stroke experience), as well as environmental-social factors (morbidity context, external information support, and medical insurance). ConclusionUnder the guidance of cognitive, psychosocial, and environmental frameworks, targeted intervention strategies should be proposed to reduce the incidence of delayed decisions to seek medical attention among patients with ischemic stroke. 
		                        		
		                        		
		                        		
		                        	
2.Discussion on the Social Return after the Outbreak of COVID -19
Shouping GONG ; U Jianrui LY ; Honghong PEI ; Huiyun YANG ; Erdi XU ; Rong WANG ; Ruizhi WANG ; Huqing WANG ; Longhui FU
Chinese Medical Ethics 2024;35(5):568-572
		                        		
		                        			
		                        			After COVID -19, patients, medical workers and the whole society in COVID -19 were faced with the challenge of how to quickly return to normal life. Patients cured in COVID -19 would face mental or psychological barriers, or be discriminated against, or face problems such as overweight of local epidemic prevention policies. The front-line medical personnel experienced job burnout and a variety of mental and psychological disorders, with some even developing physical symptoms. During the epidemic, ordinary people were in a state of psychological stress, education, production and economic activities were affected, and the incidence of mental or psychological disorders increases. It was necessary to provide COVID -19 patients with mental health monitoring and counseling. Give professional guidance to front-line medical staff, arrange rotation reasonably, and pay attention to their mental health status. Local governments should strictly implement the national epidemic prevention system, formulate epidemic prevention policies with humanistic care, actively publicize epidemic related knowledge and safeguard the rights and interests of the people.
		                        		
		                        		
		                        		
		                        	
3.Study on Automatic Plan Method for Radiotherapy after Breast-conserving Surgery Based on TiGRT System.
Chuanbin XIE ; Xiangkun DAI ; Hongfeng SHEN ; Gaoxiang CHEN ; Haiyang WANG ; Ruigang GE ; Hanshun GONG ; Tao YANG ; Shouping XU ; Gaolong ZHANG ; Baolin QU
Chinese Journal of Medical Instrumentation 2022;46(1):108-113
		                        		
		                        			
		                        			To study an automatic plan(AP) method for radiotherapy after breast-conserving surgery based on TiGRT system and and compare with manual plan (MP). The dosimetry parameters of 10 patients and the evaluation of scoring table were analyzed, it was found that the targets dose of AP were better than that of MP, but there was no statistical difference except for CI, The V5, V20 and V30 of affected lungs and whole lungs in AP were lower than all that in MP, the Dmean of hearts was slightly higher than that of MP, but the difference was not statistically significant, the MU of AP was increase by 16.1% compared with MP, the score of AP evaluation was increase by 6.1% compared with MP. So the AP could be programmed and automated while ensuring the quality of the plan, and can be used to design the plans for radiotherapy after breast-conserving surgery.
		                        		
		                        		
		                        		
		                        			Breast Neoplasms/surgery*
		                        			;
		                        		
		                        			Female
		                        			;
		                        		
		                        			Humans
		                        			;
		                        		
		                        			Mastectomy, Segmental
		                        			;
		                        		
		                        			Organs at Risk
		                        			;
		                        		
		                        			Radiotherapy Dosage
		                        			;
		                        		
		                        			Radiotherapy Planning, Computer-Assisted
		                        			;
		                        		
		                        			Radiotherapy, Intensity-Modulated
		                        			
		                        		
		                        	
4.Discussion on the Social Return after the Outbreak of COVID -19
Shouping GONG ; U Jianrui LY ; Honghong PEI ; Huiyun YANG ; Erdi XU ; Rong WANG ; Ruizhi WANG ; Huqing WANG ; Longhui FU
Chinese Medical Ethics 2022;35(5):568-572
		                        		
		                        			
		                        			After COVID -19, patients, medical workers and the whole society in COVID -19 were faced with the challenge of how to quickly return to normal life. Patients cured in COVID -19 would face mental or psychological barriers, or be discriminated against, or face problems such as overweight of local epidemic prevention policies. The front-line medical personnel experienced job burnout and a variety of mental and psychological disorders, with some even developing physical symptoms. During the epidemic, ordinary people were in a state of psychological stress, education, production and economic activities were affected, and the incidence of mental or psychological disorders increases. It was necessary to provide COVID -19 patients with mental health monitoring and counseling. Give professional guidance to front-line medical staff, arrange rotation reasonably, and pay attention to their mental health status. Local governments should strictly implement the national epidemic prevention system, formulate epidemic prevention policies with humanistic care, actively publicize epidemic related knowledge and safeguard the rights and interests of the people.
		                        		
		                        		
		                        		
		                        	
5.Advances in magnetic resonance imaging guided radiation therapy.
Wenzhe XU ; Changjian WANG ; Yiming MA ; Chunfeng FANG ; Hanshun GONG ; Gaolong ZHANG ; Baolin QU ; Shouping XU
Journal of Biomedical Engineering 2021;38(1):161-168
		                        		
		                        			
		                        			Image-guided radiation therapy using magnetic resonance imaging (MRI) is a new technology that has been widely studied and developed in recent years. The technology combines the advantages of MRI imaging, and can offer online real-time tracking of tumor and adjacent organs at risk, as well as real-time optimization of radiotherapy plan. In order to provide a comprehensive understanding of this technology, and to grasp the international development and trends in this field, this paper reviews and summarizes related researches, so as to make the researchers and clinical personnel in this field to understand recent status of this technology, and carry out corresponding researches. This paper summarizes the advantages of MRI and the research progress of MRI linear accelerator (MR-Linac), online guidance, adaptive optimization, and dosimetry-related research. Possible development direction of these technologies in the future is also discussed. It is expected that this review can provide a certain reference value for clinician and related researchers to understand the research progress in the field.
		                        		
		                        		
		                        		
		                        			Magnetic Resonance Imaging
		                        			;
		                        		
		                        			Particle Accelerators
		                        			;
		                        		
		                        			Radiometry
		                        			;
		                        		
		                        			Radiotherapy Planning, Computer-Assisted
		                        			;
		                        		
		                        			Radiotherapy, Image-Guided
		                        			
		                        		
		                        	
6. Evaluation of plan quality for IMPT and VMAT in the treatment of patients with prostate cancer
Tao YANG ; Shouping XU ; Chuanbin XIE ; Xuan GONG ; Wei XU ; Baolin QU ; Zishen WANG ; Chunfeng FANG ; Lin CAO
Chinese Journal of Radiological Medicine and Protection 2020;40(1):19-25
		                        		
		                        			 Objective:
		                        			To study the dosimetric characteristics and plan quality of PTV-based intensity modulated proton radiotherapy (IMPT) and volumetric-modulated arc therapy (VMAT) plans for prostate cancer, so as to provide a reference for clinical application.
		                        		
		                        			Methods:
		                        			A total of 10 prostate cancer cases were included in this retrospective study. IMPT and RapidArc plans were designed by RayStation and Eclipse TPS based on PTV, respectively. For each case, IMPT plans were generated using multiple field optimization (MFO) technique with two parallel-opposed lateral fields, whereas RapidArc plans were generated using double-arc technique (two full arcs). Final dose calculation of IMPT was conducted by pencil beam(PB) and Monte Carlo (MC) algorithm, respectively, with adopted data model from the pencil beam scanning (PBS) proton therapy system of IBA Protues Plus(IBA Group, Belgium); The data model originated from the linear accelerator of Varian Clinac iX (Varian Medical Systems, America) was used for RapidArc plans. Dosimetric parameters of DVH and dose distribution were used to compare the dose differences in targets and organs at risk (OARs) between these two treatment techniques.
		                        		
		                        			Results:
		                        			For targets, HIs of PB-IMPT and MC-IMPT were slightly better than that of RapidArc , but CI of IMPT was slightly lower than that of RapidArc; 
		                        		
		                        	
7.Acceptance tests of beam performance for pencil beam scanning (PBS) proton system of IBA
Tao YANG ; Baolin QU ; Shouping XU ; Chuanbin XIE ; Wei XU ; Xuan GONG ; Lin CAO
Chinese Journal of Radiation Oncology 2020;29(12):1075-1079
		                        		
		                        			
		                        			Objective:To explore the beam performance of GTR 360° PBS dedicated nozzle for IBA Proteus Plus proton system and evaluate the beam characteristics of PBS during acceptance test procedure (ATP) to meet the precision and safety requirements of clinical treatment.Methods:According to the requirements of acceptance tests, the beam tests of PBS mainly included: test of integrated depth dose (IDD), test of maximum field size at the maximum and minimum ranges, field uniformity and informative PBS tests for the GTR 360°, test of lateral dose uniformity in a single field uniform dose in a cube, test of longitudinal dose uniformity in a single field uniform dose in a cube, and test of monitor unit reproducibility and proportionality.Results:The maximum deviation measured of range, fall back accuracy and distal fall-off was 0.03 g/m 2, 0.01 g/m 2 and 0.078 g/m 2, respectively. Maximum field size at the maximum and minimum ranges was 30.2 cm×40.2 cm and 30.1 cm×40.1 cm, respectively. During the different gantry angles and ranges, the lowest γ passing rate of a pattern plan was 97%, the maximum deviation of the centrical beam spot size at the X and Y axes was -0.16 mm and -0.21 mm, and the worst symmetry was 0.80%. Compared with the centrical beam spot, the maximum size deviation of the other beam spots was 0.11 mm and 0.14 mm at the X and Y axes, and the maximum position accuracy deviation of the beam spot was 0.60 mm and 0.43 mm at the X and Y axes. The maximum deviation of lateral dose uniformity at at the X and Y axes was 0.55% and 0.80% in the high energy region, and 0.6% and 0.75% in the low energy region. The maximum deviation of longitudinal dose uniformity was 0.79% in the high energy region, and 2.22% in the low energy region. The monitor unit (MU) reproducibility factor was 0.106% and the maximum proportionality deviation was 0.67%. Conclusion:The dedicated nozzle of PBS has passed all the beam performance acceptance tests, which meet the requirements of all parameters, and the whole system yields relatively high accuracy, repeatability and good stability.
		                        		
		                        		
		                        		
		                        	
8.Acceptance Test and Image Quality Assurance of MRI Simulator Equipment.
Hanshun GONG ; Shouping XU ; Wei XU ; Shuxin WANG ; Xiangkun DAI ; Baolin QU
Chinese Journal of Medical Instrumentation 2018;42(6):455-459
		                        		
		                        			
		                        			MRI simulator(MRI-Sim) images have unique clinical advantages with higher resolution of soft tissue and clearer visualization of tissue boundaries. Thus, the precise positioning of the tumor target area can be achieved and it is widely used in the field of radiotherapy. This article focuses on the acceptance test project and image quality assurance work of MRI-Sim equipment. The obtained ACR phantom images were used to analyze various image quality assurance indicators, and the results all reached the set standards, thereby ensuring that the obtained images meet the requirements of clinical applications.
		                        		
		                        		
		                        		
		                        			Magnetic Resonance Imaging
		                        			;
		                        		
		                        			Phantoms, Imaging
		                        			;
		                        		
		                        			Quality Assurance, Health Care
		                        			
		                        		
		                        	
9.Evaluation of plan quality between two treatment planning systems for volumetric modulated arc therapy
Tao YANG ; Wei XU ; Shouping XU ; Baolin QU ; Ruigang GE ; Xiangkun DAI ; Chuanbin XIE ; Xiaohu CONG ; Xuan GONG
Chinese Journal of Radiation Oncology 2017;26(10):1192-1198
		                        		
		                        			
		                        			Objective To investigate the plan quality between two treatment planning systems (TPSs) for volumetric modulated arc therapy (VMAT). Methods VMAT plans based on Varian Eclipse and Philips Pinnacle TPS were designed for 10 cervical cancer patients (2, 3 Arcs) and 10 prostate cancer patients ( 1, 2 Arcs) . The delivery system of VMAT was Varian ClinaciX machine, and RapidArc was used. The treatment plan quality between the two TPSs was evaluated based on dose distribution, delivery efficiency, and parameter settings. The differences between the two TPSs were compared using paired t-test. Results For cervical cancer patients, the 2-Arc VMAT plans based on the Pinnacle was slightly better than those based on the Eclipse in terms of the conformal index ( CI) of planning target volume ( PTV) , rectum V30 and V40 , and bladder V30 and V40 , and the homogeneity index ( HI) of PTV and PTV1 as well as CI of PTV1 in the Eclips were slightly better than those in the Pinnacle( P<005) Pinnacle were slightly worse than those in the Eclipse ( P>005) . The number of monitor units with 2-Arcs and 3-Arcs plans of the Eclipse was significantly smaller than those in the Pinnacle (P<005). For prostate cancer patients, The 1-arc VMAT plans of the Pinnacle TPS were slightly superior to those of the Eclipse TPS in terms of the HI of PTV, rectumV30 and V40 , and bladderV30 and V40 , but the former was slight inferior to the latter in terms of the CI of PTV (P<005). The number of monitor units of 1-arc and 2-Arcs plans showed no significant difference between the two TPSs (P>005). Conclusions For patients with cervical cancer and prostate cancer, the VMAT plans based on Varian Eclipse and Philips Pinnacle TPS can achieve a clinically acceptable dose distribution and show a little difference in the treatment plan quality. However, we will still need more cases to further study and determine the performance characteristics of the commercial TPSs for optimizing VMAT.
		                        		
		                        		
		                        		
		                        	
10.Accuracy of Dose Calculation with CBCT Images under Different Scanning Conditions
Hanshun GONG ; Shouping XU ; Wei XU ; Tao YANG ; Xiaohu CONG ; Ruigang GE ; Chuanbin XIE
Chinese Journal of Medical Instrumentation 2017;41(2):146-149
		                        		
		                        			
		                        			The treatment plans were designed based on planning CT of Catphan phantom's homogenic and heterogenetical module, respectively. With the OBI system, Catphan phantom was scanned under different scanning conditions. The dose was recalculated by applying treatment plans based on planning CT to the CBCT images with its individual hounsfield unit-electron density calibration curve. The dose distributions were compared with those of the original plan, the results ofHI showed a good agreement.CIs in the homogenic module were superior to those in the heterogenetical one. There is a good dose distribution for CBCT images under different scanning conditions. It is helpful for CBCT images directly used for dose re-calculation in adaptive radiation therapy (ART).
		                        		
		                        		
		                        		
		                        	
            
Result Analysis
Print
Save
E-mail