1.Prediction of Screw Loosening After Dynamic Pedicle Screw Fixation With Lumbar Polyetheretherketone Rods Using Magnetic Resonance Imaging-Based Vertebral Bone Quality Score
Guozheng JIANG ; Luchun XU ; Yukun MA ; Jianbin GUAN ; Yongdong YANG ; Wenqing ZHONG ; Wenhao LI ; Shibo ZHOU ; JiaWei SONG ; Ningning FENG ; Ziye QIU ; Zeyu LI ; YiShu ZHOU ; Letian MENG ; Yi QU ; Xing YU
Neurospine 2024;21(2):712-720
		                        		
		                        			 Objective:
		                        			To investigate the correlation between magnetic resonance imaging-based vertebral bone quality (VBQ) score and screw loosening after dynamic pedicle screw fixation with polyetheretherketone (PEEK) rods, and evaluate its predictive value. 
		                        		
		                        			Methods:
		                        			A retrospective analysis was conducted on the patients who underwent dynamic pedicle screw fixation with PEEK rods from March 2017 to June 2022. Data on age, sex, body mass index, hypertension, diabetes, hyperlipidemia history, long-term smoking, alcohol consumption, VBQ score, L1–4 average Hounsfield unit (HU) value, surgical fixation length, and the lowest instrumented vertebra were collected. Logistic regression analysis was employed to assess the relationship between VBQ score and pedicle screw loosening (PSL). 
		                        		
		                        			Results:
		                        			A total of 24 patients experienced PSL after surgery (20.5%). PSL group and non-PSL group showed statistical differences in age, number of fixed segments, fixation to the sacrum, L1–4 average HU value, and VBQ score (p < 0.05). The VBQ score in the PSL group was higher than that in the non-PSL group (3.56 ± 0.45 vs. 2.77 ± 0.31, p < 0.001). In logistic regression analysis, VBQ score (odds ratio, 3.425; 95% confidence interval, 1.552–8.279) were identified as independent risk factors for screw loosening. The area under the receiver operating characteristic curve for VBQ score predicting PSL was 0.819 (p < 0.05), with the optimal threshold of 3.15 (sensitivity, 83.1%; specificity, 80.5%). 
		                        		
		                        			Conclusion
		                        			The VBQ score can independently predict postoperative screw loosening in patients undergoing lumbar dynamic pedicle screw fixation with PEEK rods, and its predictive value is comparable to HU value. 
		                        		
		                        		
		                        		
		                        	
2.Prediction of Screw Loosening After Dynamic Pedicle Screw Fixation With Lumbar Polyetheretherketone Rods Using Magnetic Resonance Imaging-Based Vertebral Bone Quality Score
Guozheng JIANG ; Luchun XU ; Yukun MA ; Jianbin GUAN ; Yongdong YANG ; Wenqing ZHONG ; Wenhao LI ; Shibo ZHOU ; JiaWei SONG ; Ningning FENG ; Ziye QIU ; Zeyu LI ; YiShu ZHOU ; Letian MENG ; Yi QU ; Xing YU
Neurospine 2024;21(2):712-720
		                        		
		                        			 Objective:
		                        			To investigate the correlation between magnetic resonance imaging-based vertebral bone quality (VBQ) score and screw loosening after dynamic pedicle screw fixation with polyetheretherketone (PEEK) rods, and evaluate its predictive value. 
		                        		
		                        			Methods:
		                        			A retrospective analysis was conducted on the patients who underwent dynamic pedicle screw fixation with PEEK rods from March 2017 to June 2022. Data on age, sex, body mass index, hypertension, diabetes, hyperlipidemia history, long-term smoking, alcohol consumption, VBQ score, L1–4 average Hounsfield unit (HU) value, surgical fixation length, and the lowest instrumented vertebra were collected. Logistic regression analysis was employed to assess the relationship between VBQ score and pedicle screw loosening (PSL). 
		                        		
		                        			Results:
		                        			A total of 24 patients experienced PSL after surgery (20.5%). PSL group and non-PSL group showed statistical differences in age, number of fixed segments, fixation to the sacrum, L1–4 average HU value, and VBQ score (p < 0.05). The VBQ score in the PSL group was higher than that in the non-PSL group (3.56 ± 0.45 vs. 2.77 ± 0.31, p < 0.001). In logistic regression analysis, VBQ score (odds ratio, 3.425; 95% confidence interval, 1.552–8.279) were identified as independent risk factors for screw loosening. The area under the receiver operating characteristic curve for VBQ score predicting PSL was 0.819 (p < 0.05), with the optimal threshold of 3.15 (sensitivity, 83.1%; specificity, 80.5%). 
		                        		
		                        			Conclusion
		                        			The VBQ score can independently predict postoperative screw loosening in patients undergoing lumbar dynamic pedicle screw fixation with PEEK rods, and its predictive value is comparable to HU value. 
		                        		
		                        		
		                        		
		                        	
3.Immediate implantation of simple taper retentive implants in chronic apical infected teeth in the posterior region:a 5-year clinical observation
Xu ZHANG ; Shibo WEI ; Fei YU ; Hao WU ; Liangwei CAO ; Ning CAO ; Hongwu WEI ; Shuigen GUO
West China Journal of Stomatology 2024;42(6):764-772
		                        		
		                        			
		                        			Objective This study aims to evaluate the mid-and long-term clinical efficacies of simple taper retentive implants for immediate placement in chronic apical infected teeth in the posterior region.Methods A total of 36 pa-tients with 41 simple taper retentive implants were included in the study conducted.These patients underwent immediate implant treatment for teeth with chronic apical infection in the posterior region.The soft and hard tissues surrounding the implants were assessed and documented over a period of 5 years following the completion of crown restoration.Re-sults During the 5 years follow-up period,one implant failed with mobility,and the implant survival rate was 97.6%.The mean marginal bone resorption was(-0.74±1.03)mm from the immediate post-implant placement to the immediate post-crown restoration,and the difference in marginal bone heights between the two time points was statistically signifi-cant(P<0.05).The mean marginal bone resorption was(-0.21±0.70)mm from the immediate post-crown restoration to the 5-year post-crown restoration,and the difference in marginal bone height between the two time points was not statisti-cally significant(P>0.05).No significant difference(P>0.05)was observed in bone resorption between mesial and distal,maxillary and mandibular,different tooth posi-tions,and different implant lengths.The soft tissue sur-rounding the implants remained healthy at the 5 years follow-up period,one implant exhibited peri-implantitis,and no mechanical complications were observed.The overall satisfaction of patients was good.Conclusion Immediate place-ment of simple taper retentive implants after thorough debridement of chronic infected alveolar socket in the posterior re-gion can achieve good mid-and long-term clinical outcomes after 5 years of loading.The soft and hard tissues were maintained in a steady state,which expanded the indications for immediate implantation.
		                        		
		                        		
		                        		
		                        	
4.Decision tree-enabled establishment and validation of intelligent verification rules for blood analysis results
Linlin QU ; Xu ZHAO ; Liang HE ; Yehui TAN ; Yingtong LI ; Xianqiu CHEN ; Zongxing YANG ; Yue CAI ; Beiying AN ; Dan LI ; Jin LIANG ; Bing HE ; Qiuwen SUN ; Yibo ZHANG ; Xin LYU ; Shibo XIONG ; Wei XU
Chinese Journal of Laboratory Medicine 2024;47(5):536-542
		                        		
		                        			
		                        			Objective:To establish a set of artificial intelligence (AI) verification rules for blood routine analysis.Methods:Blood routine analysis data of 18 474 hospitalized patients from the First Hospital of Jilin University during August 1st to 31st, 2019, were collected as training group for establishment of the AI verification rules,and the corresponding patient age, microscopic examination results, and clinical diagnosis information were collected. 92 laboratory parameters, including blood analysis report parameters, research parameters and alarm information, were used as candidate conditions for AI audit rules; manual verification combining microscopy was considered as standard, marked whether it was passed or blocked. Using decision tree algorithm, AI audit rules are initially established through high-intensity, multi-round and five-fold cross-validation and AI verification rules were optimized by setting important mandatory cases. The performance of AI verification rules was evaluated by comparing the false negative rate, precision rate, recall rate, F1 score, and pass rate with that of the current autoverification rules using Chi-square test. Another cohort of blood routine analysis data of 12 475 hospitalized patients in the First Hospital of Jilin University during November 1sr to 31st, 2023, were collected as validation group for validation of AI verification rules, which underwent simulated verification via the preliminary AI rules, thus performance of AI rules were analyzed by the above indicators. Results:AI verification rules consist of 15 rules and 17 parameters and do distinguish numeric and morphological abnormalities. Compared with auto-verification rules, the true positive rate, the false positive rate, the true negative rate, the false negative rate, the pass rate, the accuracy, the precision rate, the recall rate and F1 score of AI rules in training group were 22.7%, 1.6%, 74.5%, 1.3%, 75.7%, 97.2%, 93.5%, 94.7%, 94.1, respectively.All of them were better than auto-verification rules, and the difference was statistically significant ( P<0.001), and with no important case missed. In validation group, the true positive rate, the false positive rate, the true negative rate, the false negative rate, the pass rate, the accuracy, the precision rate, the recall rate and F1 score were 19.2%, 8.2%, 70.1%, 2.5%, 72.6%, 89.2%, 70.0%, 88.3%, 78.1, respectively, Compared with the auto-verification rules, The false negative rate was lower, the false positive rate and the recall rate were slightly higher, and the difference was statistically significant ( P<0.001). Conclusion:A set of the AI verification rules are established and verified by using decision tree algorithm of machine learning, which can identify, intercept and prompt abnormal results stably, and is moresimple, highly efficient and more accurate in the report of blood analysis test results compared with auto-vefication.
		                        		
		                        		
		                        		
		                        	
5.Efficacy and safety of neoadjuvant therapy with TCbHP regimen for human epidermal growth factor receptor 2-positive breast cancer
Donghong XU ; Xiangdong WU ; Shibo ZHANG ; Yongtao DU ; Chongzhu HU ; Enqing WANG
Cancer Research and Clinic 2024;36(8):590-593
		                        		
		                        			
		                        			Objective:To investigate the efficacy and safety of neoadjuvant therapy with trastuzumab and pertuzumab combined with taxane and platinum drugs (TCbHP) regimen for human epidermal growth factor receptor 2 (HER2)-positive breast cancer.Methods:A retrospective case series study was conducted. The clinical data of HER2-positive breast cancer patients who received neoadjuvant therapy with 21-day TCbHP regimen and completed subsequent surgery in 11 tertiary-level hospitals in Hebei Province from June 2019 to December 2021 were retrospectively analyzed, and the total pathological complete remission (tpCR) rate, the incidence of grade ≥3 adverse events, and the completion rate of the established regimen were statistically analyzed.Results:A total of 78 female patients were included and the median age [ M ( Q1, Q3)] was 54.0 years (48.5 years, 57.5 years). The tpCR rate was 64.1% (50/78). Subgroup analysis showed that the tpCR rate in the HER2 immunohistochemistry (IHC)+++ group was higher than that in the HER2 IHC++ and fluorescence in situ hybridization-positive group [68.6% (48/70) vs. 25.0% (2/8)], and the difference was statistically significant ( χ2 = 4.18, P = 0.041); the tpCR rate in the hormone-receptor negative group was higher than that in the hormone-receptor positive group [81.8% (27/33) vs. 51.1% (23/45)], and the difference was statistically significant ( χ2 = 7.80, P = 0.005); the tpCR rate in the albumin-bound paclitaxel group was higher than that in the docetaxel group [72.3% (34/47) vs. 48.3% (14/29)], and the difference was statistically significant ( χ2 = 4.46, P = 0.035). The incidence of ≥ grade 3 adverse reactions was 12.8% (10/78) in 78 patients, and the completion rate of the established regimen was 92.3% (72/78). Conclusions:Neoadjuvant therapy with TCbHP regimen for HER2-positive breast cancer shows a definite efficacy, good safety and tolerance.
		                        		
		                        		
		                        		
		                        	
6.Prediction of Screw Loosening After Dynamic Pedicle Screw Fixation With Lumbar Polyetheretherketone Rods Using Magnetic Resonance Imaging-Based Vertebral Bone Quality Score
Guozheng JIANG ; Luchun XU ; Yukun MA ; Jianbin GUAN ; Yongdong YANG ; Wenqing ZHONG ; Wenhao LI ; Shibo ZHOU ; JiaWei SONG ; Ningning FENG ; Ziye QIU ; Zeyu LI ; YiShu ZHOU ; Letian MENG ; Yi QU ; Xing YU
Neurospine 2024;21(2):712-720
		                        		
		                        			 Objective:
		                        			To investigate the correlation between magnetic resonance imaging-based vertebral bone quality (VBQ) score and screw loosening after dynamic pedicle screw fixation with polyetheretherketone (PEEK) rods, and evaluate its predictive value. 
		                        		
		                        			Methods:
		                        			A retrospective analysis was conducted on the patients who underwent dynamic pedicle screw fixation with PEEK rods from March 2017 to June 2022. Data on age, sex, body mass index, hypertension, diabetes, hyperlipidemia history, long-term smoking, alcohol consumption, VBQ score, L1–4 average Hounsfield unit (HU) value, surgical fixation length, and the lowest instrumented vertebra were collected. Logistic regression analysis was employed to assess the relationship between VBQ score and pedicle screw loosening (PSL). 
		                        		
		                        			Results:
		                        			A total of 24 patients experienced PSL after surgery (20.5%). PSL group and non-PSL group showed statistical differences in age, number of fixed segments, fixation to the sacrum, L1–4 average HU value, and VBQ score (p < 0.05). The VBQ score in the PSL group was higher than that in the non-PSL group (3.56 ± 0.45 vs. 2.77 ± 0.31, p < 0.001). In logistic regression analysis, VBQ score (odds ratio, 3.425; 95% confidence interval, 1.552–8.279) were identified as independent risk factors for screw loosening. The area under the receiver operating characteristic curve for VBQ score predicting PSL was 0.819 (p < 0.05), with the optimal threshold of 3.15 (sensitivity, 83.1%; specificity, 80.5%). 
		                        		
		                        			Conclusion
		                        			The VBQ score can independently predict postoperative screw loosening in patients undergoing lumbar dynamic pedicle screw fixation with PEEK rods, and its predictive value is comparable to HU value. 
		                        		
		                        		
		                        		
		                        	
7.Prediction of Screw Loosening After Dynamic Pedicle Screw Fixation With Lumbar Polyetheretherketone Rods Using Magnetic Resonance Imaging-Based Vertebral Bone Quality Score
Guozheng JIANG ; Luchun XU ; Yukun MA ; Jianbin GUAN ; Yongdong YANG ; Wenqing ZHONG ; Wenhao LI ; Shibo ZHOU ; JiaWei SONG ; Ningning FENG ; Ziye QIU ; Zeyu LI ; YiShu ZHOU ; Letian MENG ; Yi QU ; Xing YU
Neurospine 2024;21(2):712-720
		                        		
		                        			 Objective:
		                        			To investigate the correlation between magnetic resonance imaging-based vertebral bone quality (VBQ) score and screw loosening after dynamic pedicle screw fixation with polyetheretherketone (PEEK) rods, and evaluate its predictive value. 
		                        		
		                        			Methods:
		                        			A retrospective analysis was conducted on the patients who underwent dynamic pedicle screw fixation with PEEK rods from March 2017 to June 2022. Data on age, sex, body mass index, hypertension, diabetes, hyperlipidemia history, long-term smoking, alcohol consumption, VBQ score, L1–4 average Hounsfield unit (HU) value, surgical fixation length, and the lowest instrumented vertebra were collected. Logistic regression analysis was employed to assess the relationship between VBQ score and pedicle screw loosening (PSL). 
		                        		
		                        			Results:
		                        			A total of 24 patients experienced PSL after surgery (20.5%). PSL group and non-PSL group showed statistical differences in age, number of fixed segments, fixation to the sacrum, L1–4 average HU value, and VBQ score (p < 0.05). The VBQ score in the PSL group was higher than that in the non-PSL group (3.56 ± 0.45 vs. 2.77 ± 0.31, p < 0.001). In logistic regression analysis, VBQ score (odds ratio, 3.425; 95% confidence interval, 1.552–8.279) were identified as independent risk factors for screw loosening. The area under the receiver operating characteristic curve for VBQ score predicting PSL was 0.819 (p < 0.05), with the optimal threshold of 3.15 (sensitivity, 83.1%; specificity, 80.5%). 
		                        		
		                        			Conclusion
		                        			The VBQ score can independently predict postoperative screw loosening in patients undergoing lumbar dynamic pedicle screw fixation with PEEK rods, and its predictive value is comparable to HU value. 
		                        		
		                        		
		                        		
		                        	
8.Prediction of Screw Loosening After Dynamic Pedicle Screw Fixation With Lumbar Polyetheretherketone Rods Using Magnetic Resonance Imaging-Based Vertebral Bone Quality Score
Guozheng JIANG ; Luchun XU ; Yukun MA ; Jianbin GUAN ; Yongdong YANG ; Wenqing ZHONG ; Wenhao LI ; Shibo ZHOU ; JiaWei SONG ; Ningning FENG ; Ziye QIU ; Zeyu LI ; YiShu ZHOU ; Letian MENG ; Yi QU ; Xing YU
Neurospine 2024;21(2):712-720
		                        		
		                        			 Objective:
		                        			To investigate the correlation between magnetic resonance imaging-based vertebral bone quality (VBQ) score and screw loosening after dynamic pedicle screw fixation with polyetheretherketone (PEEK) rods, and evaluate its predictive value. 
		                        		
		                        			Methods:
		                        			A retrospective analysis was conducted on the patients who underwent dynamic pedicle screw fixation with PEEK rods from March 2017 to June 2022. Data on age, sex, body mass index, hypertension, diabetes, hyperlipidemia history, long-term smoking, alcohol consumption, VBQ score, L1–4 average Hounsfield unit (HU) value, surgical fixation length, and the lowest instrumented vertebra were collected. Logistic regression analysis was employed to assess the relationship between VBQ score and pedicle screw loosening (PSL). 
		                        		
		                        			Results:
		                        			A total of 24 patients experienced PSL after surgery (20.5%). PSL group and non-PSL group showed statistical differences in age, number of fixed segments, fixation to the sacrum, L1–4 average HU value, and VBQ score (p < 0.05). The VBQ score in the PSL group was higher than that in the non-PSL group (3.56 ± 0.45 vs. 2.77 ± 0.31, p < 0.001). In logistic regression analysis, VBQ score (odds ratio, 3.425; 95% confidence interval, 1.552–8.279) were identified as independent risk factors for screw loosening. The area under the receiver operating characteristic curve for VBQ score predicting PSL was 0.819 (p < 0.05), with the optimal threshold of 3.15 (sensitivity, 83.1%; specificity, 80.5%). 
		                        		
		                        			Conclusion
		                        			The VBQ score can independently predict postoperative screw loosening in patients undergoing lumbar dynamic pedicle screw fixation with PEEK rods, and its predictive value is comparable to HU value. 
		                        		
		                        		
		                        		
		                        	
9.Retrospective study on the types and characteristics of shock in polytrauma patients at different stages after trauma
Jialiu LUO ; Liangsheng TANG ; Deng CHEN ; Hai DENG ; Jingzhi YANG ; Teding CHANG ; Jing CHENG ; Huaqiang XU ; Miaobo HE ; Dongli WAN ; Feiyu ZHANG ; Mengfan WU ; Qingyun LIU ; Shibo WEI ; Wenguo WANG ; Gang YIN ; Zhaohui TANG
Chinese Journal of Emergency Medicine 2023;32(1):70-75
		                        		
		                        			
		                        			Objective:To investigate the types, incidences, and clinical characteristics of shock in polytrauma patients at different stages after polytrauma.Methods:A retrospective study was conducted on polytrauma patients admitted to multiple trauma centers from June 2020 to December 2021. The inclusion criteria were patients >18 years old and treated due to polytrauma. Exclusion criteria included an admission time of more than 48 h after trauma, a history of malignancy, or metabolic, consumptive, and immunological diseases. The early stage was defined as the period of ≤48 h after polytrauma, and the middle stage was defined as the period between 48 h and 14 days. The patient’s medical history, clinical manifestations, laboratory tests, imaging examination, injury severity score (ISS), and Glasgow coma scale (GCS) were collected. The types, incidences, and clinical characteristics of shock in different stages after polytrauma were analyzed, according to the diagnostic criteria of each type of shock. The differences between the groups were compared by Student’s t test, χ2 test or Mann-Whitney U test. Results:The incidence of the early and middle stage shock after polytrauma were 73.1% and 36.4%, respectively, with statistically significant difference between stages ( P<0.01). There were significant differences in the incidence of hypovolemic shock (83.6% vs. 28.4%), distributed shock (13.7% vs. 80.9%) and cardiogenic shock (3.5% vs. 6.6%) between stages (all P<0.05). The incidence of obstructive shock (8.4% vs. 9.7%, P>0.05) was similar between stages. The incidence of undifferentiated shock was 1.6% and 1.2%, respectively. There were 9.5% patients with multifactorial shock in the early stage and 14.4% in the middle stage. Totally 7 combinations of multifactorial shock were found in different stages after polytrauma. In the early stage, the combination of HS and DS accounted the highest ratio (42.3%) and followed by HS and OS for 28.8%. In the middle stage, the combination of HS and DS was the most common (48.6%) and followed by DS and OS (24.3%). Conclusions:The incidence of shock in polytrauma patients is high. Different types of shock can occur simultaneously or sequentially. Therefore a comprehensive resuscitation strategy is significant to improve the success rate of treatment.
		                        		
		                        		
		                        		
		                        	
10.A core epitope targeting antibody of SARS-CoV-2.
Simeng ZHAO ; Fengjiang LIU ; Shizhen QIU ; Qiaoshuai LAN ; Yiran WU ; Wei XU ; Junzi KE ; Jie YANG ; Xiaoyan LIU ; Kun WANG ; Hangtian GUO ; Shuai XIA ; Fangfang ZHANG ; Jiabei WANG ; Xiaowen HU ; Lu LU ; Shibo JIANG ; Suwen ZHAO ; Lianxin LIU ; Youhua XIE ; Xiuna YANG ; Haopeng WANG ; Guisheng ZHONG
Protein & Cell 2023;14(1):74-78
            
Result Analysis
Print
Save
E-mail