1.Design of speech command module for X-ray examination
Guoqing QIAO ; Shanxing OU ; Juncheng HUANG ; Panli LIU ; Cong LIU
Chinese Medical Equipment Journal 2017;38(2):56-58
		                        		
		                        			
		                        			Objective To design a speech command module to replace manual command during X-ray examination.Methods The module was composed of the parts for speech,pushbutton actuator,speaker,miniature voice box,power source and etc.The electrical conductors were used to connect the above parts,and the speech command was formed by special software.Results The module had the speech command triggered by the pushbutton,and the speech command was pellucid and clear so that the workload could be decreased.Conclusion The module facilitates the speech command during X-ray examination,and thus is worthy promoting practically.
		                        		
		                        		
		                        		
		                        	
2.CAD for identifying malignant lung nodules in early diagnosis: a survey.
Bin LI ; Lianfang TIAN ; Shanxing OU
Journal of Biomedical Engineering 2009;26(5):1141-1157
		                        		
		                        			
		                        			It is of paramount importance for the diagnosis and therapy of lung cancer, even for the increasing of 5-year survival rate in that the early dignosis of malignant pulmonary nodules are made by intelligent identification successfully. As it stands, in intelligent identification of pulmonary nodules, computer-aided detection/diagnosis (CAD) plays the most important role. The key points of intelligent identification of pulmonary nodules are (1) Detecting pulmonary nodules based on the characterization of nodule appearance; (2) Measuring accurately the nodule size; (3) Computing accurately the growth rate. This article presents a review on the basic technologies and methods of CAD for identifying malignant pulmonary nodules in the course of making early diagnosis, including lung segmentation, registration of volume data, identification of benign/malignant pulmonary nodule, and so on.
		                        		
		                        		
		                        		
		                        			Artificial Intelligence
		                        			;
		                        		
		                        			Diagnosis, Computer-Assisted
		                        			;
		                        		
		                        			methods
		                        			;
		                        		
		                        			Diagnosis, Differential
		                        			;
		                        		
		                        			Humans
		                        			;
		                        		
		                        			Lung Neoplasms
		                        			;
		                        		
		                        			diagnosis
		                        			;
		                        		
		                        			Radiographic Image Interpretation, Computer-Assisted
		                        			;
		                        		
		                        			Solitary Pulmonary Nodule
		                        			;
		                        		
		                        			diagnostic imaging
		                        			;
		                        		
		                        			Tomography, X-Ray Computed
		                        			;
		                        		
		                        			methods
		                        			
		                        		
		                        	
3.Experimental study of inductive apoptosis of Hep-6 in liver tumor cells line by magnetic nanoparticle encapsulated epirubicin
Shanxing OU ; Xiangsheng XIAO ; Huangwen LAI ; Jiang XIAN ; Jing YANG ; Jiangtao WANG ; Zenggui SU
Chinese Journal of Tissue Engineering Research 2003;7(20):2812-2813
		                        		
		                        			
		                        			Aim To investigate the effect of magnetic nanoparticleencapsulated epirubicin(MNPE) on inducing apoptosis of human liverHep-6 tumor cell line in vitro and provide new method for local ablation ofliver in order to improve survival period of patients and quality oflife. Methods Inductive apoptosis of nano-magnetic pharmoparticle toHep-6 tumor cell of primonary hepatic cell caner was investigated by DNAelectrophoresis, electron nicroscopy , and flow cytometry analysis. Theseitems were divided into three groups, control, drug-control, and grouptreated with magnetic nauoparticle encapsulated epirubicin. The changes ofhuman liver Hep-6 apoptosis induced by magnetic nanoparticle encapsu-lated epirubicin were observed on different time-point and with differentnanoparticle encapsulated epirubicin and control group of biaoroubixingwere divided into high-dosage and low-dosage group. And the ultimateconcentration of 10 mg/L and 100 mg/L were given respectively on hu-group was iucreased from 25% to 54% after 24 hours. The apoptosis ratein the experimental group, biaoroubixing group and control group was78%, 53% and 2% respectively after 36 hours. There was significantdifference( t = 3.05. P < 0.05) between the results of each group. Theapoptosis rate and quantity of medicine presented positive relativity withtime ( r = 0.96, P < 0.05 ) .Conclusion Magnetic nanopartiele encap-sulated epirubicin presents the advantages of slow degradation, release ofmagnetic nanoparticle system and better target and can induce apoptosis ofliver tumor Hep cell.
		                        		
		                        		
		                        		
		                        	
4.Digital Devices of Radiology Department and Lean Management
Fang YANG ; Gaocun DONG ; Liang XU ; Shanxing OU
Chinese Medical Equipment Journal 2003;0(10):-
		                        		
		                        			
		                        			Lean management theory is applied to the management of the devices and staffs of radiology department. With the current flow evaluated, the working efficiency and patient satisfaction are increased.
		                        		
		                        		
		                        		
		                        	
5.Quality Control of Spiral CT Scanning Work Procedure
Chinese Medical Equipment Journal 2003;0(10):-
		                        		
		                        			
		                        			The quality of CT diagnosis depends on the quality of scanning which is related to accurate scanning design and quality control on work process. The quality control of work procedure includes training of patients' breathing, reasonable application of window technique, accurate mark, size and CT value,washing and print of films. In addition, the coordination of clinical doctors, imaging doctors and CT technicians is very important. According to CT standards, precise CT scanning by CT design request, can provide a high quality CT images that reflect pathologic state of human body, thereby to raise the quality of CT diagnosis.
		                        		
		                        		
		                        		
		                        	
6.Discussion on CT's Maintenance and Radioprotection
Gaocun DONG ; Yanwu ZHANG ; Fang YANG ; Shanxing OU
Chinese Medical Equipment Journal 2003;0(10):-
		                        		
		                        			
		                        			It is elaborated the relation between CT's commonly seen hitches and regular maintenance, and problems due to periphery assistant devices cannot be ignored. Based on analyses to CT's problems in usual work, 5 factors should be paid attention to maintain CT. Also, 5 points are raised to radiation protection for CT examination.
		                        		
		                        		
		                        		
		                        	
7.Analysis and Treatment of CR Imaging Equipment Common Artifact
Min LI ; Shanxing OU ; Fang YANG
Chinese Medical Equipment Journal 2003;0(10):-
		                        		
		                        			
		                        			A comprehensive overview of CR equipment in the system to use various types of image artifacts and accurate analysis of the reasons for the formation of artifacts; described in detail to avoid and eliminate the artifact method, and measures to solve the work encountered in the actual artifacts of the problem.
		                        		
		                        		
		                        		
		                        	
8.CT Diagnosis of Metastatic Liver Leiomyosarcoma
Hailing LIU ; Yanchan CAI ; Shanxing OU ; Min QIAN ; Weiguang LIN ; Yuanxing GUO
Journal of Practical Radiology 2001;0(06):-
		                        		
		                        			
		                        			Objective To analyze CT characteristics of metastatic liver leiomyosarcoma(MLL),and to improve the diagnostic accuracy of MLL.Methods CT manifestations and clinical characteristics of 5 patients with pathological-proved MLL were retrospectively analyzed.Plain and contrast-enhanced triphase(including arterial,portal phase in all cases and delayed phase in a part of cases) scans were performed.Results On plain scan,all lesions were hypo-dense."Bull-eye-sign" was found in two cases on contrast-enhanced scan,which is the typical metastatic feature.During arterial phase,the smaller lesions showed marked peripheral enhancement and central necrosis.The larger MLL presented as solid-cystic lesions,the parenchyma of tumor was rich in blood supply.Some cases presented mild hypo-dense or iso-dense comparing with the parenchyma of the liver on delayed phase.One case was misdiagnosed as hepatic hemangioma or focal nodular hyperplasia(FNH).Metastases were found out of the liver.Tumor thrombus of portal vein was not found in all of the cases.Conclusion MLL should be considered in the patients with history of extra-hepatic leiomyosarcoma,no marker expressions,no history of hepatitis,no tumor thrombus of portal vein and the special CT findings.
		                        		
		                        		
		                        		
		                        	
9.Construction and evaluation of bone metastasis of breast cancer in nude mice model
Jiangtao WANG ; Jie WANG ; Shanxing OU ; Guoqing QIAO ; Xianguo TANG ; Xiaorong LI ; Junjie CAI
Chinese Journal of General Surgery 2000;0(11):-
		                        		
		                        			
		                        			Objective To establish nude mice model of bone metastasis of breast cancer,and study the best method to evaluate the model.Methods The human breast cancer cell,MDA-MB-231PEGFPN,was injected into left ventricule of nude mice to construct the bone metastasis of breast cancer animal model.Methods of X-ray,whole body optical imaging and pathology were used to evaluate the bone damage after six weeks.Results After six weeks,the result of pathology showed that breast cancer cells had already spread to brain,bone marrow and lung of nude mice.The degree of bone destruction was seen clearly in X-ray,and location of breast cancer cells was observed by whole body optical imaging system.Conclusions The results showed that combined application of X-ray,whole body optical imaging and pathology are the best modalities to evaluate bone metastasis of breast cancer in nude mice.
		                        		
		                        		
		                        		
		                        	
10.CT Diagnosis of Splenic Lesions:An Analysis of 33 Cases
Min QIAN ; Xiaorong LI ; Shanxing OU ; Mingxin LI ; Weiguang LIN
Journal of Practical Radiology 2000;0(12):-
		                        		
		                        			
		                        			Objective To evaluate the value of CT scan in diagnosis of the splenic lesions.Methods A retrospective analysis was made on the CT scans of 33 patients with surgically and pathologically proven splenic lesions,which included plain CT scan(n=33),biphasic contrast-enhanced CT scan(n=28)and contrast delay scanning(n=6).Results In 33 cases,non-neoplastic lesions were 6 cases,including tuberculosis(n=2),hematomas(n=3)and inflammatory pseudotumor associated with a cavernous hemangioma(n=1).Benign tumors were 13 cases,including cysts(n=5),hemangiomas(n=4),lymphanioma(n=1)and lymph-hemangiomas(n=3).Malignant tumors were 14 cases,including malignant lymphoma(n=8),metastases(n=4),malignant myofibroblastoma and hemangioendothelial sarcoma(n=1,respectively).Conclusion CT is of significant value in diagnosis of splenic lesions.
		                        		
		                        		
		                        		
		                        	
            
Result Analysis
Print
Save
E-mail