1.The diagnostic performance of nuchal translucency alone as a screening test for Down syndrome: A systematic review and meta-analysis.
Ma. Sergia Fatima P. SUCALDITO ; John Jefferson V. BESA ; Lia M. PALILEO-VILLANUEVA
Acta Medica Philippina 2025;59(Early Access 2025):1-17
BACKGROUND
Down syndrome or trisomy 21, the most common chromosomal disorder, results from the presence of a third copy of chromosome 21 and manifests as mild to moderate intellectual disability, growth retardation, congenital heart defects, gastrointestinal abnormalities, and characteristic facial features. Several methods have been used to screen for Down syndrome in the prenatal period, such as ultrasound, biomarkers, cell-free DNA testing, and combinations of these tests. A positive result from one or more of these screening tests signals the need for confirmatory karyotyping to clinch the diagnosis. Ultrasound between 11 to 14 weeks of gestation can evaluate nuchal translucency (NT) to screen for Down syndrome. During the second trimester, a triple or quadruple test can also be performed alone or in addition to NT to quantify Down syndrome risk. In limited resource settings however, only the measurement of NT via ultrasound can be performed since biomarker tests are either unavailable or inaccessible. While the diagnostic performance of NT measurement alone has been investigated in several observational studies, there is no consensus on its performance as a sole test to screen for Down syndrome.
OBJECTIVETo determine the diagnostic performance of NT during prenatal first-trimester ultrasound as a screening test for Down syndrome.
METHODSWe performed a systematic search on the PubMed, ProQuest, and Cochrane Library databases for recent systematic reviews and meta-analyses that addressed the objective. The existing reviews found were then independently appraised by the two reviewers with the AMSTAR-2 checklist. To update the existing reviews, a systematic search was done in the same databases to identify additional primary diagnostic studies, which were appraised using the QUADAS-2 tool. Random-effects univariate meta-analysis and summary receiving operator curve (HSROC) analysis for the outcomes were performed using Review Manager version 5.4 and R version 4.2.2, respectively. Subgroup analysis was performed by stratifying the baseline risk of mothers for fetal anomaly as low- or high-risk. Highrisk mothers were defined as women with risk factors such as advanced age, positive serum screen, presence of other ultrasound anomalies, and history of previous fetus with anomaly.
RESULTSWe found 22 cohort studies (n=225,846) of women at low-risk for fetal anomaly. The pooled sensitivity was 67.8% (95% CI: 61.4%-73.6%, I2=70.4%) and specificity was 96.3% (95% CI: 95.5%-96.9%, I2=96.7%). For low-risk women, the overall certainty of evidence was low, due to different modes of verification and heterogeneity not completely explained by variability in baseline risk or cut-points. Seven studies (n=9,197) were on high-risk women. The pooled sensitivity was 62.2% (95% CI: 54.1%-69.7%, I2=38.8%) and specificity was 96.5% (95% CI: 93.6%-98.1%, I2=95.5%). For women at high-risk, the evidence was rated as moderate due to differential verification.
CONCLUSIONOur analysis showed that NT measured through first-trimester ultrasound is specific for Down syndrome but has low sensitivity. Despite this, it is a useful screening test for Down syndrome in low-resource settings where other strategies may not be available or accessible. Furthermore, interpretation of NT results must take into consideration its limited sensitivity as this may lead to missed cases.
Human ; Nuchal Translucency Measurement ; Down Syndrome ; Sensitivity And Specificity
2.Accuracy of baseline low-dose computed tomography lung cancer screening: a systematic review and meta-analysis.
Lanwei GUO ; Yue YU ; Funa YANG ; Wendong GAO ; Yu WANG ; Yao XIAO ; Jia DU ; Jinhui TIAN ; Haiyan YANG
Chinese Medical Journal 2023;136(9):1047-1056
BACKGROUND:
Screening using low-dose computed tomography (LDCT) is a more effective approach and has the potential to detect lung cancer more accurately. We aimed to conduct a meta-analysis to estimate the accuracy of population-based screening studies primarily assessing baseline LDCT screening for lung cancer.
METHODS:
MEDLINE, Excerpta Medica Database, and Web of Science were searched for articles published up to April 10, 2022. According to the inclusion and exclusion criteria, the data of true positives, false-positives, false negatives, and true negatives in the screening test were extracted. Quality Assessment of Diagnostic Accuracy Studies-2 was used to evaluate the quality of the literature. A bivariate random effects model was used to estimate pooled sensitivity and specificity. The area under the curve (AUC) was calculated by using hierarchical summary receiver-operating characteristics analysis. Heterogeneity between studies was measured using the Higgins I2 statistic, and publication bias was evaluated using a Deeks' funnel plot and linear regression test.
RESULTS:
A total of 49 studies with 157,762 individuals were identified for the final qualitative synthesis; most of them were from Europe and America (38 studies), ten were from Asia, and one was from Oceania. The recruitment period was 1992 to 2018, and most of the subjects were 40 to 75 years old. The analysis showed that the AUC of lung cancer screening by LDCT was 0.98 (95% CI: 0.96-0.99), and the overall sensitivity and specificity were 0.97 (95% CI: 0.94-0.98) and 0.87 (95% CI: 0.82-0.91), respectively. The funnel plot and test results showed that there was no significant publication bias among the included studies.
CONCLUSIONS
Baseline LDCT has high sensitivity and specificity as a screening technique for lung cancer. However, long-term follow-up of the whole study population (including those with a negative baseline screening result) should be performed to enhance the accuracy of LDCT screening.
Humans
;
Adult
;
Middle Aged
;
Aged
;
Lung Neoplasms/diagnostic imaging*
;
Early Detection of Cancer
;
Sensitivity and Specificity
;
Mass Screening
;
Tomography, X-Ray Computed
5.Value of High-Frequency Ultrasound in the Diagnosis of Pronator Teres Syndrome.
Min HU ; Shi-Yu CHEN ; Xiao-Long YANG ; Tian-Fang LIN ; Jie-Feng WANG ; Zheng-Hua ZANG
Acta Academiae Medicinae Sinicae 2023;45(3):436-439
Objective To investigate the clinical value of high-frequency ultrasound in the diagnosis of pronator teres syndrome (PTS). Methods The high-frequency ultrasound was employed to examine and measure the median nerve of the pronator teres muscle in 30 patients with PTS and 30 healthy volunteers (control group).The long-axis diameter (LA),short-axis diameter (SA) and cross-sectional area (CSA) of the median nerve were measured.The receiver operating characteristic curve of the median nerve ultrasonic measurement results was established,and the area under the curve (AUC) was calculated.The diagnostic efficiency of each index for PTS was compared with the surgical results as a reference. Results The PTS group showed larger LA[(5.02±0.50) mm vs.(3.89±0.41) mm;t=4.38,P=0.013],SA[(2.55±0.46) mm vs.(1.70±0.41) mm;t=5.19,P=0.009],and CSA[(11.13±3.72) mm2 vs.(6.88±2.68) mm2;t=8.42,P=0.008] of the median nerve than the control group.The AUC of CSA,SA,and LA was 94.3% (95%CI=0.912-0.972,Z=3.586,P=0.001),77.7% (95%CI=0.734-0.815,Z=2.855, P=0.006),and 78.8% (95%CI=0.752-0.821,Z=3.091,P=0.004),respectively.With 8.63 mm2 as the cutoff value,the sensitivity and specificity of CSA in diagnosing PTS were 93.3% and 90.0%,respectively. Conclusion High-frequency ultrasound is a practical method for diagnosing PTS,and the CSA of median nerve has a high diagnostic value.
Humans
;
Forearm/innervation*
;
Muscle, Skeletal/innervation*
;
Median Nerve/diagnostic imaging*
;
Ultrasonography/methods*
;
Sensitivity and Specificity
6.Primary study on recognition of vascular stiffness based on wavelet scattering neural network.
Shuqi REN ; Zengsheng CHEN ; Xiaoyan DENG ; Yubo FAN ; Anqiang SUN
Journal of Biomedical Engineering 2023;40(2):244-248
Cardiovascular disease is the leading cause of death worldwide, accounting for 48.0% of all deaths in Europe and 34.3% in the United States. Studies have shown that arterial stiffness takes precedence over vascular structural changes and is therefore considered to be an independent predictor of many cardiovascular diseases. At the same time, the characteristics of Korotkoff signal is related to vascular compliance. The purpose of this study is to explore the feasibility of detecting vascular stiffness based on the characteristics of Korotkoff signal. First, the Korotkoff signals of normal and stiff vessels were collected and preprocessed. Then the scattering features of Korotkoff signal were extracted by wavelet scattering network. Next, the long short-term memory (LSTM) network was established as a classification model to classify the normal and stiff vessels according to the scattering features. Finally, the performance of the classification model was evaluated by some parameters, such as accuracy, sensitivity, and specificity. In this study, 97 cases of Korotkoff signal were collected, including 47 cases from normal vessels and 50 cases from stiff vessels, which were divided into training set and test set according to the ratio of 8 : 2. The accuracy, sensitivity and specificity of the final classification model was 86.4%, 92.3% and 77.8%, respectively. At present, non-invasive screening method for vascular stiffness is very limited. The results of this study show that the characteristics of Korotkoff signal are affected by vascular compliance, and it is feasible to use the characteristics of Korotkoff signal to detect vascular stiffness. This study might be providing a new idea for non-invasive detection of vascular stiffness.
Humans
;
Vascular Stiffness
;
Neural Networks, Computer
;
Cardiovascular Diseases/diagnosis*
;
Sensitivity and Specificity
7.Comparison of the diagnostic accuracy of CT scan with oral and intravenous contrast versus CT scan with intravenous contrast alone in the diagnosis of blunt abdominal trauma.
Iraj GOLIKHATIR ; Mohammad SAZGAR ; Fatemeh JAHANIAN ; Seyed Jalal MOUSAVI AMIRI ; Hamed AMINIAHIDASHTI
Chinese Journal of Traumatology 2023;26(3):174-177
PURPOSE:
Abdominal CT scan using oral and intravenous (IV) contrast is helpful in the diagnosis of intra-abdominal injuries. However, the use of oral and IV contrast delays the process of diagnosis and increases the risk of aspiration. It has also been shown that CT scan with IV contrast alone is as helpful as CT scan with oral and IV contrast and rectal CT scan in detecting abdominal injuries. Therefore, the present study aims to prospectively compare the diagnostic value of CT scan with oral and IV contrast versus CT scan with IV contrast alone in the diagnosis of blunt abdominal trauma (BAT).
METHODS:
Altogether 123 BAT patients, 60 (48.8%) women and 63 (51.2%) men with the mean age of (40.4 ± 18.7) years who referred to the emergency department of Imam Khomeini Educational and Medical Center in Sari, Iran (a tertiary trauma center in north of Iran) from November 2014 to March 2017 and underwent abdominal CT scans + laparotomy were investigated. Those with penetrating trauma or hemodynamically unstable patients were excluded. The participants were randomly allocated to two groups: abdominal CT scan with oral and IV contrast (n = 63) and CT scan with IV contrast alone (n = 60). No statistically significant difference was found between two groups regarding the hemodynamic parameters, age, gender, injury mechanisms (all p > 0.05). The results of CT scan were compared with that of laparotomy results. The collected data were recorded in SPSS version 22.0 for Windows. Quantitative data were presented as mean and SD.
RESULTS:
The sensitivity and specificity of CT scan using oral and IV contrast in the diagnosis of BAT were estimated at 96.48 (95% CI: 90.73 - 99.92) and 92.67 (95% CI: 89.65 - 94.88), respectively; while CT scan with IV contrast alone achieved a comparable sensitivity and specificity of 96.6 (95% CI: 87.45 - 99,42 and 92.84 (95% CI: 89.88 - 95.00), respectively.
CONCLUSION
CT scan with IV contrast alone can be used to assess visceral injuries in BAT patients with normal hemodynamics to avoid diagnostic delay.
Male
;
Humans
;
Female
;
Young Adult
;
Adult
;
Middle Aged
;
Delayed Diagnosis
;
Tomography, X-Ray Computed
;
Wounds, Nonpenetrating/diagnostic imaging*
;
Abdominal Injuries/diagnostic imaging*
;
Sensitivity and Specificity
;
Retrospective Studies
8.Value of metagenomic next-generation sequencing in children with hematological malignancies complicated with infections.
Chinese Journal of Contemporary Pediatrics 2023;25(7):718-725
OBJECTIVES:
To explore the value of metagenomic next-generation sequencing (mNGS) in the pathogen identification in children with hematological malignancies complicated with infections.
METHODS:
A retrospective analysis was conducted on clinical data and pathogenic test results of 43 children with hematological malignancies who underwent microbial culture and mNGS due to infections in the Third Xiangya Hospital of Central South University between June 2020 and July 2022. Differences in detection rates and characteristics of pathogenic microorganisms detected by mNGS and microbial culture were compared.
RESULTS:
A total of 54 specimens were examined, and the overall detection rate of pathogen by mNGS (80%, 43/54) was significantly higher than that by microbial culture (30%, 16/54) (P<0.001). The most commonly detected infection type by mNGS was viral infection, followed by fungal infection combined viral infection, while that by microbial culture was bacterial infection, followed by fungal infection. The detection rate of fungi by mNGS (33%, 18/54) was higher than that by microbial culture (6%, 3/54) (P<0.001). The detection rate of two or more pathogenic microorganisms by mNGS was higher at 48% compared to microbial culture at 9% (P<0.05). The detection rate of two or more types of pathogenic microorganisms by mNGS was also significantly higher at 33% compared to microbial culture at 2% (P<0.05). The most commonly detected bacteria and fungi by mNGS were Pseudomonas aeruginosa and Candida tropicalis, respectively, in peripheral blood, while Streptococcus pneumoniae and Pneumocystis jirovecii were most commonly detected in bronchoalveolar lavage fluid. Treatment adjustments based on mNGS results were beneficial for 35% (15/43) of the cases.
CONCLUSIONS
mNGS has a higher detection rate than microbial culture and has obvious advantages in diagnosing mixed and fungal infections, making it a useful supplementary diagnostic method to microbial culture.
Humans
;
Child
;
Retrospective Studies
;
Hematologic Neoplasms/complications*
;
High-Throughput Nucleotide Sequencing
;
Bronchoalveolar Lavage Fluid
;
Hospitals
;
Sensitivity and Specificity
9.Expression and Clinical Significance of Serum sFas/sFasL in Patients with Secondary Hemophagocytic Lymphohistiocytosis.
Ling Ling WANG ; Wan Ying CHEN ; Ju Juan WANG ; Guang Li YIN ; Li Min DUAN ; Tian TIAN ; Hong Xia QIU
Journal of Experimental Hematology 2023;31(3):889-895
OBJECTIVE:
To investigate the expression and clinical significance of soluble Fas (sFas) and sFasL in patients with secondary hemophagocytic lymphohistiocytosis (sHLH).
METHODS:
From September 2015 to December 2020, 86 sHLH patients who met the HLH2004 diagnostic criteria were collected. They were divided into 55 cases in the MAHLH group and 31 cases in the NonMAHLH group according to the etiology. Thirty healthy persons were chosen as the normal control group, and 20 patients with systemic lupus erythematosus (SLE) were chosen as the disease control group. The expression levels of sFas and sFasL in the serum of patients with each group were detected by ELISA, and the clinical data were collected for statistical analysis. The significance of sFas and sFasL in sHLH was analyzed by ROC curve.
RESULTS:
Serum levels of sFas and sFasL in patients with newly diagnosed sHLH were significantly higher than those in disease control group and normal control group (P<0.01). The levels of sFas and sFasL in MAHLH group were significantly higher than those in nonMAHLH (infection related HLH and autoimmune disease related HLH) group (P<0.01). The serum levels of sFas and sFasL in 17 newly treated patients with sHLH (17/86) after treatment were significantly lower than those before treatment (P<0.01). The serum sFas level in newly diagnosed sHLH patients was positively correlated with SF(r=0.35), sCD25(r=0.79) and sFasL(r=0.73). The serum sFasL level was positively correlated with SF(r=0.39), sCD25(r=0.64) and sFas(r=0.73). Compared with the NonMAHLH group, the area under the ROC curve was 0.707 (95% CI: 0.593-0.821) (P=0.0015). The optimal critical value for diagnosing MAHLH by sFas level was 12 743 pg/ml, and the sensitivity and specificity were 70.9% and 71% respectively. Compared with the NonMAHLH group, the area under the ROC curve was 0.765(95% CI: 0.659-0.87)(P<0.01). The median OS time of sFas high expression group (≥16798.5 pg/ml) and sFasL high expression group (≥4 785 pg/ml) was significantly shorter than that of the low expression group (P<0.001).
CONCLUSION
Serum levels of sFas and sFasL can be used for the early diagnosis and differential diagnosis of sHLH disease, and are the factor related to the poor prognosis of sHLH.
Humans
;
Lymphohistiocytosis, Hemophagocytic
;
Clinical Relevance
;
ROC Curve
;
Sensitivity and Specificity
;
Lupus Erythematosus, Systemic
10.Validation of MyDiagnostick tool to identify atrial fibrillation in a multi-ethnic Asian population.
Colin YEO ; Aye Aye MON ; Vern Hsen TAN ; Kelvin WONG
Singapore medical journal 2023;64(7):430-433
INTRODUCTION:
MyDiagnostick is an atrial fibrillation (AF) screening tool that has been validated in the Caucasian population in the primary care setting.
METHODS:
In our study, we compared MyDiagnostick with manual pulse check for AF screening in the community setting.
RESULTS:
In our cohort of 671 candidates from a multi-ethnic Asian population, AF prevalence was found to be 1.78%. Of 12 candidates, 6 (50.0%) had a previous history of AF and another 6 (50.0%) were newly diagnosed with AF. Candidates found to have AF during the screening were older (72.0 ± 11.7 years vs. 56.0 ± 13.0 years, P < 0.0001) and had a higher CHADSVASC risk score (2.9 ± 1.5 vs. 1.5 ± 1.1, P = 0.0001). MyDiagnostick had a sensitivity of 100.0% and a specificity of 96.2%. In comparison, manual pulse check had a sensitivity of 83.3% and a specificity of 98.9%.
CONCLUSION
MyDiagnostick is a simple AF screening device that can be reliably used by non-specialist professionals in the community setting. Its sensitivity and specificity are comparable and validated across various studies performed in different population cohorts.
Humans
;
Atrial Fibrillation/diagnosis*
;
Heart Rate
;
Sensitivity and Specificity
;
Risk Factors
;
Electrocardiography
;
Mass Screening


Result Analysis