1.The diagnostic performance of nuchal translucency alone as a screening test for Down syndrome: A systematic review and meta-analysis.
Ma. Sergia Fatima P. SUCALDITO ; John Jefferson V. BESA ; Lia M. PALILEO-VILLANUEVA
Acta Medica Philippina 2025;59(Early Access 2025):1-17
BACKGROUND
Down syndrome or trisomy 21, the most common chromosomal disorder, results from the presence of a third copy of chromosome 21 and manifests as mild to moderate intellectual disability, growth retardation, congenital heart defects, gastrointestinal abnormalities, and characteristic facial features. Several methods have been used to screen for Down syndrome in the prenatal period, such as ultrasound, biomarkers, cell-free DNA testing, and combinations of these tests. A positive result from one or more of these screening tests signals the need for confirmatory karyotyping to clinch the diagnosis. Ultrasound between 11 to 14 weeks of gestation can evaluate nuchal translucency (NT) to screen for Down syndrome. During the second trimester, a triple or quadruple test can also be performed alone or in addition to NT to quantify Down syndrome risk. In limited resource settings however, only the measurement of NT via ultrasound can be performed since biomarker tests are either unavailable or inaccessible. While the diagnostic performance of NT measurement alone has been investigated in several observational studies, there is no consensus on its performance as a sole test to screen for Down syndrome.
OBJECTIVETo determine the diagnostic performance of NT during prenatal first-trimester ultrasound as a screening test for Down syndrome.
METHODSWe performed a systematic search on the PubMed, ProQuest, and Cochrane Library databases for recent systematic reviews and meta-analyses that addressed the objective. The existing reviews found were then independently appraised by the two reviewers with the AMSTAR-2 checklist. To update the existing reviews, a systematic search was done in the same databases to identify additional primary diagnostic studies, which were appraised using the QUADAS-2 tool. Random-effects univariate meta-analysis and summary receiving operator curve (HSROC) analysis for the outcomes were performed using Review Manager version 5.4 and R version 4.2.2, respectively. Subgroup analysis was performed by stratifying the baseline risk of mothers for fetal anomaly as low- or high-risk. Highrisk mothers were defined as women with risk factors such as advanced age, positive serum screen, presence of other ultrasound anomalies, and history of previous fetus with anomaly.
RESULTSWe found 22 cohort studies (n=225,846) of women at low-risk for fetal anomaly. The pooled sensitivity was 67.8% (95% CI: 61.4%-73.6%, I2=70.4%) and specificity was 96.3% (95% CI: 95.5%-96.9%, I2=96.7%). For low-risk women, the overall certainty of evidence was low, due to different modes of verification and heterogeneity not completely explained by variability in baseline risk or cut-points. Seven studies (n=9,197) were on high-risk women. The pooled sensitivity was 62.2% (95% CI: 54.1%-69.7%, I2=38.8%) and specificity was 96.5% (95% CI: 93.6%-98.1%, I2=95.5%). For women at high-risk, the evidence was rated as moderate due to differential verification.
CONCLUSIONOur analysis showed that NT measured through first-trimester ultrasound is specific for Down syndrome but has low sensitivity. Despite this, it is a useful screening test for Down syndrome in low-resource settings where other strategies may not be available or accessible. Furthermore, interpretation of NT results must take into consideration its limited sensitivity as this may lead to missed cases.
Human ; Nuchal Translucency Measurement ; Down Syndrome ; Sensitivity And Specificity
3.Contrast-enhanced ultrasound and contrast-enhanced computed tomography for differentiating mass-forming pancreatitis from pancreatic ductal adenocarcinoma: a meta-analysis.
Jie YANG ; Jiayan HUANG ; Yonggang ZHANG ; Keyu ZENG ; Min LIAO ; Zhenpeng JIANG ; Wuyongga BAO ; Qiang LU
Chinese Medical Journal 2023;136(17):2028-2036
BACKGROUND:
Patients with mass-forming pancreatitis (MFP) or pancreatic ductal adenocarcinoma (PDAC) presented similar clinical symptoms, but required different treatment approaches and had different survival outcomes. This meta-analysis aimed to compare the diagnostic performance of contrast-enhanced ultrasound (CEUS) and contrast-enhanced computed tomography (CECT) in differentiating MFP from PDAC.
METHODS:
A literature search was performed in the PubMed, EMBASE (Ovid), Cochrane Library (CENTRAL), China National Knowledge Infrastructure (CNKI), Weipu (VIP), and WanFang databases to identify original studies published from inception to August 20, 2021. Studies reporting the diagnostic performances of CEUS and CECT for differentiating MFP from PDAC were included. The meta-analysis was performed with Stata 15.0 software. The outcomes included the pooled sensitivity, specificity, positive likelihood ratio (+LR), negative likelihood ratio (-LR), diagnostic odds ratio (DOR), and summary receiver operating characteristic (SROC) curves of CEUS and CECT. Meta-regression was conducted to investigate heterogeneity. Bayesian network meta-analysis was conducted to indirectly compare the overall diagnostic performance.
RESULTS:
Twenty-six studies with 2115 pancreatic masses were included. The pooled sensitivity and specificity of CEUS for MFP were 82% (95% confidence interval [CI], 73%-88%; I2 = 0.00%) and 95% (95% CI, 90%-97%; I2 = 63.44%), respectively; the overall +LR, -LR, and DOR values were 15.12 (95% CI, 7.61-30.01), 0.19 (95% CI, 0.13-0.29), and 78.91 (95% CI, 30.94-201.27), respectively; and the area under the SROC curve (AUC) was 0.90 (95% CI, 0.87-92). However, the overall sensitivity and specificity of CECT were 81% (95% CI, 75-85%; I2 = 66.37%) and 94% (95% CI, 90-96%; I2 = 74.87%); the overall +LR, -LR, and DOR values were 12.91 (95% CI, 7.86-21.20), 0.21 (95% CI, 0.16-0.27), and 62.53 (95% CI, 34.45-113.51), respectively; and, the SROC AUC was 0.92 (95% CI, 0.90-0.94). The overall diagnostic accuracy of CEUS was comparable to that of CECT for the differential diagnosis of MFP and PDAC (relative DOR 1.26, 95% CI [0.42-3.83], P > 0.05).
CONCLUSIONS
CEUS and CECT have comparable diagnostic performance for differentiating MFP from PDAC, and should be considered as mutually complementary diagnostic tools for suspected focal pancreatic lesions.
Humans
;
Contrast Media
;
Bayes Theorem
;
Tomography, X-Ray Computed/methods*
;
Pancreatic Neoplasms/diagnostic imaging*
;
Carcinoma, Pancreatic Ductal/diagnostic imaging*
;
Sensitivity and Specificity
;
Pancreatitis/diagnostic imaging*
;
Ultrasonography/methods*
4.Development and application of a rapid scheme for detection of respiratory virus nucleic acid.
Yuanyuan HUANG ; Yu WANG ; Chengxing ZHOU ; Zhichao ZHOU ; Bingliang ZHOU ; Wenkuan LIU ; Rong ZHOU ; Hong CAO
Chinese Journal of Biotechnology 2023;39(9):3838-3848
This study aimed to develop a portable, accurate and easy-to-operate scheme for rapid detection of respiratory virus nucleic acid. Quantitative real-time polymerase chain reaction (qRT-PCR) was used to verify the effect of extraction-free respiratory virus treatment reagent (RTU) on viral nucleic acid treatment and the effect of ultra-fast fluorescence quantitative PCR instrument (FQ-8A) on nucleic acid amplification, respectively. RTU and FQ-8A were combined to develop a rapid detection scheme for respiratory virus nucleic acid, and the positive detection rate was judged by Ct value using a fluorescence quantitative PCR instrument, and the accuracy of the scheme in clinical samples detection was investigated. The results showed that RTU had comparable sensitivity to the automatic nucleic acid extraction instrument, its extraction efficiency was comparable to the other 3 extraction methods when extracting samples of different virus types, but the extraction time of RTU was less than 5 min. FQ-8A had good consistency in detection respiratory syncytial virus (RSV) and adenovirus (ADV) compared with the control instrument ABI-7500, with kappa coefficients of 0.938 (P < 0.001) and 0.887 (P < 0.001), respectively, but the amplification time was only about 0.5 h. The RTU and FQ-8A combined rapid detection scheme had a highly consistent detection rate with the conventional detection scheme, with a sensitivity of 91.70% and specificity of 100%, and a kappa coefficient was 0.944 (P < 0.001). In conclusion, by combining RTU with FQ-8A, a rapid respiratory virus nucleic acid detection scheme was developed, the whole process could be completed in 35 min. The scheme is accurate and easy-to-operate, and can provide important support for the rapid diagnosis and treatment of respiratory virus.
Humans
;
Respiratory Syncytial Virus Infections/diagnosis*
;
Respiratory Syncytial Virus, Human/genetics*
;
Nucleic Acid Amplification Techniques
;
Real-Time Polymerase Chain Reaction
;
Adenoviridae
;
Sensitivity and Specificity
5.Comparison on Performance of Quantitative Ultrasound and Dual-Energy X-ray Absorptiometry in Evaluating Bone Health of Adults Aged 18-40 Years.
Yu-Xian KUANG ; Hong CHENG ; Yi-Ying ZHENG ; Wei-Ye CHEN ; Zhen-Xin MA ; Gao-Yong ZOU ; Ding ZENG ; Jie MI ; Li LIU
Acta Academiae Medicinae Sinicae 2023;45(5):737-742
Objective To compare the consistency of quantitative ultrasound(QUS)and dual-energy X-ray absorptiometry(DXA)in measuring bone mineral density(BMD)of adults aged 18-40 years in Guangzhou and evaluate the diagnostic value of QUS for identifying low bone mass.Methods DXA was employed to measure the BMD and QUS to measure the speed of sound(SOS)in 731 participants.The Bland-Altman analysis was performed to evaluate the consistency of Z scores between SOS and BMD.With the BMD Z ≤-2.00 as the diagnostic criterion for low bone mass,the receiver operating characteristics curve of QUS was established,and the area under the curve(AUC)and the sensitivity,specificity,and correct diagnostic index for the optimal cut-off of SOS Z score were calculated.Results The results of Bland-Altman analysis showed that the mean differences in the Z scores of SOS and BMD in males and females were 1.27(-0.94 to 3.47)and 0.93(-1.33 to 3.18),respectively.The AUC of SOS Z score in the diagnosis of low bone mass in males and females was 0.734(95%CI=0.380-0.788)and 0.679(95%CI=0.625-0.732),respectively.In males,the optimal cut-off of SOS Z score for low bone mass was -0.35,with the sensitivity,specificity,and correct diagnostic index of 64.1%,68.6%,and 0.327,respectively.In females,the optimal cut-off value of SOS Z scores for low bone mass was -1.14,with the sensitivity,specificity,and correct index of 73.9%,54.8%,and 0.285,respectively.Conclusion QUS and DXA show poor consistency in the diagnosis of BMD in the adults aged 18-40 years in Guangzhou,while QUS demonstrates an acceptable value in identifying low bone mass.
Male
;
Female
;
Adult
;
Humans
;
Absorptiometry, Photon/methods*
;
Bone Density
;
Ultrasonography
;
Bone and Bones
;
ROC Curve
;
Sensitivity and Specificity
6.A study on the application of cross-frequency coupling characteristics of neural oscillation in the diagnosis of mild cognitive impairment.
Xin LI ; Kai WANG ; Jun JING ; Liyong YIN ; Ying ZHANG ; Ping XIE
Journal of Biomedical Engineering 2023;40(5):843-851
In order to fully explore the neural oscillatory coupling characteristics of patients with mild cognitive impairment (MCI), this paper analyzed and compared the strength of the coupling characteristics for 28 MCI patients and 21 normal subjects under six different-frequency combinations. The results showed that the difference in the global phase synchronization index of cross-frequency coupling under δ-θ rhythm combination was statistically significant in the MCI group compared with the normal control group ( P = 0.025, d = 0.398). To further validate this coupling feature, this paper proposed an optimized convolutional neural network model that incorporated a time-frequency data enhancement module and batch normalization layers to prevent overfitting while enhancing the robustness of the model. Based on this optimized model, with the phase locking value matrix of δ-θ rhythm combination as the single input feature, the diagnostic accuracy of MCI patients was (95.49 ± 4.15)%, sensitivity and specificity were (93.71 ± 7.21)% and (97.50 ± 5.34)%, respectively. The results showed that the characteristics of the phase locking value matrix under the combination of δ-θ rhythms can adequately reflect the cognitive status of MCI patients, which is helpful to assist the diagnosis of MCI.
Humans
;
Electroencephalography/methods*
;
Cognitive Dysfunction/diagnosis*
;
Neural Networks, Computer
;
Sensitivity and Specificity
7.Value of contrast-enhanced percutaneous ultrasound in the diagnosis of rotator cuff tear subtype.
Bi-Li LIU ; Yue SHAN ; Qi ZHONG ; Dan GE ; Yan-Ping LI ; Juan LYU ; Shu-Zhi GAN
China Journal of Orthopaedics and Traumatology 2023;36(10):974-981
OBJECTIVE:
To explore characteristics of contrast-enhanced ultrasound (CEUS) images features and diagnostic value of rotator cuff tear subtypes.
METHODS:
From January 2019 to March 2022, percutaneous ultrasound-guided subacromial bursography (PUSB) with persutaneous ultrasound-guide tendon lesionography (PUTL) was performed on 114 patients with suspected rotator cuff injury were evaluated, including 54 males and 60 females ranged in age from 35 to 75 years old with an average of (58.8±8.7 ) years old;76 patients on the right side and 38 patients on the left side;the course of disease ranged from 0.13 to 111 months with an average of (10.2±9.8) months. GE LOGIQ E9 color doppler ultrasound diagnostic high frequency(6 to 12 MHz) was used to CEUS Using arthroscopy as gold standard, receiver operating characteristic (ROC) curve was used to evaluate diagnostic efficacy of US, MRI and CEUS for rotator cuff injury, also sensitivity, specificity, positive predictive value, negative predictive value and accuracy were calculated.
RESULTS:
The sensitivity of US in diagnosing full-thickness tears was 72.1%, specificity was 93.0%, and accuracy was 85.1%. The sensitivity, specificity and accuracy of MRI diagnosis of full-thickness tear were 90.9%, 92.6% and 92.1% respectively. The sensitivity, specificity and accuracy of CEUS in diagnosis of full-thickness tear were 100%. The sensitivity, specificity and accuracy of US in the diagnosis of partial tear were 85.7%, 77.2% and 79.8% respectively. The sensitivity, specificity and accuracy of MRI diagnosis of partial tear were 83.7%, 81.7% and 82.5% respectively. The sensitivity, specificity and accuracy of CEUS in diagnosis of partial tear were 95.7%, 92.6% and 93.9% respectively. There were significant differences in diagnosis results of US, MRI and CEUS for rotator cuff bursa tear (P<0.001). Kapp test showed good consistency between CEUS and arthroscopy in diagnosing rotator cuff tear subtypes (full-thickness and partial tears).
CONCLUSION
Using PUSB/PUTL to observe distribution of contrast media in bursa, tendon and joint cavity to evaluate the type of rotator cuff tear, its diagnostic performance is significantly better than US and MRI. Therefore, percutaneous contrast-enhanced ultrasound can be a reliable method for diagnosing subtypes of rotator cuff tears.
Male
;
Female
;
Humans
;
Infant, Newborn
;
Infant
;
Child, Preschool
;
Child
;
Rotator Cuff Injuries/diagnostic imaging*
;
Rotator Cuff/diagnostic imaging*
;
Sensitivity and Specificity
;
Ultrasonography
;
Magnetic Resonance Imaging/methods*
;
Rupture
;
Arthroscopy
8.Application of metagenomic next-generation sequencing of bronchoalveolar lavage fluid in the diagnosis and treatment of refractory pneumonia in children.
Rong-Guang FENG ; Li-Yan ZHOU ; Rui DOU ; Xue-Yuan ZHOU ; Li-Rong WANG ; Li-Hong HAN ; Yu-Min WANG
Chinese Journal of Contemporary Pediatrics 2023;25(12):1253-1258
OBJECTIVES:
To investigate the clinical application of metagenomic next-generation sequencing (mNGS) of bronchoalveolar lavage fluid (BALF) in the etiological diagnosis and treatment of refractory pneumonia (RTP) in children.
METHODS:
A retrospective analysis was performed on 160 children with RTP who were admitted to the Department of Pediatric Internal Medicine, Maternal and Child Health Hospital of Inner Mongolia Autonomous Region, from January 2020 to March 2023. According to whether mNGS was performed, they were divided into two groups: mNGS (n=80) and traditional testing (n=80). All children received the tests of inflammatory markers and pathogen tests after admission. Traditional pathogenicity tests included microbial culture (sputum specimen collected by suction tube), nucleic acid detection of respiratory pathogens, and serological test (mycoplasma, tuberculosis, and fungi). For the mNGS group, BALF specimens were collected after bronchoscopy and were sent to the laboratory for mNGS and microbial culture. The two groups were analyzed and compared in terms of the detection of pathogens and treatment.
RESULTS:
Compared with the traditional testing group, the mNGS group had a significantly higher detection rate of pathogens (92% vs 58%, P<0.05), with more types of pathogens and a higher diagnostic rate of mixed infections. Compared with the traditional testing group, the mNGS group had a significantly higher treatment response rate and a significantly lower incidence rate of complications during hospitalization (P<0.05). Treatment was adjusted for 68 children in the mNGS group according to the results of mNGS, with a treatment response rate of 96% (65/68) after adjustment.
CONCLUSIONS
Compared with traditional pathogen tests, BALF mNGS can significantly improve the detection rate of pathogens and find some rare pathogens. In clinical practice, when encountering bottlenecks during the diagnosis and treatment of children with RTP, it is advisable to promptly perform the mNGS to identify the pathogens.
Humans
;
Child
;
Bronchoalveolar Lavage Fluid
;
Retrospective Studies
;
Pneumonia/therapy*
;
High-Throughput Nucleotide Sequencing
;
Bronchoscopy
;
Sensitivity and Specificity
9.Value of metagenomic next-generation sequencing in children with hematological malignancies complicated with infections.
Chinese Journal of Contemporary Pediatrics 2023;25(7):718-725
OBJECTIVES:
To explore the value of metagenomic next-generation sequencing (mNGS) in the pathogen identification in children with hematological malignancies complicated with infections.
METHODS:
A retrospective analysis was conducted on clinical data and pathogenic test results of 43 children with hematological malignancies who underwent microbial culture and mNGS due to infections in the Third Xiangya Hospital of Central South University between June 2020 and July 2022. Differences in detection rates and characteristics of pathogenic microorganisms detected by mNGS and microbial culture were compared.
RESULTS:
A total of 54 specimens were examined, and the overall detection rate of pathogen by mNGS (80%, 43/54) was significantly higher than that by microbial culture (30%, 16/54) (P<0.001). The most commonly detected infection type by mNGS was viral infection, followed by fungal infection combined viral infection, while that by microbial culture was bacterial infection, followed by fungal infection. The detection rate of fungi by mNGS (33%, 18/54) was higher than that by microbial culture (6%, 3/54) (P<0.001). The detection rate of two or more pathogenic microorganisms by mNGS was higher at 48% compared to microbial culture at 9% (P<0.05). The detection rate of two or more types of pathogenic microorganisms by mNGS was also significantly higher at 33% compared to microbial culture at 2% (P<0.05). The most commonly detected bacteria and fungi by mNGS were Pseudomonas aeruginosa and Candida tropicalis, respectively, in peripheral blood, while Streptococcus pneumoniae and Pneumocystis jirovecii were most commonly detected in bronchoalveolar lavage fluid. Treatment adjustments based on mNGS results were beneficial for 35% (15/43) of the cases.
CONCLUSIONS
mNGS has a higher detection rate than microbial culture and has obvious advantages in diagnosing mixed and fungal infections, making it a useful supplementary diagnostic method to microbial culture.
Humans
;
Child
;
Retrospective Studies
;
Hematologic Neoplasms/complications*
;
High-Throughput Nucleotide Sequencing
;
Bronchoalveolar Lavage Fluid
;
Hospitals
;
Sensitivity and Specificity
10.Expression and Clinical Significance of Serum sFas/sFasL in Patients with Secondary Hemophagocytic Lymphohistiocytosis.
Ling Ling WANG ; Wan Ying CHEN ; Ju Juan WANG ; Guang Li YIN ; Li Min DUAN ; Tian TIAN ; Hong Xia QIU
Journal of Experimental Hematology 2023;31(3):889-895
OBJECTIVE:
To investigate the expression and clinical significance of soluble Fas (sFas) and sFasL in patients with secondary hemophagocytic lymphohistiocytosis (sHLH).
METHODS:
From September 2015 to December 2020, 86 sHLH patients who met the HLH2004 diagnostic criteria were collected. They were divided into 55 cases in the MAHLH group and 31 cases in the NonMAHLH group according to the etiology. Thirty healthy persons were chosen as the normal control group, and 20 patients with systemic lupus erythematosus (SLE) were chosen as the disease control group. The expression levels of sFas and sFasL in the serum of patients with each group were detected by ELISA, and the clinical data were collected for statistical analysis. The significance of sFas and sFasL in sHLH was analyzed by ROC curve.
RESULTS:
Serum levels of sFas and sFasL in patients with newly diagnosed sHLH were significantly higher than those in disease control group and normal control group (P<0.01). The levels of sFas and sFasL in MAHLH group were significantly higher than those in nonMAHLH (infection related HLH and autoimmune disease related HLH) group (P<0.01). The serum levels of sFas and sFasL in 17 newly treated patients with sHLH (17/86) after treatment were significantly lower than those before treatment (P<0.01). The serum sFas level in newly diagnosed sHLH patients was positively correlated with SF(r=0.35), sCD25(r=0.79) and sFasL(r=0.73). The serum sFasL level was positively correlated with SF(r=0.39), sCD25(r=0.64) and sFas(r=0.73). Compared with the NonMAHLH group, the area under the ROC curve was 0.707 (95% CI: 0.593-0.821) (P=0.0015). The optimal critical value for diagnosing MAHLH by sFas level was 12 743 pg/ml, and the sensitivity and specificity were 70.9% and 71% respectively. Compared with the NonMAHLH group, the area under the ROC curve was 0.765(95% CI: 0.659-0.87)(P<0.01). The median OS time of sFas high expression group (≥16798.5 pg/ml) and sFasL high expression group (≥4 785 pg/ml) was significantly shorter than that of the low expression group (P<0.001).
CONCLUSION
Serum levels of sFas and sFasL can be used for the early diagnosis and differential diagnosis of sHLH disease, and are the factor related to the poor prognosis of sHLH.
Humans
;
Lymphohistiocytosis, Hemophagocytic
;
Clinical Relevance
;
ROC Curve
;
Sensitivity and Specificity
;
Lupus Erythematosus, Systemic


Result Analysis
Print
Save
E-mail