1.Similar Outcomes between Monoblock and Modular Femoral Stems in Total Hip Arthroplasty with Shortening Osteotomy for Dysplastic Hips at Five Years: A Systematic Review with Meta-analysis
Alok RAI ; Sandeep Kumar NEMA ; Arkesh MADEGOWDA ; Dushyant CHOUHAN ; Ankit Kumar GARG
Hip & Pelvis 2025;37(1):1-16
We aimed to examine the outcomes of arthritic congenital dislocation of hip in adults after subtrochanteric shortening derotation osteotomy (SSDO) with cementless hip arthroplasty at a minimum follow-up period of five years. Bibliographic databases were searched and isolated studies were divided into three groups (1, 2, and 3) based on the femoral stem type (modular, monoblock, or mixed). We pooled 931 hips/737 patients from 20 studies. The mean difference in the Harris hip score (HHS) before and after the operation was 47.55 (95% confidence interval [CI] 43.16, 51.94). On subgroup analysis the mean differences of 46.59 (95% CI 41.67, 51.51), 48.24 (95% CI 41.37, 55.11), and 47.30 (95% CI 43.85, 50.75), respectively in HHS were noted in groups 1, 2, and 3. The incidence of uncontrolled proximal femur fractures was comparable at 7.9% and 4.2% in groups 1 and 2; however, it was 0% and 16.6% for controlled fractures. The incidences of nonunion, dislocation, nerve paralysis, heterotopic ossification and revision due to any cause were 0.3%, 6.5%, 1.7%, 2.1%, and 7.9% for group 1 and 1.9%, 4.3%, 1.6%, 5.6%, and 7.4% for group 2. Similar improvements in functional outcome for both monoblock and modular stems can be expected. An increased incidence of controlled proximal femur fractures was observed with use of modular stems. The nonunion at the SSDO site was sporadic.
2.Retraction: Difference of Neck Shortening in Femoral Neck Fracture between Femoral Neck System and Multiple Cannulated Cancellous Screws: Single Center, Prospective Randomized Controlled Trial
Saurabh GUPTA ; Abhay ELHENCE ; Sumit BANERJEE ; Sandeep YADAV ; Prabodh KANTIWAL ; Rajesh Kumar RAJNISH ; Pushpinder KHERA ; Rajesh MALHOTRA
Hip & Pelvis 2025;37(1):85-85
3.Modified Transiliac Plating Technique for Complex Posterior Pelvic Ring Injuries
Abhay ELHENCE ; Sandeep Kumar YADAV ; Jeshwanth NETAJI
Hip & Pelvis 2025;37(1):79-84
Pelvic ring injuries with rotational and translational instability are complex and often result from high-energy trauma, posing significant challenges in management. Internal fixation has emerged as the preferred approach, with traditional methods such as iliosacral screw fixation exhibiting drawbacks like implant-related morbidity and hardware complications. This paper presents a modified minimally invasive transiliac plating technique aimed at addressing these challenges. The surgical technique involves careful preoperative planning, precise patient positioning, and meticulous exposure of the posterior pelvic structures. Key steps include osteotomy of the posterior superior iliac spine (PSIS), formation of a subcutaneous tunnel, contouring and placement of the plate, and fixation with strategically positioned screws. Additionally, the modified technique incorporates the replacement of the osteotomized PSIS bony fragment, providing secondary stability and minimizing the risk of implant back out. This modification aims to enhance biomechanical stability, reduce implant-related morbidity, and ensure optimal functional outcomes. The technique’s efficacy is supported by biomechanical principles and clinical studies, indicating its potential as a promising alternative in the management of unstable pelvic ring injuries. Overall, this modified approach offers improved patient comfort, reduced surgical risks, and enhanced long-term outcomes, contributing to advancements in pelvic ring fracture management.
4.Similar Outcomes between Monoblock and Modular Femoral Stems in Total Hip Arthroplasty with Shortening Osteotomy for Dysplastic Hips at Five Years: A Systematic Review with Meta-analysis
Alok RAI ; Sandeep Kumar NEMA ; Arkesh MADEGOWDA ; Dushyant CHOUHAN ; Ankit Kumar GARG
Hip & Pelvis 2025;37(1):1-16
We aimed to examine the outcomes of arthritic congenital dislocation of hip in adults after subtrochanteric shortening derotation osteotomy (SSDO) with cementless hip arthroplasty at a minimum follow-up period of five years. Bibliographic databases were searched and isolated studies were divided into three groups (1, 2, and 3) based on the femoral stem type (modular, monoblock, or mixed). We pooled 931 hips/737 patients from 20 studies. The mean difference in the Harris hip score (HHS) before and after the operation was 47.55 (95% confidence interval [CI] 43.16, 51.94). On subgroup analysis the mean differences of 46.59 (95% CI 41.67, 51.51), 48.24 (95% CI 41.37, 55.11), and 47.30 (95% CI 43.85, 50.75), respectively in HHS were noted in groups 1, 2, and 3. The incidence of uncontrolled proximal femur fractures was comparable at 7.9% and 4.2% in groups 1 and 2; however, it was 0% and 16.6% for controlled fractures. The incidences of nonunion, dislocation, nerve paralysis, heterotopic ossification and revision due to any cause were 0.3%, 6.5%, 1.7%, 2.1%, and 7.9% for group 1 and 1.9%, 4.3%, 1.6%, 5.6%, and 7.4% for group 2. Similar improvements in functional outcome for both monoblock and modular stems can be expected. An increased incidence of controlled proximal femur fractures was observed with use of modular stems. The nonunion at the SSDO site was sporadic.
5.Retraction: Difference of Neck Shortening in Femoral Neck Fracture between Femoral Neck System and Multiple Cannulated Cancellous Screws: Single Center, Prospective Randomized Controlled Trial
Saurabh GUPTA ; Abhay ELHENCE ; Sumit BANERJEE ; Sandeep YADAV ; Prabodh KANTIWAL ; Rajesh Kumar RAJNISH ; Pushpinder KHERA ; Rajesh MALHOTRA
Hip & Pelvis 2025;37(1):85-85
6.Modified Transiliac Plating Technique for Complex Posterior Pelvic Ring Injuries
Abhay ELHENCE ; Sandeep Kumar YADAV ; Jeshwanth NETAJI
Hip & Pelvis 2025;37(1):79-84
Pelvic ring injuries with rotational and translational instability are complex and often result from high-energy trauma, posing significant challenges in management. Internal fixation has emerged as the preferred approach, with traditional methods such as iliosacral screw fixation exhibiting drawbacks like implant-related morbidity and hardware complications. This paper presents a modified minimally invasive transiliac plating technique aimed at addressing these challenges. The surgical technique involves careful preoperative planning, precise patient positioning, and meticulous exposure of the posterior pelvic structures. Key steps include osteotomy of the posterior superior iliac spine (PSIS), formation of a subcutaneous tunnel, contouring and placement of the plate, and fixation with strategically positioned screws. Additionally, the modified technique incorporates the replacement of the osteotomized PSIS bony fragment, providing secondary stability and minimizing the risk of implant back out. This modification aims to enhance biomechanical stability, reduce implant-related morbidity, and ensure optimal functional outcomes. The technique’s efficacy is supported by biomechanical principles and clinical studies, indicating its potential as a promising alternative in the management of unstable pelvic ring injuries. Overall, this modified approach offers improved patient comfort, reduced surgical risks, and enhanced long-term outcomes, contributing to advancements in pelvic ring fracture management.
7.Similar Outcomes between Monoblock and Modular Femoral Stems in Total Hip Arthroplasty with Shortening Osteotomy for Dysplastic Hips at Five Years: A Systematic Review with Meta-analysis
Alok RAI ; Sandeep Kumar NEMA ; Arkesh MADEGOWDA ; Dushyant CHOUHAN ; Ankit Kumar GARG
Hip & Pelvis 2025;37(1):1-16
We aimed to examine the outcomes of arthritic congenital dislocation of hip in adults after subtrochanteric shortening derotation osteotomy (SSDO) with cementless hip arthroplasty at a minimum follow-up period of five years. Bibliographic databases were searched and isolated studies were divided into three groups (1, 2, and 3) based on the femoral stem type (modular, monoblock, or mixed). We pooled 931 hips/737 patients from 20 studies. The mean difference in the Harris hip score (HHS) before and after the operation was 47.55 (95% confidence interval [CI] 43.16, 51.94). On subgroup analysis the mean differences of 46.59 (95% CI 41.67, 51.51), 48.24 (95% CI 41.37, 55.11), and 47.30 (95% CI 43.85, 50.75), respectively in HHS were noted in groups 1, 2, and 3. The incidence of uncontrolled proximal femur fractures was comparable at 7.9% and 4.2% in groups 1 and 2; however, it was 0% and 16.6% for controlled fractures. The incidences of nonunion, dislocation, nerve paralysis, heterotopic ossification and revision due to any cause were 0.3%, 6.5%, 1.7%, 2.1%, and 7.9% for group 1 and 1.9%, 4.3%, 1.6%, 5.6%, and 7.4% for group 2. Similar improvements in functional outcome for both monoblock and modular stems can be expected. An increased incidence of controlled proximal femur fractures was observed with use of modular stems. The nonunion at the SSDO site was sporadic.
8.Retraction: Difference of Neck Shortening in Femoral Neck Fracture between Femoral Neck System and Multiple Cannulated Cancellous Screws: Single Center, Prospective Randomized Controlled Trial
Saurabh GUPTA ; Abhay ELHENCE ; Sumit BANERJEE ; Sandeep YADAV ; Prabodh KANTIWAL ; Rajesh Kumar RAJNISH ; Pushpinder KHERA ; Rajesh MALHOTRA
Hip & Pelvis 2025;37(1):85-85
9.Modified Transiliac Plating Technique for Complex Posterior Pelvic Ring Injuries
Abhay ELHENCE ; Sandeep Kumar YADAV ; Jeshwanth NETAJI
Hip & Pelvis 2025;37(1):79-84
Pelvic ring injuries with rotational and translational instability are complex and often result from high-energy trauma, posing significant challenges in management. Internal fixation has emerged as the preferred approach, with traditional methods such as iliosacral screw fixation exhibiting drawbacks like implant-related morbidity and hardware complications. This paper presents a modified minimally invasive transiliac plating technique aimed at addressing these challenges. The surgical technique involves careful preoperative planning, precise patient positioning, and meticulous exposure of the posterior pelvic structures. Key steps include osteotomy of the posterior superior iliac spine (PSIS), formation of a subcutaneous tunnel, contouring and placement of the plate, and fixation with strategically positioned screws. Additionally, the modified technique incorporates the replacement of the osteotomized PSIS bony fragment, providing secondary stability and minimizing the risk of implant back out. This modification aims to enhance biomechanical stability, reduce implant-related morbidity, and ensure optimal functional outcomes. The technique’s efficacy is supported by biomechanical principles and clinical studies, indicating its potential as a promising alternative in the management of unstable pelvic ring injuries. Overall, this modified approach offers improved patient comfort, reduced surgical risks, and enhanced long-term outcomes, contributing to advancements in pelvic ring fracture management.
10.Nitrosamines crisis in pharmaceuticals-Insights on toxicological implications,root causes and risk assessment:A systematic review
P.R.Vikram HEMANTH ; Kumar Pramod TEGGINAMATH ; Kumar GUNJAN ; M.Beeraka NARASIMHA ; Deka RAJASHREE ; Suhail Mohammed SHEIK ; Jat SANDEEP ; Bannimath NAMITHA ; Padmanabhan GAYATIRI ; S.Chandan RAVANDUR ; Kumar PRAMOD ; Gurupadayya BANNIMATH
Journal of Pharmaceutical Analysis 2024;14(5):639-652
The presence of N-nitroso compounds,particularly N-nitrosamines,in pharmaceutical products has raised global safety concems due to their significant genotoxic and mutagenic effects.This systematic review investigates their toxicity in active pharmaceutical ingredients(APIs),drug products,and phar-maceutical excipients,along with novel analytical strategies for detection,root cause analysis,refor-mulation strategies,and regulatory guidelines for nitrosamines.This review emphasizes the molecular toxicity of N-nitroso compounds,focusing on genotoxic,mutagenic,carcinogenic,and other physiological effects.Additionally,it addresses the ongoing nitrosamine crisis,the development of nitrosamine-free products,and the importance of sensitive detection methods and precise risk evaluation.This compre-hensive overview will aid molecular biologists,analytical scientists,formulation scientists in research and development sector,and researchers involved in management of nitrosamine-induced toxicity and promoting safer pharmaceutical products.

Result Analysis
Print
Save
E-mail