1.Neuroplasticity Mechanisms of Exercise-induced Brain Protection
Li-Juan HOU ; Lan-Qun MAO ; Wei CHEN ; Ke LI ; Xu-Dong ZHAO ; Yin-Hao WANG ; Zi-Zheng YANG ; Tian-He WEI
Progress in Biochemistry and Biophysics 2025;52(6):1435-1452
Neuroscience is a significant frontier discipline within the natural sciences and has become an important interdisciplinary frontier scientific field. Brain is one of the most complex organs in the human body, and its structural and functional analysis is considered the “ultimate frontier” of human self-awareness and exploration of nature. Driven by the strategic layout of “China Brain Project”, Chinese scientists have conducted systematic research focusing on “understanding the brain, simulating the brain, and protecting the brain”. They have made breakthrough progress in areas such as the principles of brain cognition, mechanisms and interventions for brain diseases, brain-like computation, and applications of brain-machine intelligence technology, aiming to enhance brain health through biomedical technology and improve the quality of human life. Due to limited understanding and comprehension of neuroscience, there are still many important unresolved issues in the field of neuroscience, resulting in a lack of effective measures to prevent and protect brain health. Therefore, in addition to actively developing new generation drugs, exploring non pharmacological treatment strategies with better health benefits and higher safety is particularly important. Epidemiological data shows that, exercise is not only an indispensable part of daily life but also an important non-pharmacological approach for protecting brain health and preventing neurodegenerative diseases, forming an emerging research field known as motor neuroscience. Basic research in motor neuroscience primarily focuses on analyzing the dynamic coding mechanisms of neural circuits involved in motor control, breakthroughs in motor neuroscience research depend on the construction of dynamic monitoring systems across temporal and spatial scales. Therefore, high spatiotemporal resolution detection of movement processes and movement-induced changes in brain structure and neural activity signals is an important technical foundation for conducting motor neuroscience research and has developed a set of tools based on traditional neuroscience methods combined with novel motor behavior decoding technologies, providing an innovative technical platform for motor neuroscience research. The protective effect of exercise in neurodegenerative diseases provides broad application prospects for its clinical translation. Applied research in motor neuroscience centers on deciphering the regulatory networks of neuroprotective molecules mediated by exercise. From the perspectives of exercise promoting neurogenesis and regeneration, enhancing synaptic plasticity, modulating neuronal functional activity, and remodeling the molecular homeostasis of the neuronal microenvironment, it aims to improve cognitive function and reduce the incidence of Parkinson’s disease and Alzheimer’s disease. This has also advanced research into the molecular regulatory networks mediating exercise-induced neuroprotection and facilitated the clinical application and promotion of exercise rehabilitation strategies. Multidimensional analysis of exercise-regulated neural plasticity is the theoretical basis for elucidating the brain-protective mechanisms mediated by exercise and developing intervention strategies for neurological diseases. Thus,real-time analysis of different neural signals during active exercise is needed to study the health effects of exercise throughout the entire life cycle and enhance lifelong sports awareness. Therefore, this article will systematically summarize the innovative technological developments in motor neuroscience research, review the mechanisms of neural plasticity that exercise utilizes to protect the brain, and explore the role of exercise in the prevention and treatment of major neurodegenerative diseases. This aims to provide new ideas for future theoretical innovations and clinical applications in the field of exercise-induced brain protection.
2.Expert Consensus on Clinical Diseases Responding Specifically to Traditional Chinese Medicine: Threatened Abortion
Xinchun YANG ; Shuyu WANG ; Huilan DU ; Songping LUO ; Zhe JIN ; Rong LI ; Xiangyan RUAN ; Qin ZHANG ; Xiaoling FENG ; Shicai CHEN ; Fengjie HE ; Shaobin WEI ; Qun LU ; Yanqin WANG ; Yang LIU ; Qingwei MENG ; Zengping HAO ; Ying LI ; Mei MO ; Xiaoxiao ZHANG ; Ruihua ZHAO
Chinese Journal of Experimental Traditional Medical Formulae 2024;30(7):241-246
Threatened abortion is a common disease of obstetrics and gynecology and one of the diseases responding specifically to traditional Chinese medicine (TCM). The China Association of Chinese Medicine organized experts in TCM obstetrics and gynecology, Western medicine obstetrics and gynecology, and pharmacology to deeply discuss the advantages of TCM and integrated Chinese and Western medicine treatment as well as the medication plans for threatened abortion. After discussion, the experts concluded that chromosome, endocrine, and immune abnormalities were the key factors for the occurrence of threatened abortion, and the Qi and blood disorders in thoroughfare and conception vessels were the core pathogenesis. In the treatment of threatened abortion, TCM has advantages in preventing miscarriages, alleviating clinical symptoms and TCM syndromes, relieving anxiety, regulating reproductive endocrine and immune abnormalities, personalized and diversified treatment, enhancing efficiency and reducing toxicity, and preventing the disease before occurrence. The difficulty in diagnosis and treatment of threatened abortion with traditional Chinese and Western medicine lies in identifying the predictors of abortion caused by maternal factors and the treatment of thrombophilia. Recurrent abortion is the breakthrough point of treatment with integrated traditional Chinese and Western medicine. It is urgent to carry out high-quality evidence-based medicine research in the future to improve the modern diagnosis and treatment of threatened abortion with TCM.
3.Epidemic characteristics and prevalence trends of syphilis in Wuhan in 2010-2021
Wei ZHENG ; Qun ZHOU ; Ping SHI ; Weidong SHI
Journal of Public Health and Preventive Medicine 2024;35(4):115-118
Objective To understand the characteristics and epidemic trend of syphilis in Wuhan from 2010 to 2021, and to provide a reference for the formulation of further prevention and control measures. Methods Data on Wuhan syphilis epidemics from 2010 to 2021 was collected from the China Disease Prevention and Control Information System. The epidemic characteristics and trends of syphilis were analyzed. Results From 2010 to 2021, a total of 36 628 confirmed cases of syphilis were reported in Wuhan, and the reported incidence rate decreased from 29.70/100 000 to 29.62/100 000, with an average annual decrease of 0.33% (P=0.843). Among them, the reported incidence of stage 1 syphilis decreased by 14.37% annually (P<0.001), stage 2 syphilis decreased by 18.59% annually (P<0.001), stage 3 syphilis decreased by 2.02% annually (P=0.523), and fetal syphilis decreased by 22.90% annually (P<0.001), while recessive syphilis increased by 9.19% annually (P<0.001). The ratio of male to female increased from 1.04:1 to 1.36:1 (P<0.001). The proportion of people aged 60 and above increased from 18.44% to 31.17% (P<0.001), and the 35-59 age group had the highest number of reported cases of syphilis in both men and women. Recessive syphilis was most common in men and women aged over 18 years old, and the proportion of recessive syphilis increased with age. Conclusion The prevention and control of syphilis has achieved phased results, especially in mother-to-child interruption and non-recessive syphilis control. On the basis of continuing to consolidate and strengthen the achievements of the current stage, the future syphilis prevention and control work should focus on and respond to the increasing trend of recessive syphilis cases, and take more targeted interventions for people over 60 years old, so as to further curb the spread of syphilis.
4.Construction of blood quality monitoring indicator system in blood banks of Shandong
Qun LIU ; Xuemei LI ; Yuqing WU ; Zhiquan RONG ; Zhongsi YANG ; Zhe SONG ; Shuhong ZHAO ; Lin ZHU ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xiaojuan FAN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):249-257
【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level
5.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
6.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
7.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
8.Analysis of body composition and influencing factors of lean non-alcoholic fatty liver disease in population receiving health examination
Wei ZHAO ; Xiaohua ZHOU ; Wen GUO ; Qun ZHANG
Chinese Journal of Health Management 2024;18(3):185-190
Objective:To analyze the body composition and influencing factors of lean non-alcoholic fatty liver disease in population receiving health examination.Methods:This is a cross-sectional study. Between January 2020 and December 2021, 1 342 individuals who had complete and reliable results of liver transient elastography and body composition testing, with a body mass index (BMI)<24 kg/m 2 and who met the inclusion criteria, were selected from the physical examination population at the Health Management Center of Jiangsu Provincial People′s Hospital. The results of body composition analysis, blood biochemical indexes and liver examination were collected from the subjects for analysis. Method of inter-group comparison: quantitative data that conform to normal distribution were tested using independent sample t-test, while non-conforming data were tested using rank sum test; count data were tested using chi-square test. The binary logistic regression analysis was used to analyze the influencing factors of body composition in lean non-alcoholic fatty liver disease in health examinees. Results:The detection rate of non-alcoholic fatty liver disease was 13.3% in all participants, and it was significantly higher in men than that in women (23.3% (125/537) vs 6.6% (53/805)). The fasting blood glucose (5.15, 5.08 mmol/L), hemoglobin A1c (HbA 1c)(5.5%, 5.6%), triglyceride (TG)(1.70, 1.64 mmol/L), low density lipoprotein cholesterol (LDL-C)(3.37, 3.27 mmol/L), alanine aminotransferase (ALT)(27.0, 21.9 U/L), aspartate aminotransferase (AST)(24.1, 24.0 U/L), gamma-glutamyltransferase (31.4, 21.1 U/L), uric acid (UA)(391, 296 μmol/L), body fat percentage (23.9%, 33.7%), waist-to-hip ratio(0.90, 0.89) and visceral fat area (70.3, 97.0 cm 2) in men and women with lean nonalcoholic fatty liver disease were all higher than those in the population without fatty liver, while the density lipoprotein cholesterol (1.25, 1.32 mmol/L) was lower. Logistic regression analysis showed that BMI, HbA 1c, TG, UA and waist-to-hip ratio were risk factors for lean nonalcoholic fatty liver disease in men, while BMI, HbA 1c, TG, UA and body fat percentage were risk factors for lean nonalcoholic fatty liver disease in women (all P<0.05). Conclusion:BMI, HbA 1c, TG, UA, body fat percentage and waist-to-hip ratio are associated with the development of lean nonalcoholic fatty liver disease.
9.Clinical practice of endoscopic ultrasound-guided liver biopsy among the liver transplant recipients
Wei RAO ; Qian LI ; Jia LIU ; Qiuju TIAN ; Qun ZHANG ; Jinzhen CAI ; Man XIE
Chinese Journal of Digestive Endoscopy 2024;41(2):121-126
Objective:To investigate the application of endoscopic ultrasound-guided liver biopsy (EUS-LB) to liver transplant recipients.Methods:In this retrospective cohort study, a total of 12 liver transplant recipients who underwent EUS-LB by the same endoscopist and specimens were diagnosed and reported by the same pathologist due to abnormal liver function or need to be evaluated for graft fibrosis in the Organ Transplantation Center of the Affiliated Hospital of Qingdao University were enrolled into the EUS-LB group from December 2021 to March 2022, meanwhile, a total of 23 patients whose PLB was completed by the same hepatologist and specimens were diagnosed by the same pathologist during the same period were enrolled in the PLB group. Acquisition of liver specimens and postoperative adverse events of the two groups were compared.Results:Patients in both groups were punctured 1-2 times on average, and the median total length of liver specimens in the EUS-LB group was significantly longer than that in the PLB group (61 mm VS 17 mm, Z=11.362, P=0.002). There was no significant difference in the length of the longest liver specimens between the two groups (17.6±6.9 mm VS 13.7±3.5 mm, t=2.382, P=0.086), while the number of liver specimens in the EUS-LB group was more than that in the PLB group (4.8±2.1 VS 2.3±1.2, t=9.271, P=0.001). The number of complete portal tracts was 11.3±4.6 in the EUS-LB group and 6.2±3.3 in the PLB group ( t=8.457, P=0.003). Abdominal pain was the only postoperative adverse event, and only 1 patient in the EUS-LB group had postoperative abdominal pain, which was fewer than that in the PLB group [8.3% (1/12) VS 43.5% (10/23), χ2=4.893, P=0.036]. Conclusion:Compared with PLB, EUS-LB delivers longer liver biopsy specimens with more complete portal tracts in liver transplant recipients, and fewer recipients complain about postoperative pain in EUS-LB group. Therefore, EUS-LB is a safer, more effective and more comfortable liver biopsy method.
10.Characteristics and distribution of monoclonal gammopathy in clinical patients: a single-center study
Lina ZHU ; Wenqi SHAO ; Jing ZHU ; Ruojian SHEN ; Qun WU ; Baishen PAN ; Beili WANG ; Wei GUO
Chinese Journal of Laboratory Medicine 2024;47(1):72-77
Objective:To investigate the characteristics and distribution of monoclonal gammopathy in clinical patients.Methods:A total of 936 171 patients (508 449 males and 427 722 females) who received capillary zone electrophoresis in Zhongshan Hospital Affiliated to Fudan University from January 2012 to December 2021 were selected, from which 14 945 patients with abnormal bands were screened as the study subjects, including 10 173 males and 4 772 females and the age 21-102 (65±13) years old. According to the age, patients were divided into 8 groups: 21-30 years old (168 cases), 31-40 years old (405 cases), 41-50 years old (1 326 cases), 51-60 years old (3 068 cases), 61-70 years old (4 985 cases), 71-80 years old (3 288 cases), 81-90 years old (1 519 cases), and≥91 years old (186 cases). The diagnostic results of the 14 945 patients with abnormal bands were collected and were divided into tumor group (5 196 cases) and non-tumor disease group (9 749 cases) according to the presence of tumor. The distribution of abnormal bands in different gender, age, and disease groups were retrospectively analyzed. Among the 14 945 patients, 4 988 cases underwent immunofixation electrophoresis, excluding 336 negative cases and 412 cases of double clonal bands reaction, and 4 240 patients with monoclonal immunoglobulin (M protein) reaction were selected as the study subjects, including 2 794 males and 1 446 females aged 21-102 (67±12) years old. They were divided into 8 groups according to the age: 21-30 years old (18 cases), 31-40 years old (91 cases), 41-50 years old (364 cases), 51-60 years old (862 cases), 61-70 years old (1 455 cases), 71-80 years old (904 cases), 81-90 years old (486 cases), and≥91 years old (60 cases). The diagnostic results and immunoglobin subtypes (IgA-κ, IgA-λ, IgG-κ, IgG-λ, IgM-κ, IgM-λ, κ, λ) of patients were collected, and the distribution of monoclonal gammopathy in different gender, age and disease groups were retrospectively analyzed.Results:Among 936 171 patients, 14 945 cases showed abnormal bands in electropherograms with a detection rate of 1.60%; the detection rates of abnormal bands in males and females were 2.00% (10 173/508 449) and 1.12% (4 772/427 722), respectively, with a statistically significant difference ( P<0.01). There was a significant difference in the detection rate of abnormal bands among different age groups ( P<0.01); among them, the highest detection rate of abnormal band in group of ≥91 years old was 5.98%, and the ratio of male to female was 1.67∶1. Among the 14 945 cases of abnormal bands, patients aged 51-60, 61-70 and 71-80 accounted for 20.53% (3 068 cases), 33.36% (4 985 cases) and 22.00% (3 288 cases), respectively, and the differences among the age groups were statistically significant (χ 2=115.82, P<0.01). In the tumor group, the top 3 tumors with abnormal bands were plasmacytoma with 1 123 cases, lymphoma with 289 cases, and leukemia with 49 cases. The detection rate of abnormal bands in electropherograms of plasmacytoma was 89.92% (1 123/1 249), which was higher than that in lymphoma and leukemia [6.73% (289/4 296) and 6.40% (49/766), respectively, P<0.01]. Among 4 240 patients with positive M protein, the proportion of 51-60, 61-70 and 71-80 years old patients were 20.33% (862/4 240), 34.32% (1 455/4 240) and 21.32% (904/4 240), respectively, and the differences among age groups were statistically significant ( P<0.01). The results of M protein types showed that the proportion of IgG-κ type was the highest in both genders, with 32.28% (902/2 794) in males and 34.30% (496/1 446) in females. In the 21-30, 31-40, and 41-50 age groups, the proportion of IgG-λ was the highest, which were 38.89% (7/18), 36.26% (33/91) and 34.07% (124/364) in these groups respectively. However, the proportions of IgG-κ were the highest in either of the 51-60, 61-70, 71-80, 81-90 and ≥91 years old groups, which were 33.87% (292/862), 34.16% (497/1 455), 31.53% (285/904), 34.57% (168/486), 28.33% (17/60), respectively, and the differences among all age groups and gender groups had statistical significance ( P<0.01). Among patients with positive M protein in the tumor group, plasmacytoma accounted for 14.22% (603/4 240), followed by lymphoma 6.30% (267/4 240); among non-tumor diseases, M proteinemia accounted for the highest proportion (7.24%, 307/4 240), followed by pulmonary infection (5.47%, 232/4 240). Conclusions:The detection rate of abnormal bands in capillary zone electrophoresis may increase with age, and is higher in males than in females in the same age group; different malignant tumor diseases can also show abnormal bands in capillary zone electrophoresis, but they are still mainly hematological tumors. Among the positive results of M protein, 61-70 years old group accounts for the highest proportion; the most common type of monoclonal gammopathy is IgG type; in the age group of 21-50 years, the proportion of IgG-λ type is the highest; in the group of >50 years old, the proportion of IgG-κ type is the highest; in the diagnosis of positive monoclonal gammopathy, the top 3 diseases are all hematological diseases, including plasmacytoma, monoclonal gammopathies and lymphoma.


Result Analysis
Print
Save
E-mail