1.Analysis of components migrating to blood and metabolites of Polygonum cuspidatum in rats with acute gouty arthritis
Caiyi KE ; Meng SHEN ; Li JI ; Xuechun WANG ; Yuqing ZHU ; Xi CHEN ; Chengweiqi WANG ; Qun MA
China Pharmacy 2025;36(13):1581-1586
OBJECTIVE To analyze the components migrating to blood and metabolites of Polygonum cuspidatum in rats with acute gouty arthritis (AGA). METHODS SD rats were randomly divided into blank group, model group and P. cuspidatum group (10 g/kg, by raw material), with 6 rats in each group. Except for blank group, AGA model was induced in the remaining groups by injecting potassium oxonate and sodium urate; meanwhile, they were administered corresponding drug solutions or water intragastrically, once a day, for 10 consecutive days. The histopathological morphology of the knee joint tissues in rats was observed;rat serum samples were collected, and the components migrating to blood and metabolites of P. cuspidatum were analyzed by using UPLC-Q-Exactive-Orbitrap-MS. RESULTS Following the intervention with P. cuspidatum, the histopathological morphology of the knee joint synovial tissue in AGA rats showed significant improvement, with reduced inflammatory cell infiltration and hyperplasia, and the preservation of the honeycomb-like structure integrity. In both positive and negative ion modes, a total of 67 chemical components were detected in the serum of rats from P. cuspidatum group, including 25 prototype components and 42 metabolites. The involved compound types encompassed stilbenes, anthraquinones, naphthols, and flavonoids, among others. The metabolic reactions identified included methylation, acetylation, sulfation, and glucuronidation. Notably, compounds such as polydatin, resveratrol and emodin were capable of entering the bloodstream in their prototype forms and undergoing in vivo metabolism. CONCLUSIONS Compounds such as polydatin, resveratrol and emodin are likely to be the active components responsible for the anti-AGA effects of P. cuspidatum.
2.Construction of blood quality monitoring indicator system in blood banks of Shandong
Qun LIU ; Xuemei LI ; Yuqing WU ; Zhiquan RONG ; Zhongsi YANG ; Zhe SONG ; Shuhong ZHAO ; Lin ZHU ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xiaojuan FAN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):249-257
【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level
3.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
4.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
5.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
6.Characteristics and distribution of monoclonal gammopathy in clinical patients: a single-center study
Lina ZHU ; Wenqi SHAO ; Jing ZHU ; Ruojian SHEN ; Qun WU ; Baishen PAN ; Beili WANG ; Wei GUO
Chinese Journal of Laboratory Medicine 2024;47(1):72-77
Objective:To investigate the characteristics and distribution of monoclonal gammopathy in clinical patients.Methods:A total of 936 171 patients (508 449 males and 427 722 females) who received capillary zone electrophoresis in Zhongshan Hospital Affiliated to Fudan University from January 2012 to December 2021 were selected, from which 14 945 patients with abnormal bands were screened as the study subjects, including 10 173 males and 4 772 females and the age 21-102 (65±13) years old. According to the age, patients were divided into 8 groups: 21-30 years old (168 cases), 31-40 years old (405 cases), 41-50 years old (1 326 cases), 51-60 years old (3 068 cases), 61-70 years old (4 985 cases), 71-80 years old (3 288 cases), 81-90 years old (1 519 cases), and≥91 years old (186 cases). The diagnostic results of the 14 945 patients with abnormal bands were collected and were divided into tumor group (5 196 cases) and non-tumor disease group (9 749 cases) according to the presence of tumor. The distribution of abnormal bands in different gender, age, and disease groups were retrospectively analyzed. Among the 14 945 patients, 4 988 cases underwent immunofixation electrophoresis, excluding 336 negative cases and 412 cases of double clonal bands reaction, and 4 240 patients with monoclonal immunoglobulin (M protein) reaction were selected as the study subjects, including 2 794 males and 1 446 females aged 21-102 (67±12) years old. They were divided into 8 groups according to the age: 21-30 years old (18 cases), 31-40 years old (91 cases), 41-50 years old (364 cases), 51-60 years old (862 cases), 61-70 years old (1 455 cases), 71-80 years old (904 cases), 81-90 years old (486 cases), and≥91 years old (60 cases). The diagnostic results and immunoglobin subtypes (IgA-κ, IgA-λ, IgG-κ, IgG-λ, IgM-κ, IgM-λ, κ, λ) of patients were collected, and the distribution of monoclonal gammopathy in different gender, age and disease groups were retrospectively analyzed.Results:Among 936 171 patients, 14 945 cases showed abnormal bands in electropherograms with a detection rate of 1.60%; the detection rates of abnormal bands in males and females were 2.00% (10 173/508 449) and 1.12% (4 772/427 722), respectively, with a statistically significant difference ( P<0.01). There was a significant difference in the detection rate of abnormal bands among different age groups ( P<0.01); among them, the highest detection rate of abnormal band in group of ≥91 years old was 5.98%, and the ratio of male to female was 1.67∶1. Among the 14 945 cases of abnormal bands, patients aged 51-60, 61-70 and 71-80 accounted for 20.53% (3 068 cases), 33.36% (4 985 cases) and 22.00% (3 288 cases), respectively, and the differences among the age groups were statistically significant (χ 2=115.82, P<0.01). In the tumor group, the top 3 tumors with abnormal bands were plasmacytoma with 1 123 cases, lymphoma with 289 cases, and leukemia with 49 cases. The detection rate of abnormal bands in electropherograms of plasmacytoma was 89.92% (1 123/1 249), which was higher than that in lymphoma and leukemia [6.73% (289/4 296) and 6.40% (49/766), respectively, P<0.01]. Among 4 240 patients with positive M protein, the proportion of 51-60, 61-70 and 71-80 years old patients were 20.33% (862/4 240), 34.32% (1 455/4 240) and 21.32% (904/4 240), respectively, and the differences among age groups were statistically significant ( P<0.01). The results of M protein types showed that the proportion of IgG-κ type was the highest in both genders, with 32.28% (902/2 794) in males and 34.30% (496/1 446) in females. In the 21-30, 31-40, and 41-50 age groups, the proportion of IgG-λ was the highest, which were 38.89% (7/18), 36.26% (33/91) and 34.07% (124/364) in these groups respectively. However, the proportions of IgG-κ were the highest in either of the 51-60, 61-70, 71-80, 81-90 and ≥91 years old groups, which were 33.87% (292/862), 34.16% (497/1 455), 31.53% (285/904), 34.57% (168/486), 28.33% (17/60), respectively, and the differences among all age groups and gender groups had statistical significance ( P<0.01). Among patients with positive M protein in the tumor group, plasmacytoma accounted for 14.22% (603/4 240), followed by lymphoma 6.30% (267/4 240); among non-tumor diseases, M proteinemia accounted for the highest proportion (7.24%, 307/4 240), followed by pulmonary infection (5.47%, 232/4 240). Conclusions:The detection rate of abnormal bands in capillary zone electrophoresis may increase with age, and is higher in males than in females in the same age group; different malignant tumor diseases can also show abnormal bands in capillary zone electrophoresis, but they are still mainly hematological tumors. Among the positive results of M protein, 61-70 years old group accounts for the highest proportion; the most common type of monoclonal gammopathy is IgG type; in the age group of 21-50 years, the proportion of IgG-λ type is the highest; in the group of >50 years old, the proportion of IgG-κ type is the highest; in the diagnosis of positive monoclonal gammopathy, the top 3 diseases are all hematological diseases, including plasmacytoma, monoclonal gammopathies and lymphoma.
7.Effect of hand hygiene intervention on healthcare-associated case infection incidence from 2014 to 2022
Jia-Yan DING ; Rui-Hong SHEN ; Wen-Qin ZHOU ; Ya-Yun YUAN ; Mei HUANG ; Ya YANG ; Bing-Chao CAI ; Hai-Qun BAN ; Xiao-Fang FU
Chinese Journal of Infection Control 2024;23(2):208-213
Objective To observe the effect of multi-modal hand hygiene(HH)intervention on HH compliance,as well as the relationship between HH compliance and the healthcare-associated(HA)case infection incidence.Methods From 2014 to 2022,the infection control team in a tertiary first-class hospital implemented multi-modal HH intervention for health care workers(HCWs).The changing trend of HH monitoring data,the correlation be-tween HH compliance rate and HA case infection incidence were analyzed retrospectively.Results The consump-tion of HH products in the wards showed a stable upward trend;HH compliance rate increased from 64.98%in 2014 to 85.01%in 2022(P<0.001),and HA case infection incidence decreased from 1.21%to 0.83%(P<0.05).HH compliance rate was negatively correlated with HA case infection incidence(r=-0.369,P=0.027).HH compliance rates in different regions and job posts in each quarter were increased(P<0.001).For 5 different HH moments in each quarter,HH compliance rate fluctuated slightly before sterile manipulation and after touching patient;presented rising trend after touching surroundings around patient,and decreased before touching patient and after touching patient's body fluid since 2020(P<0.001).Conclusion Multi-modal HH intervention can im-prove the HH compliance of HCWs,improving their HH awareness is conducive to reducing HA case infection incidence.
8.Progress in Epidemiological Research on Relationship Between Duration of Type 2 Diabetes and Risk of Malignant Tumors of Female Reproductive System
Xiaohui ZHOU ; Zhuoying LI ; Wanwan LIU ; Peiwen LU ; Qiuming SHEN ; Qun XU ; Yongbing XIANG
Cancer Research on Prevention and Treatment 2024;51(12):977-988
The relationship between the duration of type 2 diabetes mellitus (T2DM) and the risk of female reproductive malignancies is complex and multifaceted. Large population cohort studies revealed a negative association between the duration of T2DM and the incidence of breast cancer and endometrial cancer. Furthermore, the risk of breast and endometrial cancer is the highest within a short time after T2DM diagnosis and remains remarkably higher in patients with longer diabetes duration than in the nondiabetic population. This phenomenon suggests causal reverse bias and potential detection bias. Nevertheless, T2DM remains an important risk factor for breast and
9.Investigation of coordinated development between blood banks and apheresis plasma collection banks
Qun LIU ; Dunzhu GONGJUE ; Qian ZHANG ; Hui YE ; Hua SHEN ; Mingming QIAO ; Linwei LI ; Xingzhe ZHANG ; Xiangwen CHEN ; Liliang CHEN ; Yang LIU ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(8):927-932
Objective To explore the factors that affect the coordinated development of blood banks and apheresis plas-ma collection banks(hereinafter referred to as plasma banks),and explore feasible measures for the coordinated develop-ment of blood banks and plasma banks.Methods The blood information management system and blood source information management system were used to retrieve related data of blood and plasma donation from 9 cities in Shandong province from 2017 to 2021.The number of blood donors and plasma donors and the intersection of them were analyzed.The data analysis was performed using chi-square test,and a questionnaire survey was conducted to investigate the policies and information status,as well as expectations for coordinated development for blood and plasma donation.Results From 2017 to 2021,the total number of blood donors in 9 cities was higher than that of plasma donors,both have been increasing year by year,and the increase in plasma donors was significantly higher than that of blood donors(131.78%vs 23.90%,P<0.05).The inter-section proportion of blood and plasma donors had increased from 0.45%in 2017 to 1.04%in 2021,with an increase of 131.11%.Among the administrative regions where the participating blood and plasma banks located,94.2%have not re-leased relevant policy to promote the coordinated development of blood and plasma donation.The majority(63%)expected blood banks and plasma banks to be set at a distance more than 50 km apart.The top four functional requirements for the in-terconnection between blood banks and plasma banks management information system were blood test results(94.61%),ID number(87.54%),blood and plasma donation records(85.51%)and health consultation/examination results(82.15%).The top four elements of coordinated development between blood and plasma banks were policy support(96.25%),informa-tion networking(92.36%),top-level design(87.44%)and cultural construction(86.58%).Conclusion The number of donors who donate both blood(mainly whole blood)and plasma has been increasing year by year,which deserves our close attention.To achieve the coordinated development of blood donation and plasma donation,policy support is the most crucial and fundamental means.Establishment of a standard system and the share of blood and plasma donation information is neces-sary for blood informatization construction.It was critical to promote the coordinated development of blood and plasma dona-tion and ensure blood safety with improving legislation,formulating policies for coordinated development,strengthening top-level design,standardizing the publicity of blood and plasma donation and establishing the idea that blood and plasma dona-tion are equally honorable.
10.Long-Term Survival Trend of Gynecological Cancer:A Systematic Review of Population-Based Cancer Registration Data
Zhou XIAOHUI ; Yang DANNI ; Zou YIXIN ; Tang DANDAN ; Chen JUN ; Li ZHUOYING ; Shen QIUMING ; Xu QUN ; Xiang YONGBING
Biomedical and Environmental Sciences 2024;37(8):897-921
Gynecological cancer significantly affect the health of women.This review aimed to describe the global patterns and trends in the survival of patients with gynecological cancers.We searched PubMed,Embase,Web of Science,SinoMed,and SEER for survival analyses of cancer registration data of cervical,endometrial,and ovarian cancers published between 1980 and 2022.Globally,the highest 5-year observed survival rate for cervical cancer was 76.5%in Anshan,Liaoning,China(2008-2017).The 5-year observed survival rates of endometrial and ovarian cancers were higher in Finland(1995-1999,82.5%)and Singapore(1988-1992,62.0%).The 5-year relative survival rate of cervical cancer patients was higher in Haining,Zhejiang,China(2011-2014,85.8%).Korea ranked first at 89.0%and 64.5%for endometrial and ovarian cancers,respectively.Survival rates have improved for cervical,endometrial,and ovarian cancers.Patients aged≥75 years and those with advanced-stage disease had the worst 5-year survival rates.Survival rates were better for squamous cell carcinoma in cervical cancer,for endometrial carcinoma and mucinous adenocarcinoma in endometrial cancer,and for germ cell and sex-cord stromal tumors in ovarian cancer.Over the past four decades,the survival rates of gynecological cancers have increased globally,with notable increases in cervical and endometrial cancers.Survival rates are higher in developed countries,with a slow-growing trend.Future studies should focus on improving survival,especially in ovarian cancer patients.

Result Analysis
Print
Save
E-mail