1.Analysis of the frequency of X-ray diagnostic examinations and CT radiation doses in public hospitals of a district in Ningbo City, China
Shuxia HAO ; Mengxue LI ; Yong WANG ; Shengnan FAN ; Jingguo ZHANG ; Xueying WANG ; Jun DENG ; Quanfu SUN
Chinese Journal of Radiological Health 2025;34(3):324-330
Objective To systematically analyze the medical radiation exposure levels in a district of Ningbo City and to provide a scientific basis for the reasonable and effective control of medical radiation exposure. Methods Based on the radiological diagnosis frequency and dose information system, basic medical radiation exposure data were collected, such as radiation doses received by patients in various X-ray diagnostic examinations, from all 13 public medical institutions in a district of Ningbo City from January 1 to December 31, 2020. The data were analyzed for the percentage and collective effective dose of various diagnostic examinations, the distribution of examinations by sex and age, and the number of patients undergoing two or more examinations and their cumulative doses within multiple time intervals. Results Among medical X-ray diagnostic examinations in the district, the percentages of CT examination and routine photography examination were 50.88% and 47.93%, respectively, and the collective effective dose of CT examination accounted for 97.75%. By age and sex, the frequency of examination was the highest in the age group of 45-54 years, and the frequency of examination in the male was higher than that in the female before age 55. The annual effective dose for two patients exceeded 100 mSv. Conclusion In this study, CT examination accounted for up to 50.88% of all medical X-ray diagnostic examinations, and contributed 97.75% of the collective effective dose, highlighting the need for particular attention to the justification of medical radiation exposure from CT.
2.Analysis of the eye lens dose and annual effective dose to some interventional radiation workers in Xinxiang city
Yuxuan MAO ; Bingjie ZHANG ; Yulong LIU ; Xuan WANG ; Tongzhen LIU ; Tianhe JIA ; Fengling ZHAO ; Quanfu SUN ; Dianhui WANG
Chinese Journal of Radiological Medicine and Protection 2024;44(3):216-222
Objective:To analyze the eye lens dose and annual effective dose to interventional radiation workers in some hospitals of Xinxiang city from 2020 to 2022, and to ascertain the dose to interventional radiation workers.Methods:By using TLDs, the eye lens dose Hp(3) and annual effective dose Hp(10) were monitored for three consecutive years in six hospitals in Xinxiang city. The lens doses and annual effective doses to intervention radiation workers in different years in different-level hospitals and departments were analyzed. Results:From 2020 to 2022, a total of 117 people were monitored. The left eye lens dose range was 0.12-164.24 mSv, and the right eye lens dose range was 0.07-51.64 mSv. The average annual dose was 8.56 mSv for left eye lens and 4.49 mSv for right eye lens The average annual dose distribution in the MDL-5 mSv range for the left and right eye lens was 60.68% and 73.50%, respectively. 9.41% (11 people) of the left eye lens doses exceeded 20 mSv. The annual effective doses range was 0.11-31.27 mSv, with average annual dose of 2.56 mSv. The proportion of average annual effective doses mainly distributed in the range of MDL to 1.25 mSv was 52.14%, with 2.56% annual effective dose exceeding 20 mSv. There was no significant difference in left and right eye lens dose and annual effective dose between the tertiary hospitals and the secondary hospitals in three years ( P>0.05). Compared with different departments, the cumulative per capita dose in three years was statistically significant (left eye H=11.42, right eye H=13.72, annual effective dose H=25.94, P<0.05). The lens dose and annual effective dose in neurology department were lower than those in cardiology department and comprehensive intervention department ( Zcardiology department=-3.33, -3.78, -4.83, P<0.05; Zcomprehensive intervention department=-2.71, -2.63, -4.39, P<0.05). Conclusions:Most of the annual equivalent dose and annual effective dose to eye lens of the interventional radiation workers in Xinxiang city meet the national limits, but some of them have higher doses and exceed the national limits. It is suggested that the routine and continuous monitoring of eye lens doses to interventional radiologists should be strengthened while routine monitoring of annual effective dose, and attention should be paid to the eye lens and annual effective dose to interventional radiologists in secondary hospitals to improve the awareness of protection.
3.Perinatal management and challenges of systemic autoimmune diseases
Youmei CHEN ; Jianxin ZHEN ; Chenhong WANG ; Quanfu ZHANG
Journal of Chinese Physician 2024;26(11):1601-1606
Pregnancy with autoimmune diseases is a challenging area that involves multidisciplinary management of immunology, rheumatology, and obstetrics. During pregnancy, the maternal immune system dynamically regulates the balance between maintaining immune tolerance to the fetus and autoimmune. However, for women with common systemic autoimmune diseases such as systemic lupus erythematosus, antiphospholipid syndrome, and rheumatoid arthritis, this balance can be upset, leading to exacerbation or recurrence of the disease and significantly increasing the risk of pregnancy complications. This paper describes the adaptive changes of the immune system during pregnancy and the effects of systemic autoimmune diseases on pregnancy outcomes, proposes multidisciplinary management strategies and challenges in perinatal pregnancy, and aims to provide references for optimizing clinical practice and improving pregnancy outcomes.
4.Analysis of issues in quality control test results of linear accelerators in China
Hongbo WANG ; Xuexia LIU ; Songhui ZHANG ; Chenxu HUANG ; Yuexin GUO ; Quanfu SUN
Chinese Journal of Radiological Health 2024;33(6):675-680
Objective To study the unqualified items in the reported quality control tests of linear accelerators, analyze the issues in quality control tests, and propose the key points and development directions for accelerator quality control test in China. Methods A literature review was conducted using the CNKI database to analyze the qualified rates of test items and the issues in quality control tests. Results In the literature on the quality control tests of linear accelerators, except for a few provinces where the qualified rates of all test items were 100%, unqualified items were reported in most of the literature. There were unqualified items related to X-ray and electron beam in different reports. Error of dose indication was the unqualified item with the highest occurrence rate in X-ray test, and the item with the lowest qualified rates in X-ray and electron beam tests. The lowest qualified rate of X-ray dose indication error was 73.5% in 2016, and the lowest qualified rate of electron beam dose indication error was 46.2% in 2017. Conclusion Tests should be carried out strictly according to the items and intervals specified by the quality control test standards. Hospitals, radiation health technology service institutions, and health administrative departments should each fulfill their respective responsibilities, work together, and place emphasis on ensuring effective quality control tests of linear accelerators to further enhance the overall quality control standards for these devices.
5.Analysis and application of occupationally exposed dose estimation programs for aircrews
Yu ZHANG ; Shengnan FAN ; Yu ZHAO ; Mengxue LI ; Jun DENG ; Quanfu SUN
Chinese Journal of Radiological Medicine and Protection 2024;44(6):504-510
Objective:To estimate and analyze the levels of occupational exposure of aircrews in China, and to provide scientific basis for strengthening occupational health management.Methods:Through the FlightAware website, the flight data were collected of a total of 104 routes flying between airports with large passenger volume in China. Four kinds of cosmic radiation dose estimation programs CARI, SIEVERT, PCAIRE, and JISCARD-EX were compared and analyzed from the aspects of covering the number of airports in China, program user experience and example calculation of airline effective dose. Based on route logs, CARI-7A was applied to estimate the levels of occupational exposure of Chinese aircrews to cosmic radiation.Results:The difference in the effective doses calculated by use of these four cosmic radiation dose estimation programs for the routes with different solar activity levels was statistically significant ( M=7.52-180.98, P<0.05). The annual effective dose estimated by PCAIRE for 68 routes from 2014 to 2021 was significantly higher than that estimated by CARI-7A ( Z=2.52, P<0.05). Based on CARI-7A, the annual effective doses from cosmic radiation to aircrews in China from 2014 to 2021 were estimated, being 1.26 (0.57-2.35) mSv for flight attendants and 1.03 (0.47-1.92) mSv for pilots. The effective dose from cosmic radiation to aircrews on a single flight on some high-frequency routes in China ranged from 0.57 to 6.88 μSv. Conclusions:The level of occupational exposure of Chinese aircrews to cosmic radiation meets the requirements of national standards, but is higher than that of occupational exposure from medical and industrial applications of radiation, so it is still necessary to further strengthen the mamagememt of occupational exposure and occupational health of aircrews.
6.Implementation and revision of the Measures for the Management of Radiation Workers’ Occupational Health
Shiyue CUI ; Yinping SU ; Fengling ZHAO ; Zhiwei XING ; Li LIANG ; Juan YAN ; Yuanyuan ZHANG ; Bo WANG ; Jianxiang LIU ; Changsong HOU ; Erdong CHEN ; Jun DENG ; Quanfu SUN
Chinese Journal of Radiological Health 2023;32(3):335-340
Since the implementation of the Measures for the Management of Radiation Workers’ Occupational Health in November 2007, it has played an extremely important role in protecting the occupational health of radiation workers. There are more than 700 000 radiation workers in about 100 000 workplaces with potential radiation exposure, as well as a large number of miners exposed to high levels of radon. As the radiation health monitoring project suggests, measures of occupational health management such as personal dose monitoring and occupational health examination of radiation workers have been widely implemented and achieved good results in the protection of radiation workers. However, the risks of chromosomal aberration and specific turbidity of the eye lens of radiation workers have increased in high-risk positions such as interventional radiology, nuclear medicine, and industrial flaw detection. The control of high radon exposure in miners needs to be strengthened. It is necessary to adapt to the new situation in view of new challenges and actively promote the revision of the Measures for the Management of Radiation Workers’ Occupational Health, so as to further improve the occupational health management of radiation workers in China.
8.Establishment and operation of international English journal in special medicine
Lin ZHANG ; Xianhua GUO ; Chen LI ; Qing ZHANG ; Quanfu SUN
Chinese Journal of Radiological Health 2023;32(5):495-498
In response to the national strategy of building first-class journals and filling the gaps in English journals on radiation medicine and protection, the Radiation Medicine and Protection (RMP) was founded. Within three years, it has entered domestic and international databases such as DOAJ, Scopus, CSCD, WJCI and Embase with its CiteScore ranking first in the discipline and WJCI index surpassing a variety of international authoritative radiation protection journals. Collaborating with KeAi and Elsevier successively, this open access publisher has gained a significant number of international citations to achieve international visibility. Owing to the influence of disciplinary characteristics, domestic evaluation systems, and international exchange situation, RMP is facing development bottlenecks. We hope to explore breakthrough measures from the aspects of expanding manuscript sources, strengthening academic exchanges, and attracting young experts to joining the editorial board.
9.Investigation on awareness of radon and health risks in non-uranium miners from 2020 to 2021
Pinhua ZHANG ; Xiaoliang LI ; Yinping SU ; Quanfu SUN ; Jianxiang LIU
Chinese Journal of Radiological Medicine and Protection 2023;43(1):51-55
Objective:To understand the non-uranium miners′ awareness of radon and health risks in China and analyze the relevant influencing factors, in order to provide research basis for radiological protection institutions and employers to carry out radon health education.Methods:Male miners in 32 typical non-uranium mines from 11 provinces were selected by using cluster random sampling method from June 2020 to December 2021. The awareness of radon and health risks was investigated, and the influencing factors were analyzed by binary logistic regression model.Results:A total of 1 184 non-uranium miners were investigated, and the radon awareness rate of them was 19.17%. 36.56% of the non-uranium miners heard about radon knew the radon health risks accurately, and 18.06% could identify the measures to reduce radon concentration correctly. Univariate analysis showed that the radon awareness rate of non-uranium miners varied with different education levels, labor relations, post categories, and regions ( χ2=55.92, 21.89, 64.31, 11.26, P<0.05 ). The result of logistic regression analysis showed that a bachelor degree or above, regular employee, administrative personnel and technical personnel were influencing factors of the radon awareness level ( χ2=12.81, 6.58, 5.66, 21.44, P<0.05 ). There was no statistically significant difference of radon awareness rate in different ages, working years, regions, and smoke groups ( P>0.05 ). Conclusions:The awareness level of radon and health risks of non-uranium miners was relatively low in China. Radiological protection institutions and employers should strengthen education and training of radon related knowledge in non-uranium miners through mass media, on-duty training, contract notification and workplace publicity board notification, so as to improve their personal protection consciousness.
10.The necessity and countermeasures of strengthening radiation dose management in diagnostic radiology
Yantao NIU ; Yongxian ZHANG ; Weihai ZHUO ; Jun DENG ; Hui XU ; Quanfu SUN
Chinese Journal of Radiological Medicine and Protection 2023;43(4):241-247
In recent years, the diagnostic radiology, especially CT scanning, has a rapidly increased frequency in our country, becoming the largest artificial radiation source to the average individual doses to the population. In clinical diagnosis and treatment activities, the examined patients and individuals may undergo multiple procedures and multiple frequencies of medical imaging in a short period of time and receive high cumulative radiation doses even exceeding 50 or 100 mSv in a single day, posing a potential risk to their health. Therefore, it is necessary to carry out statistical analysis and management of diagnostic radiation dose information to minimize the probability of excessive dose and associated radiation risk. In this paper, the international cognition of radiation risks in diagnostic radiology, diagnostic equipment and medical imaging frequency, radiation dose and its management status are described. Four countermeasures for radiation dose management are put forward to provide reference for further improving radiation protection in clinical practice.

Result Analysis
Print
Save
E-mail