1.Design of automatic urine volume detection and collection device
Yan CHEN ; De-Zhao ZHAI ; Xiao-Quan ZHANG ; Fu-Long LIU ; Xiao-Tao ZHANG ; Yong-Mei ZHANG ; Wei CEHN ; Fang ZHANG ; Guo-Hui WU ; Jun DENG ; Dan LI
Chinese Medical Equipment Journal 2024;45(4):66-69
Objective To develop an automatic urine volume detection and collection device to solve the problems of routine urine test.Methods An automatic urine volume detection and collection device was developed with the components of a main control system,a detection system,a prompting system and a grasping and moving system.The main control system consisted of two STM32 microcontrollers and a reset switch;the detection system was made up of a weighing module,an infrared module and indicator lights,which had its urine volume automatic detection algorithm developed based on the Keil5 platform;the prompting system realized voice broadcasting through the voice module fixed on the back panel of the box;the grasping and moving system was composed of a rail drive motor(86CM stepper motor),a photoelectric switch and a motorized gripper.Results The device developed tested urine samples with an accuracy of 99.44%,and could collect qualified samples automatically and quickly.Conclusion The device developed detects urine volume and collects samples automatically,and enhances the accuracy and efficiency of urine examination.[Chinese Medical Equipment Journal,2024,45(4):66-69]
2.Percutaneous balloon mitral valvuloplasty guided by intracardiac echocardiography:a report of two cases
De-Jian LI ; Song CHEN ; Chao XU ; Xue JIANG ; Bo WANG ; Jian-Fei FENG ; Dong-Bang SONG ; Guo-Hui ZHANG ; Ming-Quan WANG ; Wei-Min WANG ; Da-Dong ZHANG
Chinese Journal of Interventional Cardiology 2024;32(5):295-297
For the past 30 years,percutaneous balloon mitral valve dilatation has been performed under the guidance of X-rays and bedside ultrasound.However,there are still some cases of mitral valve stenosis in the large atrium where balloon dilation failed.Intraperitoneal ultrasound-guided percutaneous balloon mitral valve plasty is accurate and feasible,which can reduce the occurrence of complications and improve the success rate of such elderly complex cases.Two patients with severe mitral stenosis underwent percutaneous balloon mitral valve plasty guided by intracardiac ultrasound.The operations were successful without any complications,which can provide reference for clinical treatment of mitral stenosis.
3.Diagnostic value of vena contracta area measurement for grading tricuspid regurgitation severity under different etiologies:a three-dimensional echocardiography study
Bei-Qi CHEN ; Yu LIU ; Wu-Xu ZUO ; Quan LI ; Yuan-Feng WU ; De-Hong KONG ; Cui-Zhen PAN ; Li-Li DONG ; Xian-Hong SHU
Fudan University Journal of Medical Sciences 2024;51(4):484-493,504
Objective To explore the cut-off value of three dimensional(3D)vena contracta area(VCA)in diagnosing severe tricuspid regrugitation(TR)under different etiologies and its accuracy and practicality in clinical application.Methods From Mar 2019 to May 2021,ninety-two patients with confirmed TR underwent two dimensional(2D)and 3D transthoracic echocardiography.The correlation and consistency between 3D VCA 3D calculated based on the proximal isokinetic surface area(PISA)effective regurgitant orifice area(EROA)was calculated.Comprehensive 2D multi-parameter method was used as a reference method to calculate the cut-off value of the diagnosis of severe TR.Results A total of 85 patients were ultimately included.3D VCA and 3D PISA EROA had similar and acceptable correlations in both primary TR and secondary TR(primary TR:r=0.831,P<0.01;secondary TR:r=0.806,P<0.01).Bland-Altman analysis showed that 3D VCA overestimated TR compared with 3D PISA EROA(62%overestimated in the total patient population,51%overestimated in primary TR,and 74%overestimated in secondary TR).In secondary TR,the cut-off value of 3D VCA for diagnosing severe TR was 0.45 cm2(sensitivity 89%,specificity 82%);combining clinical symptoms,positive 2D PISA EROA results and 3D VCA results for severe TR,the chi-square value was higher than those only included clinical symptoms or incorporated clinical symptoms and positive 2D PISA EROA results(42.168 vs.26.059 and 16.759,P<0.01).Conclusion 3D VCA would overestimate TR,and had high and incremental diagnostic value for evaluating severe TR in secondary TR.
4.HbA1c comparison and diagnostic efficacy analysis of multi center different glycosylated hemoglobin detection systems.
Ping LI ; Ying WU ; Yan XIE ; Feng CHEN ; Shao qiang CHEN ; Yun Hao LI ; Qing Qing LU ; Jing LI ; Yong Wei LI ; Dong Xu PEI ; Ya Jun CHEN ; Hui CHEN ; Yan LI ; Wei WANG ; Hai WANG ; He Tao YU ; Zhu BA ; De CHENG ; Le Ping NING ; Chang Liang LUO ; Xiao Song QIN ; Jin ZHANG ; Ning WU ; Hui Jun XIE ; Jina Hua PAN ; Jian SHUI ; Jian WANG ; Jun Ping YANG ; Xing Hui LIU ; Feng Xia XU ; Lei YANG ; Li Yi HU ; Qun ZHANG ; Biao LI ; Qing Lin LIU ; Man ZHANG ; Shou Jun SHEN ; Min Min JIANG ; Yong WU ; Jin Wei HU ; Shuang Quan LIU ; Da Yong GU ; Xiao Bing XIE
Chinese Journal of Preventive Medicine 2023;57(7):1047-1058
Objective: Compare and analyze the results of the domestic Lanyi AH600 glycated hemoglobin analyzer and other different detection systems to understand the comparability of the detection results of different detectors, and establish the best cut point of Lanyi AH600 determination of haemoglobin A1c (HbA1c) in the diagnosis of diabetes. Methods: Multi center cohort study was adopted. The clinical laboratory departments of 18 medical institutions independently collected test samples from their respective hospitals from March to April 2022, and independently completed comparative analysis of the evaluated instrument (Lanyi AH600) and the reference instrument HbA1c. The reference instruments include four different brands of glycosylated hemoglobin meters, including Arkray, Bio-Rad, DOSOH, and Huizhong. Scatter plot was used to calculate the correlation between the results of different detection systems, and the regression equation was calculated. The consistency analysis between the results of different detection systems was evaluated by Bland Altman method. Consistency judgment principles: (1) When the 95% limits of agreement (95% LoA) of the measurement difference was within 0.4% HbA1c and the measurement score was≥80 points, the comparison consistency was good; (2) When the measurement difference of 95% LoA exceeded 0.4% HbA1c, and the measurement score was≥80 points, the comparison consistency was relatively good; (3) The measurement score was less than 80 points, the comparison consistency was poor. The difference between the results of different detection systems was tested by paired sample T test or Wilcoxon paired sign rank sum test; The best cut-off point of diabetes was analyzed by receiver operating characteristic curve (ROC). Results: The correlation coefficient R2 of results between Lanyi AH600 and the reference instrument in 16 hospitals is≥0.99; The Bland Altman consistency analysis showed that the difference of 95% LoA in Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180) was -0.486%-0.325%, and the measurement score was 94.6 points (473/500); The difference of 95% LoA in the Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant II) was -0.727%-0.612%, and the measurement score was 89.8 points; The difference of 95% LoA in the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT) was -0.231%-0.461%, and the measurement score was 96.6 points; The difference of 95% LoA in the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT) was -0.469%-0.479%, and the measurement score was 91.9 points. The other 14 hospitals, Lanyi AH600, were compared with 4 reference instrument brands, the difference of 95% LoA was less than 0.4% HbA1c, and the scores were all greater than 95 points. The results of paired sample T test or Wilcoxon paired sign rank sum test showed that there was no statistically significant difference between Lanyi AH600 and the reference instrument Arkray HA8180 (Z=1.665,P=0.096), with no statistical difference. The mean difference between the measured values of the two instruments was 0.004%. The comparison data of Lanyi AH600 and the reference instrument of all other institutions had significant differences (all P<0.001), however, it was necessary to consider whether it was within the clinical acceptable range in combination with the results of the Bland-Altman consistency analysis. The ROC curve of HbA1c detected by Lanyi AH600 in 985 patients with diabetes and 3 423 patients with non-diabetes was analyzed, the area under curve (AUC) was 0.877, the standard error was 0.007, and the 95% confidence interval 95%CI was (0.864, 0.891), which was statistically significant (P<0.001). The maximum value of Youden index was 0.634, and the corresponding HbA1c cut point was 6.235%. The sensitivity and specificity of diabetes diagnosis were 76.2% and 87.2%, respectively. Conclusion: Among the hospitals and instruments currently included in this study, among these four hospitals included Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180), Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant Ⅱ), the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT), and the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT), the comparison between Lanyi AH600 and the reference instruments showed relatively good consistency, while the other 14 hospitals involved four different brands of reference instruments: Arkray, Bio-Rad, DOSOH, and Huizhong, Lanyi AH600 had good consistency with its comparison. The best cut point of the domestic Lanyi AH600 for detecting HbA1c in the diagnosis of diabetes is 6.235%.
Pregnancy
;
Child
;
Humans
;
Female
;
Glycated Hemoglobin
;
Cohort Studies
;
Diabetes Mellitus/diagnosis*
;
Sensitivity and Specificity
;
ROC Curve
5.Interpretation of the World Society of Emergency Surgery Guidelines for Diagnosis and Treatment of Acute Left Colonic Diverticulitis in the Elderly (2022 edition).
Chinese Journal of Surgery 2023;61(1):29-32
Acute colonic diverticulitis is one of the most common clinical conditions encountered by surgeons in the acute setting. Acute left colonic diverticulitis in the elderly presents with unique epidemiological features when compared with younger patients. Elderly patients have a lower risk of recurrent episodes, higher in-hospital and postoperative mortality. An international multidisciplinary panel of experts from the World Society of Emergency Surgery (WSES) formulated the guidelines for diagnosis and treatment of acute left colonic diverticulitis in the elderly (2022 edition). This article aims to interpret the guidelines statements on the following topics: diagnosis, management, non-surgical therapy and surgical technique.
Humans
;
Aged
;
Diverticulitis, Colonic/surgery*
;
Surgeons
6.Clinical efficacy and safety of venetoclax combined with multidrug chemotherapy in the treatment of 15 patients with relapsed or refractory early T-cell precursor acute lymphoblastic leukemia.
Jin Yu KONG ; Li Hong ZONG ; Yan PU ; Yin LIU ; Xin KONG ; Meng Yun LI ; Jian ZHANG ; Bao Quan SONG ; Sheng Li XUE ; Xiao Wen TANG ; Hui Ying QIU ; De Pei WU
Chinese Journal of Hematology 2023;44(8):649-653
Objective: To explore the efficacy and safety of Venetoclax combined with multidrug chemotherapy in patients with relapsed or refractory early T-cell precursor acute lymphoblastic leukemia (R/R ETP-ALL) . Methods: This study retrospectively analyzed 15 patients with R/R ETP-ALL who received Venetoclax combined with multidrug chemotherapy from December 2018 to February 2022. Among them, eight cases were combined with demethylated drugs, four cases were combined with demethylated drugs and HAAG chemotherapy regimen, two cases were combined with demethylated drugs and CAG regimen, and one case was combined with Cladribine. Specific usage and dosage of Venetoclax: 100 mg on day 1, 200 mg on day 2, 400 mg on day 3-28, orally; when combined with azole antifungal drugs, dosage was reduced to 100 mg/d. Results: Fifteen patients (10 males and 5 females) with R/R ETP-ALL were treated with Venetoclax and multidrug chemotherapy with a median age of 35 (12-42) years old. Of 4 refractory and 11 relapsed patients, the efficacy was evaluated on the 21th day following combined chemotherapy: the overall response rate, the complete response (CR) rate, and the CR with incomplete hematological recovery (CRi) rate were 67.7% (10/15), 60.0% (9/15), and 6.7% (1/15), respectively. For the overall study population, the 12-month overall survival (OS) rate was 60.0%, and the median OS was 17.7 months. The disease-free survival (DFS) rate of all CR patients at 12 months was 60.0%, and the median DFS did not reach. About 14 patients had Ⅲ-Ⅳ hematological toxicity, but these adverse reactions were all controllable. No adverse reaction in the nervous system and tumor lysis syndrome occurred in this study, and no adverse reaction of organs above grade Ⅲ occurred. Conclusion: Venetoclax combined with multidrug chemotherapy may be a safe and promising treatment option for patients with R/R ETP-ALL.
Male
;
Female
;
Humans
;
Adult
;
Retrospective Studies
;
Treatment Outcome
;
Bridged Bicyclo Compounds, Heterocyclic/therapeutic use*
;
Antineoplastic Combined Chemotherapy Protocols
;
Precursor T-Cell Lymphoblastic Leukemia-Lymphoma/drug therapy*
;
Precursor Cells, T-Lymphoid
;
Leukemia, Myeloid, Acute/drug therapy*
7.Efficacy analysis of selinexor combined with hypomethylating agent in the treatment of refractory/relapsed acute myeloid leukemia exposed to venetoclax.
Jian ZHANG ; Bao Quan SONG ; Xin KONG ; Yin LIU ; Han Lin YANG ; Li Hong ZONG ; Jin Yu KONG ; Yang XU ; Hui Ying QIU ; De Pei WU
Chinese Journal of Hematology 2023;44(11):936-939
8.Application of membrane anatomy in hepatopancreatobiliary and splenic surgery.
Shu You PENG ; Yun JIN ; Jiang Tao LI ; Yuan Quan YU ; Xiu Jun CAI ; De Fei HONG ; Xiao LIANG ; Ying Bin LIU ; Xu An WANG
Chinese Journal of Surgery 2023;61(7):535-539
Understanding of a variety of membranous structures throughout the body,such as the fascia,the serous membrane,is of great importance to surgeons. This is especially valuable in abdominal surgery. With the rise of membrane theory in recent years,membrane anatomy has been widely recognized in the treatment of abdominal tumors,especially of gastrointestinal tumors. In clinical practice. The appropriate choice of intramembranous or extramembranous anatomy is appropriate to achieve precision surgery. Based on the current research results,this article described the application of membrane anatomy in the field of hepatobiliary surgery,pancreatic surgery,and splenic surgery,with the aim of blazed the path from modest beginnings.
Humans
;
Mesentery/surgery*
;
Digestive System Surgical Procedures
;
Fascia/anatomy & histology*
9.Whole-course management strategies for gastroesophageal reflux disease: an evidence mapping study based on clinical practice guidelines.
Xin Yu ZHANG ; Ke Lu YANG ; Xiao Nan LIU ; De Liang YU ; Rui Shu LI ; Ke Wei JIANG ; Quan WANG
Chinese Journal of Gastrointestinal Surgery 2023;26(4):389-395
Gastroesophageal reflux disease (GERD) is one of the most common digestive diseases with high incidence, complicated clinical symptoms, difficulties in standard treatment, and heavy medical burden. At present, some GERD-relevant clinical practice guidelines (CPGs) have been issued by different countries and academic organizations, but some recommendations were inconsistent, which has caused some problems for the current clinical whole-course management of GERD. To summarize the relevant evidence among the CPGs on GERD and formulate the whole- course management strategies, we included GERD-relevant CPGs published or updated after 2010 by searching websites of guidelines, relevant professional societies, and electronic databases. We extracted the recommendations and summarized the evidence from the aspects of symptoms, epidemiology, diagnosis and treatment, which was presented in the form of evidence mapping. We included 24 CPGs, including three in Chinese and 21 in English. The clinical practice management strategies of GERD were formulated based on the evidence from the aspects of clinical symptoms, diagnostic methods, medical treatment, anti-reflux surgery and endoscopic treatment, psychological treatment, and traditional Chinese medicine treatment.
Humans
;
Gastroesophageal Reflux/therapy*
10.Echocardiographic evaluation of left ventricular longitudinal systolic function in patients with atrial septal defect and pulmonary hypertension before and after interventional occlusion
Wu-Xu ZUO ; Yuan-Feng WU ; Quan LI ; Dan-Dan CHEN ; Li-Li DONG ; De-Hong KONG ; Cui-Zhen PAN ; Xian-Hong SHU
Chinese Journal of Clinical Medicine 2023;30(6):927-933
Objective To investigate the dynamic changes of left ventricular longitudinal systolic function in patients with atrial septal defect(ASD)and pulmonary hypertension(PH)before and after interventional occlusion using echocardiography.Methods A total of 57 patients undergoing interventional occlusion in Zhongshan Hospital,Fudan University from September 2015 to January 2016 were enrolled.Patients were divided into PH group and non-PH group.Echocardiographic examinations were performed for all subjects one day before,one day after and 1-6 months after the interventional occlusion.Twenty healthy individuals were included as a control group.Global and regional longitudinal strain(LS)of the left ventricle were analyzed using TomTec software.Results There were 27 patients in the PH group and 30 patients in the non-PH group.At baseline,tricuspid annular plane systolic excursion(TAPSE)and tissue Doppler velocity of tricuspid annulus S'in both the PH and non-PH groups were higher than those in the control group(P<0.05).Longitudinal systolic function of the right ventricle decreased significantly on the first day after occlusion(P<0.05),and slightly increased 1-6 months after occlusion.Patients in the non-PH group showed a decreased LS in a small portion of the left ventricular segments 1 d and 1-6 months after occlusion(P<0.05);patients in the PH group showed a decreased left ventricular global longitudinal strain(GLS)on the first day after occlusion(P<0.05),primarily was in the basal and middle parts of the ventricle(P<0.05),without significant change in the apical part,and the LS of the left ventricle tended to increase 1-6 months after occlusion.Conclusions With or without PH,longitudinal movement of the right ventricle in ASD patient is excessive before occlusion,and gradually improves after occlusion.Left ventricular GLS decreases in ASD patients with PH,with segmental differences 1 day after occlusion.

Result Analysis
Print
Save
E-mail