1.Molecular biological mechanism of acquired heterotopic ossification
Yang XIONG ; Shibo ZHOU ; Xing YU ; Lianyong BI ; Jizhou YANG ; Fengxian WANG ; Yi QU ; Yongdong YANG ; Dingyan ZHAO ; He ZHAO ; Ziye QIU ; Guozheng JIANG
Chinese Journal of Tissue Engineering Research 2024;28(30):4881-4888
BACKGROUND:Heterotopic ossification is a dynamic growth process.Diverse heterotopic ossification subtypes have diverse etiologies or induction factors,but they exhibit a similar clinical process in the intermediate and later phases of the disease.Acquired heterotopic ossification produced by trauma and other circumstances has a high incidence. OBJECTIVE:To summarize the molecular biological mechanisms linked to the occurrence and progression of acquired heterotopic ossification in recent years. METHODS:The keywords"molecular biology,heterotopic ossification,mechanisms"were searched in CNKI,Wanfang,PubMed,Embase,Web of Science,and Google Scholar databases for articles published from January 2016 to August 2022.Supplementary searches were conducted based on the obtained articles.After the collected literature was screened,131 articles were finally included and summarized. RESULTS AND CONCLUSION:(1)The occurrence and development of acquired heterotopic ossification is a dynamic process with certain concealment,making diagnosis and treatment of the disease difficult.(2)By reviewing relevant literature,it was found that acquired heterotopic ossification involves signaling pathways such as bone morphogenetic protein,transforming growth factor-β,Hedgehog,Wnt,and mTOR,as well as core factors such as Runx-2,vascular endothelial growth factor,hypoxia-inducing factor,fibroblast growth factor,and Sox9.The core mechanism may be the interaction between different signaling pathways,affecting the body's osteoblast precursor cells,osteoblast microenvironment,and related cytokines,thereby affecting the body's bone metabolism and leading to the occurrence of acquired heterotopic ossification.(3)In the future,it is possible to take the heterotopic ossification-related single-cell osteogenic homeostasis as the research direction,take the osteoblast precursor cells-osteogenic microenvironment-signaling pathways and cytokines as the research elements,explore the characteristics of each element under different temporal and spatial conditions,compare the similarities and differences of the osteogenic homeostasis of different types and individuals,observe the regulatory mechanism of the molecular signaling network of heterotopic ossification from a holistic perspective.It is beneficial to the exploration of new methods for the future clinical prevention and treatment of heterotopic ossification.(4)Meanwhile,the treatment methods represented by traditional Chinese medicine and targeted therapy have become research hotspots in recent years.How to link traditional Chinese medicine with the osteogenic homeostasis in the body and combine it with targeted therapy is also one of the future research directions.(5)At present,the research on acquired heterotopic ossification is still limited to basic experimental research and the clinical prevention and treatment methods still have defects such as uncertain efficacy and obvious side effects.The safety and effectiveness of relevant targeted prevention and treatment drugs in clinical application still need to be verified.Future research should focus on clinical prevention and treatment based on basic experimental research combined with the mechanism of occurrence and development.
2.Efficacy of oral midazolam solution for preoperative sedation in pediatric outpatients undergoing root canal treatment under general anesthesia
Zhihu YANG ; Fei XING ; Dan CHENG ; Mingcui QU ; Tongtong ZHANG ; Na XING
Chinese Journal of Anesthesiology 2024;44(1):53-57
Objective:To evaluate the efficacy of oral midazolam solution for preoperative sedation in the pediatric outpatients undergoing root canal treatment under general anesthesia.Methods:One hundred and forty-seven pediatric patients of either sex, aged 2-7 yr, weighing 10-30 kg, of American Society of Anesthesiologists Physical Status classificationⅠ or Ⅱ, were divided into 3 groups ( n=49 each) using a random number table method: oral midazolam solution group (OM group), midazolam injection group (M group), and dexmedetomidine group (D group). In OM group, patients received oral midazolam solution at a dose of 0.5 mg/kg along with a placebo (an equivalent amount of normal saline based on body weight) administered via nasal drops. In M group, patients were given oral midazolam injection at a dose of 0.5 mg/kg along with a placebo via nasal drops. In D group, patients were administered a placebo orally along with dexmedetomidine at a dose of 2 μg/kg via nasal drops. The Induction Compliance Checklist (ICC) scores upon entering the operating room, sedation success rates (ICC score ≤ 3), drug acceptance scores, mask acceptance scores, and separation anxiety scores were recorded. The emergence time, time of stay in postanesthesia care unit (PACU), and occurrence of adverse events such as bradycardia, hypotension, hypoxemia, and laryngospasm during surgery and in PACU were recorded. Results:A total of 143 pediatric patients were finally included in the study, with 48 cases in OM group, 48 cases in M group and 47 cases in D group. Compared with M and D groups, the ICC scores upon entry to the operating room were significantly decreased, the sedation success rates were increased, drug acceptance scores were increased, separation anxiety scores were decreased, and mask acceptance scores were decreased in OM group ( P<0.05). Compared with D group, the ICC scores upon entry to the operating room were significantly decreased, the sedation success rates were increased, and mask acceptance scores were decreased in M group ( P<0.05). There were no statistically significant differences in the emergence time, time of stay in PACU, and incidence of adverse events during surgery and in PACU among the three groups ( P>0.05). Conclusions:Oral midazolam solution provides good effect with less adverse reactions when used for preoperative sedation in the pediatric outpatients undergoing root canal treatment under general anesthesia.
3.Early coagulation function changes of penetrating intestinal firearm injury of pigs in high-altitude environment
Jiu SUN ; Xue YANG ; Jinquan QU ; Xinyue YANG ; Caifu SHEN ; Jiajia LI ; Yanchao XING ; Jiangwei LIU
Chinese Journal of Trauma 2024;40(3):257-265
Objective:To explore the early coagulation function changes of penetrating intestinal firearm injury of pig in high-altitude environments.Methods:Twenty healthy long white piglets were selected and divided into the plain group and the high-altitude group using the random number table method, with 10 pigs in each group. Pigs in the plain group were placed in a plain environment at an altitude of 800 meters, while pigs in the high-altitude group were placed in an experimental chamber simulating an altitude of 6 000 meters for 48 hours. Both groups received pistol gunshot to have firearm penetrating wounds to the abdominal intestinal tract and then returned to the plain observation room. At 0, 2, 4, 8, 12 and 24 hours after injury, coagulation in the peripheral blood and fibrinolytic indexes [prothrombin time (PT), activated partial thromboplastin time (APTT), thrombin time (TT), fibrinogen (Fbg), D-dimer (D-D), and fibrinogen degradation product (FDP)], thromboelastogram (TEG) [reaction time (R), clotting time (K), clot formation rate (α), maximum amplitude (MA) and coagulation composite index (CI) ], platelet parameters [platelet count (PLT), mean platelet volume (MPV), platelet distribution width (PDW), and platelet-large cell ratio (P-LCR)] in the two groups were detected separately.Results:The PT values at 0 and 2 hours after injury in the high-altitude group were significantly lower than those in the plain group, while they were significantly higher at 8, 12 and 24 hours than those in the plain group ( P<0.01); there was no significant difference at 4 hours between the two groups ( P>0.05). The APTT values at 0, 2 and 4 hours after injury in the high-altitude group were significantly lower than those in the plain group, while they were significantly higher at 8, 12 and 24 hours after injury than those in the plain group ( P<0.01). The TT values at 0, 2 and 4 hours after the injury in the high-altitude group were significantly lower than those in the plain group, while they were significantly higher at 12 and 24 hours after injury than those in the plain group ( P<0.01); there was no significant difference at 8 hours after injury between the two groups ( P>0.05). The Fbg, D-D and FDP values at 0, 2, 4, 8, 12 and 24 hours after injury were higher in the high-altitude group than those in the plain group ( P<0.01). The R values at 0, 2 and 4 hours after injury in the high-altitude group were significantly lower than those in the plain group, while they were significantly higher at 8, 12 and 24 hours after injury than those in the plain group ( P<0.01). The K values at 0, 2, 4 and 8 hours after injury in the high-altitude group were significantly lower than those in the plain group, while they were significantly higher at 12 and 24 hours after injury than those in the plain group ( P<0.05 or 0.01). The α angles at 0, 2 and 4 hours after injury in the high-altitude group were significantly higher than those in the plain group, while they were significantly lower at 8, 12 and 24 hours after injury than those in the plain group ( P<0.01). The MA values at 0, 2 and 4 hours after the injury in the high-altitude group were significantly higher than those in the plain group, while they were significantly lower at 8, 12 and 24 hours after injury than those in the plain group ( P<0.01). The CI values at 0, 2 and 4 hours after injury in the high-altitude group were significantly higher than those in the plain group, while they were significantly lower at 8, 12 and 24 hours after injury than those in the plain group ( P<0.01). The PLT values at 0, 2, 4 and 8 hours after injury in the high-altitude group were significantly higher than those in the plain group, while they were significantly lower at 12 and 24 hours after injury than those in the plain group ( P<0.05 or 0.01). The MPV values at 0, 2, 4, 8, 12 and 24 hours after injury in the high-altitude group were significantly higher than those in the plain group ( P<0.01). The PDW values at 2, 4, 8, 12 and 24 hours after injury in the high-altitude group were significantly higher than those in the plain group ( P<0.05 or 0.01), while there was no significant difference in PDW at 0 hour after injury between the two groups ( P>0.05). The P-LCR values at 0, 2, 4, 8, 12 and 24 hours after injury in the high-altitude group were all significantly higher than those in the plain group ( P<0.01). Conclusion:Compared with the plain environments, pig intestinal firearm penetrating injury in the high-altitude environments is more prone to early hypercoagulable state accompanied by mild hyperfibrinolysis, and faster to reach a hypocoagulable state accompanied by obvious hyperfibrinolysis.
4.A New Multifunctional Biosensor Based on a Hairpin Oligonucleotide Probe and G-Quadruplex/Hemin DNAzyme
Lei WANG ; Ji-Xiang SONG ; Xing-Feng LIU ; Yan-Qin HUANG ; Qu-Li FAN
Chinese Journal of Analytical Chemistry 2024;52(8):1123-1131
A new multifunctional fluorescent"turn-on"biosensor was constructed based on a guanine-rich hairpin probe and G-quadruplex/hemin DNAzyme.The probe was labeled with quencher and fluorescein at 5′and 3′terminus,respectively.In the absence of the target,the probe form hairpin structure and the fluorescence of the fluorescein was quenched by the quencher.However,in the presence of the target,the hairpin structure transformed to G-quadruplex and the fluorescence was recovered.By monitoring the fluorescence of the probe before and after combining with the target,both hemin and hemoglobin were detected rapidly and conveniently with high sensitivity.The limit of detection for hemin and hemoglobin were estimated to be 283 pmol/L and 109 pmol/L,respectively.The specific interaction between the DNA probe and hemin were investigated via absorption and fluorescence spectra.Furthermore,L-cysteine was detected with naked eyes based on the peroxidase-like activity of the new G-quadruplex/hemin DNAzyme.The limit of detection for L-cysteine was estimated to be 3.6 μmol/L,which was lower than the normal level of intracellular L-cysteine(30-200 μmol/L).The method developed here was rapid,simple and sensitive for detection of hemin,hemoglobin and L-cysteine,demonstrating great potential in bioanalysis,drug screening,and disease diagnosis.
5.Evaluation of disinfection effect of high-energy pulse ultraviolet disinfection equipment in medical institution settings
Zhengchun SUN ; Jincai ZHU ; Tingting ZHU ; Xiaorong QU ; Nan LI ; Yuxin ZHAO ; Shuang WANG ; Xiaodong YUAN ; Guoliang LI ; Nengwei ZHANG ; Yi XING ; Qi YAO
Chinese Journal of Preventive Medicine 2024;58(6):857-861
Objective:To evaluate the disinfection effect of high-energy pulse ultraviolet disinfection equipment in medical institution settings.Methods:The disinfection effect was evaluated through field tests and laboratory tests. Among them, 135 high-frequency contact points were selected from nine departments in the field test. Samples were collected before and after disinfection, and the disinfection effects of 75% alcohol wipes wiping disinfection, high-energy pulse ultraviolet disinfection robot disinfection and high-energy pulse ultraviolet handheld disinfection instrument were compared. In the laboratory test, 30 infected areas of the simulated test table were exposed to vertical ultraviolet irradiation and the bacterial-killing rate before and after disinfection was calculated.Results:In the field test, the bacteria-killing rates of 75% alcohol wipes, high-energy pulse ultraviolet disinfection robot and high-energy pulse ultraviolet handheld disinfection instrument were 94.99%, 91.53% and 95.94%, respectively, and the difference was statistically significant. The disinfection effect of the high-energy pulse ultraviolet handheld disinfection instrument was better than that of the high-energy pulse ultraviolet disinfection robot ( P values <0.05). In the laboratory test, the killing log value of Staphylococcus aureus and Escherichia coli on the carrier were both greater than 3.00. In the simulated field test, the killing log value of Staphylococcus aureus on the surface samples were 4.99. Conclusion:Both the high-energy pulse ultraviolet handheld disinfection instrument and the high-energy pulse ultraviolet disinfection robot have good disinfection effects, which are similar to the disinfection effects of conventional 75% alcohol wipes.
6.Prediction of Screw Loosening After Dynamic Pedicle Screw Fixation With Lumbar Polyetheretherketone Rods Using Magnetic Resonance Imaging-Based Vertebral Bone Quality Score
Guozheng JIANG ; Luchun XU ; Yukun MA ; Jianbin GUAN ; Yongdong YANG ; Wenqing ZHONG ; Wenhao LI ; Shibo ZHOU ; JiaWei SONG ; Ningning FENG ; Ziye QIU ; Zeyu LI ; YiShu ZHOU ; Letian MENG ; Yi QU ; Xing YU
Neurospine 2024;21(2):712-720
Objective:
To investigate the correlation between magnetic resonance imaging-based vertebral bone quality (VBQ) score and screw loosening after dynamic pedicle screw fixation with polyetheretherketone (PEEK) rods, and evaluate its predictive value.
Methods:
A retrospective analysis was conducted on the patients who underwent dynamic pedicle screw fixation with PEEK rods from March 2017 to June 2022. Data on age, sex, body mass index, hypertension, diabetes, hyperlipidemia history, long-term smoking, alcohol consumption, VBQ score, L1–4 average Hounsfield unit (HU) value, surgical fixation length, and the lowest instrumented vertebra were collected. Logistic regression analysis was employed to assess the relationship between VBQ score and pedicle screw loosening (PSL).
Results:
A total of 24 patients experienced PSL after surgery (20.5%). PSL group and non-PSL group showed statistical differences in age, number of fixed segments, fixation to the sacrum, L1–4 average HU value, and VBQ score (p < 0.05). The VBQ score in the PSL group was higher than that in the non-PSL group (3.56 ± 0.45 vs. 2.77 ± 0.31, p < 0.001). In logistic regression analysis, VBQ score (odds ratio, 3.425; 95% confidence interval, 1.552–8.279) were identified as independent risk factors for screw loosening. The area under the receiver operating characteristic curve for VBQ score predicting PSL was 0.819 (p < 0.05), with the optimal threshold of 3.15 (sensitivity, 83.1%; specificity, 80.5%).
Conclusion
The VBQ score can independently predict postoperative screw loosening in patients undergoing lumbar dynamic pedicle screw fixation with PEEK rods, and its predictive value is comparable to HU value.
7.Echocardiographic study on the diurnal changes of the exercise adaptability of cardiac function in healthy men with different ages
Xiangwu WANG ; Changyang XING ; Yang QU ; Wei HU ; Lijun YUAN
Chinese Journal of Ultrasonography 2024;33(5):415-420
Objective:To reveal the diurnal variation characteristics of the exercise adaptability of cardiac function in healthy men of different ages by the analysis of echocardiographic parameter changes before and after exercise intervention using the left ventricular pressure-strain loop techniques.Methods:A prospective control design was used to collect 193 healthy male volunteers from October 2022 to July 2023 in Tangdu Hospital, 101 in the young group [(26±5) years old], and 92 in the middle-aged group [(50±4) years old]. The heart rate, blood pressure and routine echocardiographic parameters were collected at rest and after exercise stress (3-minute step test) at 7∶00 a.m.and 10∶00 p.m., respectively. The heart rate, blood pressure cardiac output, and echocardiographic parameters [anteroposterior diameter of left atrium (LAD), ratio of peak early diastolic flow velocity to late diastolic peak flow velocity of mitral valve (E/A), left ventricular ejection fraction (LVEF), left ventricular end diastolic diameter (LVEDD), left ventricular end systolic diameter (LVEDS)] were then determined. The parameters of myocardial work including left ventricular longitudinal strain (GLS), global work index (GWI), global work efficiency (GWE), global constructive work (GCW) and global wasted work (GWW) were obtained by left ventricular pressure-strain loop technique. The differences of the parameters above between before and after step test, morning and night, young group and middle-aged group were compared.Results:The heart rate, blood pressure and cardiac output of young and middle-aged healthy men increased significantly in the morning and night step test (all P<0.05), GLS, GWI, GCW and GWW were significantly higher than those in resting state (all P<0.05), and GWE was significantly lower than that in resting state ( P<0.05). The change rates of heart rate, cardiac output, GLS, GWI and GCW in the early morning were significantly higher than those at night (all P<0.05), while the change rates of blood pressure and GWE in each group were significantly lower than those at night ( P<0.05). The change rates of heart rate, systolic blood pressure, GLS and GWI in the middle-aged group were significantly higher than those in the young group in the morning and night (all P<0.05), while the change rate of diastolic blood pressure at night was significantly higher than that in the young group ( P<0.05), but there was no significant difference in the morning ( P>0.05). Conclusions:The cardiac adaptability of healthy men has obvious circadian rhythm, characterized by being of low in the morning and high in the evening. Age mainly affects the cardiac adaptability in the morning. The response to low-intensity load stimulation increases with aging, indicating the decrease of morning cardiac adaptability.
8.Research on the clinical application effect of transcranial ultrasound patch probe
Bin ZHANG ; Changyang XING ; Wei HU ; Yang QU ; Jia WANG ; Xi ZHANG ; Yunyou DUAN ; Tiesheng CAO ; Lijun YUAN
Chinese Journal of Ultrasonography 2024;33(8):697-702
Objective:To evaluate the performance of the self-developed transcranial ultrasound patch probe as well as its stability and safety in clinical applications.Methods:This study was a cross-sectional study. Fifty healthy subjects in Tangdu Hospital from October to December 2023 were randomly and equally divided into two groups using a simple randomization method. The transcranial Doppler ultrasound (TCD) examinations were performed using the self-developed transcranial ultrasound patch probe and normal TCD probe alternatively in each group from squatting to sitting and then to standing posture. Two experienced sonographers (A, B) each completed one test for the same subject using the above two different probes. The differences of the ultrasound parameters of middle cerebral artery (MCA) blood flow measured by the self-developed transcranial ultrasound patch probe and the normal TCD probe in different postures (squatting, sitting, standing) were compared. At the same time, operator satisfaction with the use of the two probes was assessed in terms of time taken to obtain satisfactory images, operational comfort, and ease of handling. In addition, the subject's comfort during the examination was examined, and the signal acquisition stability of the two probes was comprehensively evaluated.Results:There was no significant difference in detection of various ultrasound parameters of MCA between using the transcranial patch probe and the normal TCD probe (all P>0.05). The overall satisfaction of transcranial ultrasound patch probe and normal TCD probe was quite similar. The transcranial ultrasound patch probe acquired favorable and stable signals. No subjects experienced adverse events/accidents during the examination of the subjects using the transcranial ultrasound patch probe as well as the normal TCD probe.Both probes had good and stable signal acquisition. Conclusions:TCD examinations could be well performed using the transcranial ultrasound patch probe, which might provide a potential new method for real-time monitoring and evaluating of cerebral blood flow of a moving subject.
9.Evaluation of disinfection effect of high-energy pulse ultraviolet disinfection equipment in medical institution settings
Zhengchun SUN ; Jincai ZHU ; Tingting ZHU ; Xiaorong QU ; Nan LI ; Yuxin ZHAO ; Shuang WANG ; Xiaodong YUAN ; Guoliang LI ; Nengwei ZHANG ; Yi XING ; Qi YAO
Chinese Journal of Preventive Medicine 2024;58(6):857-861
Objective:To evaluate the disinfection effect of high-energy pulse ultraviolet disinfection equipment in medical institution settings.Methods:The disinfection effect was evaluated through field tests and laboratory tests. Among them, 135 high-frequency contact points were selected from nine departments in the field test. Samples were collected before and after disinfection, and the disinfection effects of 75% alcohol wipes wiping disinfection, high-energy pulse ultraviolet disinfection robot disinfection and high-energy pulse ultraviolet handheld disinfection instrument were compared. In the laboratory test, 30 infected areas of the simulated test table were exposed to vertical ultraviolet irradiation and the bacterial-killing rate before and after disinfection was calculated.Results:In the field test, the bacteria-killing rates of 75% alcohol wipes, high-energy pulse ultraviolet disinfection robot and high-energy pulse ultraviolet handheld disinfection instrument were 94.99%, 91.53% and 95.94%, respectively, and the difference was statistically significant. The disinfection effect of the high-energy pulse ultraviolet handheld disinfection instrument was better than that of the high-energy pulse ultraviolet disinfection robot ( P values <0.05). In the laboratory test, the killing log value of Staphylococcus aureus and Escherichia coli on the carrier were both greater than 3.00. In the simulated field test, the killing log value of Staphylococcus aureus on the surface samples were 4.99. Conclusion:Both the high-energy pulse ultraviolet handheld disinfection instrument and the high-energy pulse ultraviolet disinfection robot have good disinfection effects, which are similar to the disinfection effects of conventional 75% alcohol wipes.
10.Expression of miR-142 and its relationship with Th17/Treg imbalance in children with autoimmune thyroid disease
Ping LUO ; Yan-Mei XIN ; Qu-Lian GUO ; Xing SHEN
Chinese Journal of Contemporary Pediatrics 2024;26(6):605-610
Objective To investigate the expression of microRNA-142(miR-142)in children with autoimmune thyroid disease(AITD)and its relationship with the imbalance of helper T cell 17(Th17)and regulatory T cell(Treg).Methods A total of 89 children hospitalized for AITD from January 2019 to December 2022 were prospectively selected as the study subjects,including 48 children with Graves'disease(GD group)and 41 children with Hashimoto's thyroiditis(HT group).Additionally,55 healthy children undergoing physical examinations during the same period were selected as the control group.The differences in serum miR-142,antithyroglobulin antibody(TGAb),antithyroperoxidase antibody(TPOAb),Th17/Treg,and interleukin-17(IL-17)expression were compared among the groups.Results The expression of miR-142,TPOAb,TGAb,Th17,Th17/Treg,and IL-17 in the GD group and HT group was higher than that in the control group,while Treg was lower than that in the control group(P<0.05).Pearson correlation analysis revealed that in the GD group,miR-142 was positively correlated with TPOAb,TGAb,Th17,Th17/Treg,and IL-17(r=0.711,0.728,0.785,0.716,0.709,respectively;P<0.001)and negatively correlated with Treg(r=-0.725,P<0.001);in the HT group,miR-142 was positively correlated with TPOAb and TGAb(r=0.752,0.717,respectively;P<0.001).Conclusions miR-142 is highly expressed in children with AITD,and its expression may be related to the Th17/Treg imbalance in children with GD.

Result Analysis
Print
Save
E-mail