1.Measurement and analysis of radiation doses received by the human body and radiation levels in the CT room under digital miniature CT scanning conditions
Lin YIN ; Zhenhua YANG ; Yaqi XI ; Wenlong FAN ; Rui YANG ; Qisheng XIA ; Qiaoling WU
Chinese Journal of Radiological Health 2025;34(3):373-377
Objective To evaluate the radiation impact of a self-developed digital miniature CT on the human body and the environment under simulated scanning conditions, and verify its safety and regulatory compliance. Methods Under typical head scanning conditions with the digital miniature CT (70 kV/10 mA), the equivalent doses received at the body surface sites corresponding to the thyroid, breast, stomach, liver, kidney, and gonads of the phantom were measured without protection and with 0.5 mmPb equivalent protection using LiF (Mg, Cu, P) thermoluminescent dosimeters. The ambient dose equivalent rates at the bed level inside the CT room at different directions and distances from the scanning center were measured using a model AT1121 X/γ dosimeter. The equivalent doses of organs on both sides of the phantom and the ambient equivalent dose rates on the left and right sides of the longitudinal axis of the bed in the CT room were compared. The Mann-Whitney test was used at a significance level of P < 0.05. Results During a single scan of the head with the digital miniature CT, the equivalent doses at the body surface sites corresponding to the thyroid, breast, stomach, liver, kidney, and gonads without protection were 1.04, 0.95, 0.55, 0.57, 0.40, and 0.12 mSv, respectively, which were only 0.84% to 8.24% of the doses inside the irradiation field. With 0.5 mm Pb equivalent protection, the equivalent dose of the thyroid decreased from 8.24 mSv to 3.27 mSv with a reduction of 60.3%, and the doses of the other organs were reduced to 1.5-11.5 μSv with the maximum reduction of 14 times. In the longitudinal axis direction of the CT bed, the ambient dose equivalent rate at a distance of 2 m from the scanning center was reduced to 0.066 mSv/h, which was only 9.6% of the ambient equivalent dose rate at a distance of 50 cm from the scanning center. Conclusion The digital miniature CT has advantages in ensuring patient safety, optimizing imaging quality, and promoting technological development, demonstrating promising application potential. However, the radiation protection of personal and CT room should not be ignored.
2.Investigation and analysis of the current situation of medical equipment allocation in 103 tertiary public hospitals
Huifang YAN ; Zhanguo LI ; Qiaoling WU ; Jing ZHAO
China Medical Equipment 2024;21(1):147-151,160
Objective:To investigate the current situation of medical equipment allocation in 103 tertiary public hospitals,analyze and compare the proportion of medical equipment in different regional hospitals in our country,and provide basis for scientific and reasonable allocation of medical equipment.Methods:A questionnaire was designed by literature research and expert consultation,and an electronic questionnaire was released through the public account of"China Medical Equipment"and the platform of"Good Medical Workers"to analyze the correlation between the number of medical equipment configuration,the proportion of domestic products,the region where the hospital was located and the number of hospital beds.Results:A total of 103 valid questionnaires were collected,involving 103 tertiary public hospitals in East China,North China,Central China,South China,Southwest,Northwest and Northeast China,of which 18%were in North China,37%were in East China and 9%were in South China.In North China,South China and East China,the average number of medical equipment in the tertiary public hospitals in the region was 9785 units per hospital,9245 units per hospital and 8153 units per hospital,and the number of the expensive equipment was relatively small,which had no correlation with the number of beds.There were statistically significant differences between North China and East China in the number of beds,the number of pieces of equipment per 100 beds and the amount of equipment per 100 beds(t=-2.582,2.939,4.653,P<0.05).The number of life support equipment configuration was significantly positively correlated with the number of beds,and the domestic share,especially the domestic share of life support equipment,increased.Conclusion:The analysis of medical equipment allocation in public hospitals in China can provide data support for hospitals to better adapt to the adjustment of the new expensive medical equipment catalogue,provide reference for the demonstration and promotion of large medical equipment allocation and localization in tertiary hospitals,and provide reference for relevant health management departments.
3.Monte Carlo simulation-based optimization of the rivaroxaban regimen for anticoagulation in patients with different classes of renal function
Qiaoling YU ; Weiwei ZHAI ; Yumeng LI ; Panpan JIN ; Bo QIU ; Huizhen WU
China Pharmacy 2024;35(24):3016-3022
OBJECTIVE To optimize the rivaroxaban dosing regimen for anticoagulation in patients with different renal function levels. METHODS The administration regimen was determined based on the drug instructions for rivaroxaban and the actual medication situation of the patient. The target concentration range and the subsection interval were established using rivaroxaban blood minimum concentration for patients from Hebei General Hospital and reference range of rivaroxaban laboratory monitoring concentration recommended by International Council for Standardization in Hematology. The probability of different dosing regimens in each target concentration range was investigated with Monte Carlo simulation using Oracle Crystal Ball software (V11.1.2.4). RESULTS A total of 97 patients with non-valvular atrial fibrillation were enrolled and the minimum concentration of rivaroxaban was tested 125 times with a median trough concentration of 32.2 ng/mL; a total of 121 patients with venous thrombosis were enrolled and the minimum concentration was tested 159 times with a median minimum concentration of 31.0 ng/mL. The reference range for steady-state minimum concentration in patients with non-valvular atrial fibrillation was 12-137 and 3-153 ng/mL, while the reference range for steady-state minimum concentration in patients with venous thrombosis was 6-239 and 3-224 ng/mL. Monte Carlo simulation results showed that in patients with non-valvular atrial fibrillation, the optimal rivaroxaban dosing regimen for patients with glomerular filtration rate (eGFR) 0-30 mL/min was 5 mg once daily; for patients with eGFR>30-60 mL/min, the optimal dosing regimen was 10-20 mg once daily or 5 mg twice daily; for patients with eGFR>60-90 mL/min, the optimal dosing regimen was 15-30 mg once daily or 5-10 mg twice daily; for patients with eGFR>90-120 mL/min, the optimal dosing regimen was 25-30 mg once daily or 5-15 mg twice daily. For patients with venous thrombosis, it is not recommended to use rivaroxaban more than 5 mg once daily for patients with eGFR 0-30 mL/min; the optimal dosing regimens of rivaroxaban were 5 mg once daily for patients with eGFR>30-60 mL/min, 25- 30 mg once daily or 5-15 mg twice daily for patients with eGFR>60-90 mL/min, 10-15 mg twice daily for patients with eGFR> 90-120 mL/min. CONCLUSIONS Rivaroxaban should be selected carefully as the anticoagulants for patients with severe renal function impairment. Rivaroxaban possesses a wide reference range in the minimum concentration and considerable individual variability. The dosage and frequency of rivaroxaban can be personalized through the Monte Carlo simulation method, taking into account patients’ renal function.
4.Background, design, and preliminary implementation of China prospective multicenter birth cohort
Si ZHOU ; Liping GUAN ; Hanbo ZHANG ; Wenzhi YANG ; Qiaoling GENG ; Niya ZHOU ; Wenrui ZHAO ; Jia LI ; Zhiguang ZHAO ; Xi PU ; Dan ZHENG ; Hua JIN ; Fei HOU ; Jie GAO ; Wendi WANG ; Xiaohua WANG ; Aiju LIU ; Luming SUN ; Jing YI ; Zhang MAO ; Zhixu QIU ; Shuzhen WU ; Dongqun HUANG ; Xiaohang CHEN ; Fengxiang WEI ; Lianshuai ZHENG ; Xiao YANG ; Jianguo ZHANG ; Zhongjun LI ; Qingsong LIU ; Leilei WANG ; Lijian ZHAO ; Hongbo QI
Chinese Journal of Perinatal Medicine 2024;27(9):750-755
China prospective multicenter birth cohort (Prospective Omics Health Atlas birth cohort, POHA birth cohort) study was officially launched in 2022. This study, in collaboration with 12 participating units, aims to establish a high-quality, multidimensional cohort comprising 20 000 naturally conceived families and assisted reproductive families. The study involves long-term follow-up of parents and offspring, with corresponding biological samples collected at key time points. Through multi-omics testing and analysis, the study aims to conduct multi-omics big data research across the entire maternal and infant life cycle. The goal is to identify new biomarkers for maternal and infant diseases and provide scientific evidence for risk prediction related to maternal diseases and neonatal health.
5.Analysis and Strategic Research on the Students'Achievement of Chinese Medicine Based on the Medical Licensing Examina-tion Empirical Research of Traditional Chinese Medicine Physician
Qiaoling SONG ; Jiannong WU ; Xiangfu GAO
Journal of Zhejiang Chinese Medical University 2024;48(7):848-854
[Objective]To summarize and analyze the educational quality and problems of Traditional Chinese Medicine students in Zhejiang Chinese Medical University,and provide reference for improving the teaching quality and students'clinical knowledge and skills.[Methods]Taking the students of Traditional Chinese Medicine who participated in the step-1 medical licensing examination empirical research in Zhejiang Chinese Medical University from 2018 to 2020 as the research objects,the data was analyzed by variance analysis and χ2 test.[Results]Staged examination scores could reflect students'academic performance,the average passing rate of theoretical examination was 68.64%,and the average passing rate of skill assessment was 95.27%.The average total mastery rate of theoretical examination was 65.06%,including basic medicine(55.57%)and clinical medicine(52.12%),whose comparison with the total mastery rate of theoretical examination was statistically significant(P<0.05).The total mastery rate of skill assessment was 76.57%,and the average mastery rates of stations 3~4(physical examination)were 71.24%and 72.24%,whose comparison with the total mastery rate of skill assessment was statistically significant(P<0.05).It proposed improvement measures and strategies such as establishing exam incentive mechanisms to enhance students'internal motivation in exams,strengthening clinical medicine course training to improve staged examination pass rates of theoretical part,and repeatedly training clinical skills to fill the gaps in skill assessment.[Conclusion]Traditional Chinese medicine universities can improve the clinical knowledge and skills of students by establishing examination incentive mechanisms,strengthening clinical medicine course training and repeating clinical skill training,so as to improve the quality of training for students majoring in Traditional Chinese Medicine.
6.Efficacy and safety of new oral anticoagulants in patients with nonvalvular atrial fibrillation after left atrial appendage occlusion:a meta-analysis
Qiaoling YU ; Weiwei ZHAI ; Ping LIU ; Bo QIU ; Huizhen WU
China Pharmacy 2023;34(16):2008-2013
OBJECTIVE To systematically evaluate the efficacy and safety of new oral anticoagulants (NOACs) in patients with nonvalvular atrial fibrillation after left atrial appendage occlusion (LAAO). METHODS Retrieved from PubMed, Embase, Web of Science, the Cochrane Library, CNKI and Wanfang data, randomized controlled trials (RCTs) and cohort studies about NOACs (trial group) versus warfarin or dual antiplatelet agents (control group) were collected during the inception and November 2022. After literature screening, data extraction and quality evaluation, meta-analysis was performed by using RevMan 5.4 software. RESULTS A total of 10 studies were included, involving 2 RCTs and 8 cohort studies, with a total of 2 653 patients. RCT results showed that there was no statistically significant difference in the incidence of device-related thrombosis (DRT), stroke/ systemic embolism (SSE), major bleeding events, total bleeding events or all-cause mortality between 2 groups (P>0.05). Results of cohort studies showed that compared with dual antiplatelet agents, there was no statistically significant difference in the incidence of DRT, stroke/SSE, major bleeding events or all-cause mortality in the trial group (P>0.05). Compared with warfarin, the incidence of DRT [RR=0.40, 95%CI (0.19,0.82), P=0.01] and total bleeding events [RR=0.28, 95%CI (0.18, 0.44), P< 0.000 01] in the trial group were decreased significantly; there was no statistical significance in the incidence of stroke/SSE, major bleeding events or all-cause mortality (P>0.05). CONCLUSIONS For patients with nonvalvular atrial fibrillation after LAAO, NOACs have comparable antithrombotic efficacy and safety with dual antiplatelet agents, and the incidence of DRT and total bleeding events are lower than warfarin.
7. Research progress in plasma concentration monitoring of rivaroxaban
Qiaoling YU ; Weiwei ZHAI ; Ping LIU ; Huizhen WU ; Qiaoling YU ; Weiwei ZHAI ; Ping LIU ; Bo QIU ; Huizhen WU
Chinese Journal of Clinical Pharmacology and Therapeutics 2023;28(7):809-817
Rivaroxaban, a novel oral anticoagulant drug, is widely prescribed in clinical practice. Rivaroxaban offers predictable pharmacokinetic and pharmacodynamic properties, a lowprobability of drug-drug and food-drug interactions. Compared with warfarin, rivaroxaban does not require continuous therapeutic monitoring and can be administered in fixed doses.However,in certain emergency clinical situations, such as bleeding, acute stroke, acute kidney injury, prior to urgent surgery and in the suspected accumulation of durg, plasma concentration monitoring of rivaroxaban is necessary and important for patients. Existing studies proved that there were significant individual variability and wide range in the plasma rivaroxaban concentration, which increased the risk of clinical use. Therefore, Data in the degree of rivaroxaban concentration may provide recommendations for the clinical application to promote medication safety and individuality in the future. This article collected the latest literatures and case reports related to research progress of rivaroxaban plasma concentration monitoring, and Summarized influencing factors, monitoring methods, so as to provide a basis for further study on rational use of rivaroxaban in clinical.
8.Effects of different radiation doses on the accuracy of quantitative iodine concentration and CT value of virtual monochromatic image in second-generation dual-layer detector spectral CT
Qiaoling WU ; Junping TIAN ; Daming ZHANG ; Zhengyu JIN ; Xiaomei LU ; Shenghui YU ; Yun WANG
Basic & Clinical Medicine 2023;43(12):1866-1870
Objective To investigate the effect of different radiation doses on the accuracy of iodine quantification and CT value of virtual monochromatic image with a muti-spectral CT iodine phantom using second-generation dual-layer detector spectral CT(DLCT).Methods The second-generation DLCT scan abdominal phantom was used,which consisted of six different concentrations of iodine rods at 4,8 and 12 g/L.The scan parameters were set at 100,120 and 140 kVp tube voltages,and six radiation exposure sequences were scanned at each tube voltage:5,10,15,20,25 and 30 mGy.Measure the iodine concentration value and the CT value at the single level of 50,70 and 100 keV,and calculate the absolute error value of iodine concentration and CT value under different radiation exposure.SPSS 22.0 software single factor analysis of variance was used to compare the difference between the io-dine concentration and the absolute error of CT value under different Radiation exposure,and LSD method was used to compare the two groups.Results The absolute error of CT value of 4 g/L iodine rod with 10~30 mGy scanning at 100 keV energy level was significantly higher than that of 12 g/L and 8 g/L(P<0.05),and the absolute error of iodine concentration measurement of other iodine rods with different concentrations at different Radiation exposure had no statistical difference.Conclusions The second-generation double-layer detector spectral CT has high meas-urement stability for iodine concentration quantification and CT value accuracy under conditions of radiation dose greater than 5 mGy.
9.High levels of platelet-to-lymphocyte ratio may predict reduced risk of end stage of renal disease in Chinese patients with MPO-ANCA associated vasculitis.
Li HUANG ; Chanjuan SHEN ; Yong ZHONG ; Joshua D OOI ; Peter J EGGENHUIZEN ; Ya'ou ZHOU ; Jinbiao CHEN ; Ting WU ; Ting MENG ; Zhou XIAO ; Wei LIN ; Rong TANG ; Xiang AO ; Xiangcheng XIAO ; Qiaoling ZHOU ; Ping XIAO
Journal of Central South University(Medical Sciences) 2022;47(2):211-218
OBJECTIVES:
Platelet-to-lymphocyte ratio (PLR) has recently been investigated as a new inflammatory marker in many inflammatory diseases, including systemic lupus erythematosus and immunoglobulin A vasculitis. However, there were very few reports regarding the clinical role of PLR in patients with anti-neutrophil cytoplasmic antibody (ANCA) associated vasculitis. This study was thus undertaken to investigate the relationship between inflammatory response and disease activity in Chinese patients with myeloperoxidase-anti-neutrophil cytoplasmic antibody (MPO-ANCA) associated vasculitis. Furthermore, we evaluated whether PLR predicts the progression of end stage of renal disease (ESRD) and all-cause mortality.
METHODS:
The clinical, laboratory and pathological data, and the outcomes of MPO-ANCA associated vasculitis patients were collected. The Spearman correlation coefficient was computed to examine the association between 2 continuous variables. Cox regression analysis was used to estimate the association between PLR and ESRD or all-cause mortality.
RESULTS:
A total of 190 consecutive patients with MPO-ANCA associated vasculitis were included in this study. Baseline PLR was positively correlated with CRP (r=0.333, P<0.001) and ESR (r=0.218, P=0.003). PLR had no obvious correlation with Birmingham Vasculitis Activity Score (BVAS). Patients having PLR≥330 exhibited better cumulative renal survival rates than those having PLR<330 (P=0.017). However, there was no significant difference in the cumulative patient survival rates between patients with PLR≥330 and those with PLR<330 at diagnosis (P>0.05). In multivariate analysis, PLR is associated with the decreased risk of ESRD (P=0.038, HR=0.518, 95% CI 0.278 to 0.963). We did not find an association between PLR with all-cause mortality using multivariate analysis (HR=1.081, 95% CI 0.591 to 1.976, P=0.801).
CONCLUSIONS
PLR is positively correlated with CRP and ESR. Furthermore, PLR may independently predict the risk of ESRD.
Anti-Neutrophil Cytoplasmic Antibody-Associated Vasculitis/diagnosis*
;
Antibodies, Antineutrophil Cytoplasmic/analysis*
;
China/epidemiology*
;
Humans
;
Kidney Failure, Chronic/complications*
;
Lymphocytes
;
Peroxidase
;
Retrospective Studies
10.Research progress on intelligent assessment system for upper limb function of stroke patients.
Sujiao LI ; Kun WU ; Qiaoling MENG ; Hongliu YU
Journal of Biomedical Engineering 2022;39(3):620-626
At present, the upper limb function of stroke patients is often assessed clinically using a scale method, but this method has problems such as time-consuming, poor consistency of assessment results, and high participation of rehabilitation physicians. To overcome the shortcomings of the scale method, intelligent upper limb function assessment systems combining sensors and machine learning algorithms have become one of the hot research topics in recent years. Firstly, the commonly used clinical upper limb functional assessment methods are analyzed and summarized. Then the researches on intelligent assessment systems in recent years are reviewed, focusing on the technologies used in the data acquisition and data processing parts of intelligent assessment systems and their advantages and disadvantages. Lastly, the current challenges and future development directions of intelligent assessment systems are discussed. This review is hoped to provide valuable reference information for researchers in related fields.
Algorithms
;
Humans
;
Physical Therapy Modalities
;
Stroke/diagnosis*
;
Stroke Rehabilitation
;
Upper Extremity

Result Analysis
Print
Save
E-mail