1.Analysis of the content of five radionuclides in wild edible fungi
Zhenglin YE ; Qiang ZHOU ; Fei TUO ; Baolu YANG ; Zeshu LI ; Weihao QIN ; Shuying KONG
Chinese Journal of Radiological Health 2025;34(2):242-248
		                        		
		                        			
		                        			Objective To determine the content and distribution characteristics of the artificial radionuclide 137Cs and the natural radionuclides 210Pb, 226Ra, 228Ra, and 40K in wild edible fungi, and calculate the committed effective dose due to 137Cs and 210Pb in wild edible fungi. Methods Thirty samples of wild edible fungi were collected and their caps and stems were separated. A total of 60 samples were measured for 137Cs, 210Pb, 226Ra, 228Ra, and 40K using a BE5030 wide-energy, low-background, high-purity germanium γ spectrometer. The paired analysis of the four radionuclides 226Ra, 210Pb, 137Cs, and 40K was performed using SPSS 11.5. Results Among the 60 samples, the detection rates and dry weight specific activity ranges of 137Cs, 210Pb, 226Ra, 228Ra, and 40K were 97% and 0.62-384 Bq/kg, 73% and 6.4-159 Bq/kg, 52% and 0.7-28.8 Bq/kg, 5% and 0.43-2.18 Bq/kg and 100% and (77.4-264) × 10 Bq/kg, respectively. Conclusion Based on the analysis of the 60 samples, the detection rate of radionuclides is in the order of 40K, 137Cs, 210Pb, 226Ra, and 228Ra. In terms of the specific activity, the distribution of 40K and 226Ra in wild edible fungi in the same region is basically uniform, while the content of 210Pb and 137Cs fluctuates in different samples. Although 137Cs and 210Pb can be detected in most of the wild edible fungi, the annual committed effective dose due to ingestion of wild edible fungi is negligible.
		                        		
		                        		
		                        		
		                        	
2.Rapid Video Analysis for Contraction Synchrony of Human Induced Pluripotent Stem Cells-Derived Cardiac Tissues
Yuqing JIANG ; Mingcheng XUE ; Lu OU ; Huiquan WU ; Jianhui YANG ; Wangzihan ZHANG ; Zhuomin ZHOU ; Qiang GAO ; Bin LIN ; Weiwei KONG ; Songyue CHEN ; Daoheng SUN
Tissue Engineering and Regenerative Medicine 2025;22(2):211-224
		                        		
		                        			 BACKGROUND:
		                        			The contraction behaviors of cardiomyocytes (CMs), especially contraction synchrony, are crucial factors reflecting their maturity and response to drugs. A wider field of view helps to observe more pronounced synchrony differences, but the accompanied greater computational load, requiring more computing power or longer computational time. 
		                        		
		                        			METHODS:
		                        			We proposed a method that directly correlates variations in optical field brightness with cardiac tissue contraction status (CVB method), based on principles from physics and photometry, for rapid video analysis in wide field of view to obtain contraction parameters, such as period and contraction propagation direction and speed. 
		                        		
		                        			RESULTS:
		                        			Through video analysis of human induced pluripotent stem cell (hiPSC)-derived CMs labeled with green fluorescent protein (GFP) cultured on aligned and random nanofiber scaffolds, the CVB method was demonstrated to obtain contraction parameters and quantify the direction and speed of contraction within regions of interest (ROIs) in wide field of view. The CVB method required less computation time compared to one of the contour tracking methods, the LucasKanade (LK) optical flow method, and provided better stability and accuracy in the results. 
		                        		
		                        			CONCLUSION
		                        			This method has a smaller computational load, is less affected by motion blur and out-of-focus conditions, and provides a potential tool for accurate and rapid analysis of cardiac tissue contraction synchrony in wide field of view without the need for more powerful hardware. 
		                        		
		                        		
		                        		
		                        	
3.Rapid Video Analysis for Contraction Synchrony of Human Induced Pluripotent Stem Cells-Derived Cardiac Tissues
Yuqing JIANG ; Mingcheng XUE ; Lu OU ; Huiquan WU ; Jianhui YANG ; Wangzihan ZHANG ; Zhuomin ZHOU ; Qiang GAO ; Bin LIN ; Weiwei KONG ; Songyue CHEN ; Daoheng SUN
Tissue Engineering and Regenerative Medicine 2025;22(2):211-224
		                        		
		                        			 BACKGROUND:
		                        			The contraction behaviors of cardiomyocytes (CMs), especially contraction synchrony, are crucial factors reflecting their maturity and response to drugs. A wider field of view helps to observe more pronounced synchrony differences, but the accompanied greater computational load, requiring more computing power or longer computational time. 
		                        		
		                        			METHODS:
		                        			We proposed a method that directly correlates variations in optical field brightness with cardiac tissue contraction status (CVB method), based on principles from physics and photometry, for rapid video analysis in wide field of view to obtain contraction parameters, such as period and contraction propagation direction and speed. 
		                        		
		                        			RESULTS:
		                        			Through video analysis of human induced pluripotent stem cell (hiPSC)-derived CMs labeled with green fluorescent protein (GFP) cultured on aligned and random nanofiber scaffolds, the CVB method was demonstrated to obtain contraction parameters and quantify the direction and speed of contraction within regions of interest (ROIs) in wide field of view. The CVB method required less computation time compared to one of the contour tracking methods, the LucasKanade (LK) optical flow method, and provided better stability and accuracy in the results. 
		                        		
		                        			CONCLUSION
		                        			This method has a smaller computational load, is less affected by motion blur and out-of-focus conditions, and provides a potential tool for accurate and rapid analysis of cardiac tissue contraction synchrony in wide field of view without the need for more powerful hardware. 
		                        		
		                        		
		                        		
		                        	
4.Rapid Video Analysis for Contraction Synchrony of Human Induced Pluripotent Stem Cells-Derived Cardiac Tissues
Yuqing JIANG ; Mingcheng XUE ; Lu OU ; Huiquan WU ; Jianhui YANG ; Wangzihan ZHANG ; Zhuomin ZHOU ; Qiang GAO ; Bin LIN ; Weiwei KONG ; Songyue CHEN ; Daoheng SUN
Tissue Engineering and Regenerative Medicine 2025;22(2):211-224
		                        		
		                        			 BACKGROUND:
		                        			The contraction behaviors of cardiomyocytes (CMs), especially contraction synchrony, are crucial factors reflecting their maturity and response to drugs. A wider field of view helps to observe more pronounced synchrony differences, but the accompanied greater computational load, requiring more computing power or longer computational time. 
		                        		
		                        			METHODS:
		                        			We proposed a method that directly correlates variations in optical field brightness with cardiac tissue contraction status (CVB method), based on principles from physics and photometry, for rapid video analysis in wide field of view to obtain contraction parameters, such as period and contraction propagation direction and speed. 
		                        		
		                        			RESULTS:
		                        			Through video analysis of human induced pluripotent stem cell (hiPSC)-derived CMs labeled with green fluorescent protein (GFP) cultured on aligned and random nanofiber scaffolds, the CVB method was demonstrated to obtain contraction parameters and quantify the direction and speed of contraction within regions of interest (ROIs) in wide field of view. The CVB method required less computation time compared to one of the contour tracking methods, the LucasKanade (LK) optical flow method, and provided better stability and accuracy in the results. 
		                        		
		                        			CONCLUSION
		                        			This method has a smaller computational load, is less affected by motion blur and out-of-focus conditions, and provides a potential tool for accurate and rapid analysis of cardiac tissue contraction synchrony in wide field of view without the need for more powerful hardware. 
		                        		
		                        		
		                        		
		                        	
5.Rapid Video Analysis for Contraction Synchrony of Human Induced Pluripotent Stem Cells-Derived Cardiac Tissues
Yuqing JIANG ; Mingcheng XUE ; Lu OU ; Huiquan WU ; Jianhui YANG ; Wangzihan ZHANG ; Zhuomin ZHOU ; Qiang GAO ; Bin LIN ; Weiwei KONG ; Songyue CHEN ; Daoheng SUN
Tissue Engineering and Regenerative Medicine 2025;22(2):211-224
		                        		
		                        			 BACKGROUND:
		                        			The contraction behaviors of cardiomyocytes (CMs), especially contraction synchrony, are crucial factors reflecting their maturity and response to drugs. A wider field of view helps to observe more pronounced synchrony differences, but the accompanied greater computational load, requiring more computing power or longer computational time. 
		                        		
		                        			METHODS:
		                        			We proposed a method that directly correlates variations in optical field brightness with cardiac tissue contraction status (CVB method), based on principles from physics and photometry, for rapid video analysis in wide field of view to obtain contraction parameters, such as period and contraction propagation direction and speed. 
		                        		
		                        			RESULTS:
		                        			Through video analysis of human induced pluripotent stem cell (hiPSC)-derived CMs labeled with green fluorescent protein (GFP) cultured on aligned and random nanofiber scaffolds, the CVB method was demonstrated to obtain contraction parameters and quantify the direction and speed of contraction within regions of interest (ROIs) in wide field of view. The CVB method required less computation time compared to one of the contour tracking methods, the LucasKanade (LK) optical flow method, and provided better stability and accuracy in the results. 
		                        		
		                        			CONCLUSION
		                        			This method has a smaller computational load, is less affected by motion blur and out-of-focus conditions, and provides a potential tool for accurate and rapid analysis of cardiac tissue contraction synchrony in wide field of view without the need for more powerful hardware. 
		                        		
		                        		
		                        		
		                        	
6.Rapid Video Analysis for Contraction Synchrony of Human Induced Pluripotent Stem Cells-Derived Cardiac Tissues
Yuqing JIANG ; Mingcheng XUE ; Lu OU ; Huiquan WU ; Jianhui YANG ; Wangzihan ZHANG ; Zhuomin ZHOU ; Qiang GAO ; Bin LIN ; Weiwei KONG ; Songyue CHEN ; Daoheng SUN
Tissue Engineering and Regenerative Medicine 2025;22(2):211-224
		                        		
		                        			 BACKGROUND:
		                        			The contraction behaviors of cardiomyocytes (CMs), especially contraction synchrony, are crucial factors reflecting their maturity and response to drugs. A wider field of view helps to observe more pronounced synchrony differences, but the accompanied greater computational load, requiring more computing power or longer computational time. 
		                        		
		                        			METHODS:
		                        			We proposed a method that directly correlates variations in optical field brightness with cardiac tissue contraction status (CVB method), based on principles from physics and photometry, for rapid video analysis in wide field of view to obtain contraction parameters, such as period and contraction propagation direction and speed. 
		                        		
		                        			RESULTS:
		                        			Through video analysis of human induced pluripotent stem cell (hiPSC)-derived CMs labeled with green fluorescent protein (GFP) cultured on aligned and random nanofiber scaffolds, the CVB method was demonstrated to obtain contraction parameters and quantify the direction and speed of contraction within regions of interest (ROIs) in wide field of view. The CVB method required less computation time compared to one of the contour tracking methods, the LucasKanade (LK) optical flow method, and provided better stability and accuracy in the results. 
		                        		
		                        			CONCLUSION
		                        			This method has a smaller computational load, is less affected by motion blur and out-of-focus conditions, and provides a potential tool for accurate and rapid analysis of cardiac tissue contraction synchrony in wide field of view without the need for more powerful hardware. 
		                        		
		                        		
		                        		
		                        	
7.Interpretation of Gamma-ray spectrometry method for the determination of radionuclides in environmental and biological samples
Fei TUO ; Qiang ZHOU ; Baolu YANG ; Zeshu LI ; Weihao QIN ; S' ; huying KONG
Chinese Journal of Radiological Health 2024;33(2):111-115
		                        		
		                        			Abstract
		                        			As a rapid analytical method for both the types and activities of γ radionuclides, the γ-ray spectrometry method is
widely used in the measurement of γ radionuclides in environmental and biological samples. The Gamma-ray Spectrometry
Method for the Determination of Radionuclides in Environmental and Biological Samples (GB/T 16145—2022)was implemented  on  July  1,  2023,  replacing  the Determination of Radionuclides in Soil by Gamma Spectrometry (GB/T
11743—2013), Determination of Radionuclides in Water by Gamma Spectrometry (GB/T 16140—2018), Gamma Spectrometry Method of Analyzing Radionuclides in Biological Samples (GB/T 16145—2020), and Determination of Radionuclides
in Air by Gamma Spectrometry (WS/T 184—2017). The background of the revised standard, the content and basis of the
main revisions, and some issues that need to be discussed are briefly explained in this paper, in order to provide a useful reference for the detection of radioactivity in soil, water, biological, and air samples, as well as samples of similar matrices.
		                        		
		                        		
		                        		
		                        	
8.Application of lower extremity arterial thrombosis with Rotarex mechanical thrombectomy system
Qiang ZHANG ; Guochao YOU ; Huajing XU ; Xiangxiang KONG ; Dianbin YANG ; Yan LIU
Journal of Practical Radiology 2024;40(3):460-463
		                        		
		                        			
		                        			Objective To investigate the application of Rotarex mechanical thrombectomy system in lower extremity arterial thrombosis and to evaluate its clinical efficacy.Methods The clinical data of 61 patients(71 limbs,35 cases in acute phase,21 cases in subacute phase and 5 cases in chronic phase)with lower extremity arterial thrombosis treated with Rotarex were analyzed retro-spectively.Distal protective device was used in patients with poor distal artery outflow.High pressure saline was used during the pro-cedure and stent was used in patients with flow-limiting dissection.Catheter aspiration was performed in patients with distal artery embo-lization.Anticoagulant therapy was used in patients with thromboembolism and dual antiplatelet therapy was used in patients with in-situ thrombosis.Postoperative follow-up was performed with color Doppler ultrasound or computed tomography angiography(CTA)at 1 month,3 months and 6 months.Results Fifty-nine cases were treated with 6F Rotarex catheters and 2 cases were treated with 8F Rotarex catheters.Distal protective device was used in 10 cases,balloon dilation was performed in 49 cases and stent was used in 5 cases.Catheter aspiration was performed in 10 cases.Vessel rupture occurred in 4 cases,among whom 3 cases were successfully treated with the method of balloon compression and 1 case was treated with covered stent.Severe adverse events occurred in 4 cases and perioperative toe amputation was performed in 7 cases.Follow-up time was 3 to 6 months(mean 4.9 months).Lower extremity ischemic event occurred in 1 case at 6th month follow-up and was treated with stent.No other lower extremity ischemic events occurred in the course of follow-up.Conclusion For the treatment of lower extremity arterial thrombosis,Rotarex mechanical thrombectomy sys-tem has the advantages of minimally invasion,rapid and high efficiency.Combined with the therapy of catheter aspiration and stent place-ment,vascular patency can be further maintained and the lower extremity ischemic symptoms can be quickly relieved.
		                        		
		                        		
		                        		
		                        	
9.Analysis of food sample composition for gamma spectrometry-based sourceless efficiency simulation
Lingnan KONG ; Baolu YANG ; Jing ZHANG ; Qiang ZHOU
Chinese Journal of Radiological Medicine and Protection 2024;44(2):140-146
		                        		
		                        			
		                        			Objective:To recommend reference composition for sourceless efficiency calibration of food gamma spectrometry by analyzing the composition of common foods based on a combination of sourceless efficiency calibration and active validation.Methods:Thirty common types of food samples in countrywide monitoring of radioactively contaminated foods were analyzed to statistically determine the reference composition of grains and vegetables. Combined with the parameters provided for white quinoa standard source, LabSOCS was applied to carry out the simulation of sourceless efficiency for its different compositions, and to calculate its measured activity, and analyzing its relative deviation to the those given in the certificate.Results:The analytical result of these 30 types of food samples showed that the five elements C, H, O, N and S accounted for 77.0%-93.7% of the food composition, being the main component of these samples. By applying white quinoa′s components and grain-based reference components to the simulation of the sourceless efficiency of white quinoa standard sources, the relative deviations of activity calculations to their certificated activities were in the range of 0.37%-5.86% and 0.38%-5.87% in absolute value, respectively.Conclusions:The white quinoa′s composition and the grain reference composition were applied to the sourceless efficiency simulation of the white quinoa standard source, and the relative deviation of the calculated measured activity to the activity of the standard source certificate was basically identical, so that if the gamma spectrometry-based sourceless efficiency simulation is used to measure the unknown composition of the food samples and it is inconvenient to carry out the analysis of the food samples′ compositions, especially in the case of emergency, it can be referred to the use of the reference compositions obtained in the present study.
		                        		
		                        		
		                        		
		                        	
10.National bloodstream infection bacterial resistance surveillance report (2022) : Gram-negative bacteria
Zhiying LIU ; Yunbo CHEN ; Jinru JI ; Chaoqun YING ; Qing YANG ; Haishen KONG ; Haifeng MAO ; Hui DING ; Pengpeng TIAN ; Jiangqin SONG ; Yongyun LIU ; Jiliang WANG ; Yan JIN ; Yuanyuan DAI ; Yizheng ZHOU ; Yan GENG ; Fenghong CHEN ; Lu WANG ; Yanyan LI ; Dan LIU ; Peng ZHANG ; Junmin CAO ; Xiaoyan LI ; Dijing SONG ; Xinhua QIANG ; Yanhong LI ; Qiuying ZHANG ; Guolin LIAO ; Ying HUANG ; Baohua ZHANG ; Liang GUO ; Aiyun LI ; Haiquan KANG ; Donghong HUANG ; Sijin MAN ; Zhuo LI ; Youdong YIN ; Kunpeng LIANG ; Haixin DONG ; Donghua LIU ; Hongyun XU ; Yinqiao DONG ; Rong XU ; Lin ZHENG ; Shuyan HU ; Jian LI ; Qiang LIU ; Liang LUAN ; Jilu SHEN ; Lixia ZHANG ; Bo QUAN ; Xiaoping YAN ; Xiaoyan QI ; Dengyan QIAO ; Weiping LIU ; Xiusan XIA ; Ling MENG ; Jinhua LIANG ; Ping SHEN ; Yonghong XIAO
Chinese Journal of Clinical Infectious Diseases 2024;17(1):42-57
		                        		
		                        			
		                        			Objective:To report the results of national surveillance on the distribution and antimicrobial resistance profile of clinical Gram-negative bacteria isolates from bloodstream infections in China in 2022.Methods:The clinical isolates of Gram-negative bacteria from blood cultures in member hospitals of national bloodstream infection Bacterial Resistant Investigation Collaborative System(BRICS)were collected during January 2022 to December 2022. Antibiotic susceptibility tests were conducted by agar dilution or broth dilution methods recommended by Clinical and Laboratory Standards Institute(CLSI). WHONET 5.6 and SPSS 25.0 software were used to analyze the data.Results:During the study period,9 035 strains of Gram-negative bacteria were collected from 51 hospitals,of which 7 895(87.4%)were Enterobacteriaceae and 1 140(12.6%)were non-fermenting bacteria. The top 5 bacterial species were Escherichia coli( n=4 510,49.9%), Klebsiella pneumoniae( n=2 340,25.9%), Pseudomonas aeruginosa( n=534,5.9%), Acinetobacter baumannii complex( n=405,4.5%)and Enterobacter cloacae( n=327,3.6%). The ESBLs-producing rates in Escherichia coli, Klebsiella pneumoniae and Proteus spp. were 47.1%(2 095/4 452),21.0%(427/2 033)and 41.1%(58/141),respectively. The prevalence of carbapenem-resistant Escherichia coli(CREC)and carbapenem-resistant Klebsiella pneumoniae(CRKP)were 1.3%(58/4 510)and 13.1%(307/2 340);62.1%(36/58)and 9.8%(30/307)of CREC and CRKP were resistant to ceftazidime/avibactam combination,respectively. The prevalence of carbapenem-resistant Acinetobacter baumannii(CRAB)complex was 59.5%(241/405),while less than 5% of Acinetobacter baumannii complex was resistant to tigecycline and polymyxin B. The prevalence of carbapenem-resistant Pseudomonas aeruginosa(CRPA)was 18.4%(98/534). There were differences in the composition ratio of Gram-negative bacteria in bloodstream infections and the prevalence of main Gram-negative bacteria resistance among different regions,with statistically significant differences in the prevalence of CRKP and CRPA( χ2=20.489 and 20.252, P<0.001). The prevalence of CREC,CRKP,CRPA,CRAB,ESBLs-producing Escherichia coli and Klebsiella pneumoniae were higher in provinicial hospitals than those in municipal hospitals( χ2=11.953,81.183,10.404,5.915,12.415 and 6.459, P<0.01 or <0.05),while the prevalence of CRPA was higher in economically developed regions(per capita GDP ≥ 92 059 Yuan)than that in economically less-developed regions(per capita GDP <92 059 Yuan)( χ2=6.240, P=0.012). Conclusions:The proportion of Gram-negative bacteria in bloodstream infections shows an increasing trend,and Escherichia coli is ranked in the top,while the trend of CRKP decreases continuously with time. Decreasing trends are noted in ESBLs-producing Escherichia coli and Klebsiella pneumoniae. Low prevalence of carbapenem resistance in Escherichia coli and high prevalence in CRAB complex have been observed. The composition ratio and antibacterial spectrum of bloodstream infections in different regions of China are slightly different,and the proportion of main drug resistant bacteria in provincial hospitals is higher than those in municipal hospitals.
		                        		
		                        		
		                        		
		                        	
            
Result Analysis
Print
Save
E-mail