1.Etiological characteristics and molecular evolution of the first mpox case in Huai’an City of Jiangsu Province
Pengfei YANG ; Fang HE ; Qingli YAN ; Heyuan GENG ; Tong GAO ; Qiang GAO ; Chenglong XIONG ; Haiyan PENG
Chinese Journal of Schistosomiasis Control 2025;37(1):85-92
Objective To analyze the virus subtypes, molecular evolutional and molecular transmission network features of the first confirmed mpox case in Huai’an City, Jiangsu Province, so as to provide insights into understanding of the transmission and evolution dynamics of mpox virus and formulation of the mpox control strategy in the city. Methods Genomic DNA was extracted from swabs of the first confirmed mpox case’s skin lesions in Huai’an City, and the amplicon sequencing library was constructed using the hypersensitive mpox virus whole-genome capture kit. High-throughput sequencing was performed using the GridION X5 nanopore sequencer on the Nanopore sequencing platform, and single nucleotide polymorphism (SNP) analysis of mpox virus genome sequences was performed following sequence assembly. In addition, phylogenetic analysis, genetic genealogy and molecular traceability analysis were performed. Results The virus whole genome sequence of the first confirmed mpox case was successfully obtained by high-throughput sequencing, with a full length of 197 182 bp, and was named hMpxV/China/JS-HA01/2023, which belonged to the clade IIb (West African clade) lineage B.1.3. Compared with the mpox virus reference sequence MPXV-M5312_HM12_Rivers-001 (GenBank accession number: NC_063383), the genome sequence of the Huai’an virus isolate carried 86 SNPs, including 40 SNPs in the coding region as non-synonymous mutations and 73 SNPs as nucleotide mutations caused by APOBEC3 (APOBEC3). Of the 97 mpox virus gene sequences, 79 sequences were included in the molecular network (81.44%), and the threshold of the genetic distance accessed to the network was 0.35/105. There were two large molecular transmission clusters and one scattered cluster in the molecular transmission network of the mpox virus, andthehMpxV/China/JS-HA01/2023 sequence was located in the large cluster. The 97 gene sequences formed 92 haplotypes, including three shared haplotypes Hap_4, Hap_6 and Hap_38, and an exclusive haplotype Hap_1 of hMpxV/China/JS-HA01/2023 generated from mutation of the exclusive haplotype Hap_43, while the exclusive haplotype Hap_43 was generated from mutation of the shared haplotype Hap_38. Conclusions The whole genome sequence of the mpox virus isolated from the first confirmed mpox case in Huai’an City has been successfully obtained, and the molecular evolutionary and molecular transmission network characteristics of the virus have been preliminarily understood.
2.Practice innovation in pharmaceutical management for infusion safety in hospitalized patients
Jie CHEN ; Man YOU ; Pengfei CAO ; Wenfeng TAI ; Lu MENG ; Hong ZHANG ; Guanghong HE
China Pharmacy 2025;36(10):1238-1242
OBJECTIVE To establish a pharmaceutical management model for infusion safety in hospitalized inpatients and ensure the safety of drug use. METHODS Our hospital established the standardized management process for infusion scheme, formulated rules for compatibility contraindications in drug combinations. In the form of embedded hospital official account, the infusion scheme and medication guidance WeChat developed by pharmacists are pushed to the mobile phone of inpatients, providing electronic medication guidance services for patients, and forming a pharmaceutical management model for infusion safety of inpatients. RESULTS Our hospital provided a total of 45 291 inpatients with pharmaceutical services including the formulation of individualized infusion scheme and WeChat push infusion scheme and medication guidance as of December 2023. After the implementation of the management model, the intervention rate of pharmacists on the compatibility contraindications in drug combination of long-term medical orders for inpatients increased from 18.25% before implementation to 90.58% (P<0.01), and the satisfaction rate of inpatients increased from 87.50% to 94.50% (P<0.05). CONCLUSIONS The pharmaceutical management model for infusion safety of hospitalized patients integrates pharmaceutical services throughout the entire process of intravenous medication treatment. Pharmacists can participate in the management of infusion usage while providing qualified finished infusion products, achieving closed-loop management of pharmaceutical services, improving the hospital’s pharmaceutical service capabilities and patient satisfaction, and providing guarantees for the safety and effectiveness of patient medication.
3.Advances in diffuse optical technology lenses for myopia control
Kun HE ; Bingxin PAN ; Suyun YANG ; Zhiyang HE ; Mengting ZHENG ; Meiling SHU ; Pengfei JIANG ; Shan XU ; Pengfei TIAN
International Eye Science 2025;25(9):1476-1483
Recent years have witnessed significant advancements in myopia control research through the application of diffuse optical technology(DOT)spectacle lenses. Myopia has emerged as a global public health challenge, affecting nearly half of the world's population, with childhood and adolescent myopia rates continuing to rise. DOT lenses represent an innovative myopia control intervention based on retinal contrast signal theory. These lenses incorporate micro-light scattering dots distributed across the lens surface to reduce retinal imaging contrast and modulate the influence of visual input on axial elongation, thereby slowing myopia progression. The core mechanism operates through refractive index differences between the lens substrate(1.53)and scattering dots(1.50), which generate optical scattering effects. This design maintains clear vision through a central 5 mm optical zone while effectively reducing contrast signal intensity in the peripheral retina. Large-scale randomized controlled trials, including the CYPRESS study, have demonstrated significant myopia control efficacy in children aged 6-10 years: 12-month follow-up data revealed a 74% reduction in myopia progression and a 50% reduction in axial elongation, with sustained safety and visual quality maintained over 4-year long-term follow-up. However, several aspects of DOT technology remain contentious and require further clinical validation, including its applicability across different age groups, optimal scattering dot density configurations, combined application effects with other myopia control methods, and long-term visual adaptation during extended use. This review systematically examines the theoretical foundations, design characteristics, clinical application progress, and future development directions of DOT technology, providing scientific evidence for clinical myopia prevention and control strategy formulation.
4.Early outcomes of anterior segment parameters in patients with high myopia after implantable collamer lens V4c implantation
Bingxin PAN ; Jie WU ; Pengfei JIANG ; Shan XU ; Kun HE
International Eye Science 2024;24(3):491-494
AIM: To study the early outcomes of anterior segment parameters after implantation of an implantable collamer lens with a central hole(ICL V4c)in patients with high myopia.METHODS:A total of 82 cases(160 eyes)with high myopia, including 42 males(82 eyes)and 40 females(78 eyes), aged 26.0±4.6(21 to 37)years, who underwent ICL V4c implantation at our institution from February 2019 to September 2022 and were followed up for 1 a, were included. The general characteristics of the anterior segment of the eye were measured preoperatively: spherical equivalent, mean horizontal corneal curvature, white-to-white(WTW), and axial length(AL); intraocular pressure(IOP), endothelial cell density(ECD), central anterior chamber depth(CACD), anterior chamber volume(ACV)and anterior chamber angle(ACA)were measured preoperatively and at 1 d, 1 wk, 1, 3 and 6 mo postoperatively. Furthermore, the distance from the centre of the posterior surface of the ICL V4c optical zone to the anterior surface of the lens(vault)was measured at 1 d, 1 wk, 1, 6 mo, and 1 a after surgery.RESULTS: The mean preoperative spherical equivalent of the patients was -7.56±2.55 D, mean horizontal corneal curvature was 42.89±1.47 D, WTW was 11.64±0.37 mm, and AL was 26.64±0.93 mm. The baseline IOP was 15.97±2.13 mmHg, and the differences in IOP at each time point after ICL V4c implantation compared to preoperative were not statistically significant(F=0.875, P=0.504); ECD was 2 989.30±140.78 cells/mm2 at baseline, and ECD at 6 mo after ICL V4c implantation was not statistically significant compared with preoperative ECD(t=1.475, P=0.142); CACD was 3.19±0.21 mm at baseline, and ACV was 210.30±27.7 mm3, and CACD and ACV were significantly lower than preoperative at all postoperative time points(F=111.10, 288.38, all P<0.001). The baseline ACA was 35.44°±11.27°, and the ACA at each time point after ICL V4c implantation was significantly lower than preoperatively(F=21.23, P<0.001). The vault was 665.32±184.03 μm at 1 d postoperatively, and continued to be significantly reduced at 1 wk, 1, 6 mo, and 1 a postoperatively compared with 1 d(F=52.10, P<0.001). However, it remained stable at 6 mo and 1 a postoperatively, and the difference was not statistically significant compared with vault at 1 mo postoperatively(P>0.05).CONCLUSION: ICL V4c has certain safety and efficiency in 1 a postoperative follow-up, and the parameters of the anterior segment of the eye stabilized in the early period.
5.Biomechanical analysis of the bones in a rat model of osteoporosis based on the combination of disease and syndrome
Chubin LIN ; Xingpeng HE ; Yuhui QIU ; Wenjin WU ; Yu CHANG ; Tao YE ; Pengfei LI ; Jian YANG
Chinese Journal of Tissue Engineering Research 2024;28(23):3636-3641
BACKGROUND:Kidney deficiency is the main pathogenesis of osteoporosis.To study the relationship between the two major syndrome types of kidney deficiency,Kidney-Yang deficiency and Kidney-Yin deficiency,is beneficial for the development of clinical diagnosis and treatments based on the combination of disease and syndrome. OBJECTIVE:To evaluate the biomechanical differences of the rat femurs with Kidney-Yang deficiency and Kidney-Yin deficiency caused by Yougui pills,and to demonstrate the scientific efficacy of medication based on the combination of disease and syndrome in osteoporosis from a biomechanical perspective. METHODS:The bilateral ovaries of 60 female Sprague-Dawley rats were surgically removed to establish an ovariectomized osteoporosis model.At 10 weeks after modeling,all the rats were randomly divided into a Kidney-Yang deficiency group(n=30)and a Kidney-Yin deficiency group(n=30).Rats with Kidney-Yang deficiency were given gluteal intramuscular injection of hydrocortisone,while rats with Kidney-Yin deficiency were orally administered with thyroid tablet suspension,once a day,for 14 consecutive days.After successful modeling,20 rats in each group were given a suspension of Yougui pills by gavage once a day for 12 consecutive weeks and the remaining 10 rats were used as the control group without intervention.After gavage,the microstructural parameters of the bone were measured using Micro-CT scanning.Three-point bending,finite element simulation,femoral head compression,and surface indentation distribution experiments of the femurs were performed on a mechanical testing machine. RESULTS AND CONCLUSION:Micro-CT revealed that the femoral bone density,bone volume fraction,bone surface density,trabecular number,and trabecular separation were improved in the Kidney-Yin deficiency+Yougui pills group compared with the Kidney-Yin deficiency group(P<0.05);the femoral bone volume fraction,bone surface density,trabecular number,and trabecular thickness were improved in the Kidney-Yang deficiency+Yougui pills group compared with the Kidney-Yang deficiency group(P<0.05).The three-point bending experiment showed that the femur elastic modulus,maximum bending strength and bending fracture strength were decreased(P<0.05)and toughness was increased(P<0.05)in the Kidney-Yang deficiency+Yougui pills group compared with the Kidney-Yang deficiency group.Finite element simulation showed that Yougui pills could significantly improve the bending resistance of the femurs in the Kidney-Yang deficiency group,but had no significant effect on the Kidney-Yin deficiency group.The femoral head compression experiments showed that Yougui pills could enhance the ability of the femoral head to resist deformation in the Kidney-Yang deficiency group,but there was no significant difference in the effect of Yougui pills on the surface properties of the femoral head in the Kidney-Yin deficiency group and the Kidney-Yang deficiency group.To conclude,Yougui pills can significantly enhance the biomechanical properties of the osteoporotic bones with Kidney-Yang deficiency,but have no significant effect on the osteoporotic bone with Kidney-Yin deficiency.
6.Updates and amendments of standards for Chinese medicinal materials and decoction pieces characteristics in the Chinese Pharmacopoeia
LI Zhengguo ; ZHANG Hongwei ; WANG Haibo ; HE Yi ; TU Pengfei
Drug Standards of China 2024;25(1):041-047
According to the relevant requirements of the Chinese Pharmacopoeia and relevant reports, this article briefly introduces the basic principles, research ideas, and precautions for the revision of the “characteristics” standards of Chinese medicinal materials and decoction pieces. In recent years, enterprises and social media reported that the characteristics of Chinese medicinal materials in the market did not fully comply with the characteristics specified in the Chinese Pharmacopoeia. Therefore, this article explored the variation in the characteristics of Chinese medicinal materials and decoction pieces and its main reasons, scientific and reasonable revision of the “characteristics” of Chinese medicinal materials and decoction pieces, the new methods for identifying properties, as well as the issues that need to be noted in revising the characteristics of Chinese medicinal materials and decoction pieces, which provided reference for the revision of the “characteristics” standards of Chinese medicinal materials and decoction pieces.
7.Penile protection with a self-developed flexible sleeve penile protection device after circumcision: a prospective randomized controlled trial
Pengfei TUO ; Kewei CHEN ; Xinchen LIU ; Guodong ZHU ; Huixing HE ; Tao CAI ; Yuxuan LI ; Xun ZHAO ; Liyuan GE ; Shudong ZHANG ; Lulin MA ; Wei GUO ; Zhuo LIU
Journal of Modern Urology 2024;29(4):363-367
【Objective】 To investigate the protective effects of aflexible sleeve penile protection device on reducing postoperative pain and wound edema in patients after circumcision. 【Methods】 A total of 54 patients who underwent circumcision at Yan’an Branch of Peking University Third Hospital during Feb.1 and May 31, 2023 were enrolled.The patients were randomly divided into the experimental group and control group, with 27 patients in either groups.Patients in the experimental group were treated with a flexible sleeve penis protection device after surgery, and patients in the control group were treated with traditional gauze bandage after surgery.Postoperative pain, wound edema and complications were compared between the two groups. 【Results】 In terms of pain, the visual analogue scale of the experimental group was significantly lower at 6 hours [(1.7±0.9) vs.(3.3±1.9), P<0.001] and 2 days [(2.0±1.3) vs.(3.3±1.3), P<0.001] after surgery than that of the control group, but there were no statistically significant differences between the two groups on the 4th and 7th postoperative days (P>0.05).In terms of edema, the edema score of the experimental group was significantly lower than that of the control group on the 2nd postoperative day [(2.0±1.0) vs.(4.0±0.8), P<0.001] , the 4th postoperative day [(1.5±1.2) vs.(2.6±0.9), P<0.001] , and the 7th postoperative day [(0.9±1.3) vs.(2.3±1.5), P<0.001] .There was no statistically significant difference in the incidence of complications between the two groups (P>0.05). 【Conclusion】 The flexible sleeve penile protection device has significant effects of reducing early postoperative pain and reducing edema in patients undergoing circumcision.
8.Evaluation of safety of early enteral nutrition in patients with severe intra-abdominal infection and intestinal fistulas
Tian XIE ; Chen CHEN ; Dongliang YANG ; Wenyue WANG ; Fen CHEN ; Yining HE ; Pengfei WANG ; Yousheng LI
Chinese Journal of Gastrointestinal Surgery 2024;27(3):241-246
Objective:To evaluate the safety of early enteral nutrition (EEN) support in patients with severe intra-abdominal infection and intestinal fistulas.Methods:This was a retrospective cohort study. We collected relevant clinical data of 204 patients with severe intra-abdominal infection and intestinal fistulas who had been managed in the No. 1 Department of General Surgery, Shanghai Ninth People's Hospital, Shanghai Jiaotong University between 1 January 2017 and 1 January 2020. The patients were allocated to EEN or delayed enteral nutrition (DEN) groups depending on whether enteral nutrition had been instituted within 48 hours of admission to the intensive care unit. The primary outcome was 180-day mortality. Other outcomes included rates of intraperitoneal hemorrhage, septic shock, open abdominal cavity, bloodstream infection, mechanical ventilation, and continuous renal replacement therapy. Risk factors for mortality were analyzed by logistic regression.Results:There were no significant differences in hematological data or other baseline characteristics between the two groups at the time of admission to the intensive care unit (all P>0.05). However, septic shock (31.2% [15/48] vs. 15.4% [24/156], χ 2=4.99, P=0.025), continuous renal replacement therapy (27.1% [13/48] versus 9.0% [14/156], χ 2=8.96, P=0.003), and 180-day mortality (31.2% [15/48] vs. 7.7% [12/156], χ 2=15.75, P<0.001) were significantly more frequent in the EEN than the DEN group (all P<0.05). Multivariate regression analysis showed that older age (OR=1.082, 95%CI:1.027-1.139, P=0.003), worse Acute Physiology and Chronic Health Evaluation (APACHE) II scores (OR=1.189, 95%CI: 1.037-1.363, P=0.013), higher C-reactive protein (OR=1.013, 95%CI:1.004-1.023, P=0.007) and EEN (OR=8.844, 95%CI:1.809- 43.240, P=0.007) were independent risk factors for death in patients with severe intra-abdominal infection and intestinal fistulas. Conclusion:EEN may lead to adverse events and increase mortality in patients with both enterocutaneous fistulas and severe abdominal infection. EEN should be implemented with caution in such patients.
9.Development Status of Integrated PET/MR Products
Chinese Journal of Medical Instrumentation 2024;48(4):401-406
Integrated PET/MR is one of cutting-edge technologies in functional and molecular imaging.A review of the current development status of integrated PET/MR products can provide inspiration and promote the development of related fields.This study introduced the technical characteristics and research and development difficulties of integrated PET/MR products from both hardware and software aspects,summarized the publication of English and Chinese papers related to the clinical application of PET/MR products from 2008 to 2022,analysed the differences and current status of clinical application of integrated PET/MR products at home and abroad,and pointed out the development status and direction of integrated PET/MR products in China.Finally,the development of integrated PET/MR products was discussed in terms of technology,clinical application prospects,and market strategies.
10.Research advance of clinical application of X-ray Flash-RT equipment
Ruo TANG ; Xiaozhong HE ; Pengfei ZHU ; Zhuo ZHANG ; Ziping HUANG ; Shuqing LIAO ; Tao WEI ; Liu YANG ; Jinshui SHI
China Medical Equipment 2024;21(1):24-28
The protection effect of flash-radiotherapy(Flash-RT)with super-high dose on normal tissue has obtained wide attention in therapeutic radiology since it was found in 2014 year.The increasing research demand of Flash-RT with super-high dose-rate proposed new challenge for the existing radiotherapy equipment.Based on the demands of FLASH-RT research and clinical application,this review analyzed the proposed new requirement of Flash-RT for equipment,and introduce current scientific facilities with the experimental ability of X-ray FLASH-RT,as well as the situation of the specialized FLASH-RT equipment which were developing.The research of Flash-RT mechanism need the existing equipment with high-energy X-ray source develop toward high power,while the clinical application of Flash-RT demand these transient high-power devices should possess a series of radiotherapy techniques such as multi angle irradiation,conformal radiotherapy and others.Currently,China's X-ray FLASH-RT research is at the forefront of the world,which is expected to achieve the first breakthrough of high-end medical equipment in the X-ray Flash RT field.

Result Analysis
Print
Save
E-mail