1.Olecranon osteotomy approach for Dubberley type Ⅲ coronal fractures of the distal humerus.
Kai LIU ; Jan-Wei HU ; Yun-Zhou CHEN ; Ru-Guo SHANG ; Yong-Xin YU
China Journal of Orthopaedics and Traumatology 2023;36(2):156-160
OBJECTIVE:
To retrospectively analyze the clinical efficacy of olecranon osteotomy approach in the treatment of Dubberley type Ⅲ coronal fractures of the distal humerus and summarize the treatment experience.
METHODS:
From January 2016 to June 2020, 17 patients (5 males and 12 females) with Dubberley type Ⅲ coronal fractures of the distal humerus were treated by olecranon osteotomy approach. The age ranged from 37 to78 years old with an average of (58.5±12.9) years old. According to Dubberley classification, there were 5 cases of type Ⅲ A and 12 cases of type Ⅲ B. The curative effect was evaluated using the Borberg-Morrey elbow function score. The flexion, extension and rotation range of motion of the elbow joint, complications and postoperative imaging evaluation were recorded.
RESULTS:
All the 17 patients got bony union. The follow-up time ranged from 12 to 33 months with an average of (15.6±5.6) months. There was 1 case of ischemic necrosis of capitulum humeri, 2 cases of traumatic arthritis and 1 case of heterotopic ossification, 1 case of malunion of fracture. The range of motion was (114.80±19.50) °. The Broberg-Morrey score was 85.3±8.2, excellent in 5 cases, good in 9 cases, fair in 3 cases and poor in 0 case.
CONCLUSION
Through olecranon osteotomy approach, the articular surface of distal humerus could be fully exposed, and the operation is convenient. Anatomical reduction and rigid fixation of the articular surface of distal humerus are the key factors for the succesful outcome.
Male
;
Female
;
Humans
;
Adult
;
Olecranon Process/surgery*
;
Elbow Joint/surgery*
;
Humeral Fractures/surgery*
;
Retrospective Studies
;
Fracture Fixation, Internal/methods*
;
Humerus/surgery*
;
Treatment Outcome
;
Range of Motion, Articular
2.Comparison of the efficacy of three types of Kirschner wire tension bands for ulnar olecranal fracture.
Jia-Ru CHEN ; Zhe-Fei MOU ; Jun-Ju ZHENG
China Journal of Orthopaedics and Traumatology 2023;36(7):607-613
OBJECTIVE:
To compare the clinical effect of three types of Kirschner wire tension band for olecranon fracture.
METHODS:
The clinical data of 64 patients with olecranon fracture treated by Kirschner wire tension band fixation from March 2016 to May 2020 were retrospectively analyzed. Among them, 19 patients were treated with intramedullary K-wires fixation(group A) including 8 males and 11 females with an average of (48.2±18.3) years old, 3 patients were typeⅠ, and 16 patients were typeⅡ according to Mayo classification;20 patients were treated with transcortical K-wires fixation (group B) including 13 males and 7 females with an average of (43.5±20.4) years old, 3 patients were typeⅠand 17 patients were typeⅡ according to Mayo classification;25 patients were treated with perforated Kirschner wire(group C) including 15 males and 10 females with an average of (55.2±17.5) years old, 4 patients were typeⅠand 21 patients were typeⅡ according to Mayo classification. The operative time, intraoperative blood loss, times of Intraoperative fluoroscopy, fracture healing time and complications of 3 groups were compared. At the final follow-up, elbow function was assessed using the Mayo Elbow Function Scale.
RESULTS:
There were differences in operative time, intraoperative fluoroscopy times, postoperative VAS and soft tissue irritation among the three groups(P<0.05). The operative time, intraoperative fluoroscopy times in group A and C was better than that in group B. The postoperative VAS score, skin irritability in group C was better than that of group B. The difference was statistically significant on Mayo elbow function score at the final follow-up among three groups(P<0.05), the scores of group A and C were higher than that of group B.
CONCLUSION
Compared with transcortical K-wires screw fixation, both intramedullary K-wires screw fixation and perforated Kirschner wire fixation, which can significantly reduce the occurrence of soft tissue irritation, reduce surgical complications and shorten the operation time.
Male
;
Female
;
Humans
;
Adult
;
Middle Aged
;
Aged
;
Young Adult
;
Bone Wires
;
Retrospective Studies
;
Fracture Fixation, Internal
;
Ulna Fractures/surgery*
;
Olecranon Process/surgery*
;
Inflammation
;
Treatment Outcome
3.Long-term results of olecranon fractures treated using the XS nail® system.
Leonard HÖCHTL-LEE ; Matthias SPALTEHOLZ ; Tim Friedrich RAVEN ; Arash MOGHADDAM ; Wilhelm FRIEDL
Chinese Journal of Traumatology 2022;25(6):336-344
PURPOSE:
Olecranon fractures are particularly vulnerable to distraction and subsequent fracture dislocation due to the high tensile forces. Surgical treatment aims at reducing the fracture and restoring the anatomical joint surface condition, as well as neutralizing the strain inhibiting fracture healing. The XS nail® (Intercus GmbH, Bad Blankenberg, Germany), an intramedullary implant exerting compression across the entire fracture surface, unlike plates, leaves a minimal extra-cortical profile, and can be secured with threaded locking wires, thereby retaining the anatomical reduction without displacement or steps within the articular surface, which was often found in tension band wiring. After encouraging initial results, the long-term outcome was assessed.
METHODS:
This retrospective study evaluated the long-term outcome of patients surgically treated at our trauma center between January 2002 and December 2005 using the XS nail®. Patients over the age of 18 years eligible for the study must have undergone surgery for isolated, recent (less than 14 days) traumatic olecranon fractures, without concomitant injuries to the ipsilateral elbow and forearm. Further exclusion criteria were pseudarthrosis, re-fractures and osteotomy for distal humerus surgery, as well as polytraumatized patients unable to aid in their own recovery. Data were retrospectively gathered by standardised questionnaire and patient records, as well as surgery and anesthesiology reports. Data analysis was performed using Microsoft Office Excel® 2016.
RESULTS:
There were 32 patients, 13 males (mean age 49.0 years) and 19 females (mean age 68.9 years) with 11 Schatzkers type D, 7 each type A and C, 5 type B and 2 type E at an average of 55.2 months, all showing complete consolidation. Of them, 6 patients had a loss of range of motion with more than 10° in the sagittal plane, and only 1 patient exceeded 10° reduction of supination. Twenty-five patients reported being pain-free under all circumstances, and all but 2 patients (93.75%) had returned to their previous activity level. The average disabilities of the arm, shoulder and hand score was 21.15 (range 0-88.3), and the overall Mayo elbow performance index was 91.87, without complications, such as wound infection, neurovascular impairment or premature hardware removal.
CONCLUSION
Using the XS nail® system, all fracture types can be successfully treated and the rate of complications was lower than that treated by standard methods published in current literature. An excellent functional outcome, high range of motion as well as good retention of reduction without soft tissue irritation makes this a very suitable implant for fractures subject to tension.
Male
;
Female
;
Humans
;
Adult
;
Middle Aged
;
Aged
;
Olecranon Process/injuries*
;
Retrospective Studies
;
Ulna Fractures/surgery*
;
Bone Wires
;
Fracture Fixation, Internal/methods*
;
Fractures, Bone
;
Range of Motion, Articular
;
Treatment Outcome
;
Elbow Injuries
4.Clinical observation of double mini locking plate in the treatment of olecranon fracture.
Fu-de JIAO ; Qing WANG ; Bo XUE ; Peng-Han YE ; Yong LU ; Jing-Wei ZHANG
China Journal of Orthopaedics and Traumatology 2021;34(6):554-558
OBJECTIVE:
To investigate the clinical effect of double mini-locking plates in the treatment of ulna olecranon fractures.
METHODS:
From March 2017 to May 2020, 19 patients with olecranon fractures were treated with double mini locking plates, including 12 males and 7 females, aged from 20 to 75 years old with an average of (40.50±7.62) years old;10 patients had the injuries on the left side and 9 patients on the right side. All the 19 patients were fresh closed fractures without ulnar coronoid process fracture, elbow dislocation and other injuries. The fracture healing time and complications were recorded, and the clinical efficacy was evaluated by Mayo elbow performance score (MEPS) before operation and 12 months after operation.
RESULTS:
All the 19 patientswas followed up, and the duration ranged from 12 to 17 months with an average of (13.51±3.17) months. Postoperative follow-up showed all fractures healed. Fracture healing time ranged from 2 to 6 months, with an average of(3.77±1.24) months. There was no internal fixation fracture, screw loosening, infection, internal fixation irritation, heterotopic ossification, elbow stiffness and other complications occurred. The MEPS score of affected elbow at 12 months after operation was 91.26±3.87, which was significantly different from that before operation 56.18±9.56 (
CONCLUSION
It is a reliable fixation method to treat olecranon fracture with double mini locking plate. The incision lengh is small and the fracture fixation is reliable. Elbow joint function exercise can be performed early after operation. Postoperative internal fixation has less skin irritation and satisfactory elbow joint function recovery.
Adult
;
Aged
;
Bone Plates
;
Elbow Joint
;
Female
;
Fracture Fixation, Internal
;
Humans
;
Male
;
Middle Aged
;
Olecranon Process
;
Treatment Outcome
;
Ulna Fractures
;
Young Adult
5.Olecranon osteotomy vs. triceps-sparing for open reduction and internal fixation in treatment of distal humerus intercondylar fracture: a systematic review and meta-analysis.
Shuai LU ; Ye-Jun ZHA ; Mao-Qi GONG ; Chen CHEN ; Wei-Tong SUN ; Ke-Han HUA ; Xie-Yuan JIANG
Chinese Medical Journal 2021;134(4):390-397
BACKGROUND:
The open reduction and internal fixation (ORIF) was a standard treatment approach for fracture at distal humerus intercondylar, whereas the optimal way before ORIF remains inconclusive. We, therefore, performed a systematic review and meta-analysis to assess the efficacy and safety of olecranon osteotomy vs. triceps-sparing approach for patients with distal humerus intercondylar fracture.
METHODS:
The electronic searches were systematically performed in PubMed, EmBase, Cochrane library, and Chinese National Knowledge Infrastructure from initial inception till December 2019. The primary endpoint was the incidence of excellent/good elbow function, and the secondary endpoints included Mayo elbow performance score, duration of operation, blood loss, and complications.
RESULTS:
Nine studies involving a total of 637 patients were selected for meta-analysis. There were no significant differences between olecranon osteotomy and triceps-sparing approach for the incidence of excellent/good elbow function (odds ratio [OR]: 1.37; 95% confidence interval [CI]: 0.69-2.75; P = 0.371), Mayo elbow performance score (weight mean difference [WMD]: 0.17; 95% CI: -2.56 to 2.89; P = 0.904), duration of operation (WMD: 4.04; 95% CI: -28.60 to 36.69; P = 0.808), blood loss (WMD: 33.61; 95% CI: -18.35 to 85.58; P = 0.205), and complications (OR: 1.93; 95% CI: 0.49-7.60; P = 0.349). Sensitivity analyses found olecranon osteotomy might be associated with higher incidence of excellent/good elbow function, longer duration of operation, greater blood loss, and higher incidence of complications as compared with triceps-sparing approach.
CONCLUSIONS
This study found olecranon osteotomy did not yield additional benefit on the incidence of excellent/good elbow function, while the duration of operation, blood loss, and complications in patients treated with olecranon osteotomy might be inferior than triceps-sparing approach.
Elbow Joint/surgery*
;
Fracture Fixation, Internal
;
Humans
;
Humeral Fractures/surgery*
;
Humerus
;
Olecranon Process/surgery*
;
Osteotomy
;
Range of Motion, Articular
;
Treatment Outcome
6.Choice of internal fixation selection and clinical effect of olecranon fracture.
Jun ZHANG ; Ding-Shuang CHEN ; Dong-Xu LIU ; Feng LI
China Journal of Orthopaedics and Traumatology 2020;33(7):602-608
OBJECTIVE:
To compare clinical effects of common Kirschner wire, anatomical plate and perforated Kirschner wire in treating olecranon fracture.
METHODS:
From March 2014 to May 2017, clinical data of 79 patients with olecranon fracture treated with different internal fixation was retrospectively analyzed. Among them, 26 patients treated with common Kirschner wire (group A), including 19 males and 7 females aged from 23 to 51 years old with an average of (37.2±9.6) years old;11 patients were typeⅠ, and 15 patients were typeⅡ according to Mayo classification. Twenty eight patients were treated with olecroanon anatomical plate internal fixation, including 16 males and 12 females aged from 25 to 52 years old with an average of (36.6±8.9) years old;10 patientswere typeⅠ and 18 patients were typeⅡ according to Mayo classification. Twenty five patients were treated with perforated Kirschner wire, including 13 males and 12 females aged from 26 to 51 years old with an average of (38.2±9.2) years old;9 patients were typeⅠand 16 patients were typeⅡ according to Mayo classification. Operation time, intraoperatve blood loss, fracture healing time and postoperative complications among three groups were compared; VAS score at 1 week after operation was used to evaluate pain relief, Broberg-Morrey function score of elbow joint at the final follow up was applied to evaluate clinical effect.
RESULTS:
Seventy nine patients were followed up from 13 to 23 months with an average of (18.3±4.5) months. Operation time, intraoperatve blood loss, fracture healing time in group A were (82.9±19.7) min, (113.5±32.3) ml, (4.2±0.6) months respectively;in group B were(101.2±24.5) min, (150.2±39.5) ml, (4.6±0.8) months respectively;in group C were (83.3±18.7) min, (119.3±34.3) ml, (4.1±0.5) months respectively. Operation time, intraoperatve blood loss, fracture healing time in group A and group C were better than that of group B(<0.05). Five patients in group A occurred ineffective internal fixation, other groups did not occurred;9 patients in group A occurred skin irritability, 3 patients in group B and no patient occurred in group C; there were statistical differences in complications among three groups (<0.05). There were no differences in VAS score at 1 week after operation and Broberg-Morrey function score of elbow joint at the final follow-up among three groups (>0.05).
CONCLUSION
Common Kirschner wire has more complications; anatomical plate has greater surgical trauma and long fracture healing time;while perforated Kirschner wire was not only benefit for fracture union with less trauma, but also could reducing the incidence of postoperative complications, and it is the appropriate method for patients with olecranon fracture.
Adult
;
Bone Plates
;
Female
;
Fracture Fixation, Internal
;
Humans
;
Male
;
Middle Aged
;
Olecranon Process
;
Retrospective Studies
;
Treatment Outcome
;
Ulna Fractures
;
Young Adult
7.Synchronization of Synovial Chondromatosis and Mycobacterium intracellurae Infection in Olecranon Bursitis: A Case Report
Dong Hyun KIM ; Seunggi MIN ; Hyun Joo LEE ; Hee June KIM ; Hoseok LEE ; Jong Pil YOON
Clinics in Shoulder and Elbow 2019;22(1):46-49
A 73-year-old woman presented with a recurrent cystic mass around her left olecranon. She had a history of 8 steroid injections due to elbow pain beginning 3 years ago and twice had undergone aspiration of olecranon bursitis that developed two months prior to presentation. She had been taking medications for hypertension and diabetes with no pertinent past history. On magnetic resonance imaging (MRI), there were multiple nodules in the olecranon bursa, which were isointense to muscle on T1-weighted images and hyperintense to muscle on T2-weighted images. Our initial diagnosis was synovial chondromatosis. On bursoscopy, masses of gray-white colored nodules were observed in the bursa. Finally, synovial chondromatosis and non-tuberculous mycobacterial infection were concurrently diagnosed. In conclusion, uncalcified synovial chondromatosis and rice bodies can have similar visual and MRI characteristics; therefore, we suggest that clinicians should be aware of the possibility of other infections in cases of this type.
Aged
;
Bursitis
;
Chondromatosis, Synovial
;
Diagnosis
;
Elbow
;
Female
;
Humans
;
Hypertension
;
Magnetic Resonance Imaging
;
Mycobacterium
;
Nontuberculous Mycobacteria
;
Olecranon Process
;
Synovitis
;
Tuberculosis
8.Clinical observation of olecranon sled for the treatment for olecranal fracture.
Ye-Jun ZHA ; Xie-Yuan JIANG ; Mao-Qi GONG
China Journal of Orthopaedics and Traumatology 2019;32(4):339-345
OBJECTIVE:
To explore clinical effect of olecranon sled in treating olecranal fracture.
METHODS:
Four patients with olecranal fracture treated by olecranon sled in March 2017, including 2 males and 2 females, age of 40, 46, 47, 72 years old, 3 patients on the left side and 1 patient on the right side. All patients were caused by falling down. Fracture were transverse, oblique and slightly compressive articular surface fracture. The time from injury to operation ranged from 1 to 3 days. Operative time, blood loss, complications and flexion and extension of elbow joint, and function of forearm were observed, VAS score was used to evaluate relieve degree of pain, and Mayo score was applied to assess recovery of elbow function.
RESULTS:
Four patients were followed up until September 2018. Operative time ranged from 40 to 60 min, blood loss was for 20 to 40 ml, and no complications occurred. All fracture were healed at 4 months after operation. Elbow flexion was for 140° to 150°, extension of elbow was from 0° and extend to 10°, activity of flexion and extension ranged from 140 ° to 160°, MEPS score was 100. No pain occurred during doing activity, and VAS score was 0.
CONCLUSIONS
Low-profile design and integrated design of olecranon sled could avoid irritation of tension band and plate, and it is a simple and ideal internal fixation method for simple and mildly comminuted olecranon fracture, which is not suitable for severely comminuted olecranon fracture.
Adult
;
Aged
;
Bone Plates
;
Elbow Joint
;
Female
;
Fracture Fixation, Internal
;
Fractures, Comminuted
;
Humans
;
Male
;
Middle Aged
;
Olecranon Process
;
Range of Motion, Articular
;
Treatment Outcome
;
Ulna Fractures
9.Biomechanical Comparison of Fixed- versus Variable-Angle Locking Screws for Distal Humerus Comminuted Fractures
Ali NOURBAKHSH ; Adam G HIRSCHFELD ; Sravan DHULIPALA ; William HUTTON ; Timothy GANEY ; Luis LOZADA ; Daniel SCHLATTERER ; Gary Mark LOURIE
Clinics in Orthopedic Surgery 2019;11(3):302-308
BACKGROUND: To compare the stability of fixed- versus variable-angle locking constructs for the comminuted distal humerus fracture (AO/OTA 13-A3). METHODS: Eight pairs of complete humeri harvested from eight fresh frozen cadavers were used for the study. We fixed the intact humeri using 2.7-mm/3.5-mm locking VA-LCP stainless steel distal humerus posterolateral (nine-hole) and medial (seven-hole) plates. An oscillating saw was used to cut a 1-cm gap above the olecranon fossa. The specimens were loaded in axial mode with the rate of 1 mm per 10 seconds to failure, and stress-strain curves were compared in each pair. The mode of failure was recorded as well as the load needed for 2- and 4-mm displacement at the lateral end of the gap. RESULTS: The stiffness of the constructs, based on the slope of the stress-strain curve, did not show any difference between the fixed- versus variable-angle constructs. Likewise, there was no difference between the force needed for 2- or 4-mm displacement at the lateral gap between the fixed- and variable-angle constructs. The mode of failure was bending of both plates in all specimens and screw pull-out in four specimen pairs in addition to the plate bending. CONCLUSIONS: Our results did not show any difference in the biomechanical stability of the fixed- versus variable-angle constructs. There was not any screw breakage or failure of the plate-screw interface.
Bone Screws
;
Cadaver
;
Fracture Fixation
;
Fractures, Comminuted
;
Humerus
;
Olecranon Process
;
Stainless Steel
10.Surgical Treatment Strategy for Distal Humerus Intra-articular Fractures
Journal of the Korean Shoulder and Elbow Society 2019;22(2):113-117
Treating distal humerus fractures, especially those involving intra-articular lesions, is complex and often technically demanding. Although there still exist many controversial issues, the goal of treatment is to establish anatomical stable fixation by restoring the two columns and the articular surface. Universally, a posterior midline incision is applied, and the approach varies according to the further management of the triceps or olecranon. Evidence supports dual plate fixation as the optimal fixation method, and debates regarding appropriate plating configuration are still ongoing. As multiple clinical studies comparing results of parallel and perpendicular plate fixation have shown no actual difference, it is important to place the plates according to the fracture configuration.
Fracture Fixation
;
Humerus
;
Intra-Articular Fractures
;
Methods
;
Olecranon Process

Result Analysis
Print
Save
E-mail