1.Study on mandibular movement trajectory and virtual occlusal pre-adjustment under light and heavy bite force.
Jia Yi ZHU ; Jun Jie WANG ; Yu Xuan WANG ; Jing Wen YANG ; Ting JIANG
Chinese Journal of Stomatology 2023;58(1):50-56
Objective: To investigate the influence of light and heavy bite force on the mandibular movement trajectories, and the influence of bite force on virtual occlusal pre-adjustment of digital full crown. Methods: From October 2021 to March 2022, 10 postgraduate volunteers (3 males and 7 females, aged 22-26 years) were recruited from Peking University School and Hospital of Stomatology. Maxillary and mandibular digital models of the participants were obtained by intraoral scanning. Jaw relations were digitally transferred under heavy bite force and mandibular movement trajectories under light and heavy bite force were recorded by jaw motion analyser. Three mandibular markers were chosen, namely the mesial proximal contact point of the central incisor (incisal point) and the mesial buccal cusp tips of the bilateral first molars. The three-dimensional displacements of the markers under two kinds of bite force in the intercuspal position (ICP), the sagittal projection of the three-dimensional displacements in the protrusive edge-to-edge position, and the coronal projection of the three-dimensional displacements in the lateral edge-to-edge position of upper and lower posterior teeth were measured. Single-sample t-test was used to compare the three-dimensional displacements and the corresponding sagittal projection and coronal projection with 0, respectively. The left maxillary central incisor and left mandibular first molar were virtually prepared by the reverse engineering software. Then dental design software was used to design digital full crown using the copy method. The mandibular movement trajectories under light and heavy bite force were separately used to guide virtual occlusal pre-adjustment. The three-dimensional deviations (mean deviations and root mean square) between the lingual surface of the left maxillary central incisor or the occlusal surface of the left mandibular first molar and that of the natural tooth before preparation were calculated (light bite force group and heavy bite force group), and the differences between the two groups were compared by the paired t-test. Results: Under the two kinds of bite force, the three-dimensional displacements of the markers in the ICP were (0.217±0.135), (0.210±0.133) and (0.237±0.101) mm, respectively; the sagittal projection of the three-dimensional displacements of the markers in the protrusive edge-to-edge position were (0.204±0.133), (0.288±0.148) and (0.292±0.136) mm, respectively; the coronal projection of the three-dimensional displacements of the mesial buccal cusp tips of the bilateral first molars in the lateral edge-to-edge position were (0.254±0.140) and (0.295±0.190) mm, respectively. The differences between the above displacements and 0 were statistically significant (P<0.05). The results of occlusal pre-adjustment showed that the mean deviations of the lingual surface of the left maxillary central incisor in the light and heavy bite force groups were (0.215±0.036) and (0.195±0.041) mm (t=3.95, P=0.004), respectively. The mean deviations of the occlusal surface of the left mandibular first molar were (0.144±0.084) and (0.100±0.096) mm (t=0.84, P=0.036), respectively. Conclusions: Both the light and heavy bite force have an influence on the mandibular movement trajectories. Virtual occlusal pre-adjustment of prostheses with mandibular movement trajectories under heavy bite force can obtain morphology of lingual or occlusal surfaces closer to the natural teeth before preparation.
Male
;
Female
;
Humans
;
Bite Force
;
Tooth
;
Mandible
;
Molar
;
Occlusal Adjustment
2.A comparative study based on the mandibular movement track and the movement parameters of the virtual articulator in simulating occlusal adjustment.
Liya MA ; Jiarui CHAO ; Fei LIU ; Jiansong MEI ; Jiefei SHEN
West China Journal of Stomatology 2023;41(3):254-259
OBJECTIVES:
This study aimed to compare the effects of virtual adjustment on occlusal interferences in mandibular posterior single crown and three-unit bridge restorations by using the mandibular movement track and the movement parameters of a virtual articulator.
METHODS:
Twenty-two participants were recruited. Digital casts of the maxillary and mandibular arches were obtained using an intraoral scanner, and the jaw registration system was used to record the data of the mandibular movement track and the movement parameters of the articulator. Four kinds of restorations with 0.3 mm occlusal interferences were designed with dental design software. In particular, single crowns were designed for teeth 44 and 46, whereas three-unit bridges were designed for teeth 44-46 and 45-47, and the corresponding natural teeth were virtually extracted. Virtual adjustment of the restorations was performed using two dynamic occlusal recordings, namely, the mandibular movement track and the movement parameters of the virtual articulator. A reverse-engineering software was used to measure the root-mean-square of the three-dimensional deviation of the occlusal surfaces between natural teeth and the adjusted restorations. The differences between the two methods of virtual-occlusion adjustment were compared and analyzed.
RESULTS:
For the same group of restorations, the three-dimensional deviation of the mandibular movement track group were lower than those of the virtual articulator group, and the differences were statistically significant (P<0.05). For the four groups of restorations adjusted by the same method, the three-dimensional deviation of the 46-tooth single crown was the largest and the smallest three-dimensional deviation was that of the 44-tooth single crown. Statistical differences existed between the 44-tooth single crown and the other groups (P<0.05).
CONCLUSIONS
For the occlusal design of posterior single crown and three-unit bridge, the mandibular movement track could be a more effective approach to virtual occlusal adjustment than the movement parameters of the virtual articulator.
Humans
;
Mouth, Edentulous
;
Occlusal Adjustment
;
Jaw Relation Record
;
Dental Articulators
;
Software
3.Interpretation of the European Federation of Periodontology S3 level clinical practice guideline for treatment of stage Ⅳ periodontitis.
Bin CHEN ; Yan Fang LI ; Ri Xin CHEN ; Min WANG ; Yue LI ; Hua NIE ; Zuo Min WANG ; Fuhua YAN
Chinese Journal of Stomatology 2022;57(12):1195-1201
The S3 level clinical practice guideline for the treatment of stage Ⅳperiodontitis, developed by the European Federation of Periodontology, was published in April 22, 2022 (DOI: 10.1111/jcpe.13639). According to the severity and complexity, stage Ⅳ periodontitis was grouped into four case types, and comprehensive treatment plans were formulated correspondingly in the guideline, including tooth splinting, occlusal adjustment, orthodontic therapy, restorative therapy, and personalized supportive periodontal care as well. The aim of present work is to intensively interpret the key points of the guideline and help the clinicians to understand this guideline better, in order to improve the treatment level of stage Ⅳ periodontitis in China.
Humans
;
Periodontitis/therapy*
;
Periodontics
;
Tooth
;
Occlusal Adjustment
;
China
4.Method and accuracy of determining the jaw position of repositioning splint with the aid of digital technique.
Shuo Bo FANG ; Guang Ju YANG ; Yan Feng KANG ; Yu Chun SUN ; Qiu Fei XIE
Journal of Peking University(Health Sciences) 2020;53(1):76-82
OBJECTIVE:
To establish the workflow of determining the jaw position of repositioning splint with the aid of digital technique, and to evaluate the accuracy of this workflow and compare the accuracy of raising different vertical dimensions in vitro.
METHODS:
A volunteer was recruited. The data of full-arch scans, cone beam computed tomography (CBCT) image and ultrasonic jaw motion tracking of the volunteer were acquired. The full-arch scans were merged with the CBCT image, which were then matched to the jaw motion tracking reference system. The jaw position of repositioning splint was determined when the anterior teeth opening was 3 mm and the condyle was in centric relation of the fossa in the sagittal plane. A digital repositioning splint was designed in the software based on virtual articulator and fabricated with additive manufacturing technique. After the splint was tried in, another CBCT image was taken and a qualitative analysis was conducted to compare the position of condyle between these two CBCT images. In the in vitro study, standard dental plaster casts with resin ball markers attached to the base were mounted onto a fully adjustable articulator in the intercuspal position. The dental casts were scanned by an extraoral scanner to establish digital models. The ultrasonic jaw motion tracking device was used to obtain simulated jaw movements on the articulator, which was repeated for three times. The digital models and data of jaw movements were merged in one coordination with the aid of bite forks. The jaw position of repositioning splint was determined by adjusting data of jaw movements, each of which was used to determine three vertical jaw positions 4 mm, 5 mm, and 6 mm with the horizontal jaw position of protrusion 2 mm. The virtual articulators with differently adjusted jaw movements were applied in designing repositioning splints, and the final repositioning splints and virtual jaw relationships were exported in STL format. Then the repositioning splints were fabricated with additive manufacturing technique and tried in plaster casts on the mechanical articulator, which were scanned and the jaw relationships on the mechanical articulator were exported later. The virtual jaw relationships and scanned jaw relationships were registered according to lower models and displacement of upper models was calculated. Ball markers were fit to acquire the coordinates of centers and absolute difference values of centers along three coordinating axes X, Y, and Z were calculated. One-way analysis of variance was conducted using SPSS 18.0 software to compare deviations of the three different vertical jaw relationships in two-side test and the significance level was 0.05.
RESULTS:
With the aid of multi-source data fusion and individualized jaw motion, the clinical workflow of determining jaw position of repositioning splint was preliminarily established. The designed jaw position was realized on the right and the condyle was more inferior than the designed position on the left. Both displacement of the upper models and absolute difference values of centers showed no significant differences (P>0.05) in different vertical jaw dimensions. The displacement of the upper models was (0.25±0.04) mm. The absolute difference values of centers along the three coordinating axes X, Y, and Z were respectively (0.08±0.01) mm, (0.30±0.02) mm, and (0.21±0.04) mm.
CONCLUSION
A novel method of determining the jaw position of repositioning splint with the aid of digital technique is established. It is proved to be feasible by try-in after multi-data fusion, computer-aided design and computer-aided manufacturing. As is shown in vitro, it is accurate to apply this method in adjusting jaw position. Further clinical trial will be designed to evaluate its clinical effect.
Computer-Aided Design
;
Cone-Beam Computed Tomography
;
Dental Articulators
;
Humans
;
Jaw Relation Record
;
Occlusal Splints
;
Software
;
Splints
5.The effects of surface grinding and polishing on the phase transformation and flexural strength of zirconia
Ji Young LEE ; Geun Won JANG ; In Im PARK ; Yu Ri HEO ; Mee Kyoung SON
The Journal of Advanced Prosthodontics 2019;11(1):1-6
PURPOSE: The purpose of this in vitro study was to evaluate the effect of surface grinding and polishing procedures using high speed zirconia diamond burs with different grit sizes on the phase transformation and flexural strength of zirconia.
Dental Instruments
;
Diamond
;
In Vitro Techniques
;
Occlusal Adjustment
6.A CAD/CAM-based strategy for concurrent endodontic and restorative treatment
Patricia Maria ESCOBAR ; Anil KISHEN ; Fabiane Carneiro LOPES ; Caroline Cristina BORGES ; Eugenio Gabriel KEGLER ; Manoel Damião SOUSA-NETO
Restorative Dentistry & Endodontics 2019;44(3):e27-
This case report describes a technique in which endodontic treatment and permanent indirect restoration were completed in the same clinical appointment with the aid of a computer-aided design/computer-aided manufacturing (CAD/CAM) system. Two patients were diagnosed with irreversible pulpitis of the mandibular first molar. After access preparation, root canals were located, irrigation was performed until bleeding ceased, and the coronal tooth structure was prepared for indirect restoration. Then, utilizing an interim 3-mm build-up of the endodontic access cavity, a hemi-arch digital scan was performed with an intraoral scanner. Subsequent to digital scanning, restoration design was performed simultaneously with the endodontic procedure. The root canals were shaped using the Race system under irrigation with 2.5% sodium hypochlorite followed by root canal filling. The pulp chamber was subsequently filled with a 3-mm-thick composite resin restoration mimicking the interim build-up previously utilized to facilitate block milling in the CAD/CAM system. Clinical try-in of the permanent onlay restoration was followed by acid etching, application of a 5th generation adhesive, and cementation of the indirect restoration. Once the restoration was cemented, rubber dam isolation was removed, followed by occlusal adjustment and polishing. After 2 years of follow-up, the restorations were esthetically and functionally satisfactory, without complications.
Adhesives
;
Cementation
;
Computer-Aided Design
;
Continental Population Groups
;
Dental Pulp Cavity
;
Endodontics
;
Follow-Up Studies
;
Hemorrhage
;
Humans
;
Inlays
;
Molar
;
Occlusal Adjustment
;
Pulpitis
;
Rubber Dams
;
Sodium Hypochlorite
;
Tooth
7.Simulated occlusal adjustments and their effects on zirconia and antagonist artificial enamel
Najm Mohsen ALFRISANY ; Babak SHOKATI ; Laura Eva TAM ; Grace Mendonca DE SOUZA
The Journal of Advanced Prosthodontics 2019;11(3):162-168
PURPOSE: The aim of this study was to evaluate the effect of occlusal adjustments on the surface roughness of yttria-tetragonal zirconia polycrystal (Y-TZP) and wear of opposing artificial enamel.
Dental Enamel
;
Dental Porcelain
;
Mastication
;
Occlusal Adjustment
8.Masticatory muscle tendon-aponeurosis hyperplasia accompanied by limited mouth opening
Journal of the Korean Association of Oral and Maxillofacial Surgeons 2019;45(4):174-179
Patients with masticatory muscle tendon-aponeurosis hyperplasia (MMTAH) experience limited mouth opening due to restricted muscle extension. Hyperplastic aponeurosis and tendons lead to the restriction of muscle extension. The criteria for the diagnosis of MMTAH are limited mouth opening that progresses very slowly from adolescence, intraoral palpation reveals a hard cord-like structure along the overhang of the anterior border of the masseter muscle on maximum mouth opening, and a square mandible. Conservative treatment, including pharmacotherapy, occlusal splint and physical therapy are ineffective. The standard therapy is surgical treatment, such as anterior partial aponeurectomy of the masseter muscle and coronoidectomy. The long-term results are very satisfying.
Adolescent
;
Diagnosis
;
Drug Therapy
;
Humans
;
Hyperplasia
;
Mandible
;
Masseter Muscle
;
Masticatory Muscles
;
Mouth
;
Occlusal Splints
;
Palpation
;
Tendons
9.Preliminary clinical application of complete digital workflow of design and manufacturing occlusal splint for sleep bruxism.
Shi Min WANG ; Zheng LI ; Guan Bo WANG ; Hong Qiang YE ; Yun Song LIU ; Dai TONG ; Wen Hui GAO ; Yong Sheng ZHOU
Journal of Peking University(Health Sciences) 2019;51(1):105-110
OBJECTIVE:
To establish a complete workflow of digital design and manufacturing occlusal splint for sleep bruxism, which can be preliminarily applied in clinical use, thus observe the clinical efficacy.
METHODS:
Twenty-four patients with sleep bruxism were recruited in the study and randomly divided into two groups by using random number tables. Digital-occlusal-splint (experimental group) treatment plan and traditional-occlusal-splint (control-group) treatment plan were carried out for each group, respectively. For experimental group, digital models of patients' both dental arches and the occlusion relationship after elevation were captured using an intraoral scanner. The occlusal splint was carried out by computer aided design/computer aided manufacturing (CAD/CAM), including splint designing and milling. For control group, the traditional soft occlusal splint was fabricated by vacuum laminator. The two kinds of occlusal splints were tried in the patients from each group, and the occlusal contacts were tested respectively by T-scan analysis system, which recorded the changes of occlusal indicators in the two groups. The retention, appearance and occlusal comfort degree were evaluated by the two groups of patients. Mann-Whitney test was performed with IBM SPSS 20.0 software, and bilateral test was performed. P<0.05 was considered to be statistically significant.
RESULTS:
The complete workflow of digital design and manufacturing occlusal splint was successfully established. During the clinical use, there was no statistical difference in the retention evaluation of two kinds of occlusal splints between the two groups of patients (Z=-0.538, P=0.590). The appearance score (Z=2.038, P=0.042) and the occlusal comfort score (Z=-2.579, P=0.010) of the experimental group were higher than those of the control group, with statistically significant differences. The T-scan analysis results showed that only the second molar on both sides of the traditional occlusal splint had occlusal contact in intercupsal position, while the digital occlusal splint had stable and bilaterally balanced contact between the maxillary and mandibular teeth. Furthermore, the occlusal force was uniformly distributed in the experimental group.
CONCLUSION
The complete workflow of digital occlusal splint improves the occlusal design, greatly simplifies and optimizes the traditional process of making occlusal splint. This new method is resource-saving and environmental-friendly, and it is able to serve patients more conveniently and efficiently.
Dental Arch
;
Dental Occlusion
;
Humans
;
Occlusal Splints
;
Sleep Bruxism
;
Workflow
10.The effect of various polishing systems on surface roughness and phase transformation of monolithic zirconia
Ipek CAGLAR ; Sabit Melih ATES ; Zeynep YESIL DUYMUS
The Journal of Advanced Prosthodontics 2018;10(2):132-137
PURPOSE: The purpose of this study was to evaluate and compare three polishing systems on the surface roughness and phase transformation of monolithic zirconia. MATERIALS AND METHODS: 100 disk shaped specimens (10 mm diameter, 3 mm thickness) were fabricated from monolithic zirconia blocks. 20 specimens were left as a control group and remaining specimens were grinded by diamond bur to simulate the occlusal adjustments. Grinded specimens were randomly divided into 4 groups: group G (no polishing), group M (Meisinger, zirconia polishing kit), group E (EVE Diacera, zirconia polishing kit), and group P (EVE Diapol, porcelain polishing kit). Surface roughness was measured with profilometer and surface topography was observed with SEM. XRD analysis was performed to investigate the phase transformation. Statistical analysis was performed with one-way ANOVA and Tukey's post hoc tests at a significance level of P=.05. RESULTS: All polishing groups showed a smoother surface than group G. Among 3 polishing systems, group M and group E exhibited a smoother surface than the group P. However, no significant differences were observed between group M and group E (P>.05). Grinding and polishing did not cause phase transformations in zirconia specimens. CONCLUSION: Zirconia polishing systems created a smoother surface on zirconia than the porcelain polishing system. Phase transformation did not occur during the polishing procedure.
Dental Instruments
;
Dental Porcelain
;
Occlusal Adjustment

Result Analysis
Print
Save
E-mail