1.Optimal Parameters for Virtual Mono-Energetic Imaging of Liver Solid Lesions.
Acta Academiae Medicinae Sinicae 2023;45(2):280-284
Objective To explore the optimal parameters for virtual mono-energetic imaging of liver solid lesions. Methods A retrospective analysis was performed on 60 patients undergoing contrast-enhanced spectral CT of the abdomen.The iodine concentration values of hepatic arterial phase images and the CT values of different mono-energetic images were measured.The correlation coefficient and coefficient of variation were calculated. Results The average correlation coefficients between iodine concentrations and CT values of hepatic solid lesion images at 40,45,50,55,60,65,and 70 keV were 0.996,0.995,0.993,0.989,0.978,0.970,and 0.961,respectively.The correlation coefficients at 40(P=0.007),45(P=0.022),50 keV (P=0.035)were higher than that at 55 keV,and the correlation coefficients at 40 keV(P=0.134) and 45 keV(P=0.368) had no significant differences from that at 50 keV.The coefficients of variation of the CT values at 40,45,and 50 keV were 0.146,0.154,and 0.163,respectively. Conclusion The energy of 40 keV is optimal for virtual mono-energetic imaging of liver solid lesions in the late arterial phase,which is helpful for the diagnosis of liver diseases.
Humans
;
Tomography, X-Ray Computed
;
Retrospective Studies
;
Abdomen
;
Iodine
;
Liver/diagnostic imaging*
;
Signal-To-Noise Ratio
;
Radiographic Image Interpretation, Computer-Assisted/methods*
2.Quality of Images Reconstructed by Deep Learning Reconstruction Algorithm for Head and Neck CT Angiography at 100 kVp.
Xiao-Ping LU ; Yun WANG ; Yu CHEN ; Yan-Ling WANG ; Min XU ; Zheng-Yu JIN
Acta Academiae Medicinae Sinicae 2023;45(3):416-421
Objective To evaluate the impact of deep learning reconstruction algorithm on the image quality of head and neck CT angiography (CTA) at 100 kVp. Methods CT scanning was performed at 100 kVp for the 37 patients who underwent head and neck CTA in PUMC Hospital from March to April in 2021.Four sets of images were reconstructed by three-dimensional adaptive iterative dose reduction (AIDR 3D) and advanced intelligent Clear-IQ engine (AiCE) (low,medium,and high intensity algorithms),respectively.The average CT value,standard deviation (SD),signal-to-noise ratio (SNR),and contrast-to-noise ratio (CNR) of the region of interest in the transverse section image were calculated.Furthermore,the four sets of sagittal maximum intensity projection images of the anterior cerebral artery were scored (1 point:poor,5 points:excellent). Results The SNR and CNR showed differences in the images reconstructed by AiCE (low,medium,and high intensity) and AIDR 3D (all P<0.01).The quality scores of the image reconstructed by AiCE (low,medium,and high intensity) and AIDR 3D were 4.78±0.41,4.92±0.27,4.97±0.16,and 3.92±0.27,respectively,which showed statistically significant differences (all P<0.001). Conclusion AiCE outperformed AIDR 3D in reconstructing the images of head and neck CTA at 100 kVp,being capable of improving image quality and applicable in clinical examinations.
Humans
;
Computed Tomography Angiography/methods*
;
Radiation Dosage
;
Deep Learning
;
Radiographic Image Interpretation, Computer-Assisted/methods*
;
Signal-To-Noise Ratio
;
Algorithms
3.Noise Exposure and Stress Hormone Levels:A Review.
Xiao-Jun XU ; Pei-Yi QIAN ; Yun LIU ; Hai-Yan WANG ; Lei YANG
Acta Academiae Medicinae Sinicae 2023;45(3):519-525
Noise is one of the most common environmental hazards to which people are exposed,and the exposure to noise can cause not only hearing but also non-hearing damage.Although noise under safety limits may not affect the auditory system,it can cause changes in stress hormone levels,which is harmful to health.However,the current studies about the impact of noise on health mainly focus on the auditory system,and little is known about the relationship between noise and stress hormone levels.Therefore,this paper reviews the studies involving noise exposure and stress hormone levels,aiming to provide ideas for strengthening the prevention and control of noise hazards.
Humans
;
Hearing
;
Noise/adverse effects*
;
Hormones
4.Research on phase modulation to enhance the feature of high-frequency steady-state asymmetric visual evoked potentials.
Wei ZHAO ; Lichao XU ; Xiaolin XIAO ; Weibo YI ; Yuanfang CHEN ; Kun WANG ; Minpeng XU ; Dong MING
Journal of Biomedical Engineering 2023;40(3):409-417
High-frequency steady-state asymmetric visual evoked potential (SSaVEP) provides a new paradigm for designing comfortable and practical brain-computer interface (BCI) systems. However, due to the weak amplitude and strong noise of high-frequency signals, it is of great significance to study how to enhance their signal features. In this study, a 30 Hz high-frequency visual stimulus was used, and the peripheral visual field was equally divided into eight annular sectors. Eight kinds of annular sector pairs were selected based on the mapping relationship of visual space onto the primary visual cortex (V1), and three phases (in-phase[0º, 0º], anti-phase [0º, 180º], and anti-phase [180º, 0º]) were designed for each annular sector pair to explore response intensity and signal-to-noise ratio under phase modulation. A total of 8 healthy subjects were recruited in the experiment. The results showed that three annular sector pairs exhibited significant differences in SSaVEP features under phase modulation at 30 Hz high-frequency stimulation. And the spatial feature analysis showed that the two types of features of the annular sector pair in the lower visual field were significantly higher than those in the upper visual field. This study further used the filter bank and ensemble task-related component analysis to calculate the classification accuracy of annular sector pairs under three-phase modulations, and the average accuracy was up to 91.5%, which proved that the phase-modulated SSaVEP features could be used to encode high- frequency SSaVEP. In summary, the results of this study provide new ideas for enhancing the features of high-frequency SSaVEP signals and expanding the instruction set of the traditional steady state visual evoked potential paradigm.
Humans
;
Evoked Potentials, Visual
;
Brain-Computer Interfaces
;
Healthy Volunteers
;
Signal-To-Noise Ratio
5.Bibliometric and bioinformatics analysis of genetic literature on susceptibility to noise induced hearing loss.
Hui Min WANG ; Jia Di GUO ; Bo Shen WANG ; Bao Li ZHU
Chinese Journal of Industrial Hygiene and Occupational Diseases 2023;41(1):43-47
Objective: To summarize and analyse of literature on the susceptibility genes of noise induced hearing loss (NIHL) , and the key genes were screened and obtained by bioinformatics method, so as to provide reference for the prevention research of NIHL. Methods: In September 2021, Based on CNKI, NCBI Pubmed database and Web of Science database, this paper conducted bibliometric analysis and bioinformatics analysis on the genetic literature related to the susceptibility to noise-induced hearing loss from 1999 to 2020. Endnote X9 software and the WPS office software were used for bibliometric analysis, and online software STRING and Cytoscape software were used for bioinformatics analysis. Results: A total of 131 literatures were included in the study, involving 40 genes in total. Bibliometric analysis shows that 131 papers which included 36 Chinese articles and 95 English articles were published in 63 biomedical journals; the highest number of published articles was 19 in 2020. Bioinformatics analysis suggests that GAPDH、SOD2、SOD1、CAT、CASP3、IL6 and other genes play a key role in the interaction network. The involved pathways mainly include MAP2K and MAPK activations, PTEN regulation, P53-depardent G1 DNA damage response, signaoling by BRAF and RAF fusions and soon. Conclusion: The study of noise induced hearing loss involves multi gene biological information, and bioinformatics analysis is helpful to predict the occurrence and development of noise induced hearing loss.
Humans
;
Hearing Loss, Noise-Induced/epidemiology*
;
Genetic Predisposition to Disease
;
Polymorphism, Single Nucleotide
;
Computational Biology
;
Bibliometrics
;
Noise, Occupational
6.Research on early warning model of the hearing loss of workers exposed to noise.
Hai Hui QI ; Yi Yi DU ; Yu TIAN ; Yong Wei WANG ; Li Ming QUAN ; Ding Lun ZHOU
Chinese Journal of Industrial Hygiene and Occupational Diseases 2023;41(1):47-51
Objective: To explore the change of hearing threshold of workers exposed to noise, establish an individual-based hearing loss early warning model, accurately and differentiated the health of workers exposed to noise. Methods: In September 2019, all physical examination data of 561 workers exposed to noise from an enterprise were collected since their employment. Three indicators of average hearing threshold of the better ear, namely, at high frequency, 4000 Hz and speech frequency, were constructed. The generalized estimating equation (GEE) was used to adjust gender and age and establish the warning model of each indicator. Finally, sensitive indicators and warning models were screened according to AUC and Yoden index. Results: Among the 561 workers exposed to noise, 26 (4.6%) workers had hearing loss. The sensitivity indicators were the average hearing threshold at speech frequency ≥20 dB, high frequency ≥30 dB and 4000 Hz ≥25 dB. The AUC of each index was 0.602, 0.794 and 0.804, and the Youden indexes were 0.204, 0.588 and 0.608, respectively. In GEE of hearing loss warning models, high-frequency hearing threshold ≥20 dB and 4000 Hz hearing threshold ≥25 dB were the optimal models, with AUC of 0.862. Conclusion: Combined with the changes of individual hearing threshold over the years, can accurately assess the risk of individual hearing loss of workers exposed to noise.
Humans
;
Hearing Loss, Noise-Induced/diagnosis*
;
Noise, Occupational/adverse effects*
;
Audiometry
;
Deafness
;
Employment
;
Occupational Exposure/adverse effects*
;
Occupational Diseases/diagnosis*
7.Comparison of ZOOMit-DWI sequence and conventional DWI sequence in endometrial cancer.
Shixiong TANG ; Chun FU ; Hongliang CHEN ; Enhua XIAO ; Yicheng LONG ; Dujun BIAN
Journal of Central South University(Medical Sciences) 2023;48(1):76-83
OBJECTIVES:
Magnetic resonance diffusion-weighted imaging (DWI) has important clinical value in diagnosis and curative effect evaluation on endometrial carcinoma. How to improve the detection rate of endometrial small lesions by DWI is the research focus of MRI technology. This study aims to analyze the image quality of small field MRI ZOOMit-DWI sequence and conventional single-shot echo-planar imaging (SS-EPI) DWI sequence in the scanning of endometrial carcinoma, and to explore the clinical value of ZOOMit-DWI sequence.
METHODS:
A total of 37 patients with endometrial carcinoma diagnosed by operation and pathology in the Second Xiangya Hospital of Central South University from July 2019 to May 2021 were collected. All patients were scanned with MRI ZOOMit-DWI sequence and SS-EPI DWI sequence before operation. Two radiologists subjectively evaluated the anatomical details, artifacts, geometric deformation and focus definition of the 2 groups of DWI images. At the same time, the signal intensity were measured and the signal-to-noise ratio (SNR), contrast to noise ratio (CNR), and apparent diffusion coefficient (ADC) of the 2 DWI sequences were calculated for objective evaluation. The differences of subjective score, objective score and ADC value of the 2 DWI sequences were analyzed.
RESULTS:
The SNR of the ZOOMit-DWI group was significantly higher than that of the SS-EPI DWI group (301.96±141.85 vs 94.66±41.26), and the CNR of the ZOOMit-DWI group was significantly higher than that of the SS-EPI DWI group (185.05±105.45 vs 57.91±31.54, P<0.05). There was no significant difference in noise standard deviation between the ZOOMit-DWI group and the SS-EPI DWI group (P>0.05). The subjective score of anatomical detail and focus definition in the ZOOMit-DWI group was significantly higher than that of the SS-EPI DWI group (both P<0.05). The subjective score of artifacts and geometric deformation of ZOOMit-DWI group was significantly lower than that of the SS-EPI DWI group (both P<0.05). ADC had no significant difference between the ZOOMit-DWI group and the SS-EPI DWI group (P>0.05).
CONCLUSIONS
The image quality of ZOOMit-DWI is significantly higher than that of conventional SS-EPI DWI. In the MRI DWI examination of endometrial carcinoma, ZOOMit-DWI can effectively reduce the geometric deformation and artifacts of the image, which is more conducive to clinical diagnosis and treatment.
Female
;
Humans
;
Signal-To-Noise Ratio
;
Endometrial Neoplasms/diagnostic imaging*
;
Diffusion Magnetic Resonance Imaging/methods*
;
Endometrium
;
Echo-Planar Imaging/methods*
;
Reproducibility of Results
8.Influence of hearing aid on speech recognition ability, psychology and cognitive function of presbycusis.
Lin Lan JIANG ; Yue Nong JIAO ; Jin Yu WANG ; Mei Chan ZHU ; Ying LIN
Chinese Journal of Otorhinolaryngology Head and Neck Surgery 2023;58(2):160-165
Humans
;
Presbycusis
;
Speech Perception
;
Hearing Aids
;
Cognition
;
Noise
9.A comprehensive review on photon-counting computed tomography: Principles, technical hurdles and analysis of clinical applications.
Haowei ZHANG ; Shuhan LI ; Ying LIU ; Heqing LU
Journal of Biomedical Engineering 2023;40(5):1012-1018
In recent years, photon-counting computed tomography (PCD-CT) based on photon-counting detectors (PCDs) has become increasingly utilized in clinical practice. Compared with conventional CT, PCD-CT has the potential to achieve micron-level spatial resolution, lower radiation dose, negligible electronic noise, multi-energy imaging, and material identification, etc. This advancement facilitates the promotion of ultra-low dose scans in clinical scenarios, potentially detecting minimal and hidden lesions, thus significantly improving image quality. However, the current state of the art is limited and issues such as charge sharing, pulse pileup, K-escape and count rate drift remain unresolved. These issues could lead to a decrease in image resolution and energy resolution, while an increasing in image noise and ring artifact and so on. This article systematically reviewed the physical principles of PCD-CT, and outlined the structural differences between PCDs and energy integration detectors (EIDs), and the current challenges in the development of PCD-CT. In addition, the advantages and disadvantages of three detector materials were analysed. Then, the clinical benefits of PCD-CT were presented through the clinical application of PCD-CT in the three diseases with the highest mortality rate in China (cardiovascular disease, tumour and respiratory disease). The overall aim of the article is to comprehensively assist medical professionals in understanding the technological innovations and current technical limitations of PCD-CT, while highlighting the urgent problems that PCD-CT needs to address in the coming years.
Tomography, X-Ray Computed/methods*
;
Photons
;
Noise
;
China
;
Phantoms, Imaging
10.Analysis of verification results of protective effects of hearing protectors in different industries.
Han Xue SHI ; Shi Biao SU ; Ming LIU ; Rong Zong LI ; Tian Jian WANG ; Bin XIAO
Chinese Journal of Industrial Hygiene and Occupational Diseases 2023;41(5):333-337
Objective: To get insight into the current practice of noise reduction effect of workers as they wore hearing protectors in different domestic enterprises and the possible affected factors. Methods: From October 2020 to April 2021, using a random sampling method, 1197 workers exposed to noise in petrochemical factories, textile factories, and parts manufacturing factories were selected as the study subjects. The noise reduction effect of hearing protectors worn by workers in daily use was tested using a hearing protector suitability testing system. The personal sound attenuation level (PAR) was compared among workers in three enterprises, Targeted intervention and repetitive testing were conducted for workers who did not meet the noise reduction effect required by the enterprise, and the changes in PAR of workers before and after the intervention were compared. The comparison of baseline PARs between two or more groups was performed using the Mann Whitney test, the comparison of baseline PARs with post intervention PARs was performed using the Wilcoxon signed rank sum test, and the comparison of qualitative data between two or more groups was performed using the Chi square test. Results: The median baseline PAR for all workers was 15 dB. Men, age<30 years old, education level at or above college level, working experience of 5 to 15 years, and those who used hearing protectors for 5 to 15 years had higher PARs, with statistically significant differences (P<0.05). The median difference in baseline PAR among workers from three enterprises was statistically significant (H=175.06, P<0.01). The median PAR of subjects who did not pass the baseline increased from 3 dB to 21 dB after intervention (Z=-27.92, P<0.01) . Conclusion: Some workers wearing hearing protectors do not meet the required PAR, and low PARs may be related to incorrect wearing methods and incorrect selection of hearing protectors. As a tool for testing, training, and assisting in selection, the hearing protector suitability testing system is of great significance for worker hearing protection.
Male
;
Humans
;
Adult
;
Hearing Loss, Noise-Induced/prevention & control*
;
Ear Protective Devices
;
Noise, Occupational/prevention & control*
;
Hearing
;
Audiometry

Result Analysis
Print
Save