1.A new biosynthesis route for production of 5-aminovalanoic acid, a biobased plastic monomer.
Yaqi KANG ; Ruoshi LUO ; Fanzhen LIN ; Jie CHENG ; Zhen ZHOU ; Dan WANG
Chinese Journal of Biotechnology 2023;39(5):2070-2080
5-aminovalanoic acid (5AVA) can be used as the precursor of new plastics nylon 5 and nylon 56, and is a promising platform compound for the synthesis of polyimides. At present, the biosynthesis of 5-aminovalanoic acid generally is of low yield, complex synthesis process and high cost, which hampers large-scale industrial production. In order to achieve efficient biosynthesis of 5AVA, we developed a new pathway mediated by 2-keto-6-aminohexanoate. By combinatory expression of L-lysine α-oxidase from Scomber japonicus, α-ketoacid decarcarboxylase from Lactococcus lactis and aldehyde dehydrogenase from Escherichia coli, the synthesis of 5AVA from L-lysine in Escherichia coli was achieved. Under the initial conditions of glucose concentration of 55 g/L and lysine hydrochloride of 40 g/L, the final consumption of 158 g/L glucose and 144 g/L lysine hydrochloride, feeding batch fermentation to produce 57.52 g/L of 5AVA, and the molar yield is 0.62 mol/mol. The new 5AVA biosynthetic pathway does not require ethanol and H2O2, and achieved a higher production efficiency as compared to the previously reported Bio-Chem hybrid pathway mediated by 2-keto-6-aminohexanoate.
Nylons
;
Lysine/metabolism*
;
Hydrogen Peroxide/metabolism*
;
Metabolic Engineering
;
Plastics/metabolism*
;
Fermentation
;
Escherichia coli/metabolism*
;
Aminocaproates/metabolism*
3.Research progress on the biomimetic remineralization of hard tooth tissues based on polyamide-amine dendrimer.
Ke-Zhen XIANG ; Liang CHEN ; De-Qin YANG
West China Journal of Stomatology 2020;38(6):692-696
Polyamide-amine (PAMAM) dendrimer, a new hyperbranched macromolecular polymer, is considered an "artificial protein" by many scholars on account of its excellent chemical and biological characteristics. PAMAM has internal cavities and a large number of reactive terminal groups. These structures allow the polymer to be used as a bionic macromoleculethat could simulate the biomimetic mineralization of the natural organic matrix on the surface of tooth tissue. Specifically, PAMAM can beused as an organic template to regulate mineral nucleation and crystal growth; thus, the polymerisa more ideal dental restoration material than traditional allogenic materials. This article reviews research progress on thePAMAM-induced biomimetic mineralization of hard tooth tissues.
Amines
;
Biomimetics
;
Dendrimers
;
Humans
;
Nylons
;
Tooth Remineralization
4.Surface alterations following instrumentation with a nylon or metal brush evaluated with confocal microscopy
Young Sung KIM ; Jun Beom PARK ; Youngkyung KO
Journal of Periodontal & Implant Science 2019;49(5):310-318
PURPOSE: Surface alterations of titanium discs following instrumentation with either a nylon brush or a metal brush were evaluated. METHODS: A total of 27 titanium discs with 3 surface types (9 discs for each type), including machined (M) surfaces, sandblasted and acid-etched (SA) surfaces, and surfaces treated by resorbable blast media (RBM), were used. Three discs were instrumented with a nylon brush, another 3 discs were instrumented with a metal brush, and the remaining 3 discs were used as controls for each surface type. Surface properties including the arithmetic mean value of a linear profile (Ra), maximum height of a linear profile (Rz), skewness of the assessed linear profile (Rsk), arithmetic mean height of a surface (Sa), maximum height of a surface (Sz), developed interfacial area ratio (Sdr), skewness of a surface profile (Ssk), and kurtosis of a surface profile (Sku) were measured using confocal microscopy. RESULTS: Instrumentation with the nylon brush increased the Ra, Sa, and Sdr of the M surfaces. On the SA surfaces, Ra, Sa and Sdr decreased after nylon brush use. Meanwhile, the roughness of the RBM surface was not affected by the nylon brush. The use of the metal brush also increased the Ra, Sa, and Sdr of the M surface; however, the increase in Sdr was not statistically significant (P=0.119). The decreases in the Rz, Sz, Ra, Sa, and Sdr of the SA surfaces were remarkable. On the RBM surfaces, the use of the metal brush did not cause changes in Ra and Sa, whereas Rz, Sz, and Sdr were reduced. CONCLUSIONS: Titanium surfaces were altered when instrumented either with a nylon brush or a metal brush. Hence, it is recommended that nylon or metal brushes be used with caution in order to avoid damaging the implant fixture/abutment surface.
Dental Implants
;
Microscopy, Confocal
;
Nylons
;
Peri-Implantitis
;
Surface Properties
;
Titanium
5.Physical properties and color stability of injection-molded thermoplastic denture base resins
So Yeon SONG ; Kyoung Soo KIM ; Jeong Yol LEE ; Sang Wan SHIN
The Journal of Advanced Prosthodontics 2019;11(1):32-40
PURPOSE: The purpose of this study was to compare mechanical and physical properties of injection-molded thermoplastic denture base resins. MATERIALS AND METHODS: In this study, six commercially available products (VA; Valplast, LC; Lucitone, ST; Smiltone, ES; Estheshot-Bright, AC; Acrytone, WE; Weldenz) were selected from four types of thermoplastic denture base materials (Polyamide, Polyester, Acrylic resin and Polypropylene). The flexural properties and shore D hardness have been investigated and water sorption and solubility, and color stability have evaluated. RESULTS: For the flexural modulus value, ES showed the highest value and WE showed significantly lower value than all other groups (P < .05). Most of experimental groups showed weak color stability beyond the clinically acceptable range. CONCLUSION: Within the limits of this study, thermoplastic denture base resin did not show sufficient modulus to function as a denture base. In addition, all resins showed discoloration with clinical significance, and especially polyamides showed the lowest color stability.
Denture Bases
;
Dentures
;
Hardness
;
Nylons
;
Polyesters
;
Solubility
;
Water
6.Fluid Dynamics of Small Diameter Tubes Used in Membrane-tube Type Glaucoma Shunt Devices
Jong Chul HAN ; Young Hoon HWANG ; Byung Heon AHN
Korean Journal of Ophthalmology 2019;33(4):371-378
PURPOSE: To investigate the outflow characteristics of silicone tubes with intraluminal stents used in membrane-tube (MT) type glaucoma shunt devices. METHODS: The silicone tubes used in MicroMT (internal diameter of 100 µm with a 7-0 nylon intraluminal stent) and Finetube MT (internal diameter of 200 µm with a 5-0 nylon intraluminal stent) were connected to a syringe-pump that delivered a continuous flow of distilled water at flow rates of 2, 5, 10, and 25 µL/min. The pressures and resistances of tubes were measured at a steady flow rate with full-length, half-length, and absence of intraluminal stents. RESULTS: The mean outflow resistance of the two types of tubes ranged from 3.0 ± 1.9 to 3.8 ± 1.7 mmHg/µL/min with a full-length intraluminal stent, 1.8 ± 1.1 to 2.2 ± 1.1 mmHg/µL/min with a half-length intraluminal stent, and 0.1 ± 0.0 to 0.2 ± 0.0 mmHg/µL/min without an intraluminal stent. Theoretically, for a physiologic state with a flow rate of 2 µL/min and episcleral venous pressure of 6 mmHg, the mean pressures of tubes were expected to be 13.2 ± 3.0, 10.5 ± 2.4, and 6.4 ± 0.2 mmHg in MicroMT with full-length, half-length, and absence of intraluminal stents, respectively, and 12.5 ± 3.9, 9.6 ± 2.4, and 6.2 ± 0.2 mmHg in Finetube MT with full-length, half-length, and absence of intraluminal stents, respectively. The pressure variance also decreased with intraluminal stent retraction (p < 0.01). CONCLUSIONS: The small diameter tubes of 100 and 200 µm internal diameters, with 7-0 and 5-0 nylon intraluminal stents, respectively, used in the MT-type glaucoma shunt device showed safe and effective outflow characteristics.
Glaucoma
;
Hydrodynamics
;
Intraocular Pressure
;
Nylons
;
Silicon
;
Silicones
;
Stents
;
Venous Pressure
;
Water
7.Utilizing a Previous Silicone Band Track in Recurred Retinal Detachment
Journal of the Korean Ophthalmological Society 2019;60(7):696-700
PURPOSE: We report a case of utilizing a previous silicone band track in the reoperation of scleral encircling. CASE SUMMARY: An 8-year-old male presented with rhegmatogenous retinal detachment in the right eye. Five days after this diagnosis, he received scleral buckling surgery and cryopexy to seal the retinal tear. One month after surgery, a fundus examination showed subretinal fluid at the inferior site of the scleral buckle. He underwent scleral encircling surgery and a cryopexy procedure. The patient has had an uneventful postoperative course, and the retina has remained attached over a follow-up period of 9 months. However, exotropia and hypotropia developed in the right eye. Diagnosis of restrictive strabismus due to tissue adhesion around the silicone band was made. The encircling band was therefore removed and laser photocoagulation was performed 360° around the retina. Twenty-four hours after surgery, a fundus examination showed subretinal fluid. He received 360° scleral encircling surgery not using the 360° conjunctival peritomy. After confirming a previous encircling tract using #0-0 polydioxanone as a guide, #5-0 Nylon was tied to the end of the guide and inserted through the encircling tract with the end sutured with the silicone band. The silicone band was inserted into the encircling tract by pulling the #5-0 Nylon as a guide. Ophthalmoscopy revealed an attached retina with indentation of the scleral buckle at 360°. CONCLUSIONS: For reoperation in patients who previously underwent scleral encircling surgery, using the previous scleral encircling tract may be effective in cases with conjunctival and tissue adhesion.
Child
;
Diagnosis
;
Exotropia
;
Follow-Up Studies
;
Humans
;
Light Coagulation
;
Male
;
Nylons
;
Ophthalmoscopy
;
Polydioxanone
;
Reoperation
;
Retina
;
Retinal Detachment
;
Retinal Perforations
;
Retinaldehyde
;
Scleral Buckling
;
Silicon
;
Silicones
;
Strabismus
;
Subretinal Fluid
;
Tissue Adhesions
8.Fistula Formation Between the Disc and Dura after Percutaneous Endoscopic Lumbar Discectomy: A Case Report
Hak Sun KIM ; Hyoung Bok KIM ; Hoon Jae CHUNG ; Jea Ho YANG
Journal of Korean Society of Spine Surgery 2018;25(4):180-184
STUDY DESIGN: Case report OBJECTIVES: To document fistula formation between the disc and dura by an unrecognized dural tear after percutaneous endoscopic lumbar discectomy (PELD). SUMMARY OF LITERATURE REVIEW: The risk of durotomy is relatively low with PELD, but cases of unrecognized durotomies have been reported. An effective diagnostic tool for such situations has not yet been identified. MATERIALS AND METHODS: A patient twice underwent transforaminal PELD under the diagnosis of a herniated lumbar disc at L4-5. She still complained of intractable pain and motor weakness around the left lower extremity at 6 months postoperatively. Magnetic resonance imaging showed no specific findings suggestive of violation of the nerve root. However, L5 and S1 nerve root injury was noted on electromyography. An exploratory operation was planned to characterize damage to the neural structures. RESULTS: In the exploration, a dural tear was found at the previous operative site, along with a fistula between the disc and dura was also found at the dural tear site. The durotomy site was located on the ventrolateral side of the dura and measured approximately 5 mm. The durotomy site was repaired with Nylon 5-0 and adhesive sealants. The patient's preoperative symptoms diminished considerably. CONCLUSIONS: Fistula formation between the disc and dura can be caused by an unrecognized dural tear after PELD. Discography is a reliable diagnostic tool for fistulas formed by an unrecognized durotomy.
Adhesives
;
Diagnosis
;
Diskectomy
;
Electromyography
;
Fistula
;
Humans
;
Lower Extremity
;
Magnetic Resonance Imaging
;
Nylons
;
Pain, Intractable
;
Tears
9.Nonthermal plasma on the shear bond strength of relining resin to thermoplastic denture base resin.
Liezl MANALOTO-CEBALLOS ; Wilmart LABRIAGA ; So Yeon SONG ; Jin Hong PARK ; Jeong Yol LEE ; Sang Wan SHIN
The Journal of Korean Academy of Prosthodontics 2018;56(3):199-205
PURPOSE: This study evaluated the effect of nonthermal plasma treatment on the bond strength of autopolymerizing relining resin to the injection molded thermoplastic denture base resins (TDBRs) with different surface treatments. MATERIALS AND METHODS: Acrylic Resin (Acrytone), Polyester (Estheshot-Bright), Polyamide (Valplast) and Polypropylene (Weldenz) were subjected to various surface treatments: No treatment, Nonthermal plasma, Sandblasting, Sandblasting and nonthermal plasma. Specimens were bonded using an autopolymerizing relining resin. Shear bond strength was tested using universal testing machine with crosshead speed of 1 mm/min. Statistical analysis by two-way analysis of variance with Tukey's test post hoc was used. RESULTS: Acrytone showed significantly higher shear bond strength value among other TDBR group while Weldenz had the lowest. The sandblasting and nonthermal plasma condition had significantly higher shear bond strength value in all of the resin groups (P < .05). CONCLUSION: The use of nonthermal plasma treatment showed limited effect on the shear bond strength between TDBRs and relining resin, and combination of nonthermal plasma and sandblasting improved the shear bond strength between TDBR and reline material.
Denture Bases*
;
Dentures*
;
Fungi
;
Nylons
;
Plasma*
;
Polyesters
;
Polypropylenes
10.A comparative study of immediate wound healing complications following cleft lip repair using either absorbable or non-absorbable skin sutures.
Akeem O ALAWODE ; Michael O ADEYEMI ; Olutayo JAMES ; Mobolanle O OGUNLEWE ; Azeez BUTALI ; Wasiu L ADEYEMO
Journal of the Korean Association of Oral and Maxillofacial Surgeons 2018;44(4):159-166
OBJECTIVES: The aim of the study was to compare wound healing complications following the use of either absorbable or non-absorbable sutures for skin closure in cleft lip repair. MATERIALS AND METHODS: This was a randomized controlled trial conducted at the Department of Oral and Maxillofacial Surgery, Lagos University Teaching Hospital, Idi Araba, Lagos State, Nigeria. Sixty subjects who required either primary or secondary cleft lip repair and satisfied all the inclusion criteria were recruited and randomized into two groups (Vicryl group or Nylon group). The surgical wounds in all subjects were examined on 3rd, 7th, and 14th postoperative days (POD) for presence or absence of tissue reactivity, wound dehiscence, and local wound infection. RESULTS: Hemorrhage, tissue reactivity, wound dehiscence, and local wound infection were identified as wound healing complications following cleft lip repair. The incidence of postoperative wound healing complications on POD3 was 33.3%. Tissue reactivity was more common throughout the evaluation period with the use of an absorbable (Vicryl) suture compared to a non-absorbable (Nylon) suture, although the difference was statistically significant only on POD7 (P=0.002). There were no significant differences in the incidences of wound dehiscence and infection between the two groups throughout the observation period. CONCLUSION: There were no statistically significant differences in the incidences of wound dehiscence and surgical site wound infection following the use of either Vicryl or Nylon for skin closure during cleft lip repair. However, more cases of tissue reactivity were recorded in the Vicryl group than in the Nylon group on POD7. Particular attention must be paid to detect the occurrence of wound healing complications, most especially tissue reactivity, whenever a Vicryl suture is used for skin closure in cleft lip repair.
Cleft Lip*
;
Hemorrhage
;
Hospitals, Teaching
;
Incidence
;
Nigeria
;
Nylons
;
Polyglactin 910
;
Skin*
;
Surgery, Oral
;
Sutures*
;
Wound Healing*
;
Wound Infection
;
Wounds and Injuries*

Result Analysis
Print
Save
E-mail