1.Research on multi antigen extended matching transfusion in RhCE alloantibody positive patients with blood diseases
Pin YI ; Mingming WANG ; Yi ZHU ; Xintang DANG ; Ziyu OU ; Fan WU ; Chaopeng SHAO ; Changlin WU
Chinese Journal of Blood Transfusion 2025;38(5):678-683
Objective: To analyze the changes in homologous immunity after RhCE-matched transfusion in positive patients with RhCE blood group antibodies, and to provide precise transfusion strategies for chronic anemia patients. Methods: Patients with chronic anemia in our hospital from January 2020 to March 2024 (continuously receiving blood transfusions for more than 6 months) were enrolled, and 63 cases of unexpected antibody screening positive and identified as RhCE blood group antibodies were selected as the research subjects. The changes in unexpected antibody yield rate after ABO and RhCcDEe isotype blood transfusion were observed. Patients with MNS, Kidd, or Lewis blood group antibodies were screened for corresponding negative donors using monoclonal antibodies for extended typing transfusion based on RhCcEe typing, and the changes in unexpected antibody yield rate after transfusion were observed. Blood group genotyping was performed when serological techniques failed to resolve discrepancies or detect abnormal antigen expression. Results: After RhCcDEe-matched transfusions, RhCE antibodies disappeared in 62 patients, while 1 patient developed anti-Ce. The latter did not develop blood type isotype immunity after receiving RhccEE donor blood. Among the 62 patients, 9 developed unexpected antibodies against other systems: anti-M (4 cases), anti-Mur (2), anti-S (1), anti-Jka (1), and anti-Lea (1). No additional alloimmunization occurred after extended antigen-matched transfusions. A patient with serologically weak e phenotype was genotyped as DCe/DcE, with gene sequencing revealing an 827C>A mutation in exon 6 of the RHCE gene, forming the RHCE
01.31 allele. Conclusion: Precise transfusion strategies incorporating RhCE, MNS, Kidd, and Lewis blood group antigen typing can reduce the probability of blood group homologous immunity. RhCE complex antibodies and RhCE variants pose difficulties for clinical RhCE typing transfusion, which can be addressed through cross-matching and genetic analysis.
2.Clinical application of exempting anti-D monitoring in pregnant women with Asian-type DEL
Pin YI ; Ziyu OU ; Xiaoxiao SUN ; Mingming WANG ; Changlin WU ; Chaopeng SHAO
Chinese Journal of Blood Transfusion 2025;38(6):766-771
Objective: To evaluate the feasibility of exempting Asian-type DEL pregnant women from anti-D monitoring and RhD immunoglobulin prophylaxis injections by comparing and analyzing the clinical incidence of anti-D alloimmunization between Asian-type DEL pregnant women and true RhD-negative pregnant women. Methods: A total of 165 pregnant women who were initially screened as RhD negative by the saline method and received medical treatment in our hospital from December 2022 to August 2024 were collected as the research subjects. Absorption and elution tests, DEL genotyping, and gene sequencing were used to divide the pregnant women into the Asian-type DEL group and the true negative group. After obtaining informed consent, the following clinical management plan was implemented for pregnant women with Asian-type DEL: exemption from routine anti-D antibody detection, exemption from RhD immunoglobulin prophylaxis, and transfusion of RhD-positive red blood cells. Blood samples of newborns were sent for examination of hemolytic disease of the fetus and newborn (HDFN). The routine management plan was implemented for true negative pregnant women. The incidence of alloimmunization and HDFN was comparatively analyzed between the two groups. Results: Among 165 initially screened RhD negative pregnant women, serological testing and genotyping confirmed 42 as Asian-type DEL, 9 as D variant, and 114 as true negative. Among 42 pregnant women with Asian-type DEL, 3 cases tested positive for HDFN due to receiving RhD immunoglobulin prophylaxis injection. The remaining 39 cases were exempted from anti-D testing after being fully informed of the risk, and did not receive RhD immunoglobulin prophylaxis. The HDFN tests were all negative. In the true negative group, anti-D antibodies were detected in 20 cases, of which 6 cases tested positive for HDFN. A pregnant woman with Asian -type DEL did not show RhD homologous immune response after receiving 2 units of RhD positive red blood cells. Statistical analysis revealed a significantly lower risk of anti-D alloimmunization in Asian-type DEL carriers compared to true D-negative pregnant women (P<0.05). Conclusion: Pregnant women with Asian-type DEL can be exempted from routine anti-D antibody testing and do not require routine RhD immunoglobulin prophylaxis injections.
3.Bionic design,preparation and clinical translation of oral hard tissue restorative materials
Han ZHAO ; Yan WEI ; Xuehui ZHANG ; Xiaoping YANG ; Qing CAI ; Chengyun NING ; Mingming XU ; Wenwen LIU ; Ying HUANG ; Ying HE ; Yaru GUO ; Shengjie JIANG ; Yunyang BAI ; Yujia WU ; Yusi GUO ; Xiaona ZHENG ; Wenjing LI ; Xuliang DENG
Journal of Peking University(Health Sciences) 2024;56(1):4-8
Oral diseases concern almost every individual and are a serious health risk to the popula-tion.The restorative treatment of tooth and jaw defects is an important means to achieve oral function and support the appearance of the contour.Based on the principle of"learning from the nature",Deng Xu-liang's group of Peking University School and Hospital of Stomatology has proposed a new concept of"microstructural biomimetic design and tissue adaptation of tooth/jaw materials"to address the worldwide problems of difficulty in treating dentine hypersensitivity,poor prognosis of restoration of tooth defects,and vertical bone augmentation of alveolar bone after tooth loss.The group has broken through the bottle-neck of multi-stage biomimetic technology from the design of microscopic features to the enhancement of macroscopic effects,and invented key technologies such as crystalline/amorphous multi-level assembly,ion-transportation blocking,and multi-physical properties of the micro-environment reconstruction,etc.The group also pioneered the cationic-hydrogel desensitizer,digital stump and core integrated restora-tions,and developed new crown and bridge restorative materials,gradient functionalisation guided tissue regeneration membrane,and electrically responsive alveolar bone augmentation restorative membranes,etc.These products have established new clinical strategies for tooth/jaw defect repair and achieved inno-vative results.In conclusion,the research results of our group have strongly supported the theoretical im-provement of stomatology,developed the technical system of oral hard tissue restoration,innovated the clinical treatment strategy,and led the progress of the stomatology industry.
4.Construction of blood quality monitoring indicator system in blood banks of Shandong
Qun LIU ; Xuemei LI ; Yuqing WU ; Zhiquan RONG ; Zhongsi YANG ; Zhe SONG ; Shuhong ZHAO ; Lin ZHU ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xiaojuan FAN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):249-257
【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level
5.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
6.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
7.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
8.Optimization of 18F-FDG PET/CT semi-quantitative diagnostic model for children with autoimmune encephalitis with epilepsy and negative MRI
Ziyuan LI ; Jing WU ; Shuqi WU ; Mingming CAO ; Suyun CHEN ; Ling LI ; Hui WANG ; Yafu YIN
Chinese Journal of Nuclear Medicine and Molecular Imaging 2024;44(4):213-219
Objective:To investigate the value of 18F-FDG PET/CT imaging in the diagnosis of suspected autoimmune encephalitis (AE) in children with epilepsy and negative MRI. Methods:From May 2019 to August 2022, 94 suspected AE children (49 males, 45 females; age 1-15 years) with epilepsy and negative MRI who underwent brain 18F-FDG PET/CT imaging at Xinhua Hospital Affiliated to Shanghai Jiao Tong University School of Medicine were retrospectively analyzed. All patients were divided into AE and non-AE groups based on clinical final diagnosis. The effectiveness of visual diagnosis was evaluated. The cortical lesion extent score (S), and SUV max, SUV mean and minimum of SUV (SUV min) of cortical lesions (L), basal ganglia (B) and thalamus (T) were measured and SUV ratios (SUVR) of L/B or L/T were obtained. Independent-sample t test or Mann-Whitney U test was used to analyze data. Binary logistic regression analysis was used to screen the diagnostic factors of AE, and a diagnostic model was established. The diagnostic efficiency was evaluated by ROC curve analysis and Delong test. Results:There were 53 cases in AE group and 41 cases in non-AE group. Based on visual analysis, the sensitivity, specificity and accuracy of 18F-FDG PET/CT for AE were 100%(53/53), 43.9%(18/41) and 75.5%(71/94), respectively. Differences of LSUV max, LSUV mean, LSUV min, L/BSUVR max, L/BSUVR mean, L/BSUVR min, L/TSUVR max, L/TSUVR mean, L/TSUVR min and S between AE and non-AE groups were statistically significant ( z=-6.74, t values: from -8.51 to -3.97, all P<0.001). ROC curve analysis showed that the AUC of L/BSUVR max was the highest (0.914) among visual analysis and semi-quantitative parameters. Logistic regression analysis showed that S (odds ratio ( OR)=11.40, 95% CI: 2.18-59.52, P=0.004), L/BSUVR max( OR=13.19, 95% CI: 2.11-82.51, P=0.006) and L/TSUVR max( OR=9.66, 95% CI: 1.57-59.55, P=0.015) were independent diagnostic factors for AE. Regression model was established: P=1/(1+ e - x), x=2.433×S+ 2.580×L/BSUVR max+ 2.267×L/TSUVR max-3.802. The AUC of this model was 0.948, with the sensitivity, specificity and accuracy of 98.1%(52/53), 90.2%(37/41) and 94.7%(89/94), respectively. The diagnostic efficacy of the optimized scoring system was consistent with the pre-optimization model, and were both superior to L/BSUVR max(both z=2.01, both P=0.040). Conclusion:The diagnostic model and scoring system based on the semi-quantitative analysis of 18F-FDG PET/CT have better diagnostic efficacy for AE and are superior to semi-quantitative parameters alone.
9.Rapid Analysis of the Chemical Composition of Zhangbang Nine Steaming Nine Sun-dying Rehmanniae Radix Based on UPLC-Q-TOF-MS Technique and Study on the Function of Solid Excipiemts in Alleviating the "Nourishing and Spleen-impairing" in Rehmanniae Radix
Xudong ZHU ; Wei YAO ; Feixia YAN ; Dong HUANG ; Song WANG ; Na ZHU ; Mingming YUAN ; Liping HUANG ; Yi WU
Chinese Journal of Modern Applied Pharmacy 2024;41(10):1332-1342
OBJECTIVE
To study the chemical composition and the function of solid excipients in relieving the "nourishing and spleen-impairing" effect of Zhangbang nine steaming nine sun-dying Rehmanniae Radix(RR) by using UPLC-Q-TOF-MS technique.
METHODS
UPLC-Q-TOF-MS was used to collect the data of Zhangbang nine steaming nine sun-dying RR, and UNIFI platform and self-built database were used for the rapid qualitative analysis and identification of the chemical components of Zhangbang nine steaming nine sun-dying RR. The effect of solid excipients on the function of RR "nourishing and spleen-impairing" was investigated by establishing a mouse model of low gastric motility and measuring its gastric residual rate and small intestine propulsion rate.
RESULTS
The UPLC-Q-TOF-MS and UNFI platforms identified 76 chemical components in nine steaming nine sun-dying RR, including 9 iridoid glycosides, 11 phenylethyl glycosides, 31 flavonoids, 6 saccharides and 19 other compounds; the results of gastric emptying and small intestinal propulsion experiments on mice showed that Zhangbang nine steaming nine sun-dying RR had gastric emptying and intestinal propulsion effects.
CONCLUSION
This method can be used for the rapid identification and analysis of nine steaming nine sun-dying RR, which has solid excipients Citri Reticulatae Pericarpium and Amomi Fructus to alleviate the "nourishing and spleen-impairing" function of RR. This study can provide a reference for quality control and elucidation of the material basis of the medicinal effects of specialty beverage of Zhangbang nine steaming nine sun-dying RR.
10.Primary biliary cholangitis-autoimmune hepatitis overlap syndrome comorbid with pulmonary cryptococcosis:A case report
Mingming ZHANG ; Huan LIU ; Dongmei ZHANG ; Dongbo WU ; Hong TANG
Journal of Clinical Hepatology 2024;40(8):1666-1669
Patients with overlap syndrome(OS)of autoimmune liver disease may present with more than one biochemical,immunological,histological or cholangiography features of autoimmune liver disease(AILD)and often require a combination of immunosuppressants for treatment.Pulmonary cryptococcosis is a type of invasive pneumomycosis caused by Cryptococcus neoformans or Cryptococcus gattii and has a relatively high incidence rate in immunocompromised patients.This case report presents a patient with OS who was found to have pulmonary cryptococcosis during immunosuppressive therapy and developed abnormal liver function during antifungal treatment.Based on the liver function of the patient,the feasibility of adjusting antifungal agents was assessed,and active treatment strategies for novel cryptococcal infection were developed under the close monitoring of liver function,which helped to avoid the progression of infection.It is suggested that before the initiation of immunosuppressive therapy,systemic foci of infection should be comprehensively evaluated,and suspicious foci of infection should be monitored continuously.


Result Analysis
Print
Save
E-mail