1.Application effect of multidisciplinary team nursing model in enteral nutrition support of ICU patients
Minfei XIE ; Weili ZHAO ; Wei ZHANG ; Haiyang XU ; Nan WANG
Chinese Journal of Modern Nursing 2024;30(24):3314-3317
Objective:To explore the application effect of multidisciplinary team (MDT) nursing model in enteral nutrition support for patients in intensive care unit (ICU) .Methods:The convenient sampling method was used to select 76 patients undergoing enteral nutrition in ICU of Taizhou Hospital in Zhejiang Province from August 2020 to August 2022 as the research objects. A total of 37 patients admitted from August 2020 to August 2021 were set as the control group, and 39 patients admitted from September 2021 to August 2022 were set as the intervention group. Patients in the control group received routine nursing, while patients in the intervention group received MDT nursing model. The start time of enteral nutrition after admission to ICU, the compliance rate of enteral nutrition at 7 days after feeding, the rate of feeding interruption and the incidence of complications were compared between the two groups.Results:After intervention, the start time of enteral nutrition after admission to ICU in the intervention group was shorter than that in the control group, the compliance rate of enteral nutrition at 7 days after feeding was higher than that in the control group, and the feeding interruption rate and incidence of aspiration, nausea, vomiting and diarrhea were lower than those in the control group ( P<0.05) . Conclusions:The MDT nursing model can improve the effect of enteral nutrition support for ICU patients and reduce the incidence of enteral nutrition complications.
2.Fluid management strategies for patients with severe blast injury
Minfei YANG ; Mengyun XU ; Yu KE ; Xiao LU ; Lanlan ZHANG ; Xiaoyue YAO
Chinese Journal of Practical Nursing 2023;39(14):1105-1109
Objective:To summarize the precision fluid management of patients with severe blast injury in the emergency intensive care unit, so as to help patients smoothly pass through the dangerous period and recover smoothly.Methods:Based on the experience of fluid management in 6 patients admitted to the Second Affiliated Hospital Zhejiang University School of Medicine in the tanker truck explosion on 14 June, 2020. The main measures included: fluid volume management and dynamic adjustment; assessment of intake, output and urine volume, and dynamic adjustment of infusion volume and speed; monitoring of pulmonary oxygenation and timely adjustment of fluid resuscitation strategies; monitoring indexes and providing nursing care strategies for fluid management.Results:Finally, among 6 patients with severe blast injury, 5 patients were discharged from the hospital with follow-up treatment after they suffered from the shock and infection phases and refined fluid management, 1 patient died due to severe injury and ineffective rescue.Conclusions:Adopting individualized, phased, and refined liquid management strategy has clinical significance for patients with severe blast injury to smoothly pass the risk period.
3.Design and construction of a large 5G mobile emergency resuscitation unit
Minfei YANG ; Qiang LI ; Shanxiang XU ; Weidi SHEN ; Aina WU ; Fangmin GE ; Jungen ZHANG ; Ming ZHOU ; Jianping YE ; Mao ZHANG
Chinese Journal of Emergency Medicine 2023;32(12):1623-1627
Objective:To design a large-scale mobile emergency resuscitation unit based on 5G communication technology to improve the efficiency of prehospital transportation and treatment.Methods:The study was conducted in Hangzhou from November 2022 to September 2023. It's sorted out the application scenario requirements for prehospital first aid, transfer, and prehospital-intrahospital emergency linkage in carrying out the program design, single technology testing, onboard debugging, and integration debugging phases sequentially.Results:In September 2023, a large-scale 5G mobile emergency resuscitation unit was completed and delivered. The unit was converted from an electric bus and consists of five parts: (1) Vehicle appearance: the vehicle is 12.9 meters long, 2.3 meters wide and 2.6 meters high, with a single mileage of 200 kilometers; (2) The overall internal structure: the vehicle has one resuscitation bed and two stretcher positions. Additionally, there is a comprehensive operating table located at the front of the vehicle. The middle of the vehicle is equipped with a central digital control screen. (3) First aid materials and instruments: the vehicle's materials are modularly configured in accordance with the resuscitation, guardianship, surgery, inspection and testing, Communication modular configuration, equipped with a defibrillation monitor, transfer ventilator, extracorporeal membrane lung oxygenation and other critical care first aid and electrocardiogram, digital radiography, blood gas analyzer, chest pain 5 monitors and other inspection and testing equipment; (4) Vehicle communication and information systems: equipped with high-definition remote video interactive system, telemedicine terminal DP300 integrated system, a real-time panoramic experience system and centralized guardianship system; (5) Vehicle disinfection: a plasma disinfector installed on the top of the car can meet the hospital disinfection hygiene standardsⅡ class environmental management requirements.Conclusions:Incorporating 5G communication technology, the large-scale mobile emergency resuscitation unit is equipped with various advanced treatment equipment and remote consultation systems. It can accommodate the resuscitation needs of the most critically ill patients, offering substantial support for public emergency rescues. Further exploration of its potential is merited.
4.Measurement of related predictive parameters of osteoporotic hip fracture based on three-dimensional CT reconstruction technique and its clinical significance
Zhaoman SHI ; Minfei QIANG ; Xiaoyang JIA ; Kun ZHANG ; Yanxi CHEN
Chinese Journal of Orthopaedics 2021;41(15):1025-1032
Objective:To analyze the application value of three-dimensional computed tomography (3-D CT) reconstruction technique in the evaluation of related predictive parameters of osteoporotic hip fractures.Methods:From February 2014 to March 2019, 106 patients with hip fracture who underwent dual-energy X-ray bone density test of T≤ -2.5 SD on the hip were analyzed retrospectively. There were 58 males and 48 females; Age 73.50±5.59 years old (range, 65-88 years old); Height 170.12±7.43 cm (range, 152-187 cm); Weight (69.26±11.85) kg (range, 37-94 kg); Body mass index 23.60±2.37 kg/m 2 (range, 18.3-28.9 kg/m 2); There were 32 cases of femoral neck fractures, 68 cases of intertrochanteric fractures and 6 cases of subtrochanteric fractures. Anatomic parameters of the hip were the cortical thickness index (CTI), hip axis length (HAL), and femoral offset (FO). The above-mentioned predictive parameters of the hip fractures were measured based on X-ray and 3-D CT reconstruction images. Comparison of the two methods were analyzed using paired t test, liner Pearson analysis, and Bland-Altman analysis. Pearson analysis was used to evaluate correlation between CTI, HAL, and FO and T value. Results:106 cases were compared and analyzed with the measured values of X-ray and 3-D CT reconstruction images according to the preset measurement scheme. The mean value of CTI measured by conventional X-ray measurement method was 0.31±0.05, and the mean value of CTI measured by 3-D CT reconstruction images was 0.31±0.05. The result was not statistically significant ( t=0.938, P=0.35). The mean values of HAL, FO measured by conventional X-ray measurement method were 123.35±12.74 mm, 43.99±2.81 mm, and the mean values of HAL, FO measured by 3-D CT reconstruction images were 121.11±14.51 mm, 40.73±3.11 mm. The results were statistically different ( t=2.578, 18.502; all P< 0.05). The Bland-Altman results showed that there was no difference in the consistency of the two measurement methods for CTI while the measurement results of HAL, FO were quite different. CTI and HAL showed strong correlations with the T scores respectively ( r=0.784, -0.748; P< 0.001). Conclusion:Based on 3-D CT reconstruction technique, accurate measurement of related predictive parameters of osteoporotic hip fractures can be realized, which provides theoretical basis for the evaluation of osteoporotic hip fractures in the elderly and the formulation of accurate rehabilitation treatment plan.
5.A primary study on construction of urban unmanned aerial vehicle emergency blood distribution system
Qiang LI ; Fangmin GE ; Huqiang TANG ; Shifang YU ; Huaping ZHOU ; Azhong LI ; Minfei YANG ; Hang YU ; Hai Min ZHANG ; Xu WANG ; Wei HU ; Mao ZHANG
Chinese Journal of Emergency Medicine 2021;30(8):1026-1032
Objective:To explore the feasibility and effectiveness of the construction of urban unmanned aerial vehicle (UAV) blood distribution system, and to provide a novel way for the distribution of emergency blood.Methods:The study was completed in Hangzhou from April 2019 to January 2021, and the main participants were from the Second Affiliated Hospital of Zhejiang University School of Medicine, Zhejiang Province Blood Center and Hangzhou Fast Ant Network Technology Co., Ltd. Firstly, an unmanned aircraft delivery system was built for urban emergency blood and a special blood storage box for drones were developed. The drone was used to deliver blood products from Zhejiang Province Blood Center to Binjiang Campus, the Second Affiliated Hospital of Zhejiang University School of Medicine, and the following indicators were obtained: (1) flight time of the drone blood delivery; (2) real-time temperature of blood products during transportation; (3) Baidu map software was used to measure the blood delivery time of road traffic, which was compared with the flight time of the drone.Results:The urban drone blood delivery system consists of intelligent logistics drones, cryogenic blood storage tanks, unmanned logistics hub stations, and cloud-based operation control platforms. The drone route distance from Zhejiang Provincial Blood Center to Binjiang Campus, the Second Affiliated Hospital of Zhejiang University School of Medicine was 2.36±0.06 km, and the ground distance was 5.8 km, with 27 flights from April 12, 2019 to January 29, 2021, and the drone flight time was, shorter than the road travel time for a round trip [(6.37±0.35) min vs. (17.00±1.94) min]. At different time points of the day, UAV blood delivery could save 15.98-4.28 min, with an average saving of 10.62±1.87 min. Conclusions:Urban UAV blood delivery systems have the advantages of being fast, unaffected by ground traffic conditions, and can ensure the safety of blood products during transportation, and are worthy of further exploration.
6.Application of three-dimensional morphological measurement in treatment of displaced intra-articular calcaneal fractures in the elderly
Xiong WANG ; Minfei QIANG ; Yanxi CHEN ; Kun ZHANG ; Xiaoyang JIA
Chinese Journal of Trauma 2020;36(6):520-525
Objective:To investigate the application value of three-dimensional morphological measurement in the treatment of displaced intra-articular calcaneal fractures in the elderly.Methods:A retrospective case series study was conducted to analyze the clinical data of 44 patients with displaced intra-articular calcaneal fractures admitted to East Hospital Affiliated to Tongji University from January 2015 to January 2018. There were 33 males and 11 females, aged 60-88 years (mean, 67.2 years). According to Sanders classification, 35 patients were with type II fractures and 9 with type III fractures. All patients were evaluated with digital technology and received open reduction and internal fixation. The operation time, intraoperative blood loss, intraoperative fluoroscopy frequency and complications were recorded. Three-dimensional morphological parameters of calcaneal fractures were compared before and at latest follow-up, including horizontal length of the calcaneus, height of the posterior articular facet, height and length of the anterior process, Gissane angle, and B?hler angle. The visual analogue scale (VAS) and American Orthopedic Foot and Ankle Society (AOFAS) ankle-hind foot function score were also compared.Results:All patients were followed up for 12-30 months (mean, 17.1 months). There were 31 patients with posterior articular facet depression more than 2 mm, and 13 patients showed the back shift of the whole or part of posterior articular facet more than 3 mm and varying degree of fracture of the upper or lateral wall part of calcaneus body. The operative time was 55-105 minutes (mean, 85.1 minutes). The intraoperative blood loss was 30-130 ml (mean, 74.9 ml). The intraoperative fluoroscopy frequency was 5-8 times (mean, 6.5 times). During the operation, the internal fixation was not changed. Two patients suffered from skin incision infection after operation. At latest follow-up, the horizontal length of the calcaneus, height of the posterior articular facet, Gissane angle and B?hler angle were significantly improved from that before operation [(76.9±4.1)mm vs. (75.5±5.2)mm, (24.2±2.1)mm vs. (22.5±2.9)mm, (29.0±6.2)° vs. (18.3±5.5)°, (124.8±7.2)° vs. (107.6±8.5)°, respectively] ( P<0.01). No significance was found in the height and length of the anterior process ( P>0.05). At latest follow-up, the VAS and AOFAS ankle-hind foot function score were also significantly improved compared to preoperation [(1.1±0.9)points vs. (4.4±0.9)points, (86.4±6.2)points vs. (49.9±6.3)points, respectively] ( P<0.01). AOFAS ankle-hind foot function score was excellent in 13 patients, good in 26, fair in 5, with the excellent and good rate of 87%. Conclusion:Three-dimensional morphological measurement can fully evaluate the damage of calcaneal fractures and provide data reference for the preoperative planning of open reduction and internal fixation in the elderly, so as to restore the calcaneus structure, relieve pain and improve ankle function.
7. The treatment of pilon fractures with a single medial locking plate and lag screwsbased on computer-assisted pre-opera-tion plan
Minfei QIANG ; Kun ZHANG ; Yanxi CHEN ; Xiaoyang JIA ; Song CHEN ; Shuguang WANG ; Xiong WANG
Chinese Journal of Orthopaedics 2019;39(9):543-549
Objective:
evaluate the efficacy of a single medial locking plate and lag screws based on computer-assisted pre-operation plan (CAPP) for the treatment of pilon fractures.
Methods:
Between 2013 and 2016, data of 27 patients with pilon fractures who were treated using a single medial locking and lag screws based on CAPP were retrospectively analyzed. All the cas-es were AO/OTA 43-C type pilon fractures. According to the Rüedi-Allgöwer classification, there were 5 cases of type Ⅱ and 22 cases of type Ⅲ. Among 27 patients, 19 patients had fibula fracture. CAPP was performed for all fractures, including simulated re-duction, virtual surgery, and implantation of internal fixation. The time of CAPP, intraoperative realization of preoperative plan, op-eration time, intraoperative blood loss, and pre- and post-operative range of motion of ankle were recorded. Functional outcomes at final follow up were assessed using American Orthopedic Foot and Ankle Society (AOFAS) ankle hindfoot scale, visual analogue scale (VAS).
Results:
The mean time of CAPP was 25.8 minutes (range, 14-30 minutes). The average operating time was 138.5 minutes. The average intraoperative blood loss was 225.9 ml. All the twenty-seven patients were followed up for an average period of 18.6 months. The average AOFAS score, VAS score at the final follow-up was 82.9, 2.7 points respectively, which was signifi-cantly improved compared with those before operation (
8.Effects of heating intravenous fluid infusion and blood transfusion based on guidelines in sever trauma patients with hypothermia
Minfei YANG ; Yuwei WANG ; Yue ZHAN ; Fang CHEN ; Pengyuan CHEN ; Huanhuan ZHANG
Chinese Journal of Emergency Medicine 2018;27(5):492-498
Objective To explore the effects of heating intravenous fluid infusion and blood transfusion based on guidelines in severe trauma patients with hypothermia. Methods A total of 40 severe trauma patients with hypothermia admitted from July 2014 to December 2015 were enrolled as the control group treated with routine measures to maintain the body temperature at normothermia by such as electrical heating blanket; other 40 severe casualties with hypothermia admitted from January 2016 to July 2017 were recruited as the warming up group treated with heating intravenous fluid infusion and blood transfusion by hot water bath in addition to the routine measures for keeping body temperature at normothermia. The differences in core body temperature, prothrombin time, activated partial thromboplastin time, incidence of shivering and mortality rate were compared between the two groups. Results There was statistically signifi cant difference in core body temperature at 0.5 h, 1.0 h, 1.5 h, 3.0 h between the two groups (P<0.05). Though the prothrombin time and shivering were improved after warming up in both groups, and there were significant differences in prothrombin time at 3.0 h after warming up and the incidence of shivering between two groups(P<0.05).There was no signifi cant difference in mean arterial pressure at all seven intervals between two groups. Conclusion The heating intravenous fl uid infusion and blood transfusion had remarkable effects to prevent hypothermia, improves blood coagulation and reduced the incidence of shivering to provide more simple and convenient warming up intervention for clinical practice.
9.Efficacy evaluation of early debridement implant removal for infection after internal fixation of tibial fracture
Qinghui HAN ; Kun ZHANG ; Yanxi CHEN ; Minfei QIANG ; Xiaoyang JIA ; Xiaoying TANG
Chinese Journal of Trauma 2018;34(11):995-1000
Objective To compare the efficacy of early and delayed removal of debridement implant for infection after internal fixation of tibial fracture.Methods A retrospective case control study was conducted on the clinical data of 27 patients with tibial fractures who received plate or screw internal fixation admitted to the East Hospital Affiliated to Tongji University from March 2005 to September 2016.There were 21 males and six females,aged 18-81 years [(41.6 ± 14.3)years].According to the treatment methods,the patients were divided into the delayed implant removal group (Group A,10 patients) and the early implant removal group (Group B,17 patients).Group A was given debridement and anti infection treatment followed by continuous dressing change,and the implant was removed after the fractures were healed.Group B was given debridement and implant removal after one month of anti infection treatment and continuous dressing change when the infection was not clearly controlled.Patients with stable fracture ends were given only negative pressure closed drainage (VSD),and those with instable fracture ends were given external fixation and VSD.The time from infection to implant removal,the time of infection control,the fracture nonunion rate,the chronic bone infection rate,the knee joint function score of the American Hospital for Special Surgery (HSS),and the American Orthopedic Foot and Ankle Society (AOFAS) ankle hindfoot scale were compared between the two groups.Results All patients were followed up for 13-47 months,with the average of 28.4 months.There were significant differences between Group A and Group B in terms of the time from infection to implant removal [(49.9 17.1) weeks ∶ (19.3 ± 9.2) weeks],the time of infection control [(85.3 ±78.3)days∶ (6.3 ±2.8)days],fracture nonunion rate (30% ∶ 0),and the chronic osteomyelitis incidence (30% ∶ 0) (all P <0.05).No significant differences were found in HSS knee joint function score and AOFAS ankle hindfoot scale between the two groups (both P > 0.05).Conclusion For patients with postoperative infection after internal fixation for tibial fracture,early thorough debridement and implant removal can quickly control the infection and reduce the incidence of nonunion and osteomyelitis.
10.Morphological study of tibial plateau based on three-dimensional computed tomography image and its clinical significance
Yijie ZHANG ; Yanxi CHEN ; Kun ZHANG ; Minfei QIANG ; Xiaoyang JIA ; Haobo LI ; Yuchen JIANG
Chinese Journal of Trauma 2017;33(1):63-68
Objective To investigate the three-dimensional morphological characteristics of tibial plateau based on CT image post-processing technique and analyze its significance in preoperative planning of tibial plateau fractures.Methods Multi-slice spiral CT data of 98 humans (56 males and 42 females) with normal tibial plateau and 30 patients (15 males and 15 females) with tibial plateau fractures were extracted.Morphological measurements of the tibial plateau were achieved by means of a three-dimensional measurement method based on points,lines and surfaces.Differences in threedimensional parameters between genders in normal tibial plateau and differences between normal tibial plateau and tibial plateau fractures were analyzed.Results Differences of males and females were significant in width of tibial plateau [(73.2 ± 3.7) mm,(65.5 ± 3.7) mm],anteroposterior dimension of medial tibial plateau [(39.8 ± 3.5) mm,(34.8 ± 2.6) mm] and anteroposterior dimension of lateral tibial plateau [(34.0 ± 3.3) mm,(29.8 ± 3 5) mm] (P < 0.05),but not in varus inclination of tibial plateau [(3.19 ± 1.98) °,(3.16 ± 1.89) °],medial plateau posterior slope [(7.31 ± 3.04) °,(8.16 ± 2.46)°] and lateral plateau posterior slope [(5.23 ±2.35)°,(5.60 ±2.55)°] (P >0.05).Above parameters in three-dimensional morphological measurements of tibibial plateau fractures varied compared to the normal reference value (P < 0.05).Intraclass correlation coefficient (ICC) for intra-observe and inter-observer agreement in normal tibial plateau measurement was excellent.Conclusions Present research provides a series of scientific and objective data for preoperative planning of tibial plateau fractures.Measurements of tibial plateau can assist the evaluation of reduction of tibial plateau fractures.

Result Analysis
Print
Save
E-mail