1.Effects of pressure controlled ventilation-volume guaranteed mode on intraoperative pulmonary ventilation and postoperative pulmonary complications in elderly patients undergoing thoracoscopic lobectomy
Juan ZHAO ; Huimin WU ; Yi LIU ; Xinlong CUI ; Rihong BAI ; Meiping LI
Cancer Research and Clinic 2023;35(3):211-216
Objective:To explore the effects of pressure controlled ventilation-volume guaranteed (PCV-VG) mode on intraoperative pulmonary ventilation and postoperative pulmonary complications (PPC) in elderly patients undergoing thoracoscopic lobectomy.Methods:Sixty patients of American Society of Anesthesiologists (ASA) classification Ⅱor Ⅲ, aged 65-80 years old, with body mass index (BMI) 18-30 kg/m 2, received thoracoscopic lobectomy under general anesthesia from November 2021 to June 2022 in the Second Hospital of Shanxi Medical University were recruited. The patients were divided into PCV-VG and volume-controlled ventilation (VCV) groups using the randomized number table method, with 30 patients in each group. The ventilatory parameters of two-lung ventilation were set to respiratory rate (RR) at 10-12 breaths/min, with a tidal volume (VT) of 8 ml/kg (ideal body weight). The ventilatory parameters of one-lung ventilation (OLV) were set at 12-16 breaths/min, with a VT of 6 ml/kg (IBW). The peak airway pressure (Ppeak), plateau airway pressure (Pplat), driving pressure (ΔP), dynamic lung compliance (Cdyn), end-tidal carbon dioxide (ETCO 2), heart rate (HR), mean arterial pressure (MAP), partial pressure of oxygen (PaO 2) and partial pressure of carbon dioxide (PaCO 2) were obtained at 1 min before OLV (T 0), 30 min after OLV (T 1) and 60 min after OLV (T 2). The incidence and severity of PPC, chest tube duration time and postoperative hospital stay time were recorded. Results:The Ppeak, Pplat and ΔP were higher and Cdyn was lower in both groups at T 1-T 2 than at T 0 (all P<0.001). The Ppeak, Pplat and ΔP were higher and Cdyn was lower in PCV-VG group than in VCV group (all P<0.05). There were no statistical differences in HR, MAP, ETCO 2, PaO 2 and PaCO 2 between the two groups (all P > 0.05). There were no statistical differences in the incidence of PPC [43.3% (13/30) vs. 30.0% (9/30)] and chest tube duration time [(4.4±0.9) d vs. (4.2±1.2) d] between VCV group and PCV-VG group (all P>0.05). Compared with VCV group, the proportion of patients with ≥grade 2 PPC was lower in PCV-VG group [10.0% (3/30) vs. 36.7% (11/30), χ2=5.96, P<0.05]. The postoperative hospital stay time in PCV-VG group was shorter than that in VCV group [(6.4±1.3) d vs. (8.0±1.9) d, t = 4.85, P<0.05]. Conclusions:PCV-VG mode can effectively reduce the severity of PPC, shorten the postoperative hospital stay time and improve the prognosis in elderly patients undergoing thoracoscopic lobectomy.
2.The 495th case: young female-hyperandrogenemia-severe insulin resistance
Yunying CUI ; Ruizhi JIAJUE ; Meiping CHEN ; Lin LU ; Miao YU ; Linjie WANG
Chinese Journal of Internal Medicine 2022;61(6):703-707
A 22-year-old female has complained of hirsutism, acanthosis nigricans, enlarged clitoris, and menstrual disorders since puberty. Laboratory examinations revealed hyperandrogenemia. Severe insulin resistance and diabetes were found during hospitalization in our hospital. She was diagnosed with type A insulin resistance syndrome finally. After treatment with metformin, the acanthosis nigricans was significantly relieved, blood glucose was controlled satisfactorily, and the menstrual cycle was restored.
3.The application value of virtual reality technology in the surgical treatment of coronary artery fistula and abnormal origin of coronary artery
QIU Hailong ; ZHUANG Jian ; CEN Jianzheng ; HUANG Meiping ; GAO Qiang ; CHEN Jimei ; WEN Shusheng ; XU Gang ; CUI Hujun ; CAI Xiaowei
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2019;26(3):217-221
Objective To evaluate the application value of virtual reality (VR) technology in the surgical treatment of coronary artery fistula (CAF) and abnormal origin of coronary artery (AOOCA). Methods From January 2014 to June 2018, with the assistance of virtual reality technology, 4 patients with CAF and 4 patients with AOOCA in the Department of Cardiac Surgery of our hospital underwent treatment method deciding and operation details planning. In the CAF patients, there was 1 male and 3 females and they were 8 years, 16 years, 62 years, and 65 years, respectively. In the AOOCA patients, there was 1 male and 3 females at age of 4-month, 2 years, 14 years, and 29 years, respectively. Results The virtual heart models in all 8 patients were well matched with the real heart. The spatial structure information of CAF/AOOCA and surroundings can be intuitively and fully shown by virtual reality technology in all patients. All of the 4 CAF patients repaired coronary artery incision, including 2 patients with autologous pericardium patch and 2 patients with direct suture. Of the 4 AOOCA patients, 3 underwent coronary directly transplantation but 1 underwent Takeuchi surgery. And 2 had mitral valve plasty at the same time. All the operations were completed successfully, with good recovery and no serious complications. Among the 4 CAF patients, 3 had no residual fistula, and 1 had minor residual fistula. Coronary arteries were all unobstructed in 4 patients of AOOCA; moderate and severe mitral regurgitation in 2 patients were significantly reduced after surgery. Conclusion VR allows doctors to understand the spatial structure information of CAF/AOOCA and surroundings before the operation, and assists them to make accurate treatment decisions and develop detailed surgical plans before the operation, ensuring its safety. Its clinical application value is significant.
4.A preliminary discussion on the application experience of virtual reality technology and mixed reality technology in complex congenital heart disease surgery
Yong ZHANG ; Jianzheng CEN ; Shusheng WEN ; Meiping HUANG ; Wenda GU ; Jimei CHEN ; Gang XU ; Xiaobing LIU ; Hujun CUI ; Xiaohua LI ; Jian ZHUANG
Chinese Journal of Thoracic and Cardiovascular Surgery 2019;35(1):22-24
Objective To analyze the application of virtual reality technology and mixed reality techniques in our hospital before and during intraoperative evaluation of complicated congenital heart diseases .Methods Methods Retrospectively ana-lyze the clinical treatment, surgical decision-making, intraoperative and early prognosis of 11 children with complicated congen-ital heart disease assessed by virtual reality technology and mixed reality techniques.The time of operation was 34-121 min, CPB time was 26-101 min, the clamping time of aorta was 18-56 min.There was no operative death.Results All 11cases were assessed by virtual reality technology and mixed reality technology before surgery .Personalized surgical strategies were made based on the evaluation results.All patients had undergone operations successfully.Compared with traditional surgical methods, fewer surgical incisions and shorter operation time were required.And it improved the surgical results.Conclusion Virtual reality technology and mixed reality technology have a great advantage in preoperative and intraoperative evaluation of complex congenital heart diseases.They can optimize surgical strategies, shorten operation time, and reduce surgical trauma. They are worthy of further promotion and application in clinical practice.
5.Accuracy evaluation of cardiac models of cases with complex congenital heart disease printed by domestic 3D printers
Hailong QIU ; Jian ZHUANG ; Jianzheng CEN ; Jimei CHEN ; Shusheng WEN ; Gang XU ; Hujun CUI ; Meiping HUANG ; Qiang GAO ; Xiaowei CAI
Chinese Journal of Thoracic and Cardiovascular Surgery 2019;35(4):205-207
Objective To evaluate the accuracy of 3D models of patients with complex congenital heart disease(CHD) printed by domestic 3D priuters based on cardiac CT data.Methods From April 2018 to June 2018,our hospital used domestic 3D printers to print the hearts of 50 patients with complex CHD.The median age of the patients was 24 months(1 month to 61 years),and the diseases included pulmonary atresia,right ventricular double outlet and transposition of aorta.3 measurement sites(150 in total) were selected for each patient.Pearson correlation coefficient calculation,paired t test and Bland-Altman analysis were performed.Results Pearson correlation coefficient is 0.997.The difference of the measured value of CT-model was tested for normality.P was 0.2 of the D test.The Q-Q graph showed that the data point and the theoretical line were highly overlapped.The mean difference was (-0.07 ± 0.67) mm,P =0.196.In Bland-Altman analysis,the consistency boundary value interval of the difference was(-1.29 mm,1.16 mm) between which there were 143/150(95.33%) points.Conclusion 3D models of patients with complex CHD printed by domestic 3D printers based on cardiac CT data have good accuracy.
6.3D printing technology-based diagnosis and therapeutic pattern in complex congenital heart disease: single center experience in 40 patients
Wenda GU ; Jianzheng CEN ; Meiping HUANG ; Shusheng WEN ; Gang XU ; Hujun CUI ; Yun TENG ; Yong ZHANG ; Jimei CHEN ; Jian ZHUANG
Chinese Journal of Thoracic and Cardiovascular Surgery 2018;34(8):449-452
Objective To evaluate the value of three-dimensional(3 D) printing technique in the diagnosis and treatment of complex congenital heart disease(CHD).Methods From March 2016 to February 2018,40 patients with complex CHD underwent heart CT scanning.The CT images were imported to Standard Template Library(STL) files after 3D reconstruction and then exported for 3D printing.The 3D printed models were then used for decision making and navigation during surgery.Results Thirty patients were indicated for surgical operation.Three patients underwent single ventricular repair,and biventricular repair were operated on 27 patients.The 3D printed models were quite in accordance with the actual anatomical findings in all the patients.And all the procedures carried on were exactly same as planned based on 3D printed model.Conclusion The 3D printing may help improve the diagnosis and treatment level in complex CHD.
7.Chinese Society of Allergy Guidelines for Diagnosis and Treatment of Allergic Rhinitis.
Lei CHENG ; Jianjun CHEN ; Qingling FU ; Shaoheng HE ; Huabin LI ; Zheng LIU ; Guolin TAN ; Zezhang TAO ; Dehui WANG ; Weiping WEN ; Rui XU ; Yu XU ; Qintai YANG ; Chonghua ZHANG ; Gehua ZHANG ; Ruxin ZHANG ; Yuan ZHANG ; Bing ZHOU ; Dongdong ZHU ; Luquan CHEN ; Xinyan CUI ; Yuqin DENG ; Zhiqiang GUO ; Zhenxiao HUANG ; Zizhen HUANG ; Houyong LI ; Jingyun LI ; Wenting LI ; Yanqing LI ; Lin XI ; Hongfei LOU ; Meiping LU ; Yuhui OUYANG ; Wendan SHI ; Xiaoyao TAO ; Huiqin TIAN ; Chengshuo WANG ; Min WANG ; Nan WANG ; Xiangdong WANG ; Hui XIE ; Shaoqing YU ; Renwu ZHAO ; Ming ZHENG ; Han ZHOU ; Luping ZHU ; Luo ZHANG
Allergy, Asthma & Immunology Research 2018;10(4):300-353
Allergic rhinitis (AR) is a global health problem that causes major illnesses and disabilities worldwide. Epidemiologic studies have demonstrated that the prevalence of AR has increased progressively over the last few decades in more developed countries and currently affects up to 40% of the population worldwide. Likewise, a rising trend of AR has also been observed over the last 2–3 decades in developing countries including China, with the prevalence of AR varying widely in these countries. A survey of self-reported AR over a 6-year period in the general Chinese adult population reported that the standardized prevalence of adult AR increased from 11.1% in 2005 to 17.6% in 2011. An increasing number of original articles and imporclinical trials on the epidemiology, pathophysiologic mechanisms, diagnosis, management and comorbidities of AR in Chinese subjects have been published in international peer-reviewed journals over the past 2 decades, and substantially added to our understanding of this disease as a global problem. Although guidelines for the diagnosis and treatment of AR in Chinese subjects have also been published, they have not been translated into English and therefore not generally accessible for reference to non-Chinese speaking international medical communities. Moreover, methods for the diagnosis and treatment of AR in China have not been standardized entirely and some patients are still treated according to regional preferences. Thus, the present guidelines have been developed by the Chinese Society of Allergy to be accessible to both national and international medical communities involved in the management of AR patients. These guidelines have been prepared in line with existing international guidelines to provide evidence-based recommendations for the diagnosis and management of AR in China.
Adult
;
Asian Continental Ancestry Group*
;
China
;
Comorbidity
;
Developed Countries
;
Developing Countries
;
Diagnosis*
;
Epidemiologic Studies
;
Epidemiology
;
Global Health
;
Humans
;
Hypersensitivity*
;
Prevalence
;
Rhinitis, Allergic*
8.Comparison of diagnostic value of TIRADS, BSRTC, BRAFV600E mutation detection and their combined use in differentiating thyroid nodules
Yuzhi ZHANG ; Ting XU ; Xiao LI ; Haiyan GONG ; Dai CUI ; Xiaoyun LIU ; Huanhuan CHEN ; Lin JIANG ; Xinhua YE ; Qing YAO ; Zhihong ZHANG ; Meiping SHEN ; Yu DUAN ; Tao YANG ; Xiaohong WU
Chinese Journal of Endocrinology and Metabolism 2016;32(5):380-385
Objective To compare the diagnostic efficiency of the thyroid imaging reporting and data system (TIRADS), the Bethesda system for reporting thyroid cytopathology(BSRTC) and BRAFV600E detection, and their combined use in the differentiation between benign and malignant thyroid nodules. Methods One hundred and twenty eight patients with 128 thyroid nodules who were scheduled for ultrasound-guided fine-needle aspiration biopsy (FNAB) were recruited for the study. All of them underwent ultrasound, fine-needle aspiration cytology(FNAC) examination, and BRAFV600E detection. TIRADS and BSRTC systems were adopted to judge the ultrasound and FNAC results. The receiver operating characteristic curve was established to assess the diagnostic value of each method. Results The sensitivity, specificity, and AUC of TIRADS were 74. 3%, 84. 5%, and 0. 794, respectively. BSRTC had higher specificity(98. 3%) and equal sensitivity compared to TIRADS. The sensitivity, specificity, and AUC of BRAFV600E detection were the highest ones among the three methods. Combinations of different methods could increase the diagnostic sensitivity and accuracy. The combination of FNAC and BRAFV600E detection significantly increased the diagnostic efficiency(AUC=0. 984), with sensitivity 98. 6% and specificity 98. 3%. Conclusions The diagnostic value of BRAFV600E detection in the differentiation of benign and malignant thyroid nodules is better than both TIRADS and BSRTC, and the combination of FNAC and BRAFV600E detection reaches the best diagnostic efficiency.
9.Establishment of double antibody sandwich ELISA for pro-gastrin releasing peptide and its application
Zhenyu CHU ; Xiaolin ZHOU ; Zhenwei XUE ; Meiping CUI ; Suqin LIN ; Ruihua LI
Journal of Medical Postgraduates 2015;(1):70-73
Objective The value of pro-gastrin releasing peptide ( PGRP) which is the tumor marker of small cell lung canc-er has become a hot topic in recent years .The research was to build a new enzyme-linked immune sorbent assay ( ELISA) method ai-ming at detecting the concentration of PGRP in patients′serum. Methods We utilized synthetic PGRP epitopes for the screening of the monoclonal antibodies , labeled the screened monoclonal antibodies with horseradish peroxidase by modified sodium iodide method , and then established double antibody sandwich ELISA which could be used to detect the serum concentrations of PGRP in cancer pa -tients. Results We successfully screened E 12 mAb which could be served as the coating antibody and ED 1 mAb as the labeled anti-body.The standard antibody density range of new ELISA was 33 pg/mL~1.7 ×104 pg/mL.The comparison experiments between our method and the commercially available ELISA kit showed no significant difference ( P>0.05).The specificity of our method was 50%, and the sensitivity was 100%, while IBL kit was 92.2% and 100% respectively. Conclusion New ELISA can be used to detect the serum PGRP concentration in patients with small cell lung cancer .
10.Feasibility of tube current modulation based on the chest circumference in coronary CT angiography
Yanhai CUI ; Meiping HUANG ; Jinglei LI ; Hui LIU ; Changhong LIANG ; Junhui ZHENG
Chinese Journal of Radiological Medicine and Protection 2014;34(10):783-786
Objective To establish a function model to modulate the tube current according to the chest circumference at Coronary CTA scan,and to evaluate the feasibility of using the function model individually.Methods Sixty-eight consecutive patients who underwent thoracic scan with automatic current modulation were studied to establish a function model of tube current and chest circumference.The other 64 consecutive patients underwent coronary CTA scan using the new function model.The image quality was scored,and the noise,tube current and radiation dose were recorded and statistically evaluated.Results The POW function model was the best one to adjust tuber current to the chest circumference (R2 =0.691,P < 0.05).The mean image quality score,noise,tube current,radiation dose (CTDIvol) and dose-length product (DLP) were (3.38±0.72) scores,(31.02 ±3.97) HU,(390.63± 89.30) mA,(34.83±10.72) mGy,(751.67 ±175.16) mGy·cm,respectively.Conclusions Tube current modulation based on the chest circumference would be feasible to reduce the radiation dose individually in coronary CT angiography.


Result Analysis
Print
Save
E-mail