1.Antidepressant Mechanisms of Polygalae Radix: A Review
Liming LIU ; Shuaijun PENG ; Pan SU ; Yucheng LI
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(5):300-309
Depression is a high-incidence mental disorder with complex causes and multifaceted pathogenic mechanisms. Its pathogenesis has not yet been fully elucidated, which has hindered the development of novel and highly effective antidepressant drugs. This condition severely affects human physical and mental health while imposing a significant socio-economic burden. At present, several hypotheses exist regarding the pathogenesis of depression, including monoamine neurotransmitter imbalances, neurotrophic factor deficiencies, neural plasticity impairments, glutamate dysregulation, neuroinflammatory disorders, gut microbiota imbalances, and mitochondrial autophagy dysfunction. Currently, most clinical antidepressants are monoamine neurotransmitter reuptake inhibitors. Although they exhibit certain therapeutic effects, they are associated with significant drawbacks, such as severe adverse reactions and poor patient compliance. In contrast, traditional Chinese medicine (TCM), characterized by its multi-targeted effects, mild efficacy, and minimal side effects, has demonstrated significant advantages in the treatment of depression. Chinese medicine Polygalae Radix possesses the functions of calming the mind, enhancing cognitive functions, harmonizing the heart and kidneys, and dispelling phlegm to open orifices. It is often included in compound prescriptions for the clinical treatment of depression. Based on current hypotheses regarding the pathogenesis of depression, this paper systematically reviews research progress on the antidepressant mechanisms of Polygalae Radix from multiple perspectives, including its active components, its use in herbal pairings, and its inclusion in TCM compound prescriptions. This review aims to provide a scientific basis for the clinical application of Polygalae Radix in antidepressant therapy and to serve as a reference for the modernization of its antidepressant research.
2.Clinical and CT radiomics features for predicting microsatellite instability-high status of gastric cancer
Pengchao ZHAN ; Liming LI ; Dongbo LYU ; Chenglong LUO ; Zhiwei HU ; Pan LIANG ; Jianbo GAO
Chinese Journal of Medical Imaging Technology 2024;40(1):77-82
Objective To observe the value of clinical and CT radiomics features for predicting microsatellite instability-high(MSI-H)status of gastric cancer.Methods Totally 150 gastric cancer patients including 30 cases of MSI-H positive and 120 cases of MSI-H negative were enrolled and divided into training set(n=105)or validation set(n=45)at the ratio of 7∶3.Based on abdominal vein phase enhanced CT images,lesions radiomics features were extracted and screened,and radiomics scores(Radscore)was calculated.Clinical data and Radscores were compared between MSI-H positive and negative patients in training set and validation set.Based on clinical factors and Radscores being significant different between MSI-H positive and negative ones,clinical model,CT radiomics model and clinical-CT radiomics combination model were constructed,and their predictive value for MSI-H status of gastric cancer were observed.Results Significant differences of tumor location and Radscore were found between MSI-H positive and negative patients in both training and validation sets(all P<0.05).The area under the curve(AUC)of clinical model,CT radiomics model and combination model for evaluating MSI-H status of gastric cancer in training set was 0.760,0.799 and 0.864,respectively,of that in validation set was 0.735,0.812 and 0.849,respectively.AUC of clinical-CT radiomics combination model was greater than that of the other 2 single models(all P<0.05).Conclusion Clinical-CT radiomics combination model based on tumor location and Radscore could effectively predict MSI-H status of gastric cancer.
3.Comparative effectiveness research of different testing methods in functional quality inspection of precision surgical instruments
Fenglian CHE ; Liming QIAN ; Weiwei CHEN ; Lele ZHENG ; Yu CHEN ; Huiyuan PAN
China Medical Equipment 2024;21(3):129-132
Objective:To compare the testing effects of different testing methods in the functional inspection of precision surgical scissors and needle holders.Methods:By consulting relevant literature and professional books,three testing methods and materials for precision surgical scissors and needle holders were selected.The cutting performance of the precision surgical scissors were tested by gauze cloth,cotton wool,and silicone film method in the Interlock surgical instrument testing set.The clamping performance of precision needle holder was tested by using light,needle clips,and thread clamping method in the Interlock surgical instrument testing set.100 pieces of precision surgical scissors and needle holders which were qualified for cleaning and disinfection in the hospital were selected for effectiveness testing,and a self-made satisfaction questionnaire to investigate the satisfaction of surgeons with the use of instruments.Results:After 100 precision surgical scissors tested using three methods of gauze,cotton wool,and silicone film,the qualified number of cutting performance was 94,76,and 58,respectively,the difference was statistically significant(x2=36.526,P<0.05).The satisfaction rate of surgeons with the use of precision surgical scissors passed the silicone film test was the highest at 100%,followed by cotton wool cloth at 82.0%,and the gauze method at the worst at 67.0%,the difference was statistically significant(x2=48.439,P<0.05).After 100 precision needle holders were tested by using three methods of light irradiation,needle clamping,and wire clamping,the qualified number of clamping performance was 96,78,and 62,respectively,the difference was statistically significant(x2=38.160,P<0.05).The satisfaction rate of surgeons with the precision needle holders passed the clamp line test was the highest at 100.0%,followed by the clamp needle at 79.0%,and the worst under light at 62.0%,the difference was statistically significant(x2=57.705,P<0.05).Conclusion:The function and quality of precision surgical scissors and needle holders tested by the test objects in Interlock Surgical Instrument Test Suite can objectively and accurately reflect the functional status of surgical scissors and needle holders,provide reference for regular maintenance and upkeep of instruments,and ensure safe use of instruments.
4.Progress and practice of objective measurement of physical behaviors in large-scale cohort research
Yuanyuan CHEN ; Yalei KE ; Jun LYU ; Dianjianyi SUN ; Lang PAN ; Pei PEI ; Huaidong DU ; Junshi CHEN ; Zhengming CHEN ; Liming LI ; Doherty AIDEN ; Canqing YU
Chinese Journal of Epidemiology 2024;45(1):35-40
Due to the limited reliability of traditional self-completed questionnaire, the accuracy of measurement of physical behaviors (physical activity, sedentary behavior and sleep) is not high. With the development of technology, wearable devices (e.g. accelerometer) can be used for more accurate measurement of physical behaviors and have great application potential in large-scale research. However, the data of objective measurement of physical behaviors from large-scale cohort research in Asian populations is still limited. Between August 2020 and December 2021, the 3 rd resurvey of China Kadoorie Biobank (CKB) project used Axivity AX3 wrist triaxial accelerometer to collect the data of participants' daily activity and sleep status. A total of 20 370 participants from 10 study areas were included in the study, in whom 65.2% were women, and the age was (65.4±9.1) years. The participants' physical activity level varied greatly in different study areas. The objective measurement of participants' physical behaviors in CKB project has provided valuable resources for the description of 24-hour patterns of physical behaviors and evaluation of the health effect of physical activity, sedentary behavior and sleep as well as their association with diseases in the elderly in China.
5.Distribution and influencing factors of lipoprotein (a) levels in non-arteriosclerotic cardiovascular disease population in China
Yalei KE ; Lang PAN ; Jun LYU ; Dianjianyi SUN ; Pei PEI ; Yiping CHEN ; Ling YANG ; Huaidong DU ; Robert CLARKE ; Junshi CHEN ; Zhengming CHEN ; Xiao ZHANG ; Ting CHEN ; Runqin LI ; Litong QI ; Liming LI ; Canqing YU
Chinese Journal of Epidemiology 2024;45(6):779-786
Objective:To describe the distribution of lipoprotein (a) [Lp(a)] levels in non-arteriosclerotic cardiovascular disease (ASCVD) population in China and explore its influencing factors.Methods:This study was based on a nested case-control study in the CKB study measured plasma biomarkers. Lp(a) levels was measured using a polyclonal antibody-based turbidimetric assay certified by the reference laboratory and ≥75.0 nmol/L defined as high Lp(a). Multiple logistic regression model was used to examine the factors related to Lp(a) levels.Results:Among the 5 870 non-ASCVD population included in the analysis, Lp(a) levels showed a right-skewed distribution, with a M ( Q1, Q3) of 17.5 (8.8, 43.5) nmol/L. The multiple logistic regression analysis found that female was associated with high Lp(a) ( OR=1.23, 95% CI: 1.05-1.43). The risk of increased Lp(a) levels in subjects with abdominal obesity was significantly reduced ( OR=0.68, 95% CI: 0.52-0.89). As TC, LDL-C, apolipoprotein A1(Apo A1), and apolipoprotein B(Apo B) levels increased, the risk of high Lp(a) increased, with OR (95% CI) for each elevated group was 2.40 (1.76-3.24), 2.68 (1.36-4.93), 1.29 (1.03-1.61), and 1.65 (1.27-2.13), respectively. The risk of high Lp(a) was reduced in the HDL-C lowering group with an OR (95% CI) of 0.76 (0.61-0.94). In contrast, an increase in TG levels and the ratio of Apo A1/Apo B(Apo A1/B) was negatively correlated with the risk of high Lp(a), with OR (95% CI) of 0.73 (0.60-0.89) for elevated triglyceride group, and OR (95% CI) of 0.60 (0.50-0.72) for the Apo A1/B ratio increase group (linear trend test P≤0.001 except for Apo A1). However, no correlation was found between Lp(a) levels and lifestyle factors such as diet, smoking, and physical activity. Conclusions:Lp(a) levels were associated with sex and abdominal obesity, but less with lifestyle behaviors.
6.Multicenter expert recommendations on interventional valve-in-valve technology for mitral bioprosthetic valve destruction in China
Haibo ZHANG ; Xiangbin PAN ; Yingqiang GUO ; Lai WEI ; Jian YANG ; Daxin ZHOU ; Yongjian WU ; Xu MENG ; Liming LIU
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2024;31(08):1090-1095
Mitral valve replacement is one of the most common heart valve surgeries in China. In recent years, with the increase in degenerative valve diseases, older patients, and the progress of anti-calcification technology of biological valves, the proportion of mitral valve biological valve replacement has been increasing year by year. After the damage of traditional mitral valve biological valves, re-operation of valve replacement with thoracotomy is required. However, the adhesion between the heart and sternum, as well as the damage caused by cardiopulmonary bypass and cardiac arrest, can cause significant trauma to elderly patients and those with multiple organ dysfunction, leading to increased mortality and complication rates. In recent years, interventional valve surgery, especially transcatheter valve-in-valve surgery, has developed rapidly. This procedure can correct the damaged mitral valve function without stopping the heart, but there are still many differences between its technical process and conventional aortic valve replacement surgery. Therefore, organizing and writing multicenter expert recommendations on the technical process of transcatheter valve-in-valve surgery for damaged mitral valve biological valves is of great significance for the training and promotion of this technology.
7.Application of radial collateral artery perforator flap on reconstruction of moderate-severe thumb web contracture
Fang YU ; Juyu TANG ; Panfeng WU ; Lei ZENG ; Liming QING ; Yongbing XIAO ; Ding PAN
Chinese Journal of Plastic Surgery 2024;40(9):929-935
Objective:To explore the efficiency of radial collateral artery perforator flap to reconstruct defects of thumb web contracture release.Methods:The data of patients with moderate to severe thumb web contracture treated with radial collateral artery perforator flap from September 2018 to September 2022 in Department of Orthopedics-Hand Microsurgery of Xiangya Hospital, Central South University were analyzed retrospectively. A skin flap with the radial collateral artery perforating point as the center and the line connecting the deltoid muscle insertion point and the apex of the humeral lateral condyle as the axis were designed before surgery. During the operation, the skin scar in the thumb web area was first removed, and the contracted tissues such as deep fascia and muscles were loosened. Then, a skin flap was harvested along the design line and transferred to the recipient site. After vascular and nerve anastomosis under a microscope, the incision was intermittently sutured and a drainage tube was placed. The blood flow of the flap and complication were monitored closely. In the last follow-up, the distance and angle of thumb web were observed; the appearance, sensory recovery (excellent, good, moderate, and poor) and the hand function (S0 level to S4 level represented feeling no recovery to complete recovery) were evaluated.Results:A total of 8 patients were included, including 7 males and 1 female, aged 23-56 years (average of 40.3 years old). The distance of thumb web was 20-38 mm (average 26.9 mm), and the angle was 22°-36° (average 27.4°) before surgery. Five hands were classified as severe thumb web contracture, and 3 hands were moderate. The sizes of perforator flap were from 5.5 cm×3.5 cm-13.0 cm×6.5 cm. Seven flaps survived uneventfully and venous congestion occurred in 1 flap. After exploration, the flap survived completely. Primary healing of wounds occurred in the donor and recipient areas. Postoperative follow-up ranged from 6 months to 2.5 years (average 13.6 months). In the last follow-up, the distance of thumb web was 48-63 mm (average 57.1 mm), and the angle was 40°-52° (average 44.8°) post-operation. Thumb web function evaluation: excellent in 5 cases and good in 3 cases. All patients were satisfied with the thumb web. Sensory recovered to S3 in 3 cases, S2 in 4 cases and S1 in 1 case. The donor site healed well, leaving scars. There was no radial nerve damage, and elbow joint movement was normal.Conclusion:The radial collateral artery perforator flap has reliable blood supply, relatively simple operation and the appearance and function of thumb web restored well postoperatively. The application of radial collateral artery perforator flap is an effective procedure to repair the thumb web contracture.
8.Epidemiological characteristics of hemorrhoids in a healthy physical examination population in China
Chenghua GUO ; Xiaoyu CHE ; Zhi LIN ; Shan CAI ; Guozhen LIU ; Lang PAN ; Jun LV ; Liming LI ; Sailimai MAN ; Bo WANG ; Canqing YU
Journal of Peking University(Health Sciences) 2024;56(5):815-819
Objective:To describe the epidemiological distribution of hemorrhoids in a physical exami-nation population in China,which could provide evidence for precision prevention and early intervention of hemorrhoids.Methods:Chinese subjects over 18 years of age who underwent a physical examination in a nationwide chain of physical examination centers in 2018 were studied in a cross-sectional design,which collected information by a questionnaire and physical examination results from each subject.The epidemiological distribution of hemorrhoids was described using Logistic models.The gender-,age-,and region-detection rates of hemorrhoids were standardized to the Sixth National Population Census of the People's Republic of China(2010).Results:A total of 2 940 295 adult subjects were included in the study,of whom the average age was(41.7±14.0)years,and 52.6%were females.The standardized detection rate of hemorrhoids was higher for females(43.7%)than that for males(17.7%;P<0.001)in this study.In the females,the age distribution of hemorrhoids was inverted U-shaped,with the highest standardized detection rate of hemorrhoids in the age group of 30-39 years(63.5%).In the males,the standardized detection rate of hemorrhoids increased along with age,with the highest percentage of 17.2%in the age group of 50-59 years,and the standardized detection rate of hemorrhoids in the age group of 60 and above decreased slightly(P<0.001 for trend test).The participants with hypertension had a higher standardized detection rate of hemorrhoids than those with normal blood pressure in both males and females(P<0.001).The standardized detection rate of hemorrhoids showed a positive corre-lation with body mass index(P<0.001 for trend test in males).Conclusion:The detection rate of hemorrhoids varied to gender,age,obesity,and hypertension status,which could help to identify the risk factors and the high-risk sub-groups,and hence to strengthen health education and early detection accordingly,which could eventually reduce the incidence of hemorrhoids and improve the quality of life and health in the Chinese population.This study was conducted in a physical examination population,and the conclusions of this study should be extrapolated with caution.
9.Application of radial collateral artery perforator flap on reconstruction of moderate-severe thumb web contracture
Fang YU ; Juyu TANG ; Panfeng WU ; Lei ZENG ; Liming QING ; Yongbing XIAO ; Ding PAN
Chinese Journal of Plastic Surgery 2024;40(9):929-935
Objective:To explore the efficiency of radial collateral artery perforator flap to reconstruct defects of thumb web contracture release.Methods:The data of patients with moderate to severe thumb web contracture treated with radial collateral artery perforator flap from September 2018 to September 2022 in Department of Orthopedics-Hand Microsurgery of Xiangya Hospital, Central South University were analyzed retrospectively. A skin flap with the radial collateral artery perforating point as the center and the line connecting the deltoid muscle insertion point and the apex of the humeral lateral condyle as the axis were designed before surgery. During the operation, the skin scar in the thumb web area was first removed, and the contracted tissues such as deep fascia and muscles were loosened. Then, a skin flap was harvested along the design line and transferred to the recipient site. After vascular and nerve anastomosis under a microscope, the incision was intermittently sutured and a drainage tube was placed. The blood flow of the flap and complication were monitored closely. In the last follow-up, the distance and angle of thumb web were observed; the appearance, sensory recovery (excellent, good, moderate, and poor) and the hand function (S0 level to S4 level represented feeling no recovery to complete recovery) were evaluated.Results:A total of 8 patients were included, including 7 males and 1 female, aged 23-56 years (average of 40.3 years old). The distance of thumb web was 20-38 mm (average 26.9 mm), and the angle was 22°-36° (average 27.4°) before surgery. Five hands were classified as severe thumb web contracture, and 3 hands were moderate. The sizes of perforator flap were from 5.5 cm×3.5 cm-13.0 cm×6.5 cm. Seven flaps survived uneventfully and venous congestion occurred in 1 flap. After exploration, the flap survived completely. Primary healing of wounds occurred in the donor and recipient areas. Postoperative follow-up ranged from 6 months to 2.5 years (average 13.6 months). In the last follow-up, the distance of thumb web was 48-63 mm (average 57.1 mm), and the angle was 40°-52° (average 44.8°) post-operation. Thumb web function evaluation: excellent in 5 cases and good in 3 cases. All patients were satisfied with the thumb web. Sensory recovered to S3 in 3 cases, S2 in 4 cases and S1 in 1 case. The donor site healed well, leaving scars. There was no radial nerve damage, and elbow joint movement was normal.Conclusion:The radial collateral artery perforator flap has reliable blood supply, relatively simple operation and the appearance and function of thumb web restored well postoperatively. The application of radial collateral artery perforator flap is an effective procedure to repair the thumb web contracture.
10.Structural Design and Analysis of Portable Intelligent Wheelchair for Knee Rehabilitation
Dongmei MA ; Jingyan WANG ; Liming PAN ; Jinshi CHEN ; Tianyue CHU ; Lei HUANG ; Baoyue YIN ; Xin XU
Chinese Journal of Medical Instrumentation 2024;48(4):445-450
Objective In order to address the issues of inconvenience,high medical costs,and lack of universality associated with traditional knee rehabilitation equipment,a portable intelligent wheelchair for knee rehabilitation was designed in this study.Methods Based on the analysis of the knee joint's structure and rehabilitation mechanisms,an electric pushrod-driven rehabilitation institution was developed.A multi-functional module was designed with a modular approach,and the control of the wheelchair body and each functional module was implemented using an STM32 single-chip microcomputer.A three-dimensional model was established using SolidWorks software.In conjunction with Adams and Ansys simulation software,kinematic and static analyses were conducted on the knee joint rehabilitation institution and its core components.A prototype was constructed to verify the equipment's actual performance.Results According to the prototype testing,the actual range of motion for the knee joint swing rod is 15.1°~88.9°,the angular speed of the swing rod ranges from-7.9 to 8.1°/s,the angular acceleration of the swing rod varies from-4.2 to 1.6°/s2,the thrust range of the electric pushrod is-82.6 to 153.1 N,and the maximum displacement of the load pedal is approximately 1.7 mm,with the leg support exhibiting a maximum deformation of about 1.5 mm.Conclusion The intelligent knee joint rehabilitation wheelchair meets the designed functions and its actual performance aligns with the design criteria,thus validating the rationality and feasibility of the structural design.

Result Analysis
Print
Save
E-mail