1.Evaluation of early effectiveness of local infiltration anesthesia with compound betamethasone in total knee arthroplasty.
Yuhang ZHENG ; Yang LI ; Hua TIAN
Chinese Journal of Reparative and Reconstructive Surgery 2024;38(1):9-14
OBJECTIVE:
To evaluate the early effectiveness of local infiltration anesthesia (LIA) with compound betamethasone in total knee arthroplasty (TKA).
METHODS:
The clinical data of 102 patients with knee osteoarthritis who were treated by TKA and met the selection criteria between May 2022 and March 2023 were retrospectively analyzed. They were divided into control group and study group according to whether LIA preparation was added with compound betamethasone, with 51 cases in each group. There was no significant difference of baseline data, such as age, gender, body mass index, operative side, preoperative range of motion (ROM), Knee Society Score (KSS), white blood cell (WBC), and hematocrit between the two groups ( P>0.05). The intraoperative total blood loss and hidden blood loss were recorded, and WBC was recorded on the 1st, 2nd, and 3rd days after operation. Pain was assessed by visual analogue scale (VAS) score on the 1st, 2nd, and 3rd days after operation and morphine intake milligrames equivalent within 48 hours after operation. Passive ROM, maximum extension and flexion angles of knee joint were measured on the 3rd day after operation; the early postoperative complications were recorded.
RESULTS:
There was no significant difference in total blood loss and hidden blood loss between the two groups ( P>0.05). The postoperative pain levels in both groups were relatively mild, and there was no significant difference in VAS scores in the first 3 days after operation and in morphine intake milligrams equivalent within 48 hours after operation between the two groups ( P>0.05). The WBC in the first 3 days after operation was significantly improved in both groups ( P<0.05). The WBC in the study group was significantly higher than that in the control group on the 1st and 2nd days after operation ( P<0.05), but there was no significant difference between the two groups on the 3rd day after operation ( P>0.05). On the 3rd day after operation, the maximum extension angle of knee joint in the study group was smaller than that in the control group, while the maximum flexion angle and passive ROM of knee joint in the study group were larger than those in the control group, and the differences were significant ( P<0.05). There were 6 cases of fever and 17 cases of deep venous thrombosis in the control group, and 1 case and 14 cases in the study group, respectively. There was no poor wound healing and periprosthetic joint infection in the two groups, and there was no significant difference in the incidence of complications between the two groups ( P>0.05).
CONCLUSION
The application of compound betamethasone in LIA during TKA is a safe and optimal strategy to promote the early postoperative rehabilitation of patients.
Humans
;
Arthroplasty, Replacement, Knee
;
Anesthesia, Local
;
Retrospective Studies
;
Treatment Outcome
;
Knee Joint/surgery*
;
Osteoarthritis, Knee/surgery*
;
Blood Loss, Surgical
;
Morphine
2.Research Progress in Application of Patient-Reported Outcome Measures in Total Knee Arthroplasty.
Zi-Yang DONG ; Yang LI ; Hua TIAN
Acta Academiae Medicinae Sinicae 2023;45(2):327-333
To summarize the clinical application of patient-reported outcome measures (PROM) in total knee arthroplasty (TKA) and provide reference for the application of PROM in perioperative evaluation of the patients receiving TKA,we reviewed the recent studies about the application of PROM in TKA and analyzed the contents and application characteristics of the PROM.The common PROM in TKA,such as the Western Ontario and McMaster Universities Osteoarthritis Index,Oxford Knee Score,and Forgotten Joint Score,principally focus on patients' subjective feelings about pain,function and other aspects of their knees.However,they have diverse ranges of application and each of them has their own advantages and disadvantages.There is a variety of PROM applied in TKA,which makes it challenging to select the proper measurement for evaluation.The PROM in TKA remains to be improved for broader use.
Humans
;
Arthroplasty, Replacement, Knee
;
Knee Joint/surgery*
;
Osteoarthritis, Knee/surgery*
;
Treatment Outcome
;
Patient Reported Outcome Measures
3.Musculoskeletal multibody dynamics investigation for the different medial-lateral installation position of the femoral component in unicompartmental knee arthroplasty.
Jiaxuan REN ; Zhenxian CHEN ; Jing ZHANG ; Yongchang GAO ; Feng QIAO ; Zhongmin JIN
Journal of Biomedical Engineering 2023;40(3):508-514
The surgical installation accuracy of the components in unicompartmental knee arthroplasty (UKA) is an important factor affecting the joint function and the implant life. Taking the ratio of the medial-lateral position of the femoral component relative to the tibial insert (a/A) as a parameter, and considering nine installation conditions of the femoral component, this study established the musculoskeletal multibody dynamics models of UKA to simulate the patients' walking gait, and investigated the influences of the medial-lateral installation positions of the femoral component in UKA on the contact force, joint motion and ligament force of the knee joint. The results showed that, with the increase of a/A ratio, the medial contact force of the UKA implant was decreased and the lateral contact force of the cartilage was increased; the varus rotation, external rotation and posterior translation of the knee joint were increased; and the anterior cruciate ligament force, posterior cruciate ligament force and medial collateral ligament force were decreased. The medial-lateral installation positions of the femoral component in UKA had little effect on knee flexion-extension movement and lateral collateral ligament force. When the a/A ratio was less than or equalled to 0.375, the femoral component collided with the tibia. In order to prevent the overload on the medial implant and lateral cartilage, the excessive ligament force, and the collision between the femoral component and the tibia, it is suggested that the a/A ratio should be controlled within the range of 0.427-0.688 when the femoral component is installed in UKA. This study provides a reference for the accurate installation of the femoral component in UKA.
Humans
;
Arthroplasty, Replacement, Knee
;
Knee Joint/surgery*
;
Knee Prosthesis
;
Gait
;
Rotation
4.A comparative study of short-term effectiveness of "SkyWalker" robot-assisted versus traditional total knee arthroplasty.
Haoming AN ; Hangyu PING ; Haifeng LI ; Wei CHAI
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(4):404-409
OBJECTIVE:
To compare the short-term effectiveness of "SkyWalker" robot-assisted total knee arthroplasty (TKA) and traditional TKA.
METHODS:
A clinical data of 54 patients (54 knees) with TKA who met the selection criteria between January 2022 and March 2022 was retrospectively analyzed. Among them, 27 cases underwent traditional TKA (traditional operation group) and 27 cases underwent "SkyWalker" robot-assisted TKA (robot-assisted operation group). There was no significant difference between the two groups ( P>0.05) in terms of gender, age, body mass index, osteoarthritis side, disease duration, and preoperative Knee Society Score (KSS), Western Ontario and McMaster University Osteoarthritis Index (WOMAC), visual analogue scale (VAS) score, hip-knee-ankle angle (HKA), lateral distal femoral angle (LDFA), medial proximal tibial angle (MPTA), and posterior proximal tibial angle (PPTA). The operative time, intraoperative bleeding volume, surgery-related complications, the KSS, WOMAC, and VAS scores before operation and at 6 months after operation, and Forgotten Joint Score (FJS) at 6 months after operation were recorded. X-ray films were taken to review the prosthesis position and measure HKA, LDFA, MPTA, and PPTA. The differences of the clinical and imaging indicators between before and after operation were calculated and statistically analyzed.
RESULTS:
The operations were completed successfully in both groups. There was no significant difference in the operative time and intraoperative bleeding volume between the two groups ( P>0.05). After operation, 1 case of incision nonunion and 1 case of heart failure occurred in the traditional operation group, while no surgery-related complications occurred in the robotic-assisted operation group. The incidences of surgical complications were 7.4% (2/27) in the traditional operation group and 0 (0/27) in the robotic-assisted operation group, with no significant difference ( P=0.491). Patients in both groups were followed up 6 months. KSS score, WOMAC score, VAS score, and ROM significantly improved in both groups at 6 months after operation when compared with preoperative ones ( P<0.05). There was no significant difference between the two groups ( P>0.05) in the differences between the pre- and post-operative values of the clinical indicators and FJS scores at 6 months after operation. X-ray films showed that the lower extremity force lines of the patients improved and the knee prostheses were in good position. Except for LDFA in the robot-assisted operation group, HKA, LDFA, MPTA, and PPTA significantly improved in both groups at 6 months after operation when compared with the preoperative ones ( P<0.05). There was no significant difference between the two groups in the differences between the pre- and post-operative values of the radiological indicators ( P>0.05).
CONCLUSION
The "SkyWalker" robot-assisted TKA is one of the effective methods for the treatment of knee osteoarthritis and had good short-term effectiveness. But the long-term effectiveness needs to be further studied.
Humans
;
Arthroplasty, Replacement, Knee/methods*
;
Knee Joint/surgery*
;
Knee Prosthesis
;
Osteoarthritis, Knee/surgery*
;
Retrospective Studies
;
Robotics
;
Treatment Outcome
5.Osteotomy of non-core weight-bearing area of the lateral tibial plateau, reduction, and internal fixation in treatment of tibial plateau fractures involving posterolateral column collapse.
Xuan PEI ; Guodong WANG ; Shenglong QIAN ; Yipeng CHENG ; Zhixun FANG ; Xi KE ; Ximing LIU
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(4):410-416
OBJECTIVE:
To investigate the effectiveness of osteotomy of non-core weight-bearing area of the lateral tibial plateau, reduction, and internal fixation in the treatment of tibial plateau fractures involving posterolateral column collapse.
METHODS:
A clinical data of 23 patients with tibial plateau fractures involving posterolateral column collapse, who had undergone osteotomy of non-core weight-bearing area of the lateral tibial plateau, reduction, and internal fixation between January 2015 and June 2021, was retrospectively analyzed. There were 14 males and 9 females with an average age of 42.6 years ranging from 26 to 62 years. The causes of injury included traffic accident in 16 cases, falling from height in 5 cases, and other injuries in 2 cases. According to Schatzker classification, there were 15 cases of type Ⅴ and 8 cases of type Ⅵ. The time from injury to operation was 4-8 days with an average of 5.9 days. The operation time, intraoperative blood loss, fracture healing time, and complications were recorded. The depth of articular surface collapse of posterolateral column and posterior inclination angle (PSA) of the tibial plateau were compared before operation and at 2 days and 6 months after operation; fracture reduction of tibial plateau fracture was evaluated by Rasmussen anatomic score. The recovery of knee function was evaluated by Hospital for Special Surgery (HSS) score at 2 days and 6 months after operation.
RESULTS:
All 23 patients were completed the operation successfully. The operation time was 120-195 minutes, with an average of 152.8 minutes; the intraoperative blood loss was 50-175 mL, with an average of 109.5 mL. All patients were followed up 12-24 months, with an average of 16.7 months. One patient had superficial wound infection after operation, and the incision healed after dressing change; primary healing of incision of other patients was obtained. The fracture healing time was 12-18 weeks, with an average of 13.7 weeks. No failure of internal fixation, varus and valgus deformity of the knee joint, and instability of the knee joint was found at last follow-up. One patient developed joint stiffness and the range of motion of the knee joint was 10°-100°; the range of motion of the knee joint of other patients was 0°-125°. At 2 days and 6 months after operation, the depth of articular surface collapse of posterolateral column, PSA, and Rasmussen anatomic scores significantly improved when compared with those before operation ( P<0.05). There was no significant difference between the two postoperative time points ( P>0.05). The HSS score at 6 months after operation was significantly higher than that at 2 days after operation ( P<0.05).
CONCLUSION
For tibial plateau fractures involving posterolateral column collapse, reduction and internal fixation through osteotomy of non-core weight-bearing area of the lateral tibial plateau has the advantages of fully expose the posterolateral column fragment, good articular surface reduction, sufficient bone grafting, and fewer postoperative complications. It is beneficial to restore knee joint function and can be widely used in clinic.
Male
;
Female
;
Humans
;
Adult
;
Retrospective Studies
;
Blood Loss, Surgical
;
Tibial Plateau Fractures
;
Treatment Outcome
;
Bone Plates
;
Tibial Fractures/surgery*
;
Knee Joint
;
Fracture Fixation, Internal
;
Osteotomy
;
Weight-Bearing
6.Effects of moxibustion on the ultrastructure of synovial cells of knee joint and serum cytokines in adjuvant arthritis rats.
Hui LIANG ; Yan ZHU ; Min ZHANG ; Lin-Kang BAI ; Wen-Juan WANG ; Chen ZHAO
Chinese Acupuncture & Moxibustion 2023;43(3):317-321
OBJECTIVE:
To observe the effects of moxibustion on the ultrastructure of synovial cells of knee joint and serum cytokines in adjuvant arthritis (AA) rats, and to explore the potential mechanism of moxibustion in treatment of rheumatoid arthritis.
METHODS:
Forty-five Wistar male rats were randomly divided into a normal group, a model group and a moxibustion group, with 15 rats in each group. In the model group and the moxibustion group, the AA model was replicated under wind, cold and humid environment and by injection with complete freund's adjuvant. In the moxibustion group, moxibustion at "Zusanli" (ST 36) and "Shenshu" (BL 23) was used, 20 min each time, once daily, for consecutive 21 days. In the normal group and the model group, no intervention was processed. The scores of the knee joint swelling degree (JSD) and arthritis index (AI) were compared among groups. The ultrastructure of synovial cells of knee joint were observed under transmission electron microscope (TEM). The levels of serum cytokines such as tumor necrosis factor-α (TNF-α), interieukin (IL)-1β, IL-6 and IL-10 were detected using ELISA method.
RESULTS:
Compared with the normal group, JSD and AI scores, the levels of TNF-α, IL-1β and IL-6 were increased (P<0.01), while IL-10 was reduced (P<0.01) in the model group after intervention. JSD and AI scores, and the levels of TNF-α, IL-1β and IL-6 were lower (P<0.05, P<0.01), while the level of IL-10 was higher (P<0.01) in the moxibustion group compared with the model group. Compared with the normal group, the ultrastructure of synovial cell was obviously damaged in the model group, and the damage was attenuated in the moxibustion group compared with the model group.
CONCLUSION
Moxibustion can reduce the symptoms of arthritis in AA rats, which may be related to the improvement of the ultrastructure of synovial cells and the regulation of cytokines.
Male
;
Rats
;
Animals
;
Cytokines
;
Interleukin-10
;
Arthritis, Experimental
;
Tumor Necrosis Factor-alpha
;
Interleukin-6
;
Moxibustion
;
Rats, Wistar
;
Knee Joint
7.Long-term results of synovectomy in total knee arthroplasty: a prospective, randomized controlled trial.
Weinan ZENG ; Zeping YU ; Simeng WANG ; Anjing CHEN ; Yiping ZENG ; Qingjun YANG ; Yujuan LI ; Qi LI ; Zongke ZHOU
Chinese Medical Journal 2023;136(1):73-81
BACKGROUND:
Synovectomy has been introduced into total knee arthroplasty (TKA) with the aim of relieving pain and inflammation of the synovium. However, there are no long-term, comparative data to evaluate the effect of synovectomy in TKA. This study was aimed at assessing pain, function, and complications in patients undergoing synovectomy during TKA for osteoarthritis (OA) at long-term follow-up.
METHODS:
This was a prospective randomized controlled trial of 42 consecutive patients who underwent staged bilateral TKA. Patients undergoing the first-side TKA were allocated to receive TKA with or without synovectomy followed by a 3-month washout period and crossover to the other strategy for the opposite-side TKA. The overall efficacy of both strategies was evaluated by determination of blood loss, the Knee Society score (KSS), and knee inflammation conditions during a 3-month postoperative period. The postoperative pain, range of motion (ROM), and complications were sequentially evaluated to compare the two groups until 10 years after surgery.
RESULTS:
At the 10-year follow-up, both groups had a similarly significantly improved ROM (114.88 ± 9.84° vs. 114.02 ± 9.43°, t = 0.221, P = 0.815) and pain relief with no differences between the two groups (1.0 [1.0] vs. 1.0 [1.5], U = 789.500, P = 0.613). Similar changes in total blood loss, KSS, and knee inflammation were found in both groups during 3 months postoperatively ( P > 0.05). Additionally, there was no significant difference regarding complications and satisfaction between the two groups ( P > 0.05).
CONCLUSIONS:
Synovectomy in conjunction with TKA for primary OA does not seem to provide any benefit regarding postoperative pain, ROM, and satisfaction during a 10-year follow-up. In addition, it may not result in more blood loss and increased incidence of long-term complications. Based on our long-term findings, it should not be performed routinely.
TRIAL REGISTRATION
Chinese Clinical Trial Registry, ChiCTR-INR-16008245; https://www.chictr.org.cn/showproj.aspx?proj=13334 .
Humans
;
Arthroplasty, Replacement, Knee/methods*
;
Synovectomy/methods*
;
Osteoarthritis, Knee/surgery*
;
Prospective Studies
;
Pain, Postoperative
;
Inflammation/etiology*
;
Range of Motion, Articular
;
Knee Joint/surgery*
;
Treatment Outcome
;
Knee Prosthesis/adverse effects*
8.The short-term outcomes of non-contact low frequency ultrasonic debridement in treating periprosthetic joint infections:a prospective single-arm clinical study.
Bao Chao JI ; Abudusaimi AIMAITI ; Fei WANG ; Jing Jie ZHENG ; Li CAO
Chinese Journal of Surgery 2023;61(2):129-137
Objective: To evaluate the short-term outcomes of non-contact low-frequency ultrasonic debridement in treating periprosthetic joint infections(PJI). Methods: The clinical data of patients with PJI who met the eligibility criteria and were treated with non-contact low-frequency ultrasonic debridement from August 2021 to January 2022 at the Department of Orthopaedics,the First Affiliated Hospital of Xinjiang Medical University were prospectively analyzed. PJI was defined according to the modified Musculoskeletal Infection Society criteria in 2016. After mechanical debridement,an 8-mm handheld non-contact low-frequency ultrasound probe was used for ultrasonic debridement in the whole surgical area at a frequency of (25±5)kHz and power of 90% for 5 minutes. Each ultrasound lasted 10 seconds with 3-second intervals. The probe was repeatedly sonicated among all soft tissue,bone interface and metal prosthesis surface(patients underwent debridement,antibiotics and implant retention (DAIR)) in the surgical area. The femoral canal of the hip joint,the distal femoral canal and the posterior capsule of the knee were fully sonicated with a special right-angle probe. Before and after ultrasonic debridement,20 ml of liquid was extracted from each operation area and injected into aerobic and anaerobic culture bottles,respectively,for pathogen culture. Harris hip score and Hospital for Special Surgery (HSS) score were used to evaluate clinical function. Treatment failure was defined as the recurrence of infection in the same joint. The patients were routinely followed up in the outpatient clinic at 1,3,and 6 months postoperatively and then annually with a deadline of August 2022. The paired t-test,rank sum,Mann-Whitney U or χ2 test was used to compare the observed data,and rates among multiple groups were compared using the Bonferroni approach. Results: A total of 45 patients were included in the study,including 21 men and 24 women with age of (65.8±15.2)years(range: 20 to 80 years) and body mass index of (29.3±4.2)kg/m2(range: 20.2 to 38.5 kg/m2). Twenty-eight patients (18 hips and 10 knees) underwent one-stage revision,and 17 cases (5 hips and 12 knees) underwent DAIR. Three of the patients (6.7%) had recurrent infections during follow-up. There were no intraoperative complications related to ultrasonic debridement (neurovascular and muscle injury,poor wound healing and fat liquefaction). Seventeen patients who received DAIR were followed for a median(M(IQR)) of 9(3) months,and two relapsed 3 weeks and 3 months post-operation,respectively. In addition,28 patients who underwent one-stage revision were followed for a median of 9(2) months,and one of the patients (3.6%,1/28) had a recurrence 6 months post-operation. The culture-positive rate of preoperative aspiration was 47.6% (20/42). The data of intraoperative soft tissue culture was 86.7% (39/45). The culture-positive rate of wound liquid before ultrasonic debridement was 46.7% (21/45). And the culture-positive rate after ultrasonic debridement was (75.6% (34/45)). After sonication,the culture-positive rate of explanted prostheses was 88.9% (40/45). There was a significant difference in culture-positive rates among all five cultures (χ2=35.483,P<0.01). Further pairwise comparison showed that the culture-positive rate of wound liquid after ultrasonic debridement was higher than that before ultrasonic debridement (χ2=7.901,P=0.005) but was not significantly different from the positive rates of other cultures (all P>0.05). The median number of colonies 24 hours after ultrasonic debridement(2 240 (1 310) CFU/ml,range: 310 to 3 140 CFU/ml) was significantly higher than that before debridement(450 (550) CFU/ml,range: 10 to 910 CFU/ml) (U=43, P=0.017). The post-operative Harris ((78.6±4.2)points,range:70.5 to 85.3 points) and HSS scores((76.4±4.8)points,range: 68.5 to 84.3 points) were significantly higher than the preoperative scores((46.0±9.8)points,range: 27.5 to 64.3 points;and (45.5±10.3)points,range: 27.6 to 63.1 points) (t=-14.6,t=-12.7;both P<0.01). Conclusions: Non-contact low-frequency ultrasonic debridement can increase the culture-positive rate and lead to a favorable short-term outcome. In addition,no complications are associated with using this new technique to treat PJI.
Female
;
Humans
;
Male
;
Anti-Bacterial Agents
;
Debridement
;
Knee Joint
;
Orthopedic Procedures
;
Prospective Studies
;
Ultrasonics
9.Research on performance optimization method of human-machine physical interaction system considering exoskeleton wearing comfort.
Wenyao QI ; Yuwei YANG ; Zuyi ZHOU ; Jianchao GONG ; Pengyu CHEN
Journal of Biomedical Engineering 2023;40(1):118-124
In order to improve the wearing comfort and bearing effectiveness of the exoskeleton, based on the prototype and working mechanism analysis of a relaxation wearable system for knee exoskeleton robot, the static optimization synthesis and its method are studied. Firstly, based on the construction of the virtual prototype model of the system, a comprehensive wearable comfort evaluation index considering the factors such as stress, deformation and the proportion of stress nodes was constructed. Secondly, based on the static simulation and evaluation index of system virtual prototype, multi-objective genetic optimization and local optimization synthesis of armor layer topology were carried out. Finally, the model reconstruction simulation data confirmed that the system had good wearing comfort. Our study provides a theoretical basis for the bearing performance and prototype construction of the subsequent wearable system.
Humans
;
Exoskeleton Device
;
Computer Simulation
;
Emotions
;
Knee Joint
10.Early clinical application of Mako robot-assisted total knee arthroplasty in knee osteoarthritis.
China Journal of Orthopaedics and Traumatology 2023;36(2):133-139
OBJECTIVE:
To investigate the early efficacy of Mako robot-assisted total knee arthroplasty (TKA) in the treatment of knee osteoarthritis (KOA) and summarize the initial application experience.
METHODS:
Retrospective analysis of 73 patients with KOA treated with Mako robot-assisted TKA from June 2021 to December 2021. There were 16 males and 57 females, aged from 54 to 81 years old with an average of (67.8±6.6) years old. The hip knee and ankle angle (HKA), lateral distal femoral angle (LDFA), medial proximal tibial angle (MPTA), lateral femoral component angle (LFCA) and lateral tibial component angle (LTCA) were recorded and analyzed. WOMAC score and KSS were used to compare the functional recovery of patients preoperatively, 3 and 6 months postoperatively.
RESULTS:
All the 73 patients were successfully treated without serious complications such as vascular and nerve injury, and all the incisions healed well at stageⅠwithout infection. The patients were followed up from 4 to 11 months with an average of (7.0±2.7) months, and the satisfaction rate of the last follow-up was 90.41% (66/73). WOMAC scores were (23.1±5.4) at 3 months and (14.8±4.1) at 6 months postoperatively. KSS clinical scores were ( 76.1±4.0) at 3 months and (82.1±3.7) at 6 months postoperatively;KSS functional scores were (74.3±3.1) at 3 months and (78.6±2.1) at 6 months after operation. Postoperative imaging showed good position of the prosthesis, HKA angle was (178.5±2.1)°, LDFA was (91.2±1.8)°, MPTA was(89.9±1.5) °, LFCA was (7.6±3.1)°, LTCA was (88.2±1.1)°. The mechanical axis within ±3° in sixty cases(82.2%), and the mechanical axis within ±6° in all the patients.
CONCLUSION
Mako robot-assisted TKA is a safe and effective surgery in the treatment of knee osteoarthritis, which exhibited good efficacy in the correction of lower limb alignment, soft tissue balance and improvement of knee function. The long-term efficacy needs further follow-up observation.
Male
;
Female
;
Humans
;
Middle Aged
;
Aged
;
Aged, 80 and over
;
Arthroplasty, Replacement, Knee/methods*
;
Osteoarthritis, Knee/surgery*
;
Retrospective Studies
;
Robotics
;
Knee Joint/surgery*

Result Analysis
Print
Save
E-mail