1.Shexiang Tongxin Dropping Pills Ameliorate Dysfunction of Cardiac Microvascular Endothelial Cells in Rat Model of Heart Failure
Junkai YAO ; Shujuan GUO ; Mingyue HUANG ; Chun LI ; Yong WANG ; Wei WANG
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(16):87-95
		                        		
		                        			
		                        			ObjectiveTo study the mechanism by which Shexiang Tongxin dropping pills (STDP) ameliorate the dysfunction of coronary microvascular endothelial cells in the rat model of heart failure. MethodsThe heart failure model was established by ligation of the left anterior descending coronary artery in rats, which were then allocated into sham, model, STDP, and telmisartan (TLM) groups and treated for 21 days. The heart function was detected by echocardiography, and the levels of myocardial injury markers, nitric oxide (NO), endothelin-1 (ET1), and angiotensinⅡ (AngⅡ) were determined by enzyme-linked immunosorbent assay (ELISA). The protein levels of endothelial nitric oxide synthase (eNOS) and inducible nitric oxide synthase (iNOS) were determined by Western blot. The model of cardiac microvascular endothelial cell injury was established by AngⅡ induction and then treated with the STDP-containing serum (5%, 10%, and 20%) for 24 h. The levels of NO and ET1 were measured by ELISA. Western blot was employed to determine the protein levels of eNOS, iNOS, angiotensin-converting enzyme 2 (ACE2), and angiotensinⅡ receptor 2 (AT2). MLN-4760, an ACE2 inhibitor, was used to explore the mechanism underpinning the regulatory effect of STDP on the ACE2-AT2/MAS pathway. ResultsCompared with the sham group, the model group showed decreases in left ventricular ejection fraction (LVEF) and left ventricular fractional shortening (LVFS) (P<0.05), a decline in serum NO level, elevations in serum AngⅡ and ET1 levels, a reduction in p-eNOS/eNOS ratio, and up-regulation in iNOS expression (P<0.05). Compared with the model group, STDP increased LVEF, LVFS, and cardiac output (P<0.05), raised the level of NO and lowered the levels of AngⅡ and ET1 in the serum (P<0.05), increased the p-eNOS/eNOS value, and inhibited iNOS expression (P<0.05). Compared with the AngⅡ group, STDP increased the NO content and decreased the ET1 content in endothelial cells (P<0.05), increased the p-eNOS/eNOS ratio, and inhibited the iNOS expression (P<0.05). The ACE2 inhibitor MLN-4760 reversed the regulatory effects of STDP on p-eNOS, eNOS, and iNOS. ConclusionSTDP improves the cardiac function in the rat model of heart failure, enhances the synthesis and release of NO in cardiac microvascular endothelial cells, reduces AngⅡ and ET1 levels, and regulates the expression of p-eNOS and eNOS, thereby ameliorating the dysfunction of microvascular endothelial cells in heart failure. This mechanism is related to the upregulation of the expression of proteins in the ACE2-AT2/MAS pathway. 
		                        		
		                        		
		                        		
		                        	
2.Mechanism of Shexiang Tongxin Dripping Pills in Ameliorating AngⅡ-induced Vascular Smooth Muscle Cell Dysfunction
Yueyao HU ; Wei WANG ; Mingyue HUANG ; Shujuan GUO ; Junkai YAO
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(8):97-106
		                        		
		                        			
		                        			ObjectiveTo study the mechanism of Shexiang Tongxin Dripping pills-containing serum (STDP) in ameliorating angiotensinⅡ (AngⅡ)-induced cell phenotype transformation, proliferation, migration, and dysfunction of vascular smooth muscle cells. MethodsAn AngⅡ-induced proliferation and migration model of vascular smooth muscle cells was established. The cells were treated with STDP at 5%, 10%, and 20% for 24 h. The immunofluorescence assay was employed to detect the expression of α smooth muscle actin (α-SMA) and matrix metalloproteinase-2 (MMP-2). The cell-counting kit-8 (CCK-8) assay and 5-ethynyl-2'-deoxyuridine (EdU) staining were employed to detect the proliferation of vascular smooth muscle cells, and the scratch assay was employed to detect the migration of the cells. Western blot was employed to determine the expression levels of pathway proteins such as angiotensin-converting enzyme 2 (ACE2), angiotensin Ⅱ type 2 (AT2), angiotensin Ⅱ type 1 (AT1), as well as proliferation and migration proteins such as typeⅠ collagen (ColⅠ) and osteopontin (OPN). ResultsCompared with the model group, STDP increased the expression of α-SMA, reduced the expression of MMP-2, and inhibited the proliferation and migration of vascular smooth muscle cells (P<0.05). Furthermore, STDP up-regulated the expression levels of ACE2, AT2, and MAS1, while down-regulating the expression level of AT1, PCNA, ColⅠ, MMP-9, Rock1, Rock2, and SRF (P<0.05). Compared with the STDP group, the ACE2 inhibitor reversed the regulatory effects of STDP. ConclusionSTDP inhibits the phenotype transformation, proliferation, and migration of vascular smooth muscle cells and regulates the expression of cell proliferation and migration-related proteins to ameliorate the dysfunction of vascular smooth muscle cells. It exerts the effects by up-regulating the expression of proteins in the ACE2-AT2/MAS pathway and down-regulating the expression of proteins in the AT1-Rock signaling pathway. 
		                        		
		                        		
		                        		
		                        	
3.Efficacy and safety assessment of polyglycolic acid and hydroxypropyl methylcellulose for postoperative suturing in a distal pancreatectomy model
Junkai CHEN ; Yu DING ; Baozhi WANG ; Matsutani TETSUYUKI ; Xuewei YANG ; Fenghua ZHANG
Journal of Xi'an Jiaotong University(Medical Sciences) 2024;45(2):334-342
		                        		
		                        			
		                        			【Objective】 To explore the effectiveness and safety of polyglycolic acid (PGA) and hydroxypropyl methylcellulose (HPMC) composite materials in distal pancreatectomy postoperative suturing. 【Methods】 We selected 36 healthy adult beagles and divided them randomly into observation group and control group, with 18 distal pancreatectomy surgeries in each group. The observation group used PGA+HPMC composite materials for incision reinforcement while the control group used NEOVEIL for incision reinforcement. 3 days before surgery, 3 days after surgery, and before dissection, blood routine tests were performed on each group of experimental dogs. Observation periods of 2-week, 4-week and 8-week were set, and six animals at each observation point were evaluated for histological examination of heart, liver, spleen, lung, and kidney tissues, hard tissue slice pathological diagnosis, and safety evaluation. 【Results】 There was no significant difference between the observation group and the control group in the preoperative blood routine test. Repeated measures ANOVA results showed differences in the mean values of white blood cell count (WBC) ( F=14.875, P=0.001), mean corpuscular hemoglobin concentration (MCHC) (F=5.049,P=0.009), neutrophil percentage (Neu%) (F=4.794, P=0.011), red blood cell count (RBC) (F=6.591, P=0.002), hemoglobin (HGB) (F=8.154, P=0.001), hematocrit (HCT) (F=5.281, P=0.007), platelet count (PLT) (F=6.560, P=0.014), red blood cell distribution width coefficient of variation (RDW-CV) (F=33.950, P=0.039), or lymphocyte percentage (Lym%) (F=3.299, P=0.043) at different time points. However, the observation group and the control group did not differ, and the interaction between time and group had no significant effect on the above indicators, suggesting that both groups of dogs had inflammatory response or surgical stress. For the 8-week postoperative hard tissue pathological section score, there was no significant difference between the observation group and the control group in the inflammation and necrosis related score, fibrosis, repair or other related scores and total score (P>0.05). In the dissection at 8 weeks after surgery, no obvious damage to the heart, liver, spleen, lung, kidney, or other organs was found in both groups, nor was there any residual suture material, pancreatic fistula, or pancreatitis, indicating that the suture materials in both groups had been completely absorbed and metabolized, and the incision healed well without causing adverse effects on the visceral organs. 【Conclusion】 PGA and HPMC are effective and safe postoperative suture materials, with good biodegradability, biocompatibility, suture strength, and wound healing quality. They can be comparable to traditional absorbable reinforcement materials in distal pancreatectomy postoperative suturing, thus providing scientific basis for their clinical application.
		                        		
		                        		
		                        		
		                        	
4.Exploration of the Thinking of Syndrome Differentiation and Treatment "Treatment According to Disease Tendency" in Traditional Chinese Medicine from the Perspective of Holism and Constant Motion
Junkai WEN ; Shuyun WANG ; Jiamin GAO ; Wanli DENG
Journal of Traditional Chinese Medicine 2024;65(18):1854-1859
		                        		
		                        			
		                        			"Tendency of disease" is an important concept in the theory of traditional Chinese medicine (TCM). It was born out of and rooted in the thinking of "conducting by tendency" of ancient Chinese philosophy, meaning that the development and change of humans and nature have their own inevitable laws and dynamic tendencies. Based on the concept of holism and constant motion, the basic definition of "tendency", the origin of the idea, the influence factors and related concepts were analysed, to grasp the overall connection in the dynamic changes in space and time, and to find a scientific and comprehensive objective law of development. The "tendency" was regarded as dynamic forces in the complex system, when yin and yang harmonized, called normal tendency; when fail to keep normal, called disease tendency; the season have sequential tendency, the earth has geographical tendency, people have body tendency, medications have medical tendency, and pulse has pulse tendency. Then the "eight methods of treating tendency" were summed up as observing tendency, evaluating tendency, waiting for tendency, accumulating tendency, favoring tendency, counteracting tendency, preventing tendency, and borrowing tendency, and condenses the methodo-logical thinking of "treatment according to disease tendency", with a view to re-understanding the internal logic of TCM diagnosis and treatment, and providing metaphysical contemplation and exploration for the construction of a new paradigm of TCM syndrome differentiation and treatment. 
		                        		
		                        		
		                        		
		                        	
5.Measurement performance of Gafchromic film dosimeter
Hui ZHANG ; Hui ZHANG ; Pingquan WANG ; Junkai YANG ; Fan LI ; Ya'nan ZHANG
Chinese Journal of Medical Physics 2024;41(5):541-547
		                        		
		                        			
		                        			Objective To determine the applicable conditions and the film reading time of Gafchromic EBT3 film dosimeter through the research and test of the measurement performance such as blackening time,dosimetry range,dosimetry resolution and dose response non-uniformity.Methods Three Gafchromic films were exposure to different doses,and the optical densities were read at different moments after irradiation for analyzing and confirming the effects of blackening time on dose measurement and different doses on blackening time.The absorbed dose-optical density curve was used to determine Gafchromic film dosimetry range.The Gafchromic film dosimetry resolution was obtained by calculating the average optical densities of two groups with a dose difference of 0.01 Gy.The dose response non-uniformity of Gafchromic film was evaluated by irradiating the whole film and the cutting film.Results Relative to the optical density at the termination moment of irradiation,the optical density changes at 4 h were 1.69%(2 Gy),2.53%(4 Gy)and 2.13%(8 Gy);the changes at 24 h were 2.91%(2 Gy),3.31%(4 Gy)and 3.20%(8 Gy);and the changes at 48 h were 2.91%(2 Gy),3.31%(4 Gy)and 3.96%(8 Gy).The optical density given by Gafchromic film dosimeter within 0.1 to 10.0 Gy had a linear relationship with the absorbed dose,while the optical density of Gafchromic film dosimeter within 10.0 to 30.0 Gy had a nonlinear relationship with the absorbed dose,but there was still a one-to-one correspondence.The difference of the average optical densities of two groups was 0.004 when the inter-group dose difference was 0.01 Gy.The non-uniformity was 2.2%for the whole film and 2.8%for the cutting film.Conclusion Gafchromic EBT3 film reading time can be set at 24 h after irradiation,and the dose is independent of blackening time.Gafchromic film dosimeter can be used for point dosimetry and dose distribution measurement within 0.1 to 10.0 Gy,and point dosimetry within 10.0 to 30.0 Gy.The dosimetry resolution of the Gafchromic film dosimeter is better than 0.01 Gy.To avoid the effect of scattered rays,the cutting film is recommended for testing dose response non-uniformity.
		                        		
		                        		
		                        		
		                        	
6.Microwave sensor for recognition of abnormal nodule tissue on body surface.
Chunxue LI ; Hongfu GUO ; Chen ZHOU ; Xinran WANG ; Junkai BAI
Journal of Biomedical Engineering 2023;40(1):149-154
		                        		
		                        			
		                        			For the detection and identification of abnormal nodular tissues on the body surface, a microwave sensor structure loaded with a spiral resonator is proposed in this paper, a sensor simulation model is established using HFSS software, the structural parameters are optimized, and the actual sensor is fabricated. The S21 parameters of the tissue were obtained when nodules appeared by simulation, and the characteristic relationship between the difference of S21 parameters with position was analyzed and tested experimentally. The results showed that when nodules were present in normal tissues, the curve of S21 parameter difference with position change had obvious inverted bimodal characteristics, and the extreme value of S21 parameter difference appeared when the sensor was directly above the nodules, which was easy to identify the position of nodules. It provides an objective detection tool for the identification of abnormal nodular tissues on the body surface.
		                        		
		                        		
		                        		
		                        			Microwaves
		                        			;
		                        		
		                        			Recognition, Psychology
		                        			;
		                        		
		                        			Computer Simulation
		                        			;
		                        		
		                        			Software
		                        			
		                        		
		                        	
7.Metaverse key technologies and their application status in medical care
Chen CHEN ; Hongmei ZHANG ; Jie KOU ; Lin ZHANG ; Junkai HU ; Guihua WANG
Chinese Journal of Modern Nursing 2023;29(12):1672-1676
		                        		
		                        			
		                        			Metaverse technology, which fully combines virtual reality, augmented reality, digital twins, blockchain, Internet of Things and other technologies, enjoys promising prospects and advantages in medical care. This article reviews the types of Metaverse key technologies and their application status in medical care, proposes to develop "Metaverse + nursing" in the future, and looks forward to it, in order to promote the integration of Metaverse and nursing theory and practice and lay the foundation for subsequent research.
		                        		
		                        		
		                        		
		                        	
8.Construction of sensitive index system for nutritional screening and evaluation of nursing quality in maintenance hemodialysis patients
Yuping LI ; Xin MENG ; Junkai HU ; Guihua WANG ; Lin ZHANG
Chinese Journal of Modern Nursing 2023;29(21):2879-2885
		                        		
		                        			
		                        			Objective:To establish a scientific, sensitive and practical sensitive index system for nutritional screening and nursing quality evaluation of maintenance hemodialysis patients, so as to provide reference for objective evaluation of nutritional screening and nursing quality evaluation of MHD patients.Methods:Based on Donabedian three-dimensional quality structure theory of "structure-process-result", the first draft of the index system was constructed through literature review and semi-structured interview. From September to October 2022, a total of 20 clinical nursing and nursing management experts from the field of hemodialysis in 12 Class Ⅲ Grade A hospitals were selected for two rounds of expert letter consultation to revise and confirm the indicator system.Results:The positive coefficient of the two rounds of expert correspondence were 95.00% and 100.00%, the expert authority coefficient were 0.813 and 0.818, the Kendall's harmony coefficients were 0.121-0.257 (all P<0.05), and the coefficient of variation of each index was less than 0.30. After 2 rounds of expert letter consultation, the sensitive index system for nutritional screening and evaluation of nursing quality for maintenance hemodialysis patients was finally constructed, including 1 structural index, 7 process index and 2 outcome index. Conclusions:In this study, a sensitive index system of nutritional screening and evaluation of nursing quality for maintenance hemodialysis patients with 10 indicators is established, which was scientific, practical and specialized and could be used to standardize the nutritional screening and evaluation nursing work in blood purification centers and promote the continuous improvement of nursing quality.
		                        		
		                        		
		                        		
		                        	
9.Construction of the frailty risk evaluation index system for patients with maintenance hemodialysis
Lin ZHANG ; Xin MENG ; Jie KOU ; Yuping LI ; Junkai HU ; Guihua WANG ; Xiaohui LIU
Chinese Journal of Modern Nursing 2023;29(22):2982-2988
		                        		
		                        			
		                        			Objective:To establish an index system for frailty risk assessment of maintenance hemodialysis patients, and scientifically evaluate frailty risk status of maintenance hemodialysis patients.Methods:With the biopsychosocial medical model as the theoretical framework, semi-structured interview method and Delphi expert consultation method were used to establish and screen indicators and analytic hierarchy process was used to determine the weight of indicators, and an indicator system for frailty risk assessment of patients with maintenance hemodialysis was constructed.Results:The effective recovery rates of the two rounds of expert consultation questionnaires were respectively 100.00% (22/22) and 95.45% (21/22), the expert authority coefficients were respectively 0.85 and 0.84, the Kendall's harmony coefficients of the importance of expert opinions were respectively 0.149 and 0.201, and the Kendall's harmony coefficients of the feasibility of expert opinions were respectively 0.134 and 0.175. Finally, the frailty risk evaluation system for maintenance hemodialysis patients was established, including 3 primary indexes, 8 secondary indexes and 36 tertiary indexes.Conclusions:The established frailty risk evaluation index system for patients with maintenance hemodialysis is scientific and practical and comprehensive in content, which can better reflect the specialty characteristics and provide a basis for frailty risk assessment for maintenance hemodialysis patients.
		                        		
		                        		
		                        		
		                        	
10.A detection method for relative response of a detector matrix
Hui ZHANG ; Hui ZHANG ; Pingquan WANG ; Junkai YANG ; Kun WANG
Chinese Journal of Radiological Medicine and Protection 2022;42(10):799-805
		                        		
		                        			
		                        			Objective:To test the relative response of a detector matrix used for measuring of the dose distribution in radiotherapy in order to ensure the accuracy and reliability of dose distribution measurement result.Methods:The two adjacent detectors can be irradiated at the same radiation dose by translating the detector matrix. The relative response of each detector to the reference detector can be obtained by combining the recursive algorithm. At the same time, the measurement data at different test steps are corrected to the reference step by setting the reference step, which correct the influence on the relative response result caused by the variation of the radiation condition and the detector response.Results:Based on the actual test of a 32 × 32 detector matrix, the relative response of each detector of the detected detector matrix to the reference detector varied from 0.896 to 1.077, with the expanded uncertainty of the relative response result being 0.8% ( k=2). Conclusions:On the premise of no known distribution of a radiation field, the relative response relationship of each detector of a detector matrix can be obtained by this method accurately and expediently, which provides a basic method for the performance evaluation of the detector matrix. The same idea can also be used to determine the relative response relationship of other detector matrices for different measurement purposes.
		                        		
		                        		
		                        		
		                        	
            
Result Analysis
Print
Save
E-mail