1.Neutrophil activation is correlated with acute kidney injury after cardiac surgery under cardiopulmonary bypass
Tingting WANG ; Yuanyuan YAO ; Jiayi SUN ; Juan WU ; Xinyi LIAO ; Wentong MENG ; Min YAN ; Lei DU ; Jiyue XIONG
Chinese Journal of Blood Transfusion 2025;38(3):358-367
[Objective] To explore the relationship between neutrophil activation under cardiopulmonary bypass (CPB) and the incidence of cardiac surgery-associated acute kidney injury (CS-AKI). [Methods] This prospective cohort study enrolled adult patients who scheduled for cardiac surgery under CPB at West China Hospital between May 1, 2022 and March 31, 2023. The primary outcome was acute kidney injury (AKI). Blood samples (5 mL) were obtained from the central vein before surgery, at rewarming, at the end of CPB, and 24 hours after surgery. Neutrophils were labeled with CD11b, CD54 and other markers. To assess the effect of neutrophils activation on AKI, propensity score matching (PSM) was employed to equilibrate covariates between the groups. [Results] A total of 120 patients included into the study, and 17 (14.2%) developed AKI. Both CD11b+ and CD54+ neutrophils significantly increased during the rewarming phase and the increases were kept until 24 hours after surgery. During rewarming, the numbers of CD11b+ neutrophils were significantly higher in AKI compared to non-AKI (4.71×109/L vs 3.31×109/L, Z=-2.14, P<0.05). Similarly, the CD54+ neutrophils counts were also significantly higher in AKI than in non-AKI before surgery (2.75×109/L vs 1.79×109/L, Z=-2.99, P<0.05), during rewarming (3.12×109/L vs 1.62×109/L, Z=-4.34, P<0.05), and at the end of CPB (4.28×109/L vs 2.14×109/L, Z=-3.91, P<0.05). An analysis of 32 matched patients (16 in each group) revealed that CD11b+ and CD54+ neutrophil levels of AKI were 1.74 folds (4.83×109/L vs 2.77×109/L, Z=-2.72, P<0.05) and 2.34 folds (3.32×109/L vs 1.42×109/L, Z=-4.12, P<0.05), respectively, of non-AKI at rewarming phase. [Conclusion] Neutrophils are activated during CPB, and they can be identified by CD11b/CD54 markers. The activated neutrophils of AKI patients are approximately 2 folds of non-AKI during the rewarming phase, with disparity reached peak between groups during rewarming. These findings suggest the removal of 50% of activated neutrophils during the rewarming phase may be effective to reduce the risk of AKI.
2.Role of noninvasive tests in the prognostication of metabolic dysfunction-associated steatotic liver disease
Yue WANG ; Sherlot Juan SONG ; Yichong JIANG ; Jimmy Che-To LAI ; Grace Lai-Hung WONG ; Vincent Wai-Sun WONG ; Terry Cheuk-Fung YIP
Clinical and Molecular Hepatology 2025;31(Suppl):S51-S75
In managing metabolic dysfunction-associated steatotic liver disease, which affects over 30% of the general population, effective noninvasive biomarkers for assessing disease severity, monitoring disease progression, predicting the development of liver-related complications, and assessing treatment response are crucial. The advantage of simple fibrosis scores lies in their widespread accessibility through routinely performed blood tests and extensive validation in different clinical settings. They have shown reasonable accuracy in diagnosing advanced fibrosis and good performance in excluding the majority of patients with a low risk of liver-related complications. Among patients with elevated serum fibrosis scores, a more specific fibrosis and imaging biomarker has proved useful to accurately identify patients at risk of liver-related complications. Among specific fibrosis blood biomarkers, enhanced liver fibrosis is the most widely utilized and has been approved in the United States as a prognostic biomarker. For imaging biomarkers, the availability of vibration-controlled transient elastography has been largely improved over the past years, enabling the use of liver stiffness measurement (LSM) for accurate assessment of significant and advanced fibrosis, and cirrhosis. Combining LSM with other routinely available blood tests enhances the ability to diagnose at-risk metabolic dysfunction-associated steatohepatitis and predict liver-related complications, some reaching an accuracy comparable to that of liver biopsy. Magnetic resonance imaging-based modalities provide the most accurate quantification of liver fibrosis, though the current utilization is limited to research settings. Expanding their future use in clinical practice depends on factors such as cost and facility availability.
3.Spotting undiagnosed significant liver fibrosis in the general population: impact on subsequent clinical care: Editorial on “Prevalence of clinically significant liver fibrosis in the general population: A systematic review and meta-analysis”
Nana PENG ; Mary Yue WANG ; Sherlot Juan SONG ; Terry Cheuk-Fung YIP
Clinical and Molecular Hepatology 2025;31(1):256-260
4.Role of noninvasive tests in the prognostication of metabolic dysfunction-associated steatotic liver disease
Yue WANG ; Sherlot Juan SONG ; Yichong JIANG ; Jimmy Che-To LAI ; Grace Lai-Hung WONG ; Vincent Wai-Sun WONG ; Terry Cheuk-Fung YIP
Clinical and Molecular Hepatology 2025;31(Suppl):S51-S75
In managing metabolic dysfunction-associated steatotic liver disease, which affects over 30% of the general population, effective noninvasive biomarkers for assessing disease severity, monitoring disease progression, predicting the development of liver-related complications, and assessing treatment response are crucial. The advantage of simple fibrosis scores lies in their widespread accessibility through routinely performed blood tests and extensive validation in different clinical settings. They have shown reasonable accuracy in diagnosing advanced fibrosis and good performance in excluding the majority of patients with a low risk of liver-related complications. Among patients with elevated serum fibrosis scores, a more specific fibrosis and imaging biomarker has proved useful to accurately identify patients at risk of liver-related complications. Among specific fibrosis blood biomarkers, enhanced liver fibrosis is the most widely utilized and has been approved in the United States as a prognostic biomarker. For imaging biomarkers, the availability of vibration-controlled transient elastography has been largely improved over the past years, enabling the use of liver stiffness measurement (LSM) for accurate assessment of significant and advanced fibrosis, and cirrhosis. Combining LSM with other routinely available blood tests enhances the ability to diagnose at-risk metabolic dysfunction-associated steatohepatitis and predict liver-related complications, some reaching an accuracy comparable to that of liver biopsy. Magnetic resonance imaging-based modalities provide the most accurate quantification of liver fibrosis, though the current utilization is limited to research settings. Expanding their future use in clinical practice depends on factors such as cost and facility availability.
5.Spotting undiagnosed significant liver fibrosis in the general population: impact on subsequent clinical care: Editorial on “Prevalence of clinically significant liver fibrosis in the general population: A systematic review and meta-analysis”
Nana PENG ; Mary Yue WANG ; Sherlot Juan SONG ; Terry Cheuk-Fung YIP
Clinical and Molecular Hepatology 2025;31(1):256-260
6.Role of noninvasive tests in the prognostication of metabolic dysfunction-associated steatotic liver disease
Yue WANG ; Sherlot Juan SONG ; Yichong JIANG ; Jimmy Che-To LAI ; Grace Lai-Hung WONG ; Vincent Wai-Sun WONG ; Terry Cheuk-Fung YIP
Clinical and Molecular Hepatology 2025;31(Suppl):S51-S75
In managing metabolic dysfunction-associated steatotic liver disease, which affects over 30% of the general population, effective noninvasive biomarkers for assessing disease severity, monitoring disease progression, predicting the development of liver-related complications, and assessing treatment response are crucial. The advantage of simple fibrosis scores lies in their widespread accessibility through routinely performed blood tests and extensive validation in different clinical settings. They have shown reasonable accuracy in diagnosing advanced fibrosis and good performance in excluding the majority of patients with a low risk of liver-related complications. Among patients with elevated serum fibrosis scores, a more specific fibrosis and imaging biomarker has proved useful to accurately identify patients at risk of liver-related complications. Among specific fibrosis blood biomarkers, enhanced liver fibrosis is the most widely utilized and has been approved in the United States as a prognostic biomarker. For imaging biomarkers, the availability of vibration-controlled transient elastography has been largely improved over the past years, enabling the use of liver stiffness measurement (LSM) for accurate assessment of significant and advanced fibrosis, and cirrhosis. Combining LSM with other routinely available blood tests enhances the ability to diagnose at-risk metabolic dysfunction-associated steatohepatitis and predict liver-related complications, some reaching an accuracy comparable to that of liver biopsy. Magnetic resonance imaging-based modalities provide the most accurate quantification of liver fibrosis, though the current utilization is limited to research settings. Expanding their future use in clinical practice depends on factors such as cost and facility availability.
7.Spotting undiagnosed significant liver fibrosis in the general population: impact on subsequent clinical care: Editorial on “Prevalence of clinically significant liver fibrosis in the general population: A systematic review and meta-analysis”
Nana PENG ; Mary Yue WANG ; Sherlot Juan SONG ; Terry Cheuk-Fung YIP
Clinical and Molecular Hepatology 2025;31(1):256-260
8.Research Progress in Closed-loop Insulin Delivery Systems
Xiangqian WEI ; Xiuwen ZHANG ; Yanfang WANG ; Xinwei WEI ; Juan ZHANG ; Kangfan JI ; Shiming ZHANG ; Zhen GU ; Jinqiang WANG
Chinese Journal of Modern Applied Pharmacy 2024;41(10):1303-1312
Individuals with type 1 diabetes or advanced type 2 diabetes suffer insufficient insulin secretion, leading to symptoms of hyperglycemia. To maintain the normal blood glucose levels, those people with diabetes must administer insulin multiple times a day. However, insulin requirements are influenced by several factors such as diet, exercise, and illness, combined with the narrow therapeutic index, making accurate insulin dosage challenging. Excessive insulin administration can even pose life-threatening risks. In addition, frequent daily insulin injections place considerable physiological and psychological burdens on patients. To tackle these challenges, researchers have embarked on the development of closed-loop insulin delivery systems. These systems adjust insulin dosages in real-time changes based on the patient’s blood glucose levels, therefore enhancing both the safety and effectiveness of insulin therapy. This review categorizes closed-loop insulin delivery systems into two types: electronic-based and material-based systems, based on their compositional attributes. The exploration of both types covers their components, developmental history, clinical applications, current pros and cons, and future directions. The relative strengths and limitations of these two categories of closed-loop insulin delivery systems are also compared and discussed.
9.Safety and efficacy of acute stent implantation during endovascular treatment for patients with emergent large vessel occlusion due to intracranial atherosclerotic stenosis
Tian LIN ; Wanling WEN ; Juan DU ; Zheng WU ; Xiangkai KONG ; Wenbo DUAN ; Xiaoyun ZHANG ; Bin DU ; Yiling CAI ; Yongqiang CUI
Chinese Journal of Internal Medicine 2024;63(3):272-278
Objective:To investigate the efficacy and safety of acute stent implantation during endovascular treatment for patients with emergent large vessel occlusion due to intracranial atherosclerotic stenosis.Methods:A retrospective analysis was carried out on 46 patients with emergent large vessel occlusion due to intracranial atherosclerotic stenosis who received endovascular treatment at the Strategic Support Force Medical Center from January 2015 to August 2022. Twenty-seven patients underwent balloon angioplasty alone and 19 patients underwent acute stent implantation. The baseline characteristics, modified thrombolysis in cerebral infarction (mTICI) score of the responsible vessels, modified Rankin scale (mRS) score 90 days after operation, incidence of symptomatic intracranial hemorrhage and mortality of the two groups were evaluated.Results:The proportion of effective recanalization of the offending vessels (mTICI≥2b) in the acute stenting group was slightly higher than that in the balloon angioplasty group (16/19 vs. 81.5%), but the difference was not statistically significant ( P>0.05). Besides, there was no significant difference in the median of mRS between the acute stenting group [3.0(0, 4.0)] and the balloon angioplasty group [4.0(1.0, 5.0)] 90 days after operation ( P>0.05). In terms of safety, the incidence of symptomatic intracranial hemorrhage and mortality were comparable between the two groups ( P>0.05). Conclusions:The effect of acute stent implantation during endovascular treatment for patients with emergent large vessel occlusion due to intracranial atherosclerotic stenosis is not inferior to that of balloon angioplasty, and it does not increase the risk of intracranial bleeding complications.
10.Construction and application evaluation of a multi-dimensional surgical equipment management and control platform based on artificial intelligence and Internet of Things
Guanglei GAN ; Juan HUANG ; Naijuan XU ; Meiling KONG ; Xiangdong GU
China Medical Equipment 2024;21(1):130-134,146
Objective:To construct a multi-dimensional surgical equipment management and control platform based on artificial intelligence and Internet of Things(AIoT)to assist with the refinement and intelligent management medical equipment in hospital operating rooms.Methods:A multi-dimensional surgical equipment control platform based on AIoT was established by integrating the Internet of Things(IoT),big data analysis,indoor positioning technology,artificial intelligence(AI)technology and other technologies to collect real-time process data of surgical equipment such as endoscopy and electrosurgical,and to open up the relationships among information systems relating to surgical equipment,such as hospital information system(HIS),laboratory information system(LIS),radiology information system(RIS)and operation anesthesia management system(OAMS),so as to provide technical support for efficiency analysis,benefit analysis and assets management of surgical equipment.The platform was composed of 3 layers:data extraction layer,data engine layer and AI data analysis layer,including 4 functional modules:automatic data acquisition,deep data fusion,data mining and analysis and data visualization.Results:This platform was launched in Shanghai Municipal Hospital of Traditional Chinese Medicine in June 2022,and had realized achieving intelligent daily management such as indoor positioning of operating room equipment,one click inventory.A set of performance analysis method based on IoT and integrated with information systems was established to automatically count the utilization efficiency and cost-effectiveness of key surgical equipment to realize intelligent service,intelligent management,and digital operation.Conclusion:The construction and application of this platform improved the efficiency of medical equipment in operating rooms,reduced the cost and increased the efficiency,assisted in the refinement and intelligent management of hospital surgical equipment,and provided data support for scientific decision-making of hospital managers.


Result Analysis
Print
Save
E-mail