1.Correlation between sagittal curvature parameters and pain threshold for neck-shoulder muscles in degenerative cervical spondylosis
Yunxiao YANG ; Chenglan HUANG ; Yutong HOU ; Yuan YAO ; Yu ZHAO ; Yuanjing XU ; Zezheng YANG ; Jinwu WANG
Chinese Journal of Tissue Engineering Research 2024;28(24):3879-3884
BACKGROUND:Patients with degenerative cervical spondylosis often suffer from changed varicosity of the cervical spine,unbalanced neck-shoulder muscular strength,and descending power. OBJECTIVE:To probe into the correlation between sagittal curvature parameters and pain threshold for neck-shoulder muscles in degenerative cervical spondylosis. METHODS:Totally 50 patients with degenerative cervical spondylosis received treatment at the 3D Printed Outpatient Center of Shanghai Ninth People's Hospital,Shanghai Jiao Tong University School of Medicine from January 2022 to March 2023 were included in the study.After excluding the 10 patients of cervical lateral projection that failed to meet the measurement conditions,the cervical lateral projections were shot to measure the following iconography parameters:Borden value and C2-7 Cobb angle as well as pain thresholds on the midpoint of the superior trapezius muscle in bilateral bundles and at 1 cm beside the C5-6 interspike.The correlation between sagittal curvature parameters and pain threshold of neck-shoulder muscles in degenerative cervical spondylosis was analyzed. RESULTS AND CONCLUSION:(1)The Borden value of sagittal curvature showed a moderately positive correlation with the bundle pain threshold in the left upper trapezius muscle,the bundle pain threshold in the right upper trapezius muscle,and the pain threshold at the 1 cm of the left side beside the C5-6 interspike(r=0.498,P<0.01;r=0.448,P<0.05;r=0.405,P<0.05)and a weak positive correlation with the pain threshold at the 1 cm of the right side beside the C5-6 interspike(r=0.322,P<0.05).(2)The C2-7 Cobb angle showed a weak positive correlation with the left squared myalgia threshold(r=0.355,P<0.05),and there was no correlation with the pain threshold of the left trapezius muscle and the pain threshold at the 1 cm of both sides beside the C5-6 interspike.(3)There was a correlation between the pain threshold of the neck-shoulder muscles,and a high correlation between the pain threshold of the left and right muscles and the pain threshold within the left and right side muscles,indicating that the neck-shoulder muscles are consistent and may be related to the coordination of the neck-shoulder movements.
2.3D printed personalized cervical orthopedic brace can alleviate and treat early cervical spondylosis
Yunxiao YANG ; Yu ZHAO ; Minghai WANG ; Zezheng YANG ; Jinwu WANG
Chinese Journal of Tissue Engineering Research 2024;28(29):4639-4644
BACKGROUND:Short-term wearing of cervical brace combined with shoulder and neck muscle exercise can significantly improve the symptoms of early cervical spondylosis.After stopping wearing cervical brace,patients'symptoms are easy to recur,which may be due to the lack of cervical curvature correction function. OBJECTIVE:To analyze the effect of 3D printed personalized cervical orthopedic brace for adjusting cervical curvature in the treatment of early cervical spondylosis. METHODS:From January 2021 to January 2023,30 patients with early cervical spondylosis in the Shanghai Fifth People's Hospital,Fudan University were studied,including 11 males and 19 females,with a mean age of(31.7±6.6)years old.All patients customized and wore 3D printed personalized cervical orthopedic braces for 3 hours a day for continuous 12 weeks.Borden value of cervical curvature,pain threshold of shoulder and neck muscles,cervical dysfunction index,and visual analog scale score in 30 patients were recorded before and 4 and 8 weeks after treatment. RESULTS AND CONCLUSION:(1)Compared with before treatment,the difference of Borden value of cervical curvature,right trapezius tenderness threshold,and cervical dysfunction index was not significant in 30 patients after 4 weeks of treatment(P>0.05).Visual analog scale score,left trapezius tenderness threshold,left and right C5C6 tenderness threshold were significantly improved(P<0.05).(2)Compared with before treatment,the cervical curvature Borden value,left and right trapezius tenderness threshold,visual analog scale score,left and right C5C6 tenderness threshold,and cervical dysfunction index of 30 patients were significantly improved after 12 weeks of treatment(P<0.05).(3)Compared with 4 weeks after treatment,the Borden value of cervical curvature,right trapezius tenderness threshold,visual analog scale score,left and right C5C6 tenderness threshold and cervical dysfunction index of 30 patients after 12 weeks of treatment were significantly improved(P<0.05).(4)The results show that short-term wearing of 3D printed personalized cervical orthopedic brace can improve the pain of patients with early cervical spondylosis,while long-term application has certain effect on the recovery of cervical curvature.
3.Effect of photon cervical vertebra massage instrument on improving neck pain and related functions in patients with chronic neck pain
Yuan YAO ; Shizhen ZHANG ; Lei JIN ; Yunxiao YANG ; Wenqiang YU ; Yuanjing XU ; Jinwu WANG
Chinese Journal of Tissue Engineering Research 2024;28(30):4876-4880
BACKGROUND:Red light therapy has the non-invasive and cost-effective characteristics,and is widely used in various acute and chronic pains in clinic.However,currently,the phototherapy equipment used in clinic is expensive and has certain site limitations,so it is necessary to explore more convenient and economical phototherapy applications. OBJECTIVE:To observe the clinical efficacy of a self-developed photon cervical vertebra massage instrument for chronic neck pain. METHODS:From November 2022 to February 2023,24 patients with chronic neck pain were recruited from the Department of Rehabilitation Medicine,Ninth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine,including 18 females and 6 males,with a mean age of(29.67±6.40)years.The body mass index was(21.39±3.52)kg/m2.Photon cervical vertebra massage instrument was used twice a day for 20 minutes each time for four weeks.The changes in visual analog scale score,pressure pain threshold,neck active activity,neck disability index,and Pittsburgh sleep quality index were observed before,after 2 and 4 weeks of treatment. RESULTS AND CONCLUSION:(1)Compared with before treatment,after four weeks of treatment,visual analog scale score,pressure pain threshold,neck disability index,and Pittsburgh sleep quality index were all improved(P<0.05),while some cervical motion(extension,left and right rotation)improved(P<0.05)after 4 weeks of treatment.(2)Bilateral visual analog scale scores,left trapezius muscle pressure pain threshold,C5C6 pressure pain threshold,and neck disability index improved after 2 weeks of treatment(P<0.05).(3)It is indicated that the application of photon cervical vertebra massage instrument can improve the pain score,muscle tenderness,sleep quality,functional level,and partial active activity of patients with chronic neck pain in a short period,and is a convenient,effective,and safe treatment method.
4.Correlation between lumbar spine and pelvic parameters in Lenke type 5 adolescent idiopathic scoliosis
Yutong HOU ; Chenglan HUANG ; Yunxiao YANG ; Ya LI ; Peiwu GUO ; Wenqiang YU ; Yu ZHAO ; Zanbo WANG ; Hong ZENG ; Zhenjiang MA ; Dezhi LU ; Jinwu WANG
Chinese Journal of Tissue Engineering Research 2024;28(36):5753-5758
BACKGROUND:The study of the lumbar spine and pelvis in patients with Lenke type 5 lordosis is limited to the coronal and sagittal planes,and the three-dimensional relationship between the scoliosis and the pelvis has not yet been clarified. OBJECTIVE:To analyze the effect of lumbar scoliosis on the pelvis in patients with Lenke type 5 lordosis and to study the correlation between the lumbar spine and the three-dimensional spatial position of the pelvis. METHODS:Imaging data of 60 patients with Lenke type 5 lordosis scoliosis admitted to the 3D Printing Reception Center of Shanghai Ninth People's Hospital,Shanghai Jiao Tong University School of Medicine from January 2019 to September 2023 were retrospectively analyzed,including Cobb angle,coronal pelvic tilt,lumbar lordosis,left and right pelvic hip width ratio(sacroiliac-anterior superior iliac spine),spinal rotation angle,pelvic tilt,sacral slope,pelvic incidence,coronal deformity angular ratio,sagittal deformity angular ratio,C7 plumb line-center sacral vertical line,apical vertebral translation,and coronal sacral inclination.The information was summarized as a database.SPSS 22.0 software was used to analyze the data related to the lumbar spine and pelvis of the patients with Lenke type 5 primary lumbar curvature adolescent idiopathic scoliosis using Spearman's correlation analysis and linear regression. RESULTS AND CONCLUSION:(1)Cobb angle was highly positively correlated with coronal deformity angular ratio,apical vertebral translation,and spinal rotation angle(r=0.91,r=0.841,r=0.736).(2)Coronal deformity angular ratio was highly positively correlated with apical vertebral translation(r=0.737),moderately positively correlated with C7 plumb line-center sacral vertical line(r=0.514),and moderately negatively correlated with sagittal deformity angular ratio(r=-0.595).(3)There was a high positive correlation between lumbar lordosis and sagittal deformity angular ratio(r=0.942)and a moderate negative correlation with coronal deformity angular ratio(r=-0.554).(4)There was a moderate positive correlation between Cobb angle with coronal pelvic tilt and coronal sacral inclination(r=0.522,r=0.534)and a moderate positive correlation between C7 plumb line-center sacral vertical line and coronal pelvic tilt(r=0.507).Apical vertebral translation with coronal pelvic tilt and coronal sacral inclination showed a moderate positive correlation(r=0.507,r=0.506).Lumbar lordosis with sacral slope and pelvic incidence showed a moderate positive correlation(r=0.512,r=0.538).Sagittal deformity angular ratio was moderately positively correlated with sacral slope and pelvic incidence(r=0.614,r=0.621).(5)Studies have found that the relative position of the lumbar spine and the pelvis is closely related in the horizontal,sagittal and coronal planes.When the lumbar spine affects scoliosis and is rotated,the relative position of the pelvis will also change to compensate,which indicates that while correcting scoliosis,the correction of the pelvis cannot be ignored.
5.Overview of Key Technologies in Surgical Robots and Optimization Discussions
Xunjun MA ; Jun YU ; Haitao LIU ; Ya LI ; Hao WU ; Yanbo HUANG ; Bide XU ; Li LIN ; Jinwu WANG
Chinese Journal of Medical Instrumentation 2024;48(5):505-511
Surgical robot is the national strategic diagnostic and therapeutic equipment research focus,get a number of scientific research institutes,colleges and universities and enterprises pay extensive attention to the design and development of a variety of surgical robots,and registration declaration.This article explores the critical technologies of surgical robots and key areas for optimizing their performance,including kinematic positioning errors,pose errors,feedback model errors,image recognition positioning errors,path planning,and safety aspects.The findings not only provide a scientific basis for future standardization research on surgical robots but also offer significant theoretical and practical references for the research,manufacturing,and registration processes in the medical robotics industry.
6.Corrective effect of 3D printed scoliosis orthoses
Wenqiang YU ; Yutong HOU ; Chenglan HUANG ; Yunxiao YANG ; Dezhi LU ; Caiping WANG ; Jinwu WANG
Chinese Journal of Rehabilitation Theory and Practice 2023;29(4):390-395
ObjectiveTo investigate the in-brace and short-term correction of 3D-printed scoliosis orthoses. MethodsFrom July to December 2021, 36 patients with adolescent idiopathic scoliosis from Ninth People's Hospital, Shanghai Jiaotong University School of Medicine were selected to complete full-length radiographs of the spine before and immediately after wearing the orthosis. They wore the orthosis more than 20 hours a day, and took radiographs six months later. Cobb angle was calculated. They were assessed with Chinese version of the Scoliosis Research Society's outcomes instrument 22 (SRS-22) before wearing and six months follow-up. ResultsThe mean Cobb angle was (22.10±6.29)° before wearing, and it was (7.85±10.90)° immediately after wearing (t = 4.775, P < 0.01) and (14.33±0.74)° six months follow-up (t = 4.189, P < 0.01). The score of functional status of SRS-22 increased six months follow-up (Z = -2.676, P < 0.01). The Cobb angle immediately after wearing correlated with the Cobb angle six months follow-up (r = 0.826, P < 0.05). Conclusion3D-printed scoliosis orthoses can correct the scoliosis satisfactorily, in-brace and in short-term.
7.Application of flat-sided culture tubes during prenatal diagnosis.
Tiansheng LIU ; Hongqian HUANG ; Jiangyu SU ; Wangshang QIN ; Dongmei FEI ; Luping OUYANG ; Minpan HUANG ; Jinwu YU ; Yaqin LEI ; Shan OU ; Weijia SUN ; Qingming QIU ; Qian ZHENG
Chinese Journal of Medical Genetics 2023;40(10):1306-1311
OBJECTIVE:
To assess the value of using flat-sided culture tubes for preparing chromosomes through chorionic villi (CV) and amniotic fluid (AF) cell cultures during prenatal diagnosis.
METHODS:
From February to March 2020, 157 CV samples and 147 AF samples subjected to prenatal diagnosis at the Maternal and Child Health Care Hospital of Guangxi Zhuang Autonomous Region were selected as the study subjects. For each sample, one flat-sided tube and one flask culture were set up by following the standard protocols. The methods were evaluated by comparing the cell growth, experimental process, quality of chromosome preparation and costs.
RESULTS:
The success rates for the culturing of CV and AF samples by the flat-sided culture tube method were 97.45% (153/157) and 97.96% (144/147), respectively. By contrast, the success rates for the conventional flask method were 98.72% (155/157) for CV and 98.64% (145/147) for AF samples. No significant difference was found between the two methods (P > 0.05). The average harvest time required by the flat-sided culture tube method was 8.45 days for CV and 9.43 days for AF cultures, whilst the average harvest time for conventional flask method was 9.05 days and 9.54 days, respectively. The flat-sided culture tube method for CV had required significantly shorter average harvest time than the conventional method (P < 0.001). No statistical significant difference was found in the average harvest time for AF by the two methods (P > 0.05). The conventional culturing method had required three containers with two sample transfers. By contrast, the flat-sided culture tube method was carried out in one tube without any sample transfer. The average total amount of medium used was 3.91 mL for each flat-sided culture tube and 6.26 mL for each conventional flask.
CONCLUSION
The flat-sided culture tube method can provide a simple, cost-effective and error-reducing procedure for the CV and AF samples culture during prenatal diagnosis.
Child
;
Female
;
Pregnancy
;
Humans
;
China
;
Prenatal Diagnosis
;
Chorionic Villi Sampling
;
Amniotic Fluid
;
Cell Proliferation
8.Chinese expert consensus on the diagnosis and treatment of osteoporotic periarticular fracture of the shoulder in the elderly (version 2023)
Yan HU ; Dongliang WANG ; Xiao CHEN ; Zhongmin SHI ; Fengjin ZHOU ; Jianzheng ZHANG ; Yanxi CHEN ; Liehu CAO ; Sicheng WANG ; Jianfei WANG ; Hongliang WANG ; Yong FENG ; Zhimin YING ; Chengdong HU ; Qinglin HAN ; Ming LI ; Xiaotao CHEN ; Zhengrong GU ; Biaotong HUANG ; Liming XIONG ; Yunfei ZHANG ; Zhiwei WANG ; Baoqing YU ; Yong WANG ; Lei ZHANG ; Lei YANG ; Peijian TONG ; Ximing LIU ; Qiang ZHOU ; Feng NIU ; Weiguo YANG ; Wencai ZHANG ; Shijie CHEN ; Jinpeng JIA ; Qiang YANG ; Tao SHEN ; Bin YU ; Peng ZHANG ; Yong ZHANG ; Jun MIAO ; Kuo SUN ; Haodong LIN ; Yinxian YU ; Jinwu WANG ; Kun TAO ; Daqian WAN ; Lei WANG ; Xin MA ; Chengqing YI ; Hongjian LIU ; Kun ZHANG ; Guohui LIU ; Dianying ZHANG ; Zhiyong HOU ; Xisheng WENG ; Yingze ZHANG ; Jiacan SU
Chinese Journal of Trauma 2023;39(4):289-298
Periarticular fracture of the shoulder is a common type of fractures in the elderly. Postoperative adverse events such as internal fixation failure, humeral head ischemic necrosis and upper limb dysfunction occur frequently, which seriously endangers the exercise and health of the elderly. Compared with the fracture with normal bone mass, the osteoporotic periarticular fracture of the shoulder is complicated with slow healing and poor rehabilitation, so the clinical management becomes more difficult. At present, there is no targeted guideline or consensus for this type of fracture in China. In such context, experts from Youth Osteoporosis Group of Chinese Orthopedic Association, Orthopedic Expert Committee of Geriatrics Branch of Chinese Association of Gerontology and Geriatrics, Osteoporosis Group of Youth Committee of Chinese Association of Orthopedic Surgeons and Osteoporosis Committee of Shanghai Association of Chinese Integrative Medicine developed the Chinese expert consensus on the diagnosis and treatment of osteoporotic periarticular fracture of the shoulder in the elderly ( version 2023). Nine recommendations were put forward from the aspects of diagnosis, treatment strategies and rehabilitation of osteoporotic periarticular fracture of the shoulder, hoping to promote the standardized, systematic and personalized diagnosis and treatment concept and improve functional outcomes and quality of life in elderly patients with osteoporotic periarticular fracture of the shoulder.
9.Development and Application of Three-Dimensional Bioprinting Scaffold in the Repair of Spinal Cord Injury
Dezhi LU ; Yang YANG ; Pingping ZHANG ; Zhenjiang MA ; Wentao LI ; Yan SONG ; Haiyang FENG ; Wenqiang YU ; Fuchao REN ; Tao LI ; Hong ZENG ; Jinwu WANG
Tissue Engineering and Regenerative Medicine 2022;19(6):1113-1127
Spinal cord injury (SCI) is a disabling and destructive central nervous system injury that has not yet been successfully treated at this stage. Three-dimensional (3D) bioprinting has become a promising method to produce more biologically complex microstructures, which fabricate living neural constructs with anatomically accurate complex geometries and spatial distributions of neural stem cells, and this is critical in the treatment of SCI. With the development of 3D printing technology and the deepening of research, neural tissue engineering research using different printing methods, bio-inks, and cells to repair SCI has achieved certain results. Although satisfactory results have not yet been achieved, they have provided novel ideas for the clinical treatment of SCI. Considering the potential impact of 3D bioprinting technology on neural studies, this review focuses on 3D bioprinting methods widely used in SCI neural tissue engineering, and the latest technological applications of bioprinting of nerve tissues for the repair of SCI are discussed. In addition to introducing the recent progress, this work also describes the existing limitations and highlights emerging possibilities and future prospects in this field.
10.Effects of different thyroid stimulating hormone cut-off values on the screening of congenital hypothyroidism in newborns in Guangxi
Caijuan LIN ; Xin FAN ; Jinwu YU ; Guoxing GENG ; Xiaotao HUANG ; Fanglu WEI
Chinese Journal of Endemiology 2019;38(9):706-709
Objective To analyze the effects of different thyroid stimulating hormone (TSH) cut-off values on the screening of congenital hypothyroidism (CH) in newborns in Guangxi.Methods The TSH results of 83 608 newborns tested by Genetic Screening Processor (GSP) from the Genetic Metabolism Center of the Maternal and Child Health Hospital of Guangxi Zhuang Autonomous Region from May 2017 to April 2018 were collected.Using the percentile method and the receiver operating characteristic (ROC) curve method,the TSH cut-off values were calculated and compared with the assumed cut-off values 9.00 or 10.00 mU/L,to analyze the effects of four different TSH cut-off values on CH screening.Results Using GSP,the TSH results of 83 608 newborns showed a positive skewed distribution,TSH cut-off value of the percentile method (P99) was 7.96 mU/L,836 cases were suspicious,43 cases were diagnosed with CH (6 cases were missed diagnosis),and 65 cases were high TSH (21 cases were missed diagnosis);TSH cut-off value of the ROC curve method was 6.45 mU/L,1 480 case were suspicious,49 cases were diagnosed with CH,and 86 cases were high TSH,both were no missed diagnosis;when TSH cut-off values were 9.00 or 10.00 mU/L,the suspicious were 478 and 305 cases,respectively,and the confirmed CH were 37 and 35 cases (missed diagnosis were 12 and 14 cases,respectively),high TSH were 46 and 33 cases (missed diagnosis were 40 and 53 cases,respectively).The CH incidence of the ROC curve method was compared with the percentile method and using the cut-off values 9.00 and 10.00 mU/L,the differences were statistically significant (P < 0.05).Conclusions The GSP and ROC curve method were used to successfully establish the TSH cut-off value on the screening of CH in newborns in Guangxi.The cut-off value can not only ensure the accuracy of screening,but also avoid missed diagnosis and reduce birth defects.

Result Analysis
Print
Save
E-mail