1.Elevated Serum Amyloid A2 and A4 in Patients With Guillain–Barré Syndrome
Xiaoying YAO ; Baojun QIAO ; Fangzhen SHAN ; Qingqing ZHANG ; Yan SONG ; Jin SONG ; Yuzhong WANG
Journal of Clinical Neurology 2025;21(3):213-219
Background:
and Purpose Guillain–Barré syndrome (GBS) is an autoimmune-mediated disorder characterized by demyelinating or axonal injury of the peripheral nerve. Our aim is to determine whether serum amyloid A (SAA) is a biomarker of demyelinating injury and disease severity in patients with GBS.
Methods:
This study retrospectively enrolled 40 patients with either the demyelinating or axonal GBS and sex- and age-matched controls with other neurological diseases as well as healthy subjects. The demographic and clinical features at entry were collected. The serum levels of the SAA isoforms SAA1, SAA2, and SAA4 were determined in the patients with GBS and the controls using the enzyme-linked immunosorbent assay and analyzed for the associations between levels of different SAA isoforms and the clinical features of the patients.
Results:
The levels of SAA2 and SAA4 were significantly higher in patients with GBS than in both the other neurological disease controls and the healthy subjects (p<0.05 for all). The level of SAA1 did not differ between patients with GBS and the controls. The level of SAA2 was considerably higher in GBS patients with antecedent infection than in those without infection (p=0.020). The levels of different SAA isoforms were not associated with the disease severity or other clinical features of patients with GBS (p>0.05 for all).
Conclusions
Increased levels of SAA2 and SAA4 may only represent the acute inflammatory status and so cannot be utilized as biomarkers of the disease severity or demyelinating injury in patients with GBS.
2.Elevated Serum Amyloid A2 and A4 in Patients With Guillain–Barré Syndrome
Xiaoying YAO ; Baojun QIAO ; Fangzhen SHAN ; Qingqing ZHANG ; Yan SONG ; Jin SONG ; Yuzhong WANG
Journal of Clinical Neurology 2025;21(3):213-219
Background:
and Purpose Guillain–Barré syndrome (GBS) is an autoimmune-mediated disorder characterized by demyelinating or axonal injury of the peripheral nerve. Our aim is to determine whether serum amyloid A (SAA) is a biomarker of demyelinating injury and disease severity in patients with GBS.
Methods:
This study retrospectively enrolled 40 patients with either the demyelinating or axonal GBS and sex- and age-matched controls with other neurological diseases as well as healthy subjects. The demographic and clinical features at entry were collected. The serum levels of the SAA isoforms SAA1, SAA2, and SAA4 were determined in the patients with GBS and the controls using the enzyme-linked immunosorbent assay and analyzed for the associations between levels of different SAA isoforms and the clinical features of the patients.
Results:
The levels of SAA2 and SAA4 were significantly higher in patients with GBS than in both the other neurological disease controls and the healthy subjects (p<0.05 for all). The level of SAA1 did not differ between patients with GBS and the controls. The level of SAA2 was considerably higher in GBS patients with antecedent infection than in those without infection (p=0.020). The levels of different SAA isoforms were not associated with the disease severity or other clinical features of patients with GBS (p>0.05 for all).
Conclusions
Increased levels of SAA2 and SAA4 may only represent the acute inflammatory status and so cannot be utilized as biomarkers of the disease severity or demyelinating injury in patients with GBS.
3.Elevated Serum Amyloid A2 and A4 in Patients With Guillain–Barré Syndrome
Xiaoying YAO ; Baojun QIAO ; Fangzhen SHAN ; Qingqing ZHANG ; Yan SONG ; Jin SONG ; Yuzhong WANG
Journal of Clinical Neurology 2025;21(3):213-219
Background:
and Purpose Guillain–Barré syndrome (GBS) is an autoimmune-mediated disorder characterized by demyelinating or axonal injury of the peripheral nerve. Our aim is to determine whether serum amyloid A (SAA) is a biomarker of demyelinating injury and disease severity in patients with GBS.
Methods:
This study retrospectively enrolled 40 patients with either the demyelinating or axonal GBS and sex- and age-matched controls with other neurological diseases as well as healthy subjects. The demographic and clinical features at entry were collected. The serum levels of the SAA isoforms SAA1, SAA2, and SAA4 were determined in the patients with GBS and the controls using the enzyme-linked immunosorbent assay and analyzed for the associations between levels of different SAA isoforms and the clinical features of the patients.
Results:
The levels of SAA2 and SAA4 were significantly higher in patients with GBS than in both the other neurological disease controls and the healthy subjects (p<0.05 for all). The level of SAA1 did not differ between patients with GBS and the controls. The level of SAA2 was considerably higher in GBS patients with antecedent infection than in those without infection (p=0.020). The levels of different SAA isoforms were not associated with the disease severity or other clinical features of patients with GBS (p>0.05 for all).
Conclusions
Increased levels of SAA2 and SAA4 may only represent the acute inflammatory status and so cannot be utilized as biomarkers of the disease severity or demyelinating injury in patients with GBS.
4.Research progress on PD-1/PD-L1 inhibitors in neoadjuvant therapy for esophageal cancer
Liji CHEN ; Hongmei MA ; Shifa ZHANG ; Kaize ZHONG ; Dongbao YANG ; Jiuhe SUN ; Hongfeng LIU ; Ru SONG ; Jishan ZHANG ; Haibo CAI
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(05):714-721
Esophageal cancer is one of the malignant tumors that poses a threat to human health, with both high incidence and malignancy. Currently, surgery following neoadjuvant chemoradiotherapy is the standard treatment for locally advanced esophageal cancer; however, the long-term prognosis remains unsatisfactory. In recent years, inhibitors of programmed death protein-1 (PD-1) and its ligand (programmed death ligand-1, PD-L1) have achieved breakthrough progress in other solid tumors, and research on esophageal cancer is gradually being conducted. With the demonstration of good efficacy of PD-1/PD-L1 inhibitors in the first-line and second-line treatment of advanced unresectable esophageal cancer, their incorporation into neoadjuvant treatment regimens has become a hot topic. Therefore, this article reviews the mechanism of action of PD-1/PD-L1 inhibitors and their application in the neoadjuvant treatment of esophageal cancer.
5.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
6.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
7.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
8.Progress of neoadjuvant immunotherapy in the treatment of locally advanced resectable esophageal carcinoma
Junjun HUANG ; Jiuhe SUN ; Shifa ZHANG ; Hongfeng LIU ; Ru SONG ; Qian WANG ; Liji CHEN ; Haibo CAI
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2024;31(07):1058-1065
Surgery is the preferred treatment for resectable esophageal cancer, but in locally advanced esophageal cancer, the effect of surgery alone is not ideal, so surgery-based comprehensive treatment is the best option. Neoadjuvant therapy has become a standard treatment in the treatment of locally advanced resectable esophageal cancer. Neoadjuvant therapy includes neoadjuvant chemotherapy, radiochemotherapy, immunotherapy, targeted therapy, etc. With the significant efficacy and acceptable toxicity of immunotherapy in the first-line and second-line treatment of advanced esophageal cancer, neoadjuvant immunotherapy has become a research hotspot of locally advanced resectable esophageal cancer. This article reviews the latest research progress and some limitations of neoadjuvant immunotherapy in locally advanced resectable esophageal cancer.
10.Exploring the key anti-fatigue components of American ginseng based on metabolomics and zebrafish models
Hui-ru LIU ; Hai-yang WANG ; Zhe WANG ; Li-guo CHEN ; Gui-dong CHENG ; Zhi-hui MA ; Song-song WANG ; Zheng-guo LI ; Li-wen HAN
Acta Pharmaceutica Sinica 2023;58(4):1024-1032
The aim of this paper is to explore the key anti-fatigue active components in the saponin-like composition of American ginseng. The anti-fatigue activity of western ginseng samples was evaluated using a zebrafish model; metabolomics techniques were used to identify the main saponins in western ginseng from different origins; the active substances and relevant targets of the anti-fatigue effect of western ginseng were initially screened by constructing a PPI protein interaction network between western ginseng saponins and disease targets, and the key active ingredients were screened using a molecular docking method; finally, the anti-fatigue activity of the key active ingredients was evaluated using a zebrafish, animal experiment was approved by the Ethics Committee of Shandong Academy of Medical Sciences (SYXK20220005). The anti-fatigue activity of the key active ingredients was evaluated using a zebrafish model. The results of the zebrafish activity evaluation showed that there were significant differences in the activities of the western ginseng samples from the two origins, and a total of 10 different saponins were identified as possibly related to the anti-fatigue activity after further metabolomic testing and pattern discrimination. The core anti-fatigue targets were screened with the help of component-disease target PPI, combined with pharmacophore-like parameters and molecular docking techniques, and pseudoginsenoside F11 was found to have good binding activity to five of the targets. Finally, the zebrafish model revealed that pseudoginsenoside F11 exhibited significant anti-fatigue activity. This study used metabolomics and zebrafish model to screen the key active substances of pseudoginsenoside F11 for its anti-fatigue activity, which will provide a reference for further research on the anti-fatigue of pseudoginsenosides.

Result Analysis
Print
Save
E-mail