1.STAR Guideline Terminology (I): Planning and Launching
Zhewei LI ; Qianling SHI ; Hui LIU ; Xufei LUO ; Zijun WANG ; Jinhui TIAN ; Long GE ; Yaolong CHEN
Medical Journal of Peking Union Medical College Hospital 2025;16(1):216-223
To develop a guideline terminology system and promote its standardization, thereby enhancing medical staff's accurate understanding and correct application of guidelines. A systematic search was conducted for guideline development manuals and method ological literature (as of October 25, 2024). After screening, relevant terms from the guideline planning and launching stages were extracted and standardized. The term list and definitions were finalized through discussion and evaluation at a consensus conference. A total of 36 guideline manuals and 14 method ological articles were included, and 27 core terms were identified. The standardization of guideline terminology is essential for improving guideline quality, facilitating interdisciplinary communication, and enhancing other related aspects. It is recommended that efforts to advance the standardization and continuous updating of the terminology system should be prioritized in the future to support the high-quality development of guidelines.
2.Improving the Certainty of Evidence in Animal Experiment Systematic Review/Meta-Analysis: An Empirical Study of the GRADE Method
Tengfei LI ; Qingyong ZHENG ; Jianguo XU ; Yiyi LI ; Yongjia ZHOU ; Caihua XU ; Mingyue ZHANG ; Jiexiang TIAN ; Gang WANG ; Jinhui TIAN
Laboratory Animal and Comparative Medicine 2025;45(1):101-111
Animal experiments are essential tools in biomedical research, serving as a bridge between basic research and clinical trials. Systematic reviews and meta-analyses (SRs/MAs) of animal experiments are crucial methods for integrating evidence from animal experiment, which can facilitate the translation of findings into clinical research, reduce translational risks, and promote resource integration in basic research. With the continuous development of the Grading of Recommendations, Assessment, Development, and Evaluation (GRADE) methodology, its application in SRs/MAs of animal experiments has gained increasing attention. This article first outlines the principles and specific applications of the GRADE methodology in SRs/MAs of animal experiments, including qualitative descriptive systematic reviews, meta-analyses, and network meta-analyses. It then deeply analyzes the misuse of the GRADE methodology in practice, including incorrect evidence grading, improper classification of evidence, misapplication in qualitative systematic reviews, inconsistencies between the documentation of the upgrading and downgrading process and results, and inappropriate use for making recommendations. Furthermore, this article comprehensively discusses the factors influencing the grading of evidence certainty in SRs/MAs of animal experiments, including the impact of bias risk, indirectness, inconsistency, imprecision, and publication bias on evidence downgrading, as well as the role of large effect sizes and cross-species consistency in evidence upgrading. Finally, in response to the issues discussed, improvement strategies are proposed, including further research and optimization of the GRADE methodology for SRs/MAs of animal experiments, the development of reporting guidelines tailored to the characteristics of SRs/MAs in animal experiment research, and enhanced professional training for researchers in the GRADE methodology. This article aims to improve the quality of evidence in SRs/MAs of animal experiments, strengthen their reliability in clinical decision-making, and promote the more efficient translation of findings from animal experiment research into clinical practice.
3.Monitoring results of mosquito-ovitraps placed in different orientations in multi-storey residential areas
Caixiong LIU ; Bin GE ; Haibing ZHANG ; Lin WANG ; Tao YANG ; Yujiao WEI ; Haiying XIE ; Yu ZHANG ; Hongxia LIU ; Juntao SHEN
Shanghai Journal of Preventive Medicine 2025;37(2):109-113
ObjectiveTo find out whether there is any difference in the monitoring results of mosq-ovitraps placed in different orientations in multi-storey residential areas, so as to provide a scientific basis for routine and emergency monitoring of Aedes albopictus with mosq-ovitraps in residential areas. MethodsFrom July 6th to October 26th 2023, one mosquito ovitrap was set up in each of the 4 orientations of east, south, west and north around the buildings in a multi-storey residential area in Jinhui Town, Fengxian District, Shanghai. Data was collected and recorded 72 hours after placement. The chi-square test was used to compare the mosquito ovitrap indices (MOIs) of two independent samples, and the Kruskal⁃Wallis H test was used to compare the MOIs of multiple independent samples. ResultsAfter 16 weeks of surveillance, 997 mosquito ovitraps were recovered, of which 211 were positive, with the mosquito ovitrap index (MOI) of 21.16% and the Aedes albopictus density index of 1.03 mosquitoes·ovitrap-1. The MOIs were higher in September (24.22%) and October (23.96%), and the MOIs in the west, south and north within the two months were all above 20.00%. From July to October, the MOIs in the east, west, south and north were 20.70%, 22.20%, 25.50% and 16.20%, respectively, and the difference in MOIs among the 4 orientations was not statistically significant (χ2=6.647, P=0.084). Stratified analysis by month showed that in August, the south side of the multi-storey residential areas had the highest MOI (31.30%), the north side had the lowest MOI (1.30%), and there was a statistically significant difference in MOI in the east, west, south and north (χ2=25.986, P<0.001). In October, the MOI in the west was the highest (33.30%) and the MOI in the east was the lowest (6.30%), the difference in MOIs of the 4 orientations was statistically significant (χ2=12.007, P=0.007). The MOIs in the south side of the building in the outskirts of the residential area from the 1st week in July to the 4th week in October was lower (19.20%) than that in the south side of the inner building (31.70%), and the difference in MOI was statistically significant (χ2=5.118, P=0.024). ConclusionThe study of MOI in different orientations in a multi-storey residential area is a preliminary exploration based on field work, and the results show that there is a difference in MOIs in different orientations during the peak breeding period of mosquitoes. Further indicators such as temperature, humidity and wind speed in different orientations can be collected to explore the influencing factors of MOIs.
4.Influence evaluation of pharmaceutical quality control on medication therapy management services by the ECHO model
Kun LIU ; Huanhuan JIANG ; Yushuang LI ; Yan HUANG ; Qianying ZHANG ; Dong CHEN ; Xiulin GU ; Jinhui FENG ; Zijian WANG ; Yunfei CHEN ; Yajuan QI ; Yanlei GE ; Aishuang FU
China Pharmacy 2025;36(9):1123-1128
OBJECTIVE To evaluate the influence of pharmaceutical quality control on the efficiency and outcomes of standardized medication therapy management (MTM) services for patients with coronary heart disease by using Economic, Clinical and Humanistic Outcomes (ECHO) model. METHODS This study collected case data of coronary heart disease patients who received MTM services during January-March 2023 (pre-quality control implementation group, n=96) and June-August 2023 (post-quality control implementation group, n=164). Using propensity score matching analysis, 80 patients were selected from each group. The study subsequently compared the economic, clinical, and humanistic outcome indicators of pharmaceutical services between the two matched groups. RESULTS There were no statistically significant differences in baseline data between the two groups after matching (P>0.05). Compared with pre-quality control implementation group, the daily treatment cost (16.26 yuan vs. 24.40 yuan, P<0.001), cost-effectiveness ratio [23.12 yuan/quality-adjusted life year (QALY) vs. 32.32 yuan/QALY, P<0.001], and the incidence of general adverse drug reactions (2.50% vs. 10.00%, P=0.049) of post-quality control implementation group were decreased significantly; the utility value of the EuroQol Five-Dimensional Questionnaire (0.74± 0.06 vs. 0.71±0.07, P=0.003), the reduction in the number of medication related problems (1.0 vs. 0.5, P<0.001), the medication adherence score ([ 6.32±0.48) points vs. (6.10±0.37) points, P=0.001], and the satisfaction score ([ 92.56±1.52) points vs. (91.95±1.56) points, P=0.013] all showed significant improvements. Neither group experienced serious adverse drug reactions. There was no statistically significant difference in the incidence of new adverse reactions between the two groups (1.25% vs. 3.75%, P=0.310). CONCLUSIONS Pharmaceutical quality control can improve the quality of pharmaceutical care, and the ECHO model can quantitatively evaluate the effect of MTM services, making pharmaceutical care better priced and more adaptable to social needs, thus being worthy of promotion.
5.Application,research hotspots,and shortcomings of degradable zinc-based alloys in bone defect repair and reconstruction
Haoyang LIU ; Qiang XIE ; Mengran SHEN ; Yansong REN ; Jinhui MA ; Bailiang WANG ; Debo YUE ; Weiguo WANG
Chinese Journal of Tissue Engineering Research 2025;29(4):839-845
BACKGROUND:Zinc-based alloy medical implant materials have excellent mechanical properties,complete degradability and good biocompatibility,and are mainly used in orthopedic implants,cardiovascular stents,bile duct stents,tracheal stents,nerve catheters,etc. OBJECTIVE:To review the research progress of biodegradable zinc-based alloys in bone defect repair and prospect the promising research direction and achievements of zinc-based materials. METHODS:After searching PubMed,Web of Science,WanFang Data,and CNKI databases from the establishment of the database to June 2023,various relevant articles on biodegradable zinc-based alloys for bone implant material research were collected.The basic characteristics of biodegradable zinc based alloys were summarized,and the role of zinc-based alloys in promoting bone tissue repair was sorted and summarized.The current research hotspots and shortcomings were discussed. RESULTS AND CONCLUSION:(1)Zinc-based alloys have good biocompatibility.Using zinc-based alloys as the matrix material,with the help of scaffold structure construction technology and coating optimization process,the bone conductivity of zinc-based alloys will be effectively improved,and their degradation products will have efficient bone induction to regulate the gene expression of osteoblasts and osteoclasts,thereby promoting the repair and reconstruction of bone defects.(2)However,in the research on optimizing zinc-based alloys,the coating process is relatively insufficient,and additive loading technology is still lacking.(3)Zinc-based alloys have excellent mechanical and biological properties.Through special processes,their bone conductivity and osteoinductivity can be increased to effectively improve their ability to promote bone repair and reconstruction,and it is expected to further achieve the development of personalized transplant materials.Further research and development are needed to optimize the integration of coating and additive loading technologies into zinc-based alloys.
6.STAR Guideline Terminology(Ⅱ): Clinical Question Formulation, Evidence Retrieval and Appraisal, and Recommendation Development
Di ZHU ; Haodong LI ; Zijun WANG ; Qianling SHI ; Hui LIU ; Yishan QIN ; Yuanyuan YAO ; Zhewei LI ; Hongfeng HE ; Jinhui TIAN ; Long GE ; Yaolong CHEN ;
Medical Journal of Peking Union Medical College Hospital 2025;16(3):756-764
To introduce and analyze guideline terminology related to clinical question formulation, evidence retrieval and appraisal, and recommendation development. A systematic search was conducted in guideline development manuals and relevant methodological literature, covering publications up to October 25, 2024. Terminology related to the three aforementioned stages of related to guideline development was extracted from the included literature, standardized, and refined through consensus meetings to finalize a comprehensive terminology list and definitions. A total of 30 guideline development manuals and 15 methodological articles were included, and 23 core terms were identified. It is recommended to develop a standardized and scientifically sound guideline terminology system with unified naming, clear definitions, and alignment with the linguistic environment and usage habits in China. At the same time, it is essential to strengthen terminology training for both guideline developers and users based on this system, in order to deepen their correct understanding and proper application of guideline terminology.
7.Recommendations for Standardized Reporting of Systematic Reviews and Meta-Analysis of Animal Experiments
Qingyong ZHENG ; Donghua YANG ; Zhichao MA ; Ziyu ZHOU ; Yang LU ; Jingyu WANG ; Lina XING ; Yingying KANG ; Li DU ; Chunxiang ZHAO ; Baoshan DI ; Jinhui TIAN
Laboratory Animal and Comparative Medicine 2025;45(4):496-507
Animal experiments are an essential component of life sciences and medical research. However, the external validity and reliability of individual animal studies are frequently challenged by inherent limitations such as small sample sizes, high design heterogeneity, and poor reproducibility, which impede the effective translation of research findings into clinical practice. Systematic reviews and meta-analysis represent a key methodology for integrating existing evidence and enhancing the robustness of conclusions. Currently, however, the application of systematic reviews and meta-analysis in the field of animal experiments lacks standardized guidelines for their conduct and reporting, resulting in inconsistent quality and, to some extent, diminishing their evidence value. To address this issue, this paper aims to systematically delineate the reporting process for systematic reviews and meta-analysis of animal experiments and to propose a set of standardized recommendations that are both scientific and practical. The article's scope encompasses the entire process, from the preliminary preparatory phase [including formulating the population, intervention, comparison and outcome (PICO) question, assessing feasibility, and protocol pre-registration] to the key writing points for each section of the main report. In the core methods section, the paper elaborates on how to implement literature searches, establish eligibility criteria, perform data extraction, and assess the risk of bias, based on the Preferred Reporting Items for Systematic Reviews and Meta-analysis (PRISMA) statement, in conjunction with relevant guidelines and tools such as Animal Research: Reporting of in Vivo Experiments (ARRIVE) and a risk of bias assessment tool developed by the Systematic Review Centre for Laboratory Animal Experimentation (SYRCLE). For the presentation of results, strategies are proposed for clear and transparent display using flow diagrams and tables of characteristics. The discussion section places particular emphasis on how to scientifically interpret pooled effects, thoroughly analyze sources of heterogeneity, evaluate the impact of publication bias, and cautiously discuss the validity and limitations of extrapolating findings from animal studies to clinical settings. Furthermore, this paper recommends adopting the Grading of Recommendations Assessment, Development and Evaluation (GRADE) methodology to comprehensively grade the quality of evidence. Through a modular analysis of the entire reporting process, this paper aims to provide researchers in the field with a clear and practical guide, thereby promoting the standardized development of systematic reviews and meta-analysis of animal experiments and enhancing their application value in scientific decision-making and translational medicine.
8.Enhancing Disciplinary Development Through Journal Columns: Taking the "Clinical Practice Guidelines"Column in Medical Journal of Peking Union Medical College Hospital as an Example
Meihua WU ; Hui LIU ; Qi ZHOU ; Qianling SHI ; Na LI ; Yule LI ; Xiaoqing LIU ; Kehu YANG ; Jinhui TIAN ; Long GE ; Bin MA ; Xiuxia LI ; Xuping SONG ; Xiaohui WANG ; Yaolong CHEN
Medical Journal of Peking Union Medical College Hospital 2025;16(5):1315-1324
To explore the role of the "Clinical Practice Guidelines" column and others in the We collected papers published by the Lanzhou University Evidence-Based Medicine Center team in the "Clinical Practice Guidelines" column and others from 2018 to 2025. These publications were analyzed across multiple dimensions, including authorship and institutional affiliations, citation metrics, and research themes and content. A total of 59 papers were included in the analysis, with authors representing 70 domestie and international research institutions. The cumulative citation count was 639, with the highest single-paper citation frequency reaching 101. The average citation per paper was 10.8, and total downloads exceeded 30 000. The content focused on key themes such as guideline terminology, development methodology, guideline evaluation, and dissemination and implementation. The evolution of research topics progressed from critiques of common misconceptions and hot topies in the field to multidimensional evaluations of thecurrent state of Chinese guidelines, culminating in the fommulation of industry standards for guidelines. These contributions have provided critical references for translating guideline theory into practice in China and have garnered widespread attention and discussion among scholars in the field. The "Clinical Practice Guidelines" column and others in the
9.Evaluation of the hygiene status of teaching environment in primary and secondary schools in Beijing City from 2016 to 2020
ZHAO Jinhui, QIN Ran, WANG Wenxin, XU Huiyu, GAO Ruoyi, GUO Xin
Chinese Journal of School Health 2024;45(3):431-436
Objective:
To understand the trend of changes of hygiene status in the teaching environment among primary and secondary schools in Beijing City during 2016-2020, so as to provide basis for further improving the teaching environment and campus hygiene conditions in primary and secondary schools.
Methods:
A proportional systematic sampling method covered over 50% of schools selected annually in Beijing from 2016 to 2019, and 34% were selected in 2020. Two representative classrooms were selected from each selected school for testing based on their structure and other factors, with 6 196 classrooms supervised, from 2016 to 2020,1 330,1 312,1 384,1 322,848 classrooms were monitored for each year.
Results:
From 2016 to 2020, the overall lighting qualification rate of classrooms (lighting coefficient 72.8%, window to floor area ratio 41.8%, rear wall reflectance ratio 42.2%, blackboard reflection ratio 37.4%), the overall qualification rate of average blackboard illumination and uniformity (50.6%, 34.9 %), and the overall qualification rate of desk and chair allocation (58.6%) were all below 80%. The overall qualification rate of per capita classroom area (87.5%), blackboard size (83.2%), average desk illumination ( 80.1% ), average desk illumination and uniformity (82.9%), the distance between lamp and desk (99.1%), carbon dioxide ( 86.6% ), temperature (84.9%), and noise (96.6%) were all above 80%. The following indicators, blackboard size, the distance between lamp and desk, average blackboard illumination, lighting coefficient, blackboard reflectance, rear wall reflectance, carbon dioxide, temperature, and noise ( χ 2=78.38, 9.71, 11.76, 320.59, 37.63, 58.45, 236.45, 1 347.56, 101.97), had statistically significance between years. Among those indicators, the qualified rates of blackboard size, blackboard reflectance, lighting coefficient, and noise had been increasing year by year ( χ 2 trend =69.98, 15.82, 240.02, 5.77) ( P <0.05). The qualified rates of per capita classroom area, window to floor area ratio, and blackboard reflection ratio in primary schools (81.6%, 39.8%, 36.3%) were all lower than those in secondary schools (94.9%, 44.5%, 40.3%) ( χ 2=246.32, 12.03, 10.51, P <0.05). The qualified rates of blackboard size, average blackboard illumination, average blackboard illumination and uniformity, and desk and chair allocation (89.3%, 55.6% , 36.0%, and 60.2%) were all higher than those in secondary schools (75.4%, 44.1%, 33.3%, and 56.5%) ( χ 2=209.33, 78.41, 4.44, 8.22) ( P <0.05). The qualified rates of average desk illumination and uniformity, average blackboard illumination, rear wall reflectance ratio, desk and chair allocation, carbon dioxide, temperature, and noise indicators in urban area (82.9%, 84.1% , 51.9%, 45.0%, 60.9%, 91.2%, 89.5%, 97.8%) were all higher than those in suburban area (77.3%, 81.7%, 49.2%, 39.5%, 56.3%, 82.3%, 80.4%, 95.5%) ( χ 2=31.16, 6.28, 4.36, 16.40, 13.39, 105.29, 98.23, 24.66, P <0.05). The qualified rates of the distance between lamp and desk, lighting coefficient, window to floor area ratio, blackboard size, blackboard reflection ratio, average blackboard illumination and uniformity, and per capita classroom area in urban areas (98.8%, 65.2%, 34.3%, 76.7%, 35.9%, 30.1%, 84.6%) were all lower than those in suburban areas (99.4%, 81.4%, 49.8%, 89.7%, 40.2%, 39.6%, 90.3%) ( χ 2=6.80, 171.67, 132.43, 188.46 , 12.45, 60.28, 44.82) ( P <0.05).
Conclusions
The main problems in the teaching environment of schools in Beijing are classroom lighting, as well as desk and chair allocation. The findings suggest technical rationality and operability of relevant standard should be considered when under revision, and standard training and supervision management should be strengthened, with the aim of teaching environment improvement.
10.Study on the control effect of orthokeratology lenses on children with differ-ent types of myopic anisometropia
Jinhui LIU ; Rui XIE ; Ziyou YUAN ; Li WANG
Recent Advances in Ophthalmology 2024;44(4):297-301
Objective To explore the effect of the orthokeratology lenses on the control of different types of aniso-metropia in myopic children.Methods A total of 99 myopic children aged 8 to 16 years who got the orthokeratology len-ses at the Department of Ophthalmology,Heping Hospital Affiliated to Changzhi Medical College from September 2020 to November 2022 with complete data were included.These children were divided into the simple myopic anisometropia group(monocular myopia,binocular diopter difference ≥ 1.00 D,n=39)and the compound myopic anisometropia group(binoc-ular myopia,binocular diopter difference ≥ 1.00 D,n=60).The children with higher anisometropia(binocular diopter difference ≥ 2.50 D)in the two groups were set as the high anisometropia subgroup(n=18 and 29,respectively),and chil-dren with lower anisometropia(1.00 D≤ binocular diopter difference<2.50 D)were set as the low anisometropia subgroup(n=21 and 31,respectively).In each group,eyes with a higher diopter were set as the high diopter eyes,and the contra-lateral eyes with a lower diopter were set as the low diopter eyes.Diopter,corneal topography,intraocular pressure,cor-neal endothelium and axial length of children in the two groups were examined and recorded.The changes in axial length before and after wearing orthokeratology lenses for 1 year were compared between the two groups,analyzing the correla-tion between the degree of anisometropia and changes in the binocular axial length.Results After wearing orthokeratolo-gy lenses for 1 year,children in both groups had an increase in the axial length with a lower increase in the axial length of the high diopter eyes compared to the low diopter eyes;before and 1 year after wearing orthokeratology lenses,the axial length of high diopter eyes was greater than that of the low diopter eyes in both groups,and the differences were statistical-ly significant(all P<0.05).Both groups of children showed a decrease in the binocular axial length difference after wear-ing the orthokeratology lenses for 1 year;before and 1 year after wearing orthokeratology lenses,the binocular axial length difference of children in the simple myopic anisometropia group was greater than that in the compound myopic anisometro-pia group,and the differences were statistically significant(t=4.903 and 2.670;both P<0.05).The changes in binocular axial length difference before and after wearing the orthokeratology lenses of children in the high anisometropia subgroup and low anisometropia subgroup of the simple myopic anisometropia group were greater than those in the high anisometro-pia subgroup and low anisometropia subgroup of the compound myopic anisometropia group,respectively,and the differ-ences were statistically significant(both P<0.05).In the simple myopic anisometropia and compound myopic anisometro-pia groups,the degree of anisometropia was positively correlated with the binocular axial length changes before and 1 year after wearing the orthokeratology lenses(r=0.423 and 0.510,both P<0.05).Conclusion Orthokeratology lenses can effectively reduce the difference in binocular axial length of children with myopic anisometropia,and their control effect on simple myopic anisometropia is better than that of compound myopic anisometropia.


Result Analysis
Print
Save