1.The value of focal echogenicity types in diagnosing different thyroid nodules
Shan JIANG ; Bowen ZHAO ; Jinduo SHOU ; Jiang ZHU
Chinese Journal of Ultrasonography 2021;30(8):703-708
Objective:To explore the applicational value of identifying different types of echogenic foci and distinguishing the lesions between benign and malignant lesions in histopathology classification.Methods:The detailed clinical data of 223 patients (264 thyroid nodules) with echogenic foci in preoperative ultrasound from October 2018 to December 2019 in the Sir Run Run Shaw Hospital of Zhejiang University School of Medicine were retrospectively analyzed. The echogenic foci were categorized as big comet-tail artifact, small comet-tail artifact, microcalcification, coarse calcification, peripheral calcification and eggshell calcification. At the same time, other ultrasonographic features were included in order to comparatively analyze with postoperative pathological findings. Independent samples t test and univariate chi-square test were performed to obtain meaningful information of sex, age, body mass index (BMI), thyroid stimulating hormone (TSH), serum free triiodothyronine (FT 3), serum free thyroxine (FT 4), aspect ratio, composition, margin, echo type, echogenic foci; Logistic regression analysis was performed to screen out the independent influence factors in order to forecast malignant lesions. Spearman correlation analysis was performed to determine the ralationships between the clinical indicators and the pathologic results of thyroid lesions. Results:Among the 264 lesions, there were 219(83.0%) malignant nodules and 45(17.0%) benign nodules. For malignant lesions, except for big comet-tail artifact, other types of echogenic foci were all founded, including 152(69.4%) microcalcification, 41(18.7%) small comet-tail artifact, 17(7.8%) coarse calcification, 7(3.2%) peripheral calcification, 2(0.9%) eggshell calcification. While in benign lesions, there were 13(28.9%) microcalcification, 9(20.0%) coarse calcification, 8(17.8%) peripheral calcification, 6(13.3%) small comet-tail artifact, 6(13.3%) big comet-tail artifact, 3(6.7%) eggshell calcification with all echogenic foci types included. Univariate analysis showed that differences between benign and malignant lesions regarding age, serum FT 4, aspect ratio, composition, margin, echo type, echogenic foci were statistically significant (all P<0.05), Logistic regression analysis indicated that age, serum FT 4, hypoechoic, solid, small comet-tail artifact and microcalcification were independent influence factors for malignancy( OR=0.946, 0.026, 47.656, 9.032, 7.925, 12.767; all P<0.05), age and serum FT 4 were correlated with the pathologic results of thyroid lesions ( rs=-0.259, -0.156; all P<0.05). Conclusions:It is highly suggestive of malignancy when the thyroid lesions are solid, hypoechoic, and echogenic foci type is small comet-tail artifact or microcalcification.
2.The application value of the tissue dispersion quantitative analysis technique in differentiating thyroid nodules
Chuanju ZHANG ; Bowen ZHAO ; Jianghong LYU ; Haishan XU ; Jinduo SHOU ; Lilong XU ; Liming YANG ; Jiang ZHU
Chinese Journal of Ultrasonography 2020;29(10):870-874
Objective:To investigate the application value of the ultrasonic elastic tissue dispersion quantitative analysis technique in differentiating thyroid nodules.Methods:A total of 164 nodules in 143 patients with thyroid nodules were examined by elastography ultrasound at Sir Run Run Shaw Hospital of Zhejiang University School of Medicine from January to November 2014. Eleven parameters were obtained by the tissue dispersion quantitative analysis software. These parameters were compared between benign and malignant groups by Mann-Whitney U test. The correlations between all the parameters and the pathologic results of thyroid nodules were analyzed by Spearman analysis. The receiver operating characteristic(ROC) curve of the parameter with the highest correlation coefficient was constructed. The cut-off value was calculated. Results:All parameters except correlation (CORR) had statistically significant differences between the groups of benign and malignant thyroid nodules(all P<0.01). Moreover, except CORR, the other parameters were correlated with the pathologic results of thyroid nodules(all P<0.05), with the highest coefficient in area ration of low-strain region (%AREA)( r s=0.818). ROC curves were constructed to estimate the clinic values of %AREA in diagnosis of thyroid cancer, the area under ROC curve was 0.991 for %AREA, the cut-off point was 74.83%, the sensitivity and specifity was 98.1% and 89.8%, respectively. Conclusions:The tissue dispersion quantitative analysis technique has high value in the differential diagnosis of benign and malignant thyroid nodules.
3. Study on the prediction of cervical lymph node metastasis risk in preoperative thyroid papillary carcinoma by ultrasonic elemental observation of thyroid nodules
Qian WANG ; Yanyu LI ; Jinduo SHOU ; Leqi WANG ; Jiaoni WANG ; Li GAO ; Deguang ZHANG ; Gaofei HE ; Gonglin FAN ; Jiang ZHU
Chinese Journal of Ultrasonography 2019;28(12):1050-1055
Objective:
To evaluate the correlation between ultrasound features of papillary thyroid carcinoma (PTC) and lymph node metastasis by preoperative ultrasound elemental observation of thyroid nodules.
Methods:
Three hundred and seventy-six patients who underwent primary thyroid surgery and confirmed by ultrasound and pathological data as single-focal PTC from Jannary to December 2017 in Sir Run Run Shaw Hospital of Zhejiang Univbersity College of Medicine were retrospectively analyzed. According to the presence or absence of lymph node metastasis, they were divided into central and lateral lymph node metastasis group and non-metastasis group. Independent risk factors for central lymph node metastasis (CLNM) and lateral lymph node metastasis (LLNM) were analyzed by χ2 test and multivariate Logistic regression.
Results:
Multivariate analysis showed that the posterior margin of the cancer was <0.25 cm from the posterior wall of the thyroid gland as an independent risk factor for CLNM (
4.Role of preoperative washout fluid thyroglobulin from fine-needle aspirates in detecting lymph node metastases of papillary thyroid carcinoma and its influential factors
Wang JIAHUI ; Gao LI ; Shou JINDUO ; Jiang XIANFENG ; Zhang MURUI ; Zhou WEIPING
Chinese Journal of Clinical Oncology 2018;45(22):1142-1146
Objective: To investigate the diagnostic value and influential factors of washout fluid thyroglobulin collected during fine-needle aspiration (FNA-Tg) in detecting lymph node metastases of papillary thyroid carcinoma (PTC) before thyroidectomy. Methods:We retrospectively analyzed 131 patients diagnosed with PTC based on histopathology. They presented with suspicious enlarged cervi-cal lymph nodes and underwent high-frequency ultrasound-guided FNA before the surgery. FNA and FNA-Tg were performed simulta-neously. All the related data were collected. In order to obtain the best cut-off value, the FNA-Tg receiver-operating characteristic curve was generated. The cytopathology and postoperative pathologic results, as well as the ultrasound images during the follow-up, were considered the gold standard. The diagnostic performance of each method (FNA, FNA-Tg, and FNA+FNA-Tg) were compared. Ad-ditionally, some suspicious influential factors such as the anatomical location of lymph nodes and associated laboratory indexes were also analyzed for the diagnostic accuracy of FNA-Tg. Results: The best cut-off value of FNA-Tg in our study was 1.295 ng/mL. The diag-nostic performance of the combined method was the best when compared with other methods, with a sensitivity of 96.4% and speci-ficity of 99.2%. Additionally, FNA-Tg was much more accurate when used in diagnosis of lateral cervical lymph nodes. Among all the as-sociated laboratory indexes, the level of serum Tg (sTg) was an independent predictive factor for an FNA-Tg level above 1.295 ng/mL (odds ratio=1.018). Conclusions: FNA-Tg is a useful tool in the identification of metastatic cervical lymph nodes preoperatively, espe-cially for lateral cervical lymph nodes. In addition, 1.295 ng/mL could be one of the reference standards of the FNA-Tg cut-off value. When the sTg level is high, we should interpret the FNA-Tg results cautiously.
5.Application value of tissue dispersion quantitative analysis technique in different stages of SAT
Chuanju ZHANG ; Chunping NING ; Jiawei TIAN ; Bowen ZHAO ; Jiang ZHU ; Jianghong LV ; Haishan XU ; Jinduo SHOU ; Liming YANG ; Ran CHEN
Chinese Journal of Ultrasonography 2017;26(5):419-423
Objective To investigate the application value of the ultrasonic elastic tissue dispersion quantitative analysis technique in different stages of subacute thyroiditis (SAT).Methods One hundred and forty-four SAT lesions detected from 81 patients were enrolled in the patient group.They were further divided into three subgroups,including acute group (group Ⅰ),medium group (group Ⅱ) and recovery group (group Ⅲ).Another 59 healthy volunteers were collected as control group.All the participants accepted conventional ultrasound and elastographic examinations.Eleven parameters were obtained by the tissue dispersion quantitative analysis software.These parameters were compared between groups and among subgroups by ANOVA.The correlation between all the parameters and the course of SAT were analyzed by Spearman and Multiple linear regression methods.Results Between groups and among subgroups,the complexity (COMP) and correlation (CORR) were not statistically different(all P >0.05).Differences of kurtosis (KURT) and angular secon moment (ASM) among the three subgroups were not significant (all P >0.05).Differences between groups and among subgroups were significantly different among the value of all the other seven indexes (all P <0.01).Moreover,they were all correlated with the clinical staging,with the highest coefficient in area ration of low-strain region (% AREA)(r =-0.881).Regression model was constructed and only % AREA was selected into the regression equation.ROC curves were constructed to estimate the clinic value of % AREA in staging patients of SAT,the areas under ROC curves were0.986(group Ⅰ vs group Ⅱ-Ⅲ) and 0.988 (group Ⅰ-Ⅱ vs group Ⅲ[) for %AREA,respectively.Conclusions The tissue dispersion quantitative analysis technique is helpful in estimating the stiffness of thyroid in patients with SAT.
6. Diagnostic values of BRAFV600E mutation analysis and Bethesda system for reporting thyroid cytopathology in thyroid nodules with TIRADS 4 and 5
Ying HAN ; Bowen ZHAO ; Shiyan LI ; Jianghong LYU ; Jinduo SHOU ; Haishan XU ; Haiya LOU ; Lilong XU ; Li GAO ; Songxiao XU ; Jiang ZHU
Chinese Journal of Otorhinolaryngology Head and Neck Surgery 2017;52(9):686-691
Objective:
To evaluate the diagnostic efficacies of BRAFV600E testing and Bethesda system for reporting thyroid cytopathology (BSRTC) in thyroid nodules with thyroid imaging reporting and data system (TIRADS) category 4 and 5.
Methods:
A total of 187 thyroid nodules in 187 patients underwent the examinations of ultrasound-guided fine needle aspiration cytology (FNAC) and BRAFV600E mutation were analyzed retrospectively. Receive operating characteristic (ROC) curve was used to investigate the diagnostic values of both methods and the clinical application of BRAFV600E combined with BSRTC was evaluated. SPSS17.0 software was used to analyze the data.
Results:
Among 187 thyroid nodules, 123 were malignant nodules confirmed with histopathological examination and 64 benign nodules determined by FNAC, histopathological examination, or long-term follow-up. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of BRAFV600E test were better than those of BSRTC [69.1%, 98.4%, 98.8%, 62.4%(χ2=77.3,
7.The value of thyroglobulin measurement in fine-needle aspiration for diagnosis of suspicious lymph nodes in patients with thyroid carcinoma after thyroidectomy.
Qiang LI ; Bowen ZHAO ; Jianghong LYU ; Jinduo SHOU ; Haishan XU ; Lilong XU ; Li GAO ; Murui ZHANG ; Jiang ZHU
Chinese Journal of Otorhinolaryngology Head and Neck Surgery 2016;51(5):378-382
OBJECTIVETo investigate the value of thyroglobulin measurement in ultrasound guided fine-needle aspiration(FNA-Tg)for detecting neck node metastasis in patients with papillary thyroid carcinoma(PTC)after thyroidectomy.
METHODSA total of 128 suspicious metastatic lymph nodes in 112 patients were retrospectively analyzed. Postoperative pathologic results were taken as the gold standard. The values of FNA and FNA-Tg combined FNA in the diagnosis of metastatic lymph nodes were compared with different ultrasonic features.
RESULTSThe sensitivity, specificity and accuracy of single FNA for the diagnosis of neck node metastasis were 67.5%, 98.0% and 79.7% respectively, and those of FNA-Tg combined FNA were 87.0%, 100.0% and 92.2% respectively. Compared with single FNA, the sensitivity and accuracy of FNA-Tg combined FNA were increased significantly(χ(2)=8.319, P=0.004; χ(2)=8.275, P=0.004). When the ultrasonographic characteristics met any one of five indicators for neck node metastasis, the sensitivity, specificity and accuracy of single FNA for the diagnosis of neck node metastasis were 38.1%, 95.7% and 68.2% respectively, and those of FNA-Tg combined FNA were 71.0%, 100.0% and 86.4% respectively. Compared with single FNA, the sensitivity and accuracy of FNA-Tg combined FNA were increased significantly(χ(2)=4.709, P=0.030; χ(2)=4.141, P=0.042). When the ultrasonographic characteristics met any two of five indicators for neck node metastasis, the sensitivity, specificity and accuracy of single FNA for the diagnosis of neck node metastasis were 55.0%, 100.0% and 73.5% respectively, and those of FNA-Tg combined FNA were 90.0%, 100.0% and 94.1% respectively. Compared with single FNA, the sensitivity and accuracy of FNA-Tg combined FNA were increased significantly(χ(2)=6.140, P=0.013; χ(2)=5.314, P=0.021). The ultrasonographic characteristics met any three, four or five of five indicators or did not meet any of the indicators, there was no significant difference in the value of the diagnosis of metastatic lymph nodes between single FNA and FNA-Tg combined FNA(P>0.05).
CONCLUSIONSThe combination of FNA with FNA-Tg could be helpful in diagnosis of lymph node metastasis. When the suspicious lymph nodes had one or two ultrasound characteristics for neck node metastasis, FNA-Tg could raise the sensitivity and accuracy of FNA, and FNA-Tg could not significantly improve in the diagnosis of FNA when presenting with no or with more than 2 ultrasonographic features.
Biopsy, Fine-Needle ; Carcinoma ; pathology ; Carcinoma, Papillary ; Humans ; Lymph Nodes ; pathology ; Lymphatic Metastasis ; diagnosis ; Postoperative Period ; Retrospective Studies ; Sensitivity and Specificity ; Thyroglobulin ; analysis ; Thyroid Neoplasms ; pathology ; Thyroidectomy
8.Application value of contrast-enhanced ultrasonography for assessing the high-risk population of hepatic malignant tumor.
Panpan LYU ; Shiyan LI ; Email: SHIYAN841015@126.COM. ; Haishan XU ; Lilong XU ; Jianghong LYU ; Jinduo SHOU ; Bowen ZHAO
Chinese Journal of Oncology 2015;37(7):545-548
OBJECTIVETo investigate the clinical value of contrast-enhanced ultrasonography (CEUS) in assessing the high-risk population of hepatic malignant tumor (HMT).
METHODSThree hundred patients with high-risk of HMT were enrolled and examined by CEUS. The clinical data of these patients were collected. A comparative analysis was performed to assess the ability of CEUS for detecting and characterizing lesions in the liver. Kappa test was used for assessing the intra-and inter-observer reliability of CEUS.
RESULTSIn 87 enrolled patients with 119 malignant lesions detected by contrast-enhanced MRI, 112 lesions were detected by CEUS and 95 lesions were detected by unenhanced ultrasonography (US). The detection rate of CEUS for HMT was significant higher than that of US (94.1% vs. 79.8%; P < 0.01). More HMT lesions were detected by CEUS than by US in 17.2% patients. One hundred and seventy-seven patients with 215 lesions were confirmed by pathological diagnosis or long-time follow-up. There were 118 malignant and 97 benign lesions. The accuracy of CEUS for differential diagnosis of the liver lesions was 91.6% (197/215), significantly higher than that by US (59.1%, 127/215) (P < 0.01). CEUS improved the accuracy for 35.0% (62/177) patients. For 96 patients with 105 lesions detected for the first time, the agreement of diagnosis by CEUS was 92.4% (97/105). The reliability of CEUS was high (Kappainter = 0.866; Kappaintra = 0.934).
CONCLUSIONSCEUS improves the detection rate and diagnostic accuracy rate of the HMT high-risk population, with a high agreement for diagnosing the new lesions. CEUS may be considered as a first-line method to assess the high-risk population of HMT conveniently, accurately and reliably.
Contrast Media ; Diagnosis, Differential ; Humans ; Liver ; diagnostic imaging ; Liver Neoplasms ; diagnostic imaging ; pathology ; Magnetic Resonance Imaging ; Reproducibility of Results ; Sensitivity and Specificity ; Ultrasonography
9.Application value of contrast-enhanced ultrasonography for assessing the high-risk population of hepatic malignant tumor
Panpan LYU ; Shiyan LI ; Haishan XU ; Lilong XU ; Jianghong LYU ; Jinduo SHOU ; Bowen ZHAO
Chinese Journal of Oncology 2015;(7):545-548
Objective To investigate the clinical value of contrast?enhanced ultrasonography ( CEUS ) in assessing the high?risk population of hepatic malignant tumor ( HMT ) . Methods Three hundred patients with high?risk of HMT were enrolled and examined by CEUS. The clinical data of these patients were collected. A comparative analysis was performed to assess the ability of CEUS for detecting and characterizing lesions in the liver. Kappa test was used for assessing the intra?and inter?observer reliability of CEUS. Results In 87 enrolled patients with 119 malignant lesions detected by contrast?enhanced MRI, 112 lesions were detected by CEUS and 95 lesions were detected by unenhanced ultrasonography ( US ) . The detection rate of CEUS for HMT was significant higher than that of US (94.1% vs. 79.8%;P<0.01). More HMT lesions were detected by CEUS than by US in 17.2% patients. One hundred and seventy?seven patients with 215 lesions were confirmed by pathological diagnosis or long?time follow?up. There were 118 malignant and 97 benign lesions. The accuracy of CEUS for differential diagnosis of the liver lesions was 91.6% (197/215), significantly higher than that by US (59.1%, 127/215) (P<0.01). CEUS improved the accuracy for 35.0% ( 62/177) patients. For 96 patients with 105 lesions detected for the first time, the agreement of diagnosis by CEUS was 92.4% (97/105). The reliability of CEUS was high (Kappainter=0.866; Kappaintra=0.934) . Conclusions CEUS improves the detection rate and diagnostic accuracy rate of the HMT high?risk population, with a high agreement for diagnosing the new lesions. CEUS may be considered as a first?line method to assess the high?risk population of HMT conveniently, accurately and reliably.
10.Application value of contrast-enhanced ultrasonography for assessing the high-risk population of hepatic malignant tumor
Panpan LYU ; Shiyan LI ; Haishan XU ; Lilong XU ; Jianghong LYU ; Jinduo SHOU ; Bowen ZHAO
Chinese Journal of Oncology 2015;(7):545-548
Objective To investigate the clinical value of contrast?enhanced ultrasonography ( CEUS ) in assessing the high?risk population of hepatic malignant tumor ( HMT ) . Methods Three hundred patients with high?risk of HMT were enrolled and examined by CEUS. The clinical data of these patients were collected. A comparative analysis was performed to assess the ability of CEUS for detecting and characterizing lesions in the liver. Kappa test was used for assessing the intra?and inter?observer reliability of CEUS. Results In 87 enrolled patients with 119 malignant lesions detected by contrast?enhanced MRI, 112 lesions were detected by CEUS and 95 lesions were detected by unenhanced ultrasonography ( US ) . The detection rate of CEUS for HMT was significant higher than that of US (94.1% vs. 79.8%;P<0.01). More HMT lesions were detected by CEUS than by US in 17.2% patients. One hundred and seventy?seven patients with 215 lesions were confirmed by pathological diagnosis or long?time follow?up. There were 118 malignant and 97 benign lesions. The accuracy of CEUS for differential diagnosis of the liver lesions was 91.6% (197/215), significantly higher than that by US (59.1%, 127/215) (P<0.01). CEUS improved the accuracy for 35.0% ( 62/177) patients. For 96 patients with 105 lesions detected for the first time, the agreement of diagnosis by CEUS was 92.4% (97/105). The reliability of CEUS was high (Kappainter=0.866; Kappaintra=0.934) . Conclusions CEUS improves the detection rate and diagnostic accuracy rate of the HMT high?risk population, with a high agreement for diagnosing the new lesions. CEUS may be considered as a first?line method to assess the high?risk population of HMT conveniently, accurately and reliably.

Result Analysis
Print
Save
E-mail