1.Ganmai Dazao Tang Treats Breast Cancer-related Depression via MAPK/NF-κB Signling Pathway
Jieyuan LIU ; Yanli WANG ; Delian NIU ; Mengting LI ; Lijinchuan DONG ; Xinmin LIU ; Hongping HOU ; Guangping ZHANG ; Ying CHEN ; Bo PENG
Chinese Journal of Experimental Traditional Medical Formulae 2024;30(23):170-178
ObjectiveTo investigate the therapeutic effect of Ganmai Dazao Tang on breast cancer-related depression and explore the mechanism of the decoction in regulating immune inflammation and neurotransmitters via the mitogen-activated protein kinase (MAPK)/nuclear factor-κB (NF-κB) pathway. MethodBALB/c mice were randomized into control, model, fluoxetine (5 mg·kg-1·d-1), and low- and high-dose (crude drug 20 and 40 g·kg-1, respectively) Ganmai Dazao Tang groups (n=10). The mouse model of 4T1 orthotopic transplantation-induced breast cancer-related depression-like behavior was established. The depression-like behavior of mice was assessed by the tail suspension test and the forced swimming test. RT-qPCR was employed to determine the mRNA levels of interleukin (IL)-17A, forkhead box P3 (FoxP3),IL-1β, IL-6, and tumor necrosis factor-α (TNF-α) in the cerebral cortex. Flow cytometry was employed to measure the proportions of immune cell subsets in the spleen and thymus. HPLC-MS/MS was employed to measure neurotransmitter levels in the cerebral cortex. Western blotting was employed to detect the activation of the MAPK/NF-κB pathway. ResultCompared with the model group, administration of Ganmai Dazao Tang at a dose of 40 g crude drug·kg-1 continuously for 4 weeks shortened the immobility time of modeled mice in the tail suspension and forced swimming tests (P<0.05), down-regulated the mRNA levels of IL-1β, IL-17A, and TNF-α (P<0.05), increased the proportions of T cells, CD4+ T cells, B cells, helper T 17 (Th17) cells, and regulatory T (Treg) cells, and reduced the proportion of CD8+ T cells (P<0.05). Furthermore, it lowered the levels of 5-hydroxyindoleacetic acid (5-HIAA) and kynurenine (Kyn), decreased the kynurenine/tryptophan (Kyn/Trp) ratio (P<0.05), increased the content of 5-hydroxytryptamine (5-HT), and down-regulated the protein levels of phosphorylated extracellular signal-regulated kinase (p-ERK), phosphorylated p38 MAPK, and phosphorylated nuclear factor-κB p65 (P<0.05). ConclusionGanmai Dazao Tang can down-regulate the expression of inflammatory cytokines such as IL-1β, IL-17A, and TNF-α, restore 5-HT metabolism and Kyn/Trp balance, increase the 5-HT content, and reduce the activation of p38 MAPK, ERK, and the MAPK-mediated NF-κB signaling pathway to reduce neuroinflammation in the treatment of cancer-related depression.
2.Research progress on medicalinjury and protection of active denial system
Jieyuan ZHANG ; Zhaoxia DUAN ; Bingcang LI
Military Medical Sciences 2024;48(4):311-316
The active denial system(ADS)is a millimeter wave electromagnetic directional energy non-lethal technology and the only microwave device against humans.Microwave radiation can cause damage to multiple systems in the human body,including the nervous,circulatory,immune,and reproductive systems.This article outlines the development,basic structure,and equipment of ADS,characteristics and mechanisms of medical injuries due to ADS,medical injury efficacy of ADS in terms of effects on the human body,determinants and skin depth.The precautions against and medical treatment of ADS-caused symptoms are briefly described.
3.Application of three dimensional printed personalized guide plate assisted arthroscopic ankle arthrodesis in the treatment of ankle arthritis
Guangyi LI ; Cheng WANG ; Jiazheng WANG ; Chenglin WU ; Jieyuan ZHANG ; Jian ZOU ; Jianfeng XUE ; Yan SU ; Guohua MEI ; Zhongmin SHI ; Xin MA
Chinese Journal of Surgery 2024;62(6):572-580
Objective:To compare the efficacy of conventional open ankle fusion and three dimensional(3D) printed guide plate assisted arthroscopic ankle fusion.Methods:A retrospective cohort study was performed on 256 patients with advanced traumatic ankle arthritis, who were admitted to the Department of Orthopaedics, Shanghai Sixth People′s Hospital Affiliated to Shanghai Jiao Tong University School of Medicine from May 2018 to February 2023 and underwent ankle fusion procedures. The study cohort comprised 119 males and 137 females, with an age of (59.6±9.5) years (range: 37 to 83 years). Among them, 175 cases underwent internal fixation with plates and screws (58 cases through the combined medial and lateral approach, and 117 cases through the simple lateral approach), 48 cases underwent internal fixation with screws through the anterior approach (conventional open group), and 33 cases underwent minimally invasive arthroscopic ankle fusion assisted by 3D printed guide plate (3D printed guide plate arthroscopy group). Propensity score matching was employed to achieve a 1∶1 match(caliper value=0.02) between the baseline characteristics of patients in the 3D printed guide plate arthroscopy group and the conventional open group. Perioperative and follow-up data between the two groups were compared using the t-test, Mann-Whitney U test, Wilcoxon signed rank test, χ2 test or corrected χ2 test as appropriate. Results:Matching was successfully achieved with 20 cases in both the 3D printed guide plate arthroscopy group and the conventional open group, and there were no statistically significant differences in baseline characteristics between the two groups (all P>0.05). The operation time in the 3D printed guide plate arthroscopy group was significantly longer than that in the conventional open group ((88.9±5.6) minutes vs. (77.9±11.7) minutes; t=-2.392, P=0.022), while the frequency of intraoperative fluoroscopies ((1.7±0.8) times vs. (5.2±1.2) times; t=10.604, P<0.01) and length of hospitalization ((5.5±0.9) days vs. (6.4±1.5) days; t=2.480, P=0.018) were significantly lower in the 3D printed guide plate arthroscopy group compared to the conventional open group. The fusion rate was 95.0% (19/20) in the 3D printed guide plate arthroscopy group and 85.0% (17/20) in the conventional open group, with no statistically significant difference between the two groups ( χ2=0.278, P=0.598). The fusion time was (12.1±2.0) weeks in the conventional open group and (11.1±1.7) weeks in the 3D printed guide plate arthroscopy group, with no statistically significant difference between the two groups ( t=1.607, P=0.116). At the final follow-up, the American Orthopedic Foot and Ankle Society ankle hindfoot scale was (72.6±5.5)points in the 3D printed guide plate arthroscopy group and (70.5±5.8)points in the conventional open group, with no statistically significant difference between the two groups ( t=-1.003, P=0.322). The pain visual analogue score of the 3D printed guide plate arthroscopy group was ( M(IQR)) 1.50 (1.00) points, lower than that of the conventional open group by 3.00 (1.00) points, with statistically significant differences ( Z=-3.937, P<0.01). There was no significant difference in complication rate between the conventional open group and the 3D printed guide plate arthroscopy group (25.0%(5/20) vs. 5.0%(1/20), χ2=1.765, P=0.184). Conclusion:3D printed guide plate assisted arthroscopic ankle fusion exhibited several advantages, including reduced frequency of fluoroscopies, alleviation of postoperative pain, and decreased complications and length of hospitalization.
4.Injury characteristics of human body under Taser attack: a review
Guangming YANG ; Yingguo ZHU ; Jieyuan ZHANG ; Bingcang LI
Chinese Journal of Trauma 2024;40(10):955-960
Non-lethal electric shock devices such as Taser have been widely used by military and police agencies worldwide. Taser can temporarily incapacitate human body mainly through discharge on skeletal muscle, while causing injuries to the tissues and organs such as the heart, skeletal muscle, blood vessel, eyeball, brain, bone and neuropsychiatric behavioral disorders through direct or indirect effects of electrical discharge, mechanical puncture, burning and infection. Though Taser has been introduced into China, there have been few studies about the damage to human body caused by Taser and no relevant systematic medical reviews have been found. However, an overall understanding of the characteristics of Taser injuries to human body is of great significance in reducing the disability and mortality rates caused by Taser as well as treating the injuries. To this end, the authors reviewed the research progress on human body injuries caused by Taser from the characteristics of Taser and the types and features of Taser injuries, aiming to provide references for the diagnosis and treatment of injuries caused by Taser.
5.Application of three dimensional printed personalized guide plate assisted arthroscopic ankle arthrodesis in the treatment of ankle arthritis
Guangyi LI ; Cheng WANG ; Jiazheng WANG ; Chenglin WU ; Jieyuan ZHANG ; Jian ZOU ; Jianfeng XUE ; Yan SU ; Guohua MEI ; Zhongmin SHI ; Xin MA
Chinese Journal of Surgery 2024;62(6):572-580
Objective:To compare the efficacy of conventional open ankle fusion and three dimensional(3D) printed guide plate assisted arthroscopic ankle fusion.Methods:A retrospective cohort study was performed on 256 patients with advanced traumatic ankle arthritis, who were admitted to the Department of Orthopaedics, Shanghai Sixth People′s Hospital Affiliated to Shanghai Jiao Tong University School of Medicine from May 2018 to February 2023 and underwent ankle fusion procedures. The study cohort comprised 119 males and 137 females, with an age of (59.6±9.5) years (range: 37 to 83 years). Among them, 175 cases underwent internal fixation with plates and screws (58 cases through the combined medial and lateral approach, and 117 cases through the simple lateral approach), 48 cases underwent internal fixation with screws through the anterior approach (conventional open group), and 33 cases underwent minimally invasive arthroscopic ankle fusion assisted by 3D printed guide plate (3D printed guide plate arthroscopy group). Propensity score matching was employed to achieve a 1∶1 match(caliper value=0.02) between the baseline characteristics of patients in the 3D printed guide plate arthroscopy group and the conventional open group. Perioperative and follow-up data between the two groups were compared using the t-test, Mann-Whitney U test, Wilcoxon signed rank test, χ2 test or corrected χ2 test as appropriate. Results:Matching was successfully achieved with 20 cases in both the 3D printed guide plate arthroscopy group and the conventional open group, and there were no statistically significant differences in baseline characteristics between the two groups (all P>0.05). The operation time in the 3D printed guide plate arthroscopy group was significantly longer than that in the conventional open group ((88.9±5.6) minutes vs. (77.9±11.7) minutes; t=-2.392, P=0.022), while the frequency of intraoperative fluoroscopies ((1.7±0.8) times vs. (5.2±1.2) times; t=10.604, P<0.01) and length of hospitalization ((5.5±0.9) days vs. (6.4±1.5) days; t=2.480, P=0.018) were significantly lower in the 3D printed guide plate arthroscopy group compared to the conventional open group. The fusion rate was 95.0% (19/20) in the 3D printed guide plate arthroscopy group and 85.0% (17/20) in the conventional open group, with no statistically significant difference between the two groups ( χ2=0.278, P=0.598). The fusion time was (12.1±2.0) weeks in the conventional open group and (11.1±1.7) weeks in the 3D printed guide plate arthroscopy group, with no statistically significant difference between the two groups ( t=1.607, P=0.116). At the final follow-up, the American Orthopedic Foot and Ankle Society ankle hindfoot scale was (72.6±5.5)points in the 3D printed guide plate arthroscopy group and (70.5±5.8)points in the conventional open group, with no statistically significant difference between the two groups ( t=-1.003, P=0.322). The pain visual analogue score of the 3D printed guide plate arthroscopy group was ( M(IQR)) 1.50 (1.00) points, lower than that of the conventional open group by 3.00 (1.00) points, with statistically significant differences ( Z=-3.937, P<0.01). There was no significant difference in complication rate between the conventional open group and the 3D printed guide plate arthroscopy group (25.0%(5/20) vs. 5.0%(1/20), χ2=1.765, P=0.184). Conclusion:3D printed guide plate assisted arthroscopic ankle fusion exhibited several advantages, including reduced frequency of fluoroscopies, alleviation of postoperative pain, and decreased complications and length of hospitalization.
6.Efficacy of osteochondral fragment fixation using bioabsorbable pins for Hepple Ⅱ osteochondral lesions of the talus in adolescents
Cheng WANG ; Xueqian LI ; Shaoling FU ; Chenglin WU ; Jiazheng WANG ; Jieyuan ZHANG ; Guangyi LI ; Jian ZOU ; Jianfeng XUE ; Yan SU ; Guohua MEI ; Guoxun SONG ; Wenqi GU ; Zhongmin SHI
International Journal of Surgery 2023;50(7):473-480,C2-C3
Objective:To investigate the efficacy of osteochondral fragment fixation using bioabsorbable pins for Hepple Ⅱ osteochondral lesions of the talus (OLT) in adolescents.Methods:Retrospective case analysis was used. The clinical data and follow-up results of 13 adolescent patients (13 feet) with Hepple Ⅱ OLT were all treated with osteochondral fragment fixation using bioabsorbable pins admitted to Shanghai Sixth People′s Hospital Affiliated to Shanghai Jiao Tong University School of Medicine from January 2017 to December 2021 were retrospectively analyzed. There were 7 males and 6 females, with 13 right feet. The age was (14.85±2.23) years old, ranged from 12 to 18 years old. According to the American orthopedic foot and ankle society (AOFAS) ankle-hindfoot score, visual analogue scale (VAS) and SF-36 score before operation and at the last follow-up were used to evaluate the efficacy and function of the patients. Measurement data with normal distribution were represented as mean ± standard deviation( ± s), and the comparison between groups was conducted using the t-test; The mearsurement data with skewness distribution were expressed by M( Q1, Q3), and rank-sum test was used for inter-group comparison. Results:Thirteen adolescent patients (13 feet) with Hepple Ⅱ OLT underwent surgery successfully and were followed up for (25.54±9.95) months. All wounds healed by first intention, and no complications such as wound infection and delayed healing occurred. Preoperative AOFAS ankle-posterior foot score, VAS and SF-36 score were 58.62±3.55, 7.00 (6.50, 8.00) and 68.38±4.81, respectively. At the last follow-up, the scores were 97.38±2.73, 1.00 (0.00, 1.00), 91.15±4.28, respectively, and the results were significantly improved at the last follow-up, with the difference between the two groups statistically significant( P<0.05). Conclusion:Osteochondral fragment fixation using bioabsorbable pins which can promote cartilage repair, significantly improve symptoms, and achieve better clinical satisfaction with fewer complications, is a safe and effective surgical treatment option for Hepple Ⅱ OLT in adolescents with satisfactory short-term clinical outcomes.
7.Volumetric measurement to diagnose syndesmotic injury in Danis-Weber B type ankle fractures
Kai YANG ; Xueqian LI ; Shaoling FU ; Cheng WANG ; Jiazheng WANG ; Chenglin WU ; Guoxun SONG ; Jieyuan ZHANG ; Wenqi GU ; Jie XIA ; Fei LIU ; Zhongmin SHI
International Journal of Surgery 2023;50(7):480-486,C4
Objective:To investigate the change of syndesmotic volume via CT scan in Danis-Weber B type ankle fracture, aiming to provide a non-invasive diagnostic method for Danis-Weber B type ankle fracture combined with syndesmotic injury.Methods:Retrospective analysis was performed on 48 patients with Danis-Weber B type ankle fractures in Shanghai Sixth People′s Hospital Affiliated to Shanghai Jiao Tong University School of Medicine from January 2018 to March 2022, including 30 males and 18 females, aging (43.71±19.41) years. Ankle CT scans and three-dimensional reconstructions were performed before surgery and at the last follow-up, measuring the syndesmotic volume between the tibiotalar joint and 1, 3 and 5 cm above the ankle and compared with each other. Intraoperative exploration was used as the gold standard for the syndesmotic injury. Based on the results of exploration of the syndesmotic injury, patients were divided into simple ankle fracture group (fracture group, 25 cases) and ankle fracture combined with syndesmotic injury group (fracture + ligament group, 23 cases). The sensitivity and specificity of this diagnostic method were statistically evaluated. The assessments at the last follow-up were performed to value the clinical effect of surgery. The metric data conforming to the normal distribution were expressed as mean ± standard deviation ( ± s), and the t-tests were used for comparison between groups. The measurement data of skewed distribution were expressed as quartile M( Q1, Q3), and nonparametric tests were used for intergroup comparison. Counting data were expressed as number of cases and percentage (%), and Chi-square test were used for intergroup comparison. Results:In the fracture group, there were no statistically significant differences of the syndesmotic volume at 1, 3, and 5 cm above the ankle joint before surgery and at the last follow-up ( P=0.219, 0.269, 0.103). On the contrary, the volume above were statistically significant in the fracture + ligament group ( P<0.001). There were statistically significant differences in syndesmotic volume between the two groups at 1, 3, and 5 cm above the ankle joint preoperatively ( P=0.005, 0.004, 0.038). By contrast, there were no statistical differences between the two groups postoperatively ( P=0.082, 0.155, 0.249). For the sensitivity and specificity of Danis-Weber B type ankle fractures combined with syndesmotic injury, they were 92% and 67% at 1 cm above the ankle joint, 69% and 87% at 3 cm above the ankle joint, and 62% and 87% at 5 cm above the ankle joint, respectively. The last follow-up clinical function score indicated a good surgical outcome. Conclusions:Volumetric measurement via CT scan is one of the diagnostic methods for evaluating Danis-Weber B type ankle fracture combined with syndesmotic injurys. Open resection internal fixation combined with elastic fixation of the ankle fracture combined with syndesmotic injurys can significantly reduce the lower tibiofibular volume, and the efficacy is definite.
8.Arthroscopic modified Brostr?m procedure plus minimally invasive calcaneal osteotomy for the treatment of chronic lateral ankle instability combined with subtle cavus foot
Shaoling FU ; Wenqi GU ; Xueqian LI ; Cheng CHEN ; Cheng WANG ; Guoxun SONG ; Jieyuan ZHANG ; Jian ZOU ; Jianfeng XUE ; Yan SU ; Guohua MEI ; Zhongmin SHI
Chinese Journal of Trauma 2022;38(8):693-700
Objective:To evaluate the short-term outcome of arthroscopic modified Brostr?m procedure plus minimally invasive calcaneal osteotomy for the treatment of chronic lateral ankle instability combined with subtle cavus foot.Methods:A retrospective cohort study was conducted to analyze the clinical data of 12 patients suffering chronic lateral ankle instability combined with subtle cavus foot admitted to Shanghai Sixth People′s Hospital Affiliated to Shanghai Jiao Tong University from November 2016 to November 2020, including 5 males and 7 females, aged 16-62 years [(40.3±15.1)years]. All patients were treated with arthroscopic modified Brostr?m procedure plus minimally invasive calcaneal osteotomy. The calcaneal pitch angle, Meary′s angle and medial cuneiform height on the foot weight-bearing lateral view plus calcaneus valgus angle on the hindfoot long axial view were compared to evaluate the improvement of bony structure and foot alignment preoperatively and at 3 months and 1 year postoperatively. At the same time, American Orthopedic Foot and Ankle Society (AOFAS) ankle-hindfoot score and visual analogue scale (VAS) were used to evaluate the improvement of ankle function and pain. Postoperative complications were also observed and recorded.Results:All patients were followed up for 1-3 years [(1.6±0.6)years]. The calcaneal pitch angle was decreased from (24.6±5.3)° preoperatively to (22.5±4.9)° at postoperative 3 months and (22.3±5.0)° at postoperative 1 year; the Meary′s angle was decreased from 6.6°(5.2°,7.6°) preoperatively to 2.5°(0.5°,3.8°) at postoperative 3 months and 2.1°(0.5°,3.2°) at postoperative 1 year; the medial cuneiform height was decreased from (24.3±5.3)mm preoperatively to (22.3±4.8)mm at postoperative 3 months and (22.3±4.6)mm at postoperative 1 year; the calcaneus valgus angle was increased from -7.1°(-10.3°,-5.9°) preoperatively to 2.3°(-2.5°,4.5°) at postoperative 3 months and 2.4°(-1.6°,3.8°) at postoperative 1 year (all P<0.01). However, there were no significant differences in the calcaneal pitch angle, Meary′s angle, medial cuneiform height, and calcaneus valgus angle at postoperative 3 months and 1 year (all P>0.05). AOFAS ankle-hindfoot score was increased from (66.8±8.7)points preoperatively to (81.0±5.9)points at postoperative 3 months and (88.6±3.6)points at postoperative 1 year (all P<0.01). According to AOFAS ankle-hindfoot score, the results were excellent in four patients and good in eight patients at postoperative 1 year, with the excellent and good rate of 100%. VAS was decreased from 2.5(2.0,4.0)points preoperatively to 2.0(1.3,2.8)points at postoperative 3 months and 1.0(0,2.0)points at postoperative 1 year (all P<0.01). There were significant differences in the AOFAS ankle-hindfoot score and VAS at postoperative 3 months and 1 year (all P<0.05). Wound malunion was seen in one patient, and healed with a dress changing. All patients had no complications such as vascular or nerve injury. There was no recurrence of malformation or joint instability during 1-year follow-up. Conclusion:For chronic lateral ankle instability combined with subtle cavus foot, arthroscopic modified Brostr?m procedure plus minimally invasive calcaneal osteotomy can stabilize ankle joint, correct hindfoot alignment, improve function and relieve pain.
9.Posterior ankle arthroscopic microfracture with platelet-rich plasma injection for the treatment of osteochondral lesions of the talus
Cheng CHEN ; Shaoling FU ; Xueqian LI ; Cheng WANG ; Guohua MEI ; Yan SU ; Jianfeng XUE ; Jian ZOU ; Jieyuan ZHANG ; Wenqi GU ; Guoxun SONG ; Zhongmin SHI
Chinese Journal of Trauma 2022;38(8):701-707
Objective:To investigate the efficacy of posterior ankle arthroscopic microfracture with platelet-rich plasma (PRP) injection for the treatment of posterior osteochondral lesions of the talus (OLT).Methods:A retrospective case series study was conducted on clinical data of 13 patients with posterior OLT admitted to Shanghai Sixth People′s Hospital Affiliated to Shanghai Jiao Tong University from September 2019 to October 2020. There were 10 males and 3 females, aged 10-65 years [(38.2±15.9)years]. According to Hepple′s classification, four patients were with type II, three with type IV, and six with type V. According to Elias′ grid scheme, nine patients were in zone 7 and four patients in zone 9. The disease duration was 13-51 months [(26.2±11.4)months]. All patients underwent posterior ankle arthroscopic microfracture with PRP injection. The operation time was recorded. The visual analogue scale (VAS), American Orthopedic Foot and Ankle Society (AOFAS) ankle-hindfoot score, and ankle range of motion (ROM) were compared before operation and at 3 months and 1 year after operation. The magnetic resonance observation of cartilage repair tissue (MOCART) score was used to evaluate the repair of cartilage injury at 1 year after operation. Complications were recorded.Results:All patients were followed up for 12-25 months [(15.7±3.7)months]. The operation time ranged from 50 to 90 minutes [(63.8±13.3)minutes]. The VAS improved from 3.0(3.0, 4.0)points before operation to 1.0(0, 2.0)points at 3 months after operation and 1.0(0,1.5)points at 1 year after operation; the AOFAS ankle-hindfoot score was improved from (66.1±11.8)points before operation to (84.8±9.5)points at 3 months after operation and (92.9±8.6)points at 1 year after operation; the ankle ROM was improved from (48.5±7.5)° before operation to (61.9±10.3)° at 3 months after operation and (65.4±11.8)° at 1 year after operation (all P<0.05). There was no significant difference in VAS at 3 months and 1 year after operation ( P>0.05). There were significant differences in AOFAS ankle-hindfoot score and ankle ROM at 3 months and 1 year after operation (all P<0.05). According to AOFAS ankle-hindfoot score, the results were excellent in 11 patients, good in one, and fair in one, with the excellent and good rate of 92%. The MOCART score was 40-85 points [(70.4±14.2)points] at 1 year after operation. There was no postoperative necrosis, infection or neurovascular injury. Two patients had slight transient pain during rehabilitation training and were improved after non-surgical treatment. Conclusion:For posterior OLT, posterior ankle arthroscopic microfracture with PRP injection can effectively alleviate pain, improve ankle function and repair cartilage damage, with satisfactory short-term efficacy.
10.Health risk assessment of heavy metals in direct drinking water among middle and primary schools in Huangpi District of Wuhan
LI Liqing, HUANG Yanli, LIU Yanjie
Chinese Journal of School Health 2021;42(6):925-927
Objective:
To analyze heavy metal health risks of direct drinking water in primary and secondary schools in Huangpi District, Wuhan, so as to provide reference basis for ensuring drinking water safety of teachers and students.
Methods:
Cadmium (Cd), Plumbum (Pb) and arsenic (As) in water samples from primary and secondary schools were detected in accordance with the GB/T 5750-2006 "Standard Examination Methods for Drinking Water", water quality was evaluated based on the Quality Standard for Fine Drinking Water(CJ 94-2005). Health risk assessment model was used to evaluate the potential risk of heavy metals in direct drinking water in primary and secondary schools.
Results:
The unqualified rates of Pb, Cd and As were 0.95%, 1.22% and 0 in 66 primary and secondary schools in Huangpi District, Wuhan. The risk of noncarcinogens related to the direct drinking water of heavy metals (Pb, Cd, As) were less than 1. The range of carcinogenic risks related to the direct drinking water was within the range of 1.07×10 -8 /year -5.58×10 -6 /year which were both within the acceptable level.
Conclusion
Concentrations of cadmium, plumbum and arsenic were not found to be significantly elevated as compared to "Quality Standard for Fine Drinking Water" in Huangpi District of Wuhan. Pb and Cd slightly exceeded the standard, with no significant health risk. Water quality and health risk assessment should be strengthened to ensure the safety of drinking water for teachers and students.


Result Analysis
Print
Save
E-mail