1.Acceptance test of PET/CT based on national standard and the NEMA measurement program
Xuesong SU ; Jianhua GENG ; Chaokun ZHANG ; Hao GUO ; Rong ZHENG ; Xuejuan WANG
China Medical Equipment 2024;21(2):16-22
Objective:To perform acceptance test and performance assessment for Siemens Biograph Vision 600 positron-emission tomography/computed tomography(PET/CT)according to the national health industry standard WS 817-2023.Methods:Spatial resolution,sensitivity,scatter fraction,count loss and random coincidence,correction accuracy of count loss and random coincidence,time-of-flight(TOF)resolution of the PET component within the PET/CT system were tested through the measurement program(NU2-2018)of National Electrical Manufacturers Association(NEMA),which was installed inside of the equipment,in accordance with the requirement of national health industry standard WS 817-2023.The PET/CT registration accuracy was measured through Gantry_offset acquisition program that was built into the equipment.Results:The transversely and axially spatial resolutions of Biograph Vision 600 PET/CT were respectively 3.69 mm and 4.10 mm at 1 cm away from the center of visual field,and were respectively 4.26 mm and 4.89 mm at 10 cm away from the center of visual field,and were respectively 4.68 mm and 4.89 mm at 20 cm away from the center of visual field.The sensitivity of 10 cm away from center and radial of visual field were respectively 16.12 kcps/MBq and 16.00 kcps/MBq.The peak value of noise equivalent count rate(NECR)was 281.60 kcps,and the corresponding radioactivity concentration of peak value was 30.69 kBq/ml.The NECR peak value,scatter fraction and maximum value of the error of relative count rate were respectively 38.17% and 4.0%.The TOF resolution was 209.87 ps when the radioactivity concentration was 5.3 kBq/mL.The registration accuracy values of Biograph Vision 600 PET/CT were 0.347 mm,-0.226 mm and 3.659 mm at the directions of x,y and z axis.Conclusion:It is feasible to perform the acceptance test according to the WS 817-2023 standard through uses the NEMA NU2-2018 standard measurement program that is installed inside of the equipment.The performance indicators can meet requirement of standard as the current national standard GB/T 18988.1-2013 and the health industry standard WS 817-2023 that will being implemented in the test of Biograph Vision 600 PET/CT,which can pass acceptance.
2.Impact of 177Lu-DOTATATE therapy on radiation exposure of ward healthcare staff and accompanying persons
Xuesong SU ; Jinming ZHANG ; Jianhua GENG ; Yingmao CHEN ; Gaofeng LI ; Xuejuan WANG
Chinese Journal of Radiological Health 2024;33(5):510-516
Objective To investigate air radioactivity contamination, surface contamination, ambient dose equivalent rates, and radiation doses to individuals in the treatment room during 177Lu-DOTATATE therapy. Methods A ward for 177Lu-DOTATATE therapy was selected in the nuclear medicine department of a general hospital. Air and surface radioactivity samples were collected before and after therapy for four patients. Ambient dose equivalent rates were measured around the four patients following the initiation of 177Lu-DOTATATE therapy. Measurements were taken at distances of 0.1, 0.3, 0.5, and 1−4 m (with 0.5 m intervals) from the right lateral midsection of the patient’s torso. The measurement time points included 5, 15, and 30 min after initiation of administration, as well as 0−4 h (with 1 h intervals), 24 h, and 48 h post-administration. Radiation exposure doses for personnel at different distances from the patients were calculated for each time interval. Results The results of radioactive aerosol detection for all four patients during and after the administration of 177Lu-DOTATATE were similar to those before administration. Surface contamination was not detected at the measurement locations except for patient number 2. The ambient dose equivalent rates increased with increasing injection dose during the administration. However, the ambient dose equivalent rates decreased significantly within one hour after administration. At the end of the administration, the average ambient dose equivalent rate at a distance of one meter for the four patients was 42.931 μSv/h. From the start of administration to four hours post-administration, personnel maintaining a distance of one meter from the patient received a total radiation dose of 167.64 μSv. Conclusion Air radioactivity contamination does not occur during 177Lu-DOTATATE therapy. However, measures should be taken before the commencement of therapy to address potential surface contamination. Both accompanying persons and healthcare staff receive radiation doses below the stipulated dose constraints throughout the treatment process. Therefore, it is necessary to implement appropriate measures to minimize the radiation exposure of healthcare staff.
3.Analysis of prognosis and influencing factors in radioiodine refractory differentiated thyroid cancer
Xin LIU ; Lin LIN ; Rong FAN ; Ke YANG ; Zhengmao WEI ; Yiqing ZHENG ; Xuejuan WANG ; Jianhua GENG ; Rong ZHENG
Chinese Journal of Radiological Health 2024;33(5):566-572
Objective To analyze the prognosis and influencing factors in patients with radioiodine-refractory differentiated thyroid cancer (RAIR-DTC). Methods A retrospective analysis was conducted on 52 patients with RAIR-DTC who underwent ineffective 131I therapy at the Department of Nuclear Medicine, Cancer Hospital, Chinese Academy of Medical Sciences from October 2016 to January 2020. Patients were categorized into progression and stable groups based on disease progression within five years post-treatment. Differences between groups were analyzed using chi-square test and logistic regression. Independent prognostic risk factors were identified using a Cox proportional hazards model. The Kaplan-Meier method with log-rank test was used to evaluate the impact of treatment on the prognosis of the progression group. Results The 3-year and 5-year survival rates of the 52 patients with RAIR-DTC were 88.5% and 73.1%, respectively. In the progression group, the rates were 81.8% and 57.6%. In the stable group, the rates were 100% and 100%. There were significant differences between the two groups in terms of age, presence of extrathyroidal extension, and the initial 131I treatment dose (P < 0.05). Univariate analysis indicated that the age, pre-ablation stimulated thyroglobulin level before the first 131I treatment, the neutrophil-to-lymphocyte ratio before the first treatment, and the sites of recurrence and metastasis were significantly associated with overall survival (P < 0.05). Multivariate analysis showed that age > 55 years (HR=12.40, 95% CI= 2.09-73.57, P=0.001) and distant metastasis (HR=24.47, 95% CI=4.17-143.75, P < 0.001) were independent risk factors for poor prognosis. Kaplan-Meier curve analysis showed that local surgery and/or targeted therapy significantly prolonged progression-free survival in the progression group (P < 0.001). Conclusion The prognosis for RAIR-DTC is poor, with advanced age and distant metastasis significantly associated with unfavorable outcomes. In elderly patients and those with extrathyroidal invasion, the treatment dose during initial 131I therapy may be appropriately increased to delay disease progression. For patients with disease progression, prompt local surgical intervention and/or targeted therapy is recommended.
4.Effect of adductor canal block and single sciatic nerve block combined with analgesic drugs on pain after total knee arthroplasty
Haoyang GENG ; Wenping LIU ; Guorui WANG ; Bin LIU ; Wei WANG ; Zhanqiao MA ; Jianhua WANG
Chinese Journal of Tissue Engineering Research 2024;28(24):3833-3838
BACKGROUND:Total knee arthroplasty is an effective treatment for late-stage osteoarthritis,but postoperative pain and joint function recovery are the main challenges.Nerve block and mixed drug injection are two common pain relief methods,but the effect of their combined use is still unclear. OBJECTIVE:To investigate the effects of ultrasound-guided continuous adductor canal block+single sciatic nerve block+"cocktail"mixed drug analgesia on postoperative pain relief and joint function recovery in total knee arthroplasty. METHODS:120 patients with osteoarthritis admitted to Hebei Province Cangzhou Hospital of Integrated Traditional and Western Medicine from January to May 2022 were randomly divided into two groups(n=60).The observation group received ultrasound-guided continuous adductor canal block+single sciatic nerve block+"cocktail"mixed drug analgesia.The control group received ultrasound-guided continuous adductor canal block+single sciatic nerve block.The differences in visual analog scale score,hospital for special surgery score,pain mediators,expression levels of inflammatory factors,the occurrence of adverse reactions,and postoperative barehanded muscle strength test were compared between the two groups. RESULTS AND CONCLUSION:(1)The visual analog scale scores at rest and exercise were lower in the observation group than those in the control group at 6,8,12,24,48,and 72 hours postoperatively(P<0.05).(2)Hospital for special surgery scores at 1 and 3 months postoperatively were significantly higher in the observation group than those in the control group(P<0.05).(3)In terms of pain mediators and inflammatory factors,the expression levels were significantly lower in the observation group than those in the control group(P<0.05).(4)There was no statistically significant difference in terms of adverse effects and postoperative barehanded muscle strength examination between the two groups(P>0.05).(5)In total knee arthroplasty,ultrasound-guided continuous adductor canal block and single sciatic nerve block,together with a"cocktail"mixed drug analgesia injected into the joint cavity,can provide excellent analgesia,facilitate the recovery of joint function,and relieve postoperative pain and inflammation with a high degree of safety.
5.Impact of 177Lu-DOTATATE therapy on radiation exposure of ward healthcare staff and accompanying persons
Xuesong SU ; Jinming ZHANG ; Jianhua GENG ; Yingmao CHEN ; Gaofeng LI ; Xuejuan WANG
Chinese Journal of Radiological Health 2024;33(5):510-516
Objective To investigate air radioactivity contamination, surface contamination, ambient dose equivalent rates, and radiation doses to individuals in the treatment room during 177Lu-DOTATATE therapy. Methods A ward for 177Lu-DOTATATE therapy was selected in the nuclear medicine department of a general hospital. Air and surface radioactivity samples were collected before and after therapy for four patients. Ambient dose equivalent rates were measured around the four patients following the initiation of 177Lu-DOTATATE therapy. Measurements were taken at distances of 0.1, 0.3, 0.5, and 1−4 m (with 0.5 m intervals) from the right lateral midsection of the patient’s torso. The measurement time points included 5, 15, and 30 min after initiation of administration, as well as 0−4 h (with 1 h intervals), 24 h, and 48 h post-administration. Radiation exposure doses for personnel at different distances from the patients were calculated for each time interval. Results The results of radioactive aerosol detection for all four patients during and after the administration of 177Lu-DOTATATE were similar to those before administration. Surface contamination was not detected at the measurement locations except for patient number 2. The ambient dose equivalent rates increased with increasing injection dose during the administration. However, the ambient dose equivalent rates decreased significantly within one hour after administration. At the end of the administration, the average ambient dose equivalent rate at a distance of one meter for the four patients was 42.931 μSv/h. From the start of administration to four hours post-administration, personnel maintaining a distance of one meter from the patient received a total radiation dose of 167.64 μSv. Conclusion Air radioactivity contamination does not occur during 177Lu-DOTATATE therapy. However, measures should be taken before the commencement of therapy to address potential surface contamination. Both accompanying persons and healthcare staff receive radiation doses below the stipulated dose constraints throughout the treatment process. Therefore, it is necessary to implement appropriate measures to minimize the radiation exposure of healthcare staff.
6.Analysis of prognosis and influencing factors in radioiodine refractory differentiated thyroid cancer
Xin LIU ; Lin LIN ; Rong FAN ; Ke YANG ; Zhengmao WEI ; Yiqing ZHENG ; Xuejuan WANG ; Jianhua GENG ; Rong ZHENG
Chinese Journal of Radiological Health 2024;33(5):566-572
Objective To analyze the prognosis and influencing factors in patients with radioiodine-refractory differentiated thyroid cancer (RAIR-DTC). Methods A retrospective analysis was conducted on 52 patients with RAIR-DTC who underwent ineffective 131I therapy at the Department of Nuclear Medicine, Cancer Hospital, Chinese Academy of Medical Sciences from October 2016 to January 2020. Patients were categorized into progression and stable groups based on disease progression within five years post-treatment. Differences between groups were analyzed using chi-square test and logistic regression. Independent prognostic risk factors were identified using a Cox proportional hazards model. The Kaplan-Meier method with log-rank test was used to evaluate the impact of treatment on the prognosis of the progression group. Results The 3-year and 5-year survival rates of the 52 patients with RAIR-DTC were 88.5% and 73.1%, respectively. In the progression group, the rates were 81.8% and 57.6%. In the stable group, the rates were 100% and 100%. There were significant differences between the two groups in terms of age, presence of extrathyroidal extension, and the initial 131I treatment dose (P < 0.05). Univariate analysis indicated that the age, pre-ablation stimulated thyroglobulin level before the first 131I treatment, the neutrophil-to-lymphocyte ratio before the first treatment, and the sites of recurrence and metastasis were significantly associated with overall survival (P < 0.05). Multivariate analysis showed that age > 55 years (HR=12.40, 95% CI= 2.09-73.57, P=0.001) and distant metastasis (HR=24.47, 95% CI=4.17-143.75, P < 0.001) were independent risk factors for poor prognosis. Kaplan-Meier curve analysis showed that local surgery and/or targeted therapy significantly prolonged progression-free survival in the progression group (P < 0.001). Conclusion The prognosis for RAIR-DTC is poor, with advanced age and distant metastasis significantly associated with unfavorable outcomes. In elderly patients and those with extrathyroidal invasion, the treatment dose during initial 131I therapy may be appropriately increased to delay disease progression. For patients with disease progression, prompt local surgical intervention and/or targeted therapy is recommended.
7.Exploring the Mechanism of Cichorium Glandulosum in the Treatment of Liver Fibrosis Based on Network Pharmacology and Experimental Validation
Jianhua YANG ; Ruoyu GENG ; Wei ZANG ; Qian LI ; Chao DU ; Junping HU
Chinese Journal of Modern Applied Pharmacy 2024;41(3):303-312
OBJECTIVE
To investigate the mechanism of Cichorium glandulosum in the treatment of liver fibrosis by using network pharmacology and experimental validation.
METHODS
A "component-target-pathway" network was constructed with the help of TCMSP, Pubchem, SwissTargetPrediction and Genecards databases, and the STRING database was used to predict the targets of Cichorium glandulosum against liver fibrosis. KEGG and GO enrichment analysis was performed in the DAVID database, and molecular docking of active ingredients and key targets was docked in AUTODOCK. PDGF-BB was used to induce activation of cells and verify the effects of six compounds, including quercetin, quercetin, chicoric acid, caffeic acid, chlorogenic acid, and isochlorogenic acid, on the proliferation, apoptosis, and liver fibrosis indicators of HSC-T6 cells. Western blotting was used to detect the expression of Ras, ERK1, ERK2, C-fos, and JNK proteins in HSC-T6 cells.
RESULTS
Network pharmacology screened 239 common targets between the components and liver fibrosis, PPI analysis showed that SRC, STAT3, HSP90AA1 and other targets were key targets, KEGG analysis showed that the pathways affected by Cichorium glandulosum included cancer pathways, metabolic pathways, etc. GO analysis predicted that Cichorium glandulosum mainly affected processes such as signal transduction. The molecular docking results showed that the target that could bind well with the components MAPK1, and the components that could bind well with the target aesculetin, caffeic acid and chlorogenic acid. Compared with the model group, the inhibition effect of the six compounds on PDGF-BB-induced HSC-T6 cell activation was stronger, and all 6 compounds had the effects to reverse the index of liver fibrosis, in which aesculetin had the strongest activity(P<0.01). The expression of Ras, ERK1, ERK2, C-fos, and JNK in HSC-T6 cells decreased after the interventions of 6 compounds.
CONCLUSION
Each component of Cichorium glandulosum has different anti liver fibrosis effects, which are related to the inhibition of ERK/RAS pathway activation.
8.Effective Components and Mechanism of Cistanches Herba Aqueous Extract Against Diabetic Nephropathy Based on the Spectral-effect Relationship
Tianhua LIU ; Chong MA ; Baicai WANG ; Ruoyu GENG ; Yao ZHAO ; Junping HU ; Jianhua YANG
Chinese Journal of Modern Applied Pharmacy 2024;41(10):1313-1323
OBJECTIVE
To screen out the pharmacodynamic substances of Cistanches Herba aqueous extracts, explore the basis of the pharmacodynamic substances and their mechanism of action in the treatment of diabetic nephropathy(DN), based on the spectral relationship between the mass spectral peak areas of different elution sites of Cistanches Herba aqueous extracts and their anti-DN effects.
METHODS
UPLC-Orbitrap-MS/MS technique was used to characterise the chromatographic peaks; MTT method was used to detect the effects of different elution sites of Cistanches Herba aqueous extract on the proliferation of high glucose and high fat HK-2 cells; grey correlation analysis and partial least squares method were used to analyse the spectral relationship between mass spectrometry peak area and anti-DN activity. MTT method was used to determine the anti-DN activities of the individual components of Cistanches Herba aqueous extract; biochemical kit and ELISA were used to determine the levels of oxidative indicators(SOD, GSH-P) and inflammatory factors(IL-1β, TNF-α, TGF-β); Western blotting was used to detect the expression of apoptosis-related proteins.
RESULTS
UPLC-Orbitrap-MS/MS technique speculated and identified 72 common compounds; In Cistanches Herba aqueous extracts, water, 20% ethanol, and 40% ethanol-eluted sites differentially increased the proliferation rate of HK-2 cells in a high-sugar, high-fat environment; Partial least squares and grey correlation analyses showed that the constituents of the aqueous extracts of Cistanches Herba with greater anti-DN contributions were 8-epideoxymatricinic acid, geniposidic acid, pinoresinol, betaine and syringin, et al. MTT assay reveals that 8-epi-deoxystrychnic acid and geniposidic acid had significant proliferative effects on HK-2 cells in a high glucose and high fat environment; Biochemical kit and ELISA showed that 8-epideoxystrychnic acid and geniposidic acid were able to up-regulate the activity of SOD and GSH-Px, and at the same time they had an inhibitory effect on the expression of inflammatory factors IL-1β, TNF-α and TGF-β. Western blotting results showed that 8-epideoxystrychnic acid and geniposidic acid were able to down-regulate and up-regulate the markers of dermal mesenchymal transition: α-SMA, Collagen Ⅰ and E-cadherin, and they could exert anti-DN effects by inhibiting the PI3K-Akt pathway.
CONCLUSION
The two compounds, 8-epideoxystrychnic acid and geniposidic acid, which are screened by the spectroeffective relationship of anti-DN among the many chemical constituents contained in Cistanches Herba, can affect oxidative stress, inflammation and epithelial-mesenchymal transformation of renal tubular cells by inhibiting the PI3K-Akt signalling pathway, and improve renal pathology, degree of fibrosis and renal function, which will be useful for the in-depth study of aqueous extracts of Cistanches Herba in the treatment of DN.
9.Study on exposure levels and protection of the thyroids,eye lenses and hands of technologists in SPECT/CT room of hospital
Zuowei ZOU ; Xuesong SU ; Jianhua GENG
China Medical Equipment 2024;21(11):25-29
Objective:To study exposure doses and radiation levels of thyroids,eye lenses and hands of technologists who worked in the single-photon emission computed tomography/computed tomography(SPECT/CT)room,so as to provide a reference for assessing radiation hazards and radiation protection of technologists in SPECT/CT machine room.Methods:During February 2019 and October 2020,2 technologists each of two SPECT/CT machine rooms of the department of nuclear medicine of Cancer Hospital,Chinese Academy of Medical Sciences were selected,and the optically stimulated luminescence(OSL)dosimeters were used to monitor the exposure doses of four technologists in the SPECT/CT room in 7 quarters.The total amount that they put positions of patients were 20 682 patients.The technologist routinely wore lead aprons(0.5 mmPb)and lead collars(0.5 mmPb)during clinical work.OSL dosimeters were placed on the thyroids,the locations nearby the eyes and hands of each technologist.Each one of 4 technologists wore a set of dosimeters(included three sets for the thyroid,the locations nearby the eye and hand).The monitoring period that technologists wore OSL dosimeters was 21 months.The personal dose equivalent[Hp(10)]of thyroid at 10 mm depth,the personal dose equivalent[Hp(3)]of the location nearby eyes at 3 mm depth,and the personal dose equivalent[Hp(0.07)]of hands at 0.07 mm were monitored as quarter.The exposure doses of the thyroids,eye lens and hands of 4 technologists in SPECT/CT machine room were assessed on the basis of these results of measurements.All four technologists also underwent dose monitor of routine external radiation.Results:The average number of each technologist who put position was approximately 2 955 patients.Among of the four technologists,the exposure doses of thyroid,eye lens and hand of only one technologist were highest,which were respectively 0.129,0.071 and 0.151 mSv,while they were far below the constraint values(5,5 and 125mSv/a)of dose for radiation workers.Conclusion:The four technologists of the SPECT/CT room directly contact with patients who have been injected with radiopharmaceuticals during they put the positions of patients.But,the exposure doses of their thyroid,eye lenses and hands are far below the constraint value of dose for radiation workers.The reasonable use of personal protective equipment as requirement can effectively safeguard against radiation exposure during technologist put position of patient.
10.Performance evaluation of PET/CT based on silicon photomultiplier and photomultiplier tube under clinical imaging conditions
Xuesong SU ; Jianhua GENG ; Yibin WANG ; Xuejuan WANG ; Rong ZHENG ; Jing LI
Chinese Journal of Radiological Medicine and Protection 2024;44(5):428-435
Objective:To investigate the spatial resolution and image quality of positron emission tomography and X-ray computed tomography (PET/CT) based on the next-generation silicon photomultiplier (SiPM) and the conventional photomultiplier tube (PMT) and to explore the effects of different PET photoelectric transducers (PMT and SiPM) and the Q. Clear algorithm on the spatial resolution, quantitative accuracy, and image quality of PET/CT.Methods:GE Discovery Elite PET/CT (PMT PET/CT) and GE Discovery Meaningful Insights (MI) PET/CT (SiPM PET/CT) were employed to scan the elliptical resolution phantom and NEMA NU2-2018 image quality phantom. Using the OSEM+ PSF+ TOF (VPFX-S) algorithm, image reconstruction was performed based on raw data of both phantoms. For the MI-acquired phantom data, additional reconstructions were conducted using the Q. Clear algorithm, with β values ranging from 150 to 550 and an increment of 100. For the elliptical resolution phantom, the radial, tangential, and axial full-width at half-maximum (FWHM) values of five line sources in three slices were calculated and averaged. For the image quality phantom, the recovery coefficient (RC), contrast recovery coefficient (CRC), contrast-to-noise ratio (CNR), percentage of background variability (PBV), background coefficient of variability (BCV) of the spheres, as well as the residual error (RE) of lung inserts at different image slices, were calculated.Results:Compared to Elite, MI (VPFX-S) showed decreases in the radial, tangential, and axial FWHM of 4.25%-13.58%, 7.00%-13.22%, and 6.02%-36.14%, respectively; no significant difference in RCmax for the spheres; increases in spheres′ CRC and CNR of 10.17%-38.89% and 38.31%-94.95%, respectively, and decreases in spheres′ PBV and BCV of 26.20%-33.82% and 31.29%-35.97%, respectively. When compared to MI (VPFX-S), MI (Q.Clear) showed decreases in the radial, tangential, and axial FWHM of 6.49%-45.02%, 7.80%-35.60%, and 13.31%-36.80%, respectively; an increase in spheres′ CNR of 38.31%-94.95%; decreases in spheres′ PBV and BCV of 26.20%-33.82% and 6.64%-10.31%, respectively, and no significant difference in spheres′ RC. With an increase in the β value, the CNR, RE, and FWHM in radial, tangential, and axial directions derived from MI (Q.Clear) increased, while RC, CRC, PBV, and BCV decreased. Conclusions:Under image reconstruction using VPFX-S, the next-generation SiPM PET/CT exhibits elevated spatial resolution, hot lesion contrast, detectability, and background noise compared to the PMT PET/CT. Compared to OSEM, the Q. Clear algorithm improves spatial resolution, quantitative accuracy, and image quality, with such improvement related to the β value. The β value affects the outcomes of the Q. Clear algorithm, especially the maximum quantitative value of small lesions. This is particularly important for improving clinical diagnostic capabilities.