1.Plasma miRNA testing in the differential diagnosis of very early-stage hepatocellular carcinoma: a multicenter real-world study
Jie HU ; Ying XU ; Ao HUANG ; Lei YU ; Zheng WANG ; Xiaoying WANG ; Xinrong YANG ; Zhenbin DING ; Qinghai YE ; Yinghong SHI ; Shuangjian QIU ; Huichuan SUN ; Qiang GAO ; Jia FAN ; Jian ZHOU
Chinese Journal of Clinical Medicine 2025;32(3):350-354
		                        		
		                        			
		                        			Objective To explore the application of plasma 7 microRNA (miR7) testing in the differential diagnosis of very early-stage hepatocellular carcinoma (HCC). Methods This study is a multicenter real-world study. Patients with single hepatic lesion (maximum diameter≤2 cm) who underwent plasma miR7 testing at Zhongshan Hospital, Fudan University, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Anhui Provincial Hospital, and Peking University People’s Hospital between January 2019 and December 2024 were retrospectively enrolled. Patients were divided into very early-stage HCC group and non-HCC group, and the clinical pathological characteristics of the two groups were compared. The value of plasma miR7 levels, alpha-fetoprotein (AFP), and des-gamma-carboxy prothrombin (DCP) in the differential diagnosis of very early-stage HCC was evaluated using receiver operating characteristic (ROC) curves and area under the curve (AUC). In patients with both negative AFP and DCP (AFP<20 ng/mL, DCP<40 mAU/mL), the diagnostic value of plasma miR7 for very early-stage HCC was analyzed. Results A total of 64 528 patients from 4 hospitals underwent miR7 testing, and 1 682 were finally included, of which 1 073 were diagnosed with very early-stage HCC and 609 were diagnosed with non-HCC. The positive rate of miR7 in HCC patients was significantly higher than that in non-HCC patients (67.9% vs 24.3%, P<0.001). ROC curves showed that the AUCs for miR7, AFP, and DCP in distinguishing HCC patients from the non-HCC individuals were 0.718, 0.682, and 0.642, respectively. The sensitivities were 67.85%, 43.71%, and 44.45%, and the specificities were 75.70%, 92.78%, and 83.91%, respectively. The pairwise comparison of AUCs showed that the diagnostic efficacy of plasma miR7 detection was significantly better than that of AFP or DCP (P<0.05). Although its specificity was slightly lower than AFP and DCP, the sensitivity was significantly higher. Among patients negative for both AFP and DCP, miR7 maintained an AUC of 0.728 for diagnosing very early-stage HCC, with 67.82% sensitivity and 77.73% specificity. Conclusions Plasma miR7 testing is a potential molecular marker with high sensitivity and specificity for the differential diagnosis of small hepatic nodules. In patients with very early-stage HCC lacking effective molecular markers (negative for both AFP and DCP), miR7 can serve as a novel and effective molecular marker to assist diagnosis.
		                        		
		                        		
		                        		
		                        	
2.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
		                        		
		                        			 Purpose:
		                        			This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard. 
		                        		
		                        			Methods:
		                        			Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated. 
		                        		
		                        			Results:
		                        			Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001). 
		                        		
		                        			Conclusion
		                        			Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD. 
		                        		
		                        		
		                        		
		                        	
3.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
		                        		
		                        			 Purpose:
		                        			This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard. 
		                        		
		                        			Methods:
		                        			Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated. 
		                        		
		                        			Results:
		                        			Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001). 
		                        		
		                        			Conclusion
		                        			Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD. 
		                        		
		                        		
		                        		
		                        	
4.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
		                        		
		                        			 Purpose:
		                        			This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard. 
		                        		
		                        			Methods:
		                        			Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated. 
		                        		
		                        			Results:
		                        			Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001). 
		                        		
		                        			Conclusion
		                        			Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD. 
		                        		
		                        		
		                        		
		                        	
5.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
		                        		
		                        			 Purpose:
		                        			This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard. 
		                        		
		                        			Methods:
		                        			Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated. 
		                        		
		                        			Results:
		                        			Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001). 
		                        		
		                        			Conclusion
		                        			Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD. 
		                        		
		                        		
		                        		
		                        	
6.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
		                        		
		                        			 Purpose:
		                        			This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard. 
		                        		
		                        			Methods:
		                        			Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated. 
		                        		
		                        			Results:
		                        			Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001). 
		                        		
		                        			Conclusion
		                        			Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD. 
		                        		
		                        		
		                        		
		                        	
7.Biallelic variants in RBM42 cause a multisystem disorder with neurological, facial, cardiac, and musculoskeletal involvement.
Yiyao CHEN ; Bingxin YANG ; Xiaoyu Merlin ZHANG ; Songchang CHEN ; Minhui WANG ; Liya HU ; Nina PAN ; Shuyuan LI ; Weihui SHI ; Zhenhua YANG ; Li WANG ; Yajing TAN ; Jian WANG ; Yanlin WANG ; Qinghe XING ; Zhonghua MA ; Jinsong LI ; He-Feng HUANG ; Jinglan ZHANG ; Chenming XU
Protein & Cell 2024;15(1):52-68
		                        		
		                        			
		                        			Here, we report a previously unrecognized syndromic neurodevelopmental disorder associated with biallelic loss-of-function variants in the RBM42 gene. The patient is a 2-year-old female with severe central nervous system (CNS) abnormalities, hypotonia, hearing loss, congenital heart defects, and dysmorphic facial features. Familial whole-exome sequencing (WES) reveals that the patient has two compound heterozygous variants, c.304C>T (p.R102*) and c.1312G>A (p.A438T), in the RBM42 gene which encodes an integral component of splicing complex in the RNA-binding motif protein family. The p.A438T variant is in the RRM domain which impairs RBM42 protein stability in vivo. Additionally, p.A438T disrupts the interaction of RBM42 with hnRNP K, which is the causative gene for Au-Kline syndrome with overlapping disease characteristics seen in the index patient. The human R102* or A438T mutant protein failed to fully rescue the growth defects of RBM42 ortholog knockout ΔFgRbp1 in Fusarium while it was rescued by the wild-type (WT) human RBM42. A mouse model carrying Rbm42 compound heterozygous variants, c.280C>T (p.Q94*) and c.1306_1308delinsACA (p.A436T), demonstrated gross fetal developmental defects and most of the double mutant animals died by E13.5. RNA-seq data confirmed that Rbm42 was involved in neurological and myocardial functions with an essential role in alternative splicing (AS). Overall, we present clinical, genetic, and functional data to demonstrate that defects in RBM42 constitute the underlying etiology of a new neurodevelopmental disease which links the dysregulation of global AS to abnormal embryonic development.
		                        		
		                        		
		                        		
		                        			Female
		                        			;
		                        		
		                        			Animals
		                        			;
		                        		
		                        			Mice
		                        			;
		                        		
		                        			Humans
		                        			;
		                        		
		                        			Child, Preschool
		                        			;
		                        		
		                        			Intellectual Disability/genetics*
		                        			;
		                        		
		                        			Heart Defects, Congenital/genetics*
		                        			;
		                        		
		                        			Facies
		                        			;
		                        		
		                        			Cleft Palate
		                        			;
		                        		
		                        			Muscle Hypotonia
		                        			
		                        		
		                        	
8.A New Exploration on the Property and Usage of Shenshu Points
Tao HUANG ; Hong-Peng HUANG ; Jian-Shuang SHI ; Xi WEN
Journal of Guangzhou University of Traditional Chinese Medicine 2024;41(3):659-663
		                        		
		                        			
		                        			As an acupoint where the qi of the kidneys is infused in the back and waist,Shenshu(BL23)points belongs to the category of the foot taiyang bladder meridian,which is widely used clinically in the treatment of genitourinary system diseases.Shenshu points are located in the back of the human body foot taiyang bladder meridian direct branch circulation,and for the foot shaoyin meridian of where the symptom is,therefore it has a special property.However,there is a lack of in-depth research on the point properties and utilization of Shenshu points,thus this paper explores their acupoint properties based on the theories of channel,symptom and root cause,and the four seas,and investigates the correlations between their therapeutic efficacy and the method of moxibustion,acupoint matching,and depth of needling through the ancient books and clinical practice.The results showed that different methods of acupuncture and moxibustion,the combination of acupoints,and the depth of needling can stimulate the different therapeutic effects of the Shenshu.Therefore,the therapeutic effects of the Shenshu points can only be better utilized if the acupoints are clearly identified and supplemented with appropriate methods of acupuncture and moxibustion,the compatibility of acupoints,and the depth of needling.
		                        		
		                        		
		                        		
		                        	
9.A clinicopathological analysis of cervical carcinoma with basaloid features
Yanrui ZHANG ; Xinyi HUANG ; Jian SHI ; Yihui YANG ; Limin LIU ; Haiyan HU
The Journal of Practical Medicine 2024;40(2):163-168
		                        		
		                        			
		                        			Objective To investigate the clinical and pathological features of adenoid basal cell carcinoma(ABC),adenoid cystic carcinoma(ACC),and basaloid squamous cell carcinoma(BSCC)with basaloid charac-teristics and improve the diagnostic and differential diagnostic ability of clinicians and pathologists for these lesions.Methods A retrospective study was conducted on the clinical and pathological data of 4 cases of ABC,1 case of ACC,and 3 cases of BSCC diagnosed and treated at Shenzhen Maternal and Child Health Hospital,Southern Medical University from April 2018 to December 2022.Pathological slides were reviewed and relevant literature was analyzed and summarized.Results All three types of tumors were common in postmenopausal women and were associated with high-risk HPV infection.ABC was a low-grade cancer and patients were often clinically asymp-tomatic.It was usually detected incidentally during cervical screening due to cytological abnormalities,or after cervical cone biopsy or hysterectomy for HSIL.It presented as superficial cervical infiltration and clinical staging was often early.ACC and BSCC were intermediate to high-grade cancers and they often presented with postmenopausal vaginal bleeding.A visible mass was observed on the cervix.The clinical staging was intermediate to advanced.The three types of lesions could coexist.Careful observation of the morphological characteristics and immunohistochemical staining could help with differential diagnosis.None of the 8 patients experienced recurrence or metastasis during follow-up.Conclusion Cervical ABC,ACC and BSCC are rare and they originate from reserve cells.They share the similarities in clinical and pathological morphology,but differ in treatment and prognosis.So,accurate differen-tiation among them has important clinical significance.
		                        		
		                        		
		                        		
		                        	
10.The landing error scoring system as a screening tool for non-contact injury risk in college soccer athletes
Jinqin ZHANG ; Jian CUI ; Xiaolin GAO ; Yongjin SHI ; Chao ZHU ; Peng HUANG
Chinese Journal of Tissue Engineering Research 2024;28(11):1641-1646
		                        		
		                        			
		                        			BACKGROUND:The landing error scoring system test is a standard for assessing the risk of non-contact injuries and has not yet been developed for Chinese college soccer programs. OBJECTIVE:To establish a test evaluation standard for the landing error scoring system to provide a basis for evaluating the risk of non-contact injuries in college soccer students. METHODS:A prospective cohort study was designed in which 219 athletes from 10 college soccer teams were tested with the standard landing error scoring system,and the subjects were followed up by questionnaires and medical examinations for non-contact injuries of the lower extremities and trunk for 1 year after testing to determine sex differences and assessment criteria for the landing error scoring system test indicators. RESULTS AND CONCLUSION:The total score of the landing error scoring system was(8.22±1.65)points for 219 subjects,(8.29±1.74)for males and(8.07±1.44)for females,with no significant difference between males and females(P>0.05).Within 1 year after the test,the overall injury rate of 219 subjects was 10.05%and the morbidity rate was 15.98%;the injury rate of male subjects with non-contact injury of the lower limbs and trunk was 12.75%and the morbidity rate was 20.13%;the injury rate of female subjects with non-contact injury of the lower limbs and trunk was 4.29%and the morbidity rate was 7.14%.There were no significant differences in the injury rate between men and women(P<0.05).The total score of the landing error scoring system was higher in the injury group than in the non-injury group[(9.50±1.14)vs.(8.08±1.64),P<0.01];for male subjects,the total score of the landing error scoring system was higher in the injury group than in the non-injury group[(9.63±1.12)vs.(8.09±1.73),P<0.01].The area under the curve for the total score of the landing error scoring system was 0.773(P=0.000),which had a diagnostic value for the risk of non-contact injury of the lower extremities and trunk in male subjects,with a best cut-off point of 8.5,sensitivity of 0.842,specificity of 0.623,positive likelihood ratio of 2.233,negative likelihood ratio of 0.254,relative risk factor of 8.400,and odds ratio of 8.816;the total score of the landing error scoring system was not applicable for assessing the risk of non-contact injury of the lower extremities and trunk in female subjects.To conclude,the landing error scoring system test can be used as a criterion to assess the risk of non-contact injury to the lower extremity and trunk in Chinese college male soccer players,with an optimal cut-off point of 8.5.The risk of non-contact injury to the lower extremity and trunk is 8.40 times higher in male athletes with a landing error scoring system test score of≥8.5 than in male athletes with a score of<8.5.
		                        		
		                        		
		                        		
		                        	
            
Result Analysis
Print
Save