1.Application values of fixed tube current based on head circumference in children's head CT examinations
Jian ZHANG ; Chuanzhen BIAN ; Xiaojun ZHANG
Journal of Practical Radiology 2024;40(1):115-118
Objective To explore the application values of fixed tube current based on head circumference(HC)in children's head CT examinations.Methods A total of 573 children's head CT imaging data were collected retrospectively,the tube current and HC were recorded.Pearson's correlation analysis was used to determine the relationship of tube current with HC,counted the median tube current values of each group based on HC and used them as the prefixed tube current.Seventy-two children were prospectively collected.According to the random number table method,the children were divided into the control group and the experimental group,with 35 cases in the control group and 37 cases in the experimental group.The control group used automatic exposure control(AEC)technology for tube current,while the experimental group used the median value of tube current corresponding to HC group-ing.The difference in radiation doses and image qualities between the two groups was compared.Results Pearson analysis of 573 retrospec-tive cases showed that the correlation between HC and tube current was considerably strong(r=0.95,P<0.001).The median tube current values of each group based on HC were 70-130 mAs.There were statistically significant differences in CTDIvol.16 and SSDEDW based on water equivalent diameter(DW)between the two groups(t=-11.27,2.81,P<0.05).Compared with the control group,CTDIvol.16 and SSDEDW in the experimental group decreased by 10.83%and 12.59%respectively.There were no statistically signifi-cant differences in signal-to-noise ratio(SNR)between the two groups(t=-1.26,P>0.05)and there were also no statistically significant differences in the subjective evaluation of images(Z=-0.45,P>0.05).Conclusion Measuring children's HC before examination and setting the fixed tube current corresponding to HC grouping can reduce radiation doses while maintaining image qualities.
2.Preliminary study of small intestinal manometry on gastrointestinal motility disorders
Lianhe ZHANG ; Bangjian BIAN ; Xin JIN ; Hongjie GUO ; Jian WANG
Chinese Journal of Postgraduates of Medicine 2024;47(1):13-18
Objective:To investigate the significance of small intestinal manometry in clinical diagnosis and treatment of patients with gastrointestinal motility disorders.Methods:The clinical data of 20 suspected patients with gastrointestinal motility disorders from February 2019 to January 2020 in Shanghai Jiaotong University Affiliated Ninth People′s Hospital were retrospectively analyzed. All patients were performed small intestinal manometry, and the influence on diagnosis and treatment as well as the clinical value of this technique were analyzed.Results:Among the 20 patients, 18 patients successfully accepted small intestinal manometry. Among the 18 patients, 14 patients showed significant motility abnormalities, among which 9 patients showed significant nutritional improvement after treatment and 5 patients were treated with maintaining nutritional support. In 10 patients, small intestinal manometry served as a deciding diagnostic tool, and in 12 patients, major modifications of treatment strategy were made according to results of small intestinal manometry.Conclusions:The small intestinal manometry significantly improves diagnosis and treatment decision in the patients with gastrointestinal motility disorders and shows great value on the clinical practice on this group of patients.
3.Analysis of 13 cases of enteric dysmotility
Hongjie GUO ; Bangjian BIAN ; Xin JIN ; Lianhe ZHANG ; Jian WANG
Chinese Journal of Postgraduates of Medicine 2024;47(1):18-22
Objective:To investigate the clinical characters of enteric dysmotility (ED), in order to improve clinical diagnosis and treatment capabilities.Methods:The clinical data of 13 ED patients underwent small intestinal manometry from August 2019 to July 2022 in the Shanghai Jiaotong University Affiliated Ninth People′s Hospital and the Fourth Affiliated Hospital of Nanjing Medical University were retrospectively analyzed, including the clinical manifestation, small intestinal manometry result, treatment and prognosis.Results:Among 13 patients, 1 abnormality was presented in 9 cases, 2 abnormalities presented in 2 cases and 3 abnormalities presented in 2 cases. All 13 cases presented a history of constipation, 5 cases started with constipation and underwent subtotal colectomy. Three patients showed severe chronic abdominal pain with one of them opiate dependence. Eight patients underwent surgical treatment, all of which achieved nutritional improvement and symptom relief.Conclusions:ED is a concisely defined disease with clear diagnostic criteria. The surgery can increase the symptoms of some patients.
4.The treatment of bundling bone fragment with figure-of-eight suture through double bone tunnels in the chronic bong mallet finger
Qiting JIANG ; Zhi LI ; Jian CHENG ; Fuping QIU ; Bing HE ; Bin WANG ; Lingling YANG ; Tao LI ; Jian BIAN
Chinese Journal of Plastic Surgery 2024;40(1):319-325
Objective:To discuss the clinical curative effect of the treatment of bundling bone fragment with figure-of-eight suture through double bone tunnels in the chronic bong mallet finger.Methods:A retrospective analysis was performed on patients with chronic bong mallet fingers who underwent surgery in the Department of Hand and Foot Microsurgery of Nanjing Jiangbei Hospital from May 2021 to February 2023. During the procedure, made into transverse double bone tunnels on the base of the distal phalanx with 0. 8 mm Kirschner wire, bundling bone fragment with figure-of-eight suture through double bone tunnels, then fixed with Kirschner wire elastic compression. Removal of the Kirschner wire 3 weeks after the procedure, the active flexion and extension range of the joints of the affected finger and the corresponding finger were measured at the last follow-up, then the range of motion (ROM) of the distal interphalangeal joint (DIPJ) and total action movement (TAM) of the fingers (affected and healthy finger) were recorded. The curative effects were evaluated according to the TAM system of the American Association of Hand Surgeons, including 4 grades: excellent, good, fair, and poor. SPSS 13. 0 software was used for statistical analysis of the data, and the measurement data conforming to normal distribution were expressed as Mean ± SD. The ROM of DIPJ and TAM of the affected finger were compared with the corresponding healthy finger 6 months after surgery by a paired sample t test. P<0. 05 indicates that the difference is statistically significant. Results:A total of 30 patients (30 digits) were enrolled, including 19 males and 11 females, and the age ranged from 18 to 62 years old, with an average age of 31 years old. The time from injury to operation was 24 to 65 days (mean of 35 days) . According to Wehbe and Schneider classification, there were 8 cases of type Ⅰa, 6 cases of type Ⅰb, 7 cases of type Ⅱa, 5 cases of type Ⅱb, 2 cases of type Ⅲa and 2 cases of type Ⅲb. All incisions healed well, the intraoperative blood loss was minimal, with no infection. All 30 cases were followed up for 6 to 7 months. All fractures were well aligned and healed, malformed fingers were completely corrected, and no needle tunnel infection or needle breakage were observed. At the last follow-up, the differences of the ROM of the DIPJ [ (30. 2±3. 5) °vs. (30. 4±3. 3) °, t=2. 57, P=0. 463] and the TAM [ (235. 3± 3. 6) ° vs. (237. 7± 4. 2) °, t=1. 78, P= 0. 247 ] between the affected and healthy fingers were not statistically significant. Finger function assessment: 27 cases were excellent, and 3 cases were good, and the excellent and good rate was 100%. Conclusion:Satisfactory therapeutic outcome for the treatment of chronic bong mallet finger deformity can be achieved by bundling bone fragment with figure-of-eight suture through double bone tunnels. It is an effective and practical method.
5.The treatment of bundling bone fragment with figure-of-eight suture through double bone tunnels in the chronic bony mallet finger
Qiting JIANG ; Fuping QIU ; Bing HE ; Jian CHENG ; Bin WANG ; Lingling YANG ; Jian BIAN
Chinese Journal of Plastic Surgery 2024;40(6):634-640
Objective:To discuss the clinical curative effect of the treatment of bundling bone fragment with figure-of-eight suture through double bone tunnels in the chronic bony mallet finger.Methods:A retrospective analysis was performed on patients with chronic bony mallet fingers who underwent surgery in the Department of Hand and Foot Microsurgery of Nanjing Jiangbei Hospital from May 2021 to February 2023. During the procedure, made into transverse double bone tunnels on the base of the distal phalanx with 0.8 mm Kirschner wire, bundling bone fragment with figure-of-eight suture through double bone tunnels, then fixed with Kirschner wire elastic compression. Removal of the Kirschner wire 3 weeks after the procedure, the active flexion and extension range of the joints of the affected finger and the corresponding finger were measured at the last follow-up, then the range of motion (ROM) of the distal interphalangeal joint (DIPJ) and total action movement (TAM) of the fingers (affected and healthy finger) were recorded. The curative effects were evaluated according to the TAM system of the American Association of Hand Surgeons, including 4 grades: excellent, good, fair, and poor. SPSS 13.0 software was used for statistical analysis of the data, and the measurement data conforming to normal distribution were expressed as Mean±SD. The ROM of DIPJ and TAM of the affected finger were compared with the corresponding healthy finger 6 months after surgery by a paired sample t-test. P<0.05 indicated that the difference was statistically significant. Results:A total of 30 patients (30 digits) were enrolled, including 19 males and 11 females, and the age ranged from 18 to 62 years old, with an average age of 31 years old. The time from injury to operation was 24 to 65 days (mean of 35 days). According to Wehbe and Schneider classification, there were 8 cases of type Ⅰa, 6 cases of type Ⅰb, 7 cases of type Ⅱa, 5 cases of type Ⅱb, 2 cases of type Ⅲa and 2 cases of type Ⅲb. All incisions healed well, the intraoperative blood loss was minimal, with no infection. All 30 cases were followed up for 6 to 7 months. All fractures were well aligned and healed, malformed fingers were completely corrected, and no needle tunnel infection or needle breakage were observed. At the last follow-up, the differences of the ROM of the DIPJ [(30.2±3.5)° vs. (30.4±3.3)°, t=2.57, P=0.463] and the TAM [(235.3±3.6)° vs. (237.7±4.2)°, t=1.78, P=0.247] between the affected and healthy fingers were not statistically significant. Finger function assessment: 27 cases were excellent, and 3 cases were good, and the excellent and good rate was 100%. Conclusion:Satisfactory therapeutic outcome for the treatment of chronic bony mallet finger deformity can be achieved by bundling bone fragment with figure-of-eight suture through double bone tunnels. It is an effective and practical method.
6.Combination therapy of the minimally invasive percutaneous quantitative suture technique eight times and Kirschner wire elastic fixation in the treatment of mallet finger
Qiting JIANG ; Xiang YAO ; Fuping QIU ; Bing HE ; Lei ZHANG ; Bin WANG ; Jian BIAN
Chinese Journal of Plastic Surgery 2024;40(10):1086-1092
Objective:To discuss the clinical curative effect and feasibility of the combination therapy of the minimally invasive percutaneous quantitative suture technique eight times and Kirschner wire elastic fixation in the treatment of mallet finger.Methods:A retrospective analysis was performed on patients with tendon zone Ⅰ rupture of tendinous mallet fingers who underwent surgery in the Department of Hand and Foot Microsurgery of Nanjing Jiangbei Hospital from July 2021 to June 2023. During the procedure, firstly, the extensor digitalis tendon in the zone Ⅰ was sutured percutaneous with 3-0 thread monofilament sutures in the "quantitative 8-stitch method " according to the pre-marked number sequence of 1 to 8, and fixed at the base of the distal phalanx via a constructed bone tunnel. Secondly, the distal interphalangeal joint (DIPJ) was fixed elastically with Kirschner wire, without damage to the articular surface. Four to five weeks after the operation, the Kirschner wire was removed, and flexion and extension of the affected finger were gradually increased. At the last follow-up, the range of motion (ROM) and the total action motion (TAM) of the finger were recorded, and the healthy side of the ROM and TAM slightly differed. Finger function was evaluated following the American Association of Hand Surgeons TAM system. It was divided into four grades: excellent, good, fair and poor. SPSS 15.0 software was used for statistical analysis. Measurement data conforming to normal distribution were expressed as Mean±SD, and a paired sample t-test was used for comparison between the affected finger and the corresponding healthy finger. Results:A total of 30 patients (30 digits) were enrolled, including 19 males and 11 females with the age of (38.5±4.3) years (14 to 71 years). All were single closed injuries. Time from injury to operation was (1.1±0.4) d (3 h to 7 d). The distance of tendon break was (8.4±0.5) mm (4 to 12 mm). Mallet finger deformities were all corrected postoperatively. There were no complications such as scar, exposed suture, nail tract infection, or nail removal on the dorsal side of the affected finger. All patients were followed up for (7.5±1.3) months (6-13 months). At the last follow-up, the ROM of DIPJ of the affected finger and the corresponding healthy finger were 43.28°±2.03° and 44.15°±1.12°, respectively, with no statistical significance ( t=1.32, P=0.084). TAM of the affected finger and the corresponding healthy finger were 240.15°±5.13° and 242.13°±3.11°, respectively, with no significant difference ( t=2.12, P=0.135). According to TAM system evaluation criteria, excellent in 27 cases, good in 3 cases, excellent and good rate was 100% (30/30). Conclusion:The combination of the minimally invasive percutaneous quantitative suture technique eight times and Kirschner wire elastic fixation has a satisfactory treatment outcome in the mallet finger, and there is no damage to the DIPJ surface. It is a simple, safe, effective method with minimal invasion.
7.Analysis of Specific Chromatogram of Classical Formula Qianghuo Shengshi Tang Reference Samples
Wenya GAO ; He XU ; Mingli LI ; Haiyu ZHAO ; Yanyan ZHOU ; Hongjie WANG ; Jian YANG ; Xiaolu WEI ; Zhikun FAN ; Nan SI ; Baolin BIAN
Chinese Journal of Modern Applied Pharmacy 2024;41(10):1350-1356
OBJECTIVE
To establish the specific chromatogram of Qianghuo Shengshi Tang(QHSS) reference sample, clarify the key quality attributes of QHSS, providing reference for the quality evaluation of QHSS reference sample.
METHODS
The SilGreen C18 column(4.6 mm×250 mm, 5 μm) was used. The mobile phase consisted acetonitrile and 0.2% formic acid aqueous solution. The detection wavelength was 328 nm. Established an HPLC characteristic spectrum analysis method for the reference sample of QHSS. A variety of chromatographic columns and different instruments were applied to investigate the adaptability of the system. HPLC-LTQ-Orbitrap MS was used to identify the specific peaks of the QHSS reference samples in positive ion mode.
RESULTS
There were 14 peaks in the specific chromatogram, which belonged to Notopterygii Rhizoma Et Radix, Angelicae Pubescentis Radix, Ligustici Rhizoma Et Radix, Chuanxiong Rhizome, Viticis Fructus, respectively. Ferulic acid(peak 3) was reference peak. A total of 22 compounds were identified by mass spectrometry, including coumarin and flavonoids.
CONCLUSION
The established specific chromatogram method of QHSS is simple, stable and reproducible. The material basis of QHSS reference sample is basically determined, providing a reference for the development and quality control of QHSS.
8.Application of 3D-T1WI surface-based morphometry in assessment of brain structure in preschool children with non-lesional epilepsy
Jian-Qiu JIANG ; Nan ZHANG ; Peng ZHANG ; Chuan-Zhen BIAN
Chinese Medical Equipment Journal 2024;45(2):62-66
Objective To evaluate the changes of brain structure in preschool children with non-lesional epilepsy(NLE)by analyzing their 3D-T1WI brain structural images with surface-based morphometry(SBM).Methods Thirty-five preschool children with diagnosed NLE in the neurology department of some hospital from January 2021 to September 2022 were enrolled into a NLE group,and 35 healthy preschool children from the same period were included in a control group.The two groups were compared in terms of cortical thickness,sulcus depth,gyrus index,cerebrospinal fluid volume,gray matter volume and white matter volume.SPSS 25.0 software was used for statistical analysis.Results When compared with the control group,the NLE group had the thicknesses of temporal lobe cortex decreased at both left and right sides while the thickness of cingulate cortex increased on the right,and the differences were statistically significant(P<0.05);the NLE group had the depths of sulcus in lingual gyrus and middle frontal gyrus of right cerebral hemisphere reduced,and the differences were statistically significant(P<0.05);the NLE group had the gyrus index of left cerebral hemisphere talus cortex highered,and the differences were statistically significant(P<0.05).There were no significant differences between the two groups in cerebrospinal fluid,gray matter and white matter(P>0.05).Conclusion Cortical structural abnormalities in children with NLE may be a major factor in its pathogenesis.SBM can be used to evaluate localized brain structural abnormalities in NLE children by analyzing their 3D-T1WI brain structural images,and thus can be an effective tool for determining the potential pathogenesis of NLE in children.[Chinese Medical Equipment Journal,2024,45(2):62-66]
9.Correlation between CT-based arterial radiomics score and the neo-adjuvant treatment response of pancreatic cancer
Mengmeng ZHU ; Yun BIAN ; Chengwei CHEN ; Jian ZHOU ; Na LI ; Yifei GUO ; Ying LI ; Xiaohan YUAN ; Jieyu YU ; Jianping LU
Chinese Journal of Pancreatology 2024;24(3):190-197
Objective:To identify the relationship between the CT arterial radiomics score and the treatment response to neoadjuvant therapy for pancreatic cancer.Methods:The clinical data of 243 pancreatic cancer patients who received surgical resection after neo-adjuvant therapy in the First Affiliated Hospital of Naval Medical University from March 2017 to March 2023 were retrospectively analyzed. Based on the tumor regression grade (TRG), the patients were divided into good response group (TRG 0-1, n=30) and non-good response group (TRG 2-3, n=213). The clinical, radiological and pathological features were compared between two groups. Fully-automated segmentation tool was used for segmenting the arterial CT scan of pancreatic tumor before and after treatment. Python package was applied to extract the radiomics features of tumors after segmentation and the extracted features were reduced and chosen using the least absolute shrinkage and selection operator (Lasso) logistic regression algorithm. Lasso logistic regression formula was applied to calculate the arterial radiomics score. Univariate and multivariate logistic regression models were used to analyze the association between arterial radiomics score and treatment response to neoadjucant therapy. Receiver operating-characteristics (ROC) curve was drawn and area under curve (AUC), specificity, sensitivity and accuracy for evaluating the treatment response were calculated. The clinical usefulness of arterial radiomics score for diagnosing the response of neoadjuvant treatment for pancreatic cancer were determined by decision curve analysis (DCA) . Results:A total of 330 arterial radiomics CT features were obtained, and 9-selected arterial phase features associated with treatment response were determined after being reduced by the Lasso logistic regression algorithm. Univariate analysis showed that the arterial radiomics score, three-dimensional diameter after neoadjuvant therapy, pancreatic contour, T stage, N stage, Peri-pancreatic nerve invasion, lymph-vascular space invasion (LVSI) and invasion of duodenum were all associated with treatment response (all P value <0.05). Multivariate logistic regression analyses confirmed that arterial radiomics score was obviously associated with the neoadjuvant treatment response ( P<0.001). At the cut-off value of 1.93, AUC of the arterial radiomics score for diagnosing neoadjuvant treatment response was 0.92, and the specificity, sensitivity and accuracy was 86.7%, 84.5% and 84.8%. DCA demonstrated that when the percentage for predicting the treatment response by using the arterial radiomics score was >0.2, the patients could benefit from the application of arterial radiomics score for evaluating neoadjuvant therapy response. Conclusions:The arterial radiomics score was strongly correlated with the neoadjuvant treatment response of pancreatic cancer, and can accurately predict neoadjuant treatment efficacy.
10.Detection of Copper Ion in Water Based on a Method Combining Potentiometric and Amperometric Sensors for Accurate Measurement
Ao-Bo CONG ; Yang LI ; Hai-Fei ZHAO ; Jian-Hua TONG ; Chao BIAN
Chinese Journal of Analytical Chemistry 2024;52(8):1163-1171
In this study,a method for detecting heavy metal ions using potentiometric sensor and voltammetric sensor was proposed.By exploiting the complementary advantages of potentiometric and voltammetric electrochemical sensor,the traditional electrochemical electrode without special material preparation and modification could be used for the wide range and accurate detection of heavy metal ions in actual water samples.During detection,the concentration of target ion was measured by a potentiometric electrochemical sensor to determine the concentration range.The amperometric electrochemical sensor was then used for calibration and accurate measurement in the appropriate concentration range.Taking copper ion(Cu2+)as an example,the prepared Cu2+water sample and the actual water sample were tested.First,the copper ion selective electrode was used to determine the concentration range of Cu2+in the sample.Then,based on the gold electrode in different concentration range(0.86-100 μg/L and 100-300 μg/L)using two different optimization parameter settings to calibrate the electrochemical sensor and measure,the test results had a good correlation with those by professional water quality testing institutions.The recoveries ranged from 86.7%to 103.0%.The experimental results showed that the combination of potential sensor and current sensor could improve the accuracy of detection of heavy metal ions in water samples by electrochemical sensor.


Result Analysis
Print
Save
E-mail