1.Principles, technical specifications, and clinical application of lung watershed topography map 2.0: A thoracic surgery expert consensus (2024 version)
Wenzhao ZHONG ; Fan YANG ; Jian HU ; Fengwei TAN ; Xuening YANG ; Qiang PU ; Wei JIANG ; Deping ZHAO ; Hecheng LI ; Xiaolong YAN ; Lijie TAN ; Junqiang FAN ; Guibin QIAO ; Qiang NIE ; Mingqiang KANG ; Weibing WU ; Hao ZHANG ; Zhigang LI ; Zihao CHEN ; Shugeng GAO ; Yilong WU
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(02):141-152
With the widespread adoption of low-dose CT screening and the extensive application of high-resolution CT, the detection rate of sub-centimeter lung nodules has significantly increased. How to scientifically manage these nodules while avoiding overtreatment and diagnostic delays has become an important clinical issue. Among them, lung nodules with a consolidation tumor ratio less than 0.25, dominated by ground-glass shadows, are particularly worthy of attention. The therapeutic challenge for this group is how to achieve precise and complete resection of nodules during surgery while maximizing the preservation of the patient's lung function. The "watershed topography map" is a new technology based on big data and artificial intelligence algorithms. This method uses Dicom data from conventional dose CT scans, combined with microscopic (22-24 levels) capillary network anatomical watershed features, to generate high-precision simulated natural segmentation planes of lung sub-segments through specific textures and forms. This technology forms fluorescent watershed boundaries on the lung surface, which highly fit the actual lung anatomical structure. By analyzing the adjacent relationship between the nodule and the watershed boundary, real-time, visually accurate positioning of the nodule can be achieved. This innovative technology provides a new solution for the intraoperative positioning and resection of lung nodules. This consensus was led by four major domestic societies, jointly with expert teams in related fields, oriented to clinical practical needs, referring to domestic and foreign guidelines and consensus, and finally formed after multiple rounds of consultation, discussion, and voting. The main content covers the theoretical basis of the "watershed topography map" technology, indications, operation procedures, surgical planning details, and postoperative evaluation standards, aiming to provide scientific guidance and exploration directions for clinical peers who are currently or plan to carry out lung nodule resection using the fluorescent microscope watershed analysis method.
2.Research advances in the disease burden of viral hepatitis in China
Jian LI ; Fuzhen WANG ; Zhongdan CHEN ; Jinlei QI ; Ailing WANG ; Fanghui ZHAO ; Yuanyuan KONG ; Jing SUN ; Jiaqi KANG ; Zundong YIN ; Zhongfu LIU ; Jidong JIA ; Yu WANG
Journal of Clinical Hepatology 2025;41(2):221-227
Over the past three decades, China has made significant progress in the prevention and control of viral hepatitis, and the incidence rates of new-onset pediatric hepatitis B virus infections and acute viral hepatitis in the population have reduced to a relatively low level; however, there is still a heavy disease burden of chronic viral hepatitis in China, which severely affects the health status of the population. This study systematically summarizes the achievements of viral hepatitis prevention and control in China, analyzes existing problems and challenges, and proposes comprehensive prevention and control strategies and measures to eliminate viral hepatitis as a public health threat based on the national conditions of China, in order to provide a reference for related departments in China on how to achieve the action targets for eliminating viral hepatitis as a public health threat by 2030.
3.Neurotrophin-3 receptor switching promotes neural functional recovery in rats after spinal cord injury
Yan CONG ; Jian YU ; Zhide SUN ; Dawei KANG
Chinese Journal of Tissue Engineering Research 2025;29(11):2268-2276
BACKGROUND:Neurotrophins represent a novel therapeutic approach for spinal cord injury,showing promising clinical applicability.Autophagy modulation is one of the mechanisms by which neurotrophins exert their effects,yet the specific signaling pathways involved remain unclear. OBJECTIVE:To explore how neurotrophin-3(NT-3)modulates autophagy in oligodendrocytes via switching between P75NTR and TrkC receptors and promotes neurological function recovery after spinal cord injury,aiming to further clarify the specific molecular mechanisms involved. METHODS:Twenty-four Sprague-Dawley rats were randomly divided into three groups:sham operation,spinal cord injury,and NT-3 groups.The therapeutic effect of NT-3 on spinal cord injury in rats was evaluated using the Basso,Beattie,and Bresnahan locomotor rating scale.The expression levels of NT-3,Olig1,myelin basic protein,and the autophagy marker LC3B in rat spinal cord tissue were detected by western blot.In a cellular experiment,oligodendrocytes were cultured in vitro and divided into six groups:oxygen-glucose deprivation(OGD),OGD+NT-3,OGD+NT-3+P75NTR plasmid,OGD+NT-3+TrkC plasmid,OGD+3-methyladenine(an autophagy inhibitor),and OGD+rapamycin(an autophagy activator).Oligodendrocyte morphology was observed under a light microscope,cell apoptosis was assessed by TUNEL staining,and the expression of TrkC receptor,P75NTR,LC3B,and the phosphorylation status of the PI3K/AKT/mTOR and AMPK/mTOR signaling pathways were evaluated by western blot. RESULTS AND CONCLUSION:Animal experiments demonstrated that compared with the sham operation group,NT-3 expression significantly increased after spinal cord injury(P<0.05);exogenous NT-3 treatment accelerated neurological function recovery in rats post spinal cord injury(P<0.05)and increased the expression of Olig1 and myelin basic proteins(P<0.05).Cellular experiments revealed that 3 hours marked the early to middle/late phase transition.Compared with the OGD group,oligodendrocytes in the OGD+NT-3 group could maintain their morphology for a longer period of time,TrkC receptor expression was lower in the early phase and significantly upregulated in the middle/late phase(P<0.05),whereas P75NTR protein expression was upregulated in the early phase and downregulated in the middle/late phase(P<0.05),and autophagy levels showed an initial increase followed by a decrease(P<0.05).By comparing the morphology and TUNEL staining results of cells in the OGD+NT-3,OGD+rapamycin,and OGD+3-methyladenine groups,we found that either promoting or inhibiting autophagy alone had adverse effects on oligodendrocyte survival,whereas modulating autophagy in a manner similar to NT-3 could maximally maintain cell survival.NT-3 could promote autophagy in the early phase via the P75NTR/AMPK/mTOR signaling pathway and inhibit autophagy in the later phase through the TrkC/PI3K/AKT/mTOR signaling pathway.Based on these findings,it is concluded that NT-3 can bidirectionally regulate autophagy in oligodendrocytes through the switching of P75NTR/TrkC receptors,thereby maintaining cell survival and facilitating the recovery of neurological functions in rats after spinal cord injury.
4.Chinese expert consensus on postoperative follow-up for non-small cell lung cancer (version 2025)
Lunxu LIU ; Shugeng GAO ; Jianxing HE ; Jian HU ; Di GE ; Hecheng LI ; Mingqiang KANG ; Fengwei TAN ; Fan YANG ; Qiang PU ; Kaican CAI
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(03):281-290
Surgical treatment is one of the key approaches for non-small cell lung cancer (NSCLC). Regular postoperative follow-up is crucial for early detection and timely management of tumor recurrence, metastasis, or second primary tumors. A scientifically sound and reasonable follow-up strategy not only extends patient survival but also significantly improves quality of life, thereby enhancing overall prognosis. This consensus aims to build upon the previous version by incorporating the latest clinical research advancements and refining postoperative follow-up protocols for early-stage NSCLC patients based on different treatment modalities. It provides a scientific and practical reference for clinicians involved in the postoperative follow-up management of NSCLC. By optimizing follow-up strategies, this consensus seeks to promote the standardization and normalization of lung cancer diagnosis and treatment in China, helping more patients receive high-quality care and long-term management. Additionally, the release of this consensus is expected to provide insights for related research and clinical practice both domestically and internationally, driving continuous development and innovation in the field of postoperative management for NSCLC.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
9.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
10.Improvement effect and mechanism of Shengmai powder on heart failure mice with qi-yin deficiency
Lanfang KANG ; Jian LI ; Yating ZHAO ; Yingchun CHEN ; Guiyin CHEN ; Xiaobo NIE ; Jiao LIU ; Jie CHENG
China Pharmacy 2025;36(17):2127-2133
OBJECTIVE To study the improvement effect and mechanism of Shengmai powder on heart failure (HF) mice with qi-yin deficiency. METHODS The mice were randomly divided into blank group (water), model group (water), Shengmai powder low-, medium-, and high-dose groups [2.61, 5.22 and 10.44 g/kg (based on crude drug dosage)] and positive control group (metoprolol, 30 mg/kg), with 10 mice in each group. Except for the blank group, all other groups were subcutaneously injected with D-galactose, and a qi-yin deficiency HF mice model was established by continuous food restriction and weight-bearing swimming. At the same time of modeling, the corresponding medicine/water was gavaged once a day for five weeks. The general state of mice was recorded and the traditional Chinese medicine (TCM) syndrome score was evaluated. Behavioral experiments were conducted to investigate the total distance of open field action, the percentage of immobility time, and the swimming exhaustion time of mice. The contents of aspartate transaminase (AST), creatine kinase (CK) and lactate dehydrogenase (LDH) in the serum of mice were detected; cardiac function indexes [heart rate, left ventricular ejection fraction (LVEF), left ventricular end systolic diameter (LVESD), left ventricular end diastolic diameter (LVEDD), left ventricular mass index and whole heart mass index] were all detected; the histopathological morphology of mice myocardium was observed; the level of cardiomyocyte apoptosis in mice was detected; mRNA expression levels of B-cell lymphoma 2 (Bcl-2), Bcl-2 associated X protein (Bax), and Cleaved-caspase-3 in myocardial tissue of mice were detected; the phosphorylation levels of sarcoplasmic reticulum calcium regulatory related proteins [ryanodine receptor 2 (RyR2) and phospholamban (PLB)] in myocardial tissue of mice were detected. RESULTS Compared with the blank group, the body weight, total distance of open field action, swimming exhaustion time, LVEF, LVEDD, Bcl-2 mRNA expression level in myocardial tissue and PLB protein phosphorylation level in the model group were significantly reduced/shortened (P<0.05); TCM syndrome score, the percentage of immobility time, heart rate, LVESD, left ventricular mass index, whole heart mass index, cardiomyocyte apoptosis rate, the contents of CK, LDH and AST in serum, mRNA expression levels of Cleaved-caspase-3 and Bax and the phosphorylation level of RyR2 protein in myocardial tissue were significantly increased (P<0.05); there were inflammatory cell infiltration, disordered cell arrangement and obvious myocardial interstitial fibrosis in myocardial tissue. After the intervention of Shengmai powder, most of the above quantitative indexes in mice were significantly reversed (P<0.05), the inflammatory cell infiltration in myocardial tissue was reduced, and the degree of fibrosis was significantly reduced. CONCLUSIONS Shengmai powder can improve cardiac function, reduce the level of cardiomyocyte apoptosis and myocardial fibrosis in HF mice with qi-yin deficiency. Its mechanism may be related to the regulation of the expression of sarcoplasmic reticulum calcium regulation related proteins.

Result Analysis
Print
Save
E-mail