1.Yttrium-90 selective internal radiation therapy on liver cancer: the past, the present, and the future
Jingqin MA ; Linhong ZHANG ; Minjie YANG ; Jiabin CAI ; Ying FANG ; Rong LIU ; Xudong QU ; Lingxiao LIU ; Zhiping YAN
Chinese Journal of Clinical Medicine 2025;32(1):3-8
Yttrium-90 selective internal radiation therapy (90Y-SIRT) is a treatment technique that delivers radioactive microspheres precisely to the arterial vascular bed of neoplasms, utilizing beta radiation to administer a high local dose of radiation to the neoplasm tissues. This technology has demonstrated significant efficacy in patients with unresectable pirmary liver cancers and liver metastases. This article systematically reviews the development history and clinical application status of 90Y-SIRT in the treatment of liver cancer, and looks forward to future development directions.
2.Analysis of the safety, economic benefit and social psychological satisfaction of day breast conserving surgery for breast cancer
Jiao ZHOU ; Xiaoxiao XIAO ; Jiabin YANG ; Yu FENG ; Huanzuo YANG ; Mengxue QIU ; Qing ZHANG ; Yang LIU ; Mingjun HUANG ; Peng LIANG ; Zhenggui DU
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(02):160-166
Objective To investigate the safety, economic benefits and psychological effects of day breast conserving surgery for breast cancer. Methods The demographic data and clinical data of breast cancer patients undergoing day (day surgery group) and ward (ward surgery group) breast conserving surgeries in West China Hospital of Sichuan University from March 2020 to June 2021 were retrospectively collected; the demographic data, clinical data, medical and related transportation costs, and preoperative and postoperative BREAST-Q scores of breast cancer patients undergoing day (day surgery group) and ward (ward surgery group) breast conserving surgery in West China Hospital of Sichuan University from June 2021 to June 2022 were prospectively collected. The safety, economic benefit, and psychological satisfaction of day surgery was analyzed. Results A total of 42 women with breast cancer were included in the retrospective study and 39 women with breast cancer were included in the prospective study. In both prospective and retrospective studies, the mean age of patients in both groups were <50 years. There were only statistical differences between the two groups in the aspects of hypertension (P=0.022), neoadjuvant chemotherapy (P=0.037) and postoperative pathological estrogen receptor (P=0.033) in the prospective study. In postoperative complications, there were no statistical differences in the surgical-related complications or anesthesia-related complications between the two groups in either the prospective study or the retrospective study (P>0.05). In terms of the overall cost, we found that the day surgery group was more economical than the ward surgery group in the prospective study (P=0.002). There were no statistical differences in postoperative psychosocical well-being, sexual well-being, satisfaction with breasts or chest condition between the two groups (P>0.05). Conclusion It is safe and reliable to carry out breast conserving surgery in day surgery center under strict management standards, which can save medical costs and will not cause great psychological burden to patients.
3.Development of Electrospinning Setup for Vascular Tissue-Engineering Application with Thick-Hierarchical Fiber Alignment
Shen CHEN ; Chao XIE ; Xiaoxi LONG ; Xianwei WANG ; Xudong LI ; Peng LIU ; Jiabin LIU ; Zuyong WANG
Tissue Engineering and Regenerative Medicine 2025;22(2):195-210
BACKGROUND:
Tissue engineering holds promise for vascular repair and regeneration by mimicking the extracellular matrix of blood vessels. However, achieving a functional and thick vascular wall with aligned fiber architecture by electrospinning remains a significant challenge.
METHODS:
A novel electrospinning setup was developed that utilizes an auxiliary electrode and a spring. The impact of process parameters on fiber size and morphology was investigated. The structure and functions of the scaffolds were evaluated through material characterization and assessments of cellular biocompatibility.
RESULTS:
The new setup enabled controlled deposition of fibers in different designed orientations. The fabricated small-diameter vascular scaffolds consisted of an inner layer of longitudinally oriented fibers and an outer layer of circumferentially oriented fibers (L + C vascular scaffold). Key parameters, including rotational speed, the utilization of the auxiliary electrode, and top-to-collector distance (TCD) significantly influenced fiber orientation. Additionally, voltage, TCD, feed rate, needle size, auxiliary electrode and collector-auxiliary electrode distance affected fiber diameter and distribution. Mechanical advantages and improved surface wettability of L + C vascular scaffold were confirmed through tensile testing and water contact angle. Cellular experiments indicated that L + C vascular scaffold facilitated cell adhesion and proliferation, with human umbilical vein endothelial cells and smooth muscle cells attaching and elongating along the fiber direction of the inner and outer layer, respectively.
CONCLUSION
This study demonstrated the feasibility of fabricating fiber-aligned, thick-walled vascular scaffolds using a modified electrospinning setup. The findings provided insights into how the auxiliary electrode, specific collector influenced fiber deposition, potentially advancing biomimetic vascular scaffold engineering.
4.Development of Electrospinning Setup for Vascular Tissue-Engineering Application with Thick-Hierarchical Fiber Alignment
Shen CHEN ; Chao XIE ; Xiaoxi LONG ; Xianwei WANG ; Xudong LI ; Peng LIU ; Jiabin LIU ; Zuyong WANG
Tissue Engineering and Regenerative Medicine 2025;22(2):195-210
BACKGROUND:
Tissue engineering holds promise for vascular repair and regeneration by mimicking the extracellular matrix of blood vessels. However, achieving a functional and thick vascular wall with aligned fiber architecture by electrospinning remains a significant challenge.
METHODS:
A novel electrospinning setup was developed that utilizes an auxiliary electrode and a spring. The impact of process parameters on fiber size and morphology was investigated. The structure and functions of the scaffolds were evaluated through material characterization and assessments of cellular biocompatibility.
RESULTS:
The new setup enabled controlled deposition of fibers in different designed orientations. The fabricated small-diameter vascular scaffolds consisted of an inner layer of longitudinally oriented fibers and an outer layer of circumferentially oriented fibers (L + C vascular scaffold). Key parameters, including rotational speed, the utilization of the auxiliary electrode, and top-to-collector distance (TCD) significantly influenced fiber orientation. Additionally, voltage, TCD, feed rate, needle size, auxiliary electrode and collector-auxiliary electrode distance affected fiber diameter and distribution. Mechanical advantages and improved surface wettability of L + C vascular scaffold were confirmed through tensile testing and water contact angle. Cellular experiments indicated that L + C vascular scaffold facilitated cell adhesion and proliferation, with human umbilical vein endothelial cells and smooth muscle cells attaching and elongating along the fiber direction of the inner and outer layer, respectively.
CONCLUSION
This study demonstrated the feasibility of fabricating fiber-aligned, thick-walled vascular scaffolds using a modified electrospinning setup. The findings provided insights into how the auxiliary electrode, specific collector influenced fiber deposition, potentially advancing biomimetic vascular scaffold engineering.
5.Development of Electrospinning Setup for Vascular Tissue-Engineering Application with Thick-Hierarchical Fiber Alignment
Shen CHEN ; Chao XIE ; Xiaoxi LONG ; Xianwei WANG ; Xudong LI ; Peng LIU ; Jiabin LIU ; Zuyong WANG
Tissue Engineering and Regenerative Medicine 2025;22(2):195-210
BACKGROUND:
Tissue engineering holds promise for vascular repair and regeneration by mimicking the extracellular matrix of blood vessels. However, achieving a functional and thick vascular wall with aligned fiber architecture by electrospinning remains a significant challenge.
METHODS:
A novel electrospinning setup was developed that utilizes an auxiliary electrode and a spring. The impact of process parameters on fiber size and morphology was investigated. The structure and functions of the scaffolds were evaluated through material characterization and assessments of cellular biocompatibility.
RESULTS:
The new setup enabled controlled deposition of fibers in different designed orientations. The fabricated small-diameter vascular scaffolds consisted of an inner layer of longitudinally oriented fibers and an outer layer of circumferentially oriented fibers (L + C vascular scaffold). Key parameters, including rotational speed, the utilization of the auxiliary electrode, and top-to-collector distance (TCD) significantly influenced fiber orientation. Additionally, voltage, TCD, feed rate, needle size, auxiliary electrode and collector-auxiliary electrode distance affected fiber diameter and distribution. Mechanical advantages and improved surface wettability of L + C vascular scaffold were confirmed through tensile testing and water contact angle. Cellular experiments indicated that L + C vascular scaffold facilitated cell adhesion and proliferation, with human umbilical vein endothelial cells and smooth muscle cells attaching and elongating along the fiber direction of the inner and outer layer, respectively.
CONCLUSION
This study demonstrated the feasibility of fabricating fiber-aligned, thick-walled vascular scaffolds using a modified electrospinning setup. The findings provided insights into how the auxiliary electrode, specific collector influenced fiber deposition, potentially advancing biomimetic vascular scaffold engineering.
6.Development of Electrospinning Setup for Vascular Tissue-Engineering Application with Thick-Hierarchical Fiber Alignment
Shen CHEN ; Chao XIE ; Xiaoxi LONG ; Xianwei WANG ; Xudong LI ; Peng LIU ; Jiabin LIU ; Zuyong WANG
Tissue Engineering and Regenerative Medicine 2025;22(2):195-210
BACKGROUND:
Tissue engineering holds promise for vascular repair and regeneration by mimicking the extracellular matrix of blood vessels. However, achieving a functional and thick vascular wall with aligned fiber architecture by electrospinning remains a significant challenge.
METHODS:
A novel electrospinning setup was developed that utilizes an auxiliary electrode and a spring. The impact of process parameters on fiber size and morphology was investigated. The structure and functions of the scaffolds were evaluated through material characterization and assessments of cellular biocompatibility.
RESULTS:
The new setup enabled controlled deposition of fibers in different designed orientations. The fabricated small-diameter vascular scaffolds consisted of an inner layer of longitudinally oriented fibers and an outer layer of circumferentially oriented fibers (L + C vascular scaffold). Key parameters, including rotational speed, the utilization of the auxiliary electrode, and top-to-collector distance (TCD) significantly influenced fiber orientation. Additionally, voltage, TCD, feed rate, needle size, auxiliary electrode and collector-auxiliary electrode distance affected fiber diameter and distribution. Mechanical advantages and improved surface wettability of L + C vascular scaffold were confirmed through tensile testing and water contact angle. Cellular experiments indicated that L + C vascular scaffold facilitated cell adhesion and proliferation, with human umbilical vein endothelial cells and smooth muscle cells attaching and elongating along the fiber direction of the inner and outer layer, respectively.
CONCLUSION
This study demonstrated the feasibility of fabricating fiber-aligned, thick-walled vascular scaffolds using a modified electrospinning setup. The findings provided insights into how the auxiliary electrode, specific collector influenced fiber deposition, potentially advancing biomimetic vascular scaffold engineering.
7.Development of Electrospinning Setup for Vascular Tissue-Engineering Application with Thick-Hierarchical Fiber Alignment
Shen CHEN ; Chao XIE ; Xiaoxi LONG ; Xianwei WANG ; Xudong LI ; Peng LIU ; Jiabin LIU ; Zuyong WANG
Tissue Engineering and Regenerative Medicine 2025;22(2):195-210
BACKGROUND:
Tissue engineering holds promise for vascular repair and regeneration by mimicking the extracellular matrix of blood vessels. However, achieving a functional and thick vascular wall with aligned fiber architecture by electrospinning remains a significant challenge.
METHODS:
A novel electrospinning setup was developed that utilizes an auxiliary electrode and a spring. The impact of process parameters on fiber size and morphology was investigated. The structure and functions of the scaffolds were evaluated through material characterization and assessments of cellular biocompatibility.
RESULTS:
The new setup enabled controlled deposition of fibers in different designed orientations. The fabricated small-diameter vascular scaffolds consisted of an inner layer of longitudinally oriented fibers and an outer layer of circumferentially oriented fibers (L + C vascular scaffold). Key parameters, including rotational speed, the utilization of the auxiliary electrode, and top-to-collector distance (TCD) significantly influenced fiber orientation. Additionally, voltage, TCD, feed rate, needle size, auxiliary electrode and collector-auxiliary electrode distance affected fiber diameter and distribution. Mechanical advantages and improved surface wettability of L + C vascular scaffold were confirmed through tensile testing and water contact angle. Cellular experiments indicated that L + C vascular scaffold facilitated cell adhesion and proliferation, with human umbilical vein endothelial cells and smooth muscle cells attaching and elongating along the fiber direction of the inner and outer layer, respectively.
CONCLUSION
This study demonstrated the feasibility of fabricating fiber-aligned, thick-walled vascular scaffolds using a modified electrospinning setup. The findings provided insights into how the auxiliary electrode, specific collector influenced fiber deposition, potentially advancing biomimetic vascular scaffold engineering.
8.Analysis of the correlation between work-related musculoskeletal disorders and occupational stress in electronic manufacturing workers
Huiqing CHEN ; Xiaoyi LI ; Manqi HUANG ; Yao GUO ; Xiaoman LIU ; Jiabin CHEN
China Occupational Medicine 2024;51(1):81-84
ObjectiveTo explore the effect of occupational stress on work-related musculoskeletal disorders (WMSDs) in electronics manufacturing workers. Methods A total of 392 front-line workers in two electronic manufacturing enterprises in Guangdong Province were selected as the research subjects using the judgment sampling method. The prevalence of WMSDs and the level of occupational stress of the research subjects were investigated using the Musculoskeletal Disorders Questionnaire and the Core Occupational Stress Scale. Results The total WMSDs detection rate was 39.5%, and the multi-site WMSDs detection rate was 30.6%. The detection rate of occupational stress was 14.8%. The total WMSDs detection rate and multi-site WMSDs detection rate in the occupational stress group were higher than those in the non-occupational stress group (65.5% vs 35.0%, 56.9% vs 26.0%, both P<0.01). Binary logistic regression analysis result showed that the risk of WMSDs in the occupational stress group was higher than that in the non-occupational stress group after adjusting the effect of confounding factors such as age, gender, job type and work days per week (P<0.01). Conclusion The occupational stress may increase the risk of WMSDs in electronics manufacturing workers. Reducing the level of occupational stress among workers in electronic manufacturing enterprises is beneficial for reducing the risk of WMSDs.
9.Diagnostic and intervention value of implantable cardiac monitor in patients over 60 years of age with unexplained syncope
Rui WANG ; Yanfei ZHANG ; Hongchao ZHANG ; Jia WANG ; Shuhui SHEN ; Jiabin TONG ; Junpeng LIU ; You LYU ; Jia CHONG ; Zhilei WANG ; Xin JIN ; Lin SUN ; Xu GAO ; Yan DAI ; Jing LIANG ; Haitao LI ; Tong ZOU ; Jiefu YANG
Chinese Journal of Cardiology 2024;52(7):784-790
Objective:To investigate the value of implantable cardiac monitor (ICM) in the diagnosis and treatment of patients over 60 years old with unexplained syncope.Methods:This was a multi-center, prospective cohort study. Between June 2018 and April 2021, patients over the age of 60 with unexplained syncope at Beijing Hospital, Fuwai Hospital, Beijing Anzhen Hospital and Puren Hospital were enrolled. Patients were divided into 2 groups based on their decision to receive ICM implantation (implantation group and conventional follow-up group). The endpoint was the recurrence of syncope and cardiogenic syncope as determined by positive cardiac arrhythmia events recorded at the ICM or diagnosed during routine follow-up. Kaplan‐Meier survival analysis was used to compare the differences of cumulative diagnostic rate between the 2 groups. A multivariate Cox regression analysis was performed to determine independent predictors of diagnosis of cardiogenic syncope in patients with unexplained syncope.Results:A total of 198 patients with unexplained syncope, aged (72.9±8.25) years, were followed for 558.0 (296.0,877.0) d, including 98 males (49.5%). There were 100 (50.5%) patients in the implantation group and 98 (49.5%) in the conventional follow-up group. Compared with conventional follow-up group, patients in the implantation group were older, more likely to have comorbidities, had a higher proportion of first degree atrioventricular block indicated by baseline electrocardiogram, and had a lower body mass index (all P<0.05). During the follow-up period, positive cardiac arrhythmia events were recorded in 58 (58.0%) patients in the ICM group. The diagnosis rate (42.0% (42/100) vs. 4.1% (4/98), P<0.001) and the intervention rate (37.0% (37/100) vs. 2.0% (2/98), P<0.001) of cardiogenic syncope in the implantation group were higher than those in the conventional follow-up group (all P<0.001). Kaplan-Meier survival analysis showed that the cumulative diagnostic rate of cardiogenic syncope was significantly higher in the implantation group than in the traditional follow-up group ( HR=11.66, 95% CI 6.49-20.98, log-rank P<0.001). Multivariate analysis indicated that ICM implantation, previous atrial fibrillation, diabetes mellitus or first degree atrioventricular block in baseline electrocardiogram were independent predictors for cardiogenic syncope (all P<0.05). Conclusions:ICM implantation improves the diagnosis and intervention rates in patients with unexplained syncope, and increases diagnostic efficiency in patients with unexplained syncope.
10.Analysis of viral infections in adult acute respiratory infection cases in Shanghai, 2023
Huanru WANG ; Jiabin MOU ; Qi QIU ; Jiajing LIU ; Fang YUAN ; Meihua LIU ; Xiaode TANG ; Jingyi ZHANG ; Jian CHEN ; Min CHEN ; Huanyu WU ; Zheng TENG
Chinese Journal of Experimental and Clinical Virology 2024;38(4):439-445
Objective:To elucidate the etiological and epidemiological characteristics and epidemiological patterns of viral acute respiratory infections (ARI) in Shanghai during 2023, with the aim of providing robust laboratory evidence for effective prevention and control strategies against related respiratory diseases and facilitating risk assessment.Methods:Respiratory pathogens were detected in the clinical surveillance specimens submitted by sentinel hospitals through multiplex PCR, as part of the multi-pathogen surveillance of acute respiratory infections in Shanghai during 2023. The obtained detection result were statistically analyzed in conjunction with sample information.Results:The positive detection rate of viral pathogens in 2023 was 21.17% (984/4 648), with rates of 33.53% (504/1 503) observed in ILI cases and 15.62% (480/3 145) in SARI cases. Influenza A virus (FluA) was the predominant virus detected, accounting for 13.7% (637/4 648). Other viruses identified in the surveillance samples included influenza B virus (Flu B), human rhinovirus/enterovirus (HRV/HEV), respiratory syncytial virus (RSV), human metapneumovirus (HMPV), parainfluenza virus (PIV), adenovirus (ADV) and human bocavirus (HBoV). Regarding temporal distribution, HRV/HEV and RSV exhibited the highest detection rates during the second quarter at 2.27% each (28/1 236). PIV had its peak during the third quarter at a rate of 2.49% (35/1 405), and HMPV showed prevalence mainly during the third and fourth quarters, with detection rates of 2.63% (37/1 405) and 2.35% (32/1 360), respectively.Conclusions:In acute respiratory infection surveillance cases in Shanghai in 2023, Flu A emerged as the predominant respiratory pathogen. The detection rate of HMPV ranked second only to Flu A, while other respiratory viruses such as HRV/HEV, RSV, and PIV were detected during different seasons and co-circulated. The prevalence of various respiratory viruses varied among different infected populations and over times.

Result Analysis
Print
Save
E-mail