1.Analysis on positioning error of different body position fixation methods guided by cone beam CT images in breast cancer radiotherapy
Huizhan JIA ; Xiao LI ; Lin LEI ; Mingying GENG ; Peng ZHOU
Chongqing Medicine 2024;53(11):1626-1629
Objective To investigate the difference of translational error and rotational error in the ra-diotherapeutic positioning after breast cancer modified radical surgery by using the two fixation methods of the cervicothoracic thermoplastic membrane and body thermoplastic membrane based on conical beam CT (CBCT) images.Methods A total of 82 patients with radiotherapy after breast cancer modified radical sur-gery admitted and treated in this hospital from January 2022 to September 2023 were selected as the study subjects and divided into the cervicothoracic membrane group (using the cervicothoracic thermoplastic mem-brane,n=52) and body membrane group (using the body thermoplastic membrane,n=30) according to the radiotherapeutic fixation methods.All patients weekly conducted the CGCT scanning in the first time radio-therapy and radiotherapeutic period.The verification image conducted the retification with the planned image. The translational errors in the left and right direction (X),head and foot direction (Y) and abdominal and dor-sal direction (Z) were recorded,as well as the rotation errors around the axis under the two fixing methods,including the rotation error of the X-axis rotation direction (Rx),Y-axis rotation direction (Ry),and Z-axis rotation direction (Rz).The differences in positioning errors were compared between the two groups. Results There was no significant difference in X,Y,Z,Rx,Ry and Rx positioning error between the two groups after the first treatment,1-week treatment and 2-week treatment (P>0.05).After 3-week treatment,the positioning errors in X[0.21(0.12,0.27)mm vs. 0.22(0.20,0.35)mm],Y[0.20(0.11,0.24)mm vs. 0.25(0.16,0.37)mm],Z[0.15(0.08,0.25)mm vs. 0.20(0.15,0.29)mm],Rx[0.57(0.22,1.10)° vs. 1.00 (0.70,1.50)°],Ry[0.50(0.30,1.20)° vs. 1.10(0.60,1.40)°]and Rz[0.30(0.20,0.80)° vs. 0.90(0.40,1.50)°]in the cervicothoracic membrane group were smaller compared with the body membrane group (P<0.05).After 4-week treatment,the positioning errors in X[0.19(0.12,0.27)mm vs. 0.25(0.21,0.31)mm],Y[0.21(0.11,0.27)mm vs. 0.26(0.22,0.32)mm],Z[0.12(0.05,0.28)mm vs. 0.22(0.13,0.35)mm],Rx[0.80(0.49,1.10)°vs. 1.20(0.80,1.80)°],Ry[0.55(0.20,1.12)°vs. 1.10(0.80,1.30)°]and Rz[0.61 (0.29,1.10)°vs. 1.10(0.80,1.40)°]in the cervicothoracic membrane group were also smaller compared with the body membrane group (P<0.05).Conclusion The thecervicothoracic thermoplastic membrane could re-duce the positioning error in the breast cancer radiotherapy compared with the body thermoplastic membrane.
2.Correlations between the average Young's modulus and histopathological characteristics of papillary thyroid carcinoma
Lili SU ; Xiaoyan KANG ; Xueting LI ; Yaqin LI ; Jiping XUE ; Huizhan LI ; Yanxia ZHANG
Chinese Journal of Oncology 2024;46(2):127-132
Objective:To explore the histopathological factors affecting the stiffness of papillary thyroid carcinoma (PTC).Methods:Ninety-six patients with PTC confirmed by surgery and pathology in Shanxi Bethune Hospital from January 2019 to December 2020 were selected, including 101 nodules. Two-dimensional ultrasound and shear-wave elastography (SWE) were performed before surgery and the average Young's modulus (Emean) of PTC nodules were measured. Histopathological examinations on the nodules were conducted after surgery to decide the lesion size, number of lesions, calcification type, presence or absence of capsular and extracapsular invasion, degree of fibrosis, microvessel density, and number of tumor cells. The correlations between the lesion size, degree of fibrosis, microvessel density, and number of tumor cells and the Emean were analyzed. The Emeans of nodules with different numbers of lesions, presence or absence of capsular and extracapsular invasion, and different pathological calcification types were compared. The multiple linear regression analysis was used to evaluate the histopathological factors influencing the Emean.Results:The ranges of the lesion sizes, degrees of fibrosis, microvascular density, numbers of tumor cells, and the Emeans of the 101 investigated PTC nodules were (1.29±0.95) cm, (30.64±18.37)%, (101.64±30.7) vessels per high power field, (373.52±149.87) cells per high power field, and (36.47±19.62) kPa, respectively. Correlation analysis showed that the lesion size of PTC and the degree of fibrosis were positively correlated with the Emean ( r=0.660, P<0.001; r=0.789, P<0.001), while the microvessel density was negatively correlated with the Emean ( r=-0.198, P=0.047). The Emean of the group with capsular and extracapsular invasion was higher than that of the group without ( P=0.014). There were statistical differences in the Emeans among different types of pathological calcification ( P<0.001). The multiple linear regression analysis showed that the lesion size ( β=0.325, P<0.001), degree of fibrosis ( β=0.563, P<0.001), psammoma bodies ( β=0.177, P=0.001), stromal calcification ( β=0.164, P=0.003), and mixed calcification of both psammoma bodies and stroma ( β=0.163, P=0.003) were independent influencing factors for the Emean. The degree of fibrosis had the greatest impact on the Emean. Conclusions:The Emean of PTC lesions was correlated with the histopathological characteristics of PTC. The lesion size, degree of fibrosis, and calcification had significant impact on the Emean, among which the degree of fibrosis had the greatest impact.
3.Correlations between the average Young's modulus and histopathological characteristics of papillary thyroid carcinoma
Lili SU ; Xiaoyan KANG ; Xueting LI ; Yaqin LI ; Jiping XUE ; Huizhan LI ; Yanxia ZHANG
Chinese Journal of Oncology 2024;46(2):127-132
Objective:To explore the histopathological factors affecting the stiffness of papillary thyroid carcinoma (PTC).Methods:Ninety-six patients with PTC confirmed by surgery and pathology in Shanxi Bethune Hospital from January 2019 to December 2020 were selected, including 101 nodules. Two-dimensional ultrasound and shear-wave elastography (SWE) were performed before surgery and the average Young's modulus (Emean) of PTC nodules were measured. Histopathological examinations on the nodules were conducted after surgery to decide the lesion size, number of lesions, calcification type, presence or absence of capsular and extracapsular invasion, degree of fibrosis, microvessel density, and number of tumor cells. The correlations between the lesion size, degree of fibrosis, microvessel density, and number of tumor cells and the Emean were analyzed. The Emeans of nodules with different numbers of lesions, presence or absence of capsular and extracapsular invasion, and different pathological calcification types were compared. The multiple linear regression analysis was used to evaluate the histopathological factors influencing the Emean.Results:The ranges of the lesion sizes, degrees of fibrosis, microvascular density, numbers of tumor cells, and the Emeans of the 101 investigated PTC nodules were (1.29±0.95) cm, (30.64±18.37)%, (101.64±30.7) vessels per high power field, (373.52±149.87) cells per high power field, and (36.47±19.62) kPa, respectively. Correlation analysis showed that the lesion size of PTC and the degree of fibrosis were positively correlated with the Emean ( r=0.660, P<0.001; r=0.789, P<0.001), while the microvessel density was negatively correlated with the Emean ( r=-0.198, P=0.047). The Emean of the group with capsular and extracapsular invasion was higher than that of the group without ( P=0.014). There were statistical differences in the Emeans among different types of pathological calcification ( P<0.001). The multiple linear regression analysis showed that the lesion size ( β=0.325, P<0.001), degree of fibrosis ( β=0.563, P<0.001), psammoma bodies ( β=0.177, P=0.001), stromal calcification ( β=0.164, P=0.003), and mixed calcification of both psammoma bodies and stroma ( β=0.163, P=0.003) were independent influencing factors for the Emean. The degree of fibrosis had the greatest impact on the Emean. Conclusions:The Emean of PTC lesions was correlated with the histopathological characteristics of PTC. The lesion size, degree of fibrosis, and calcification had significant impact on the Emean, among which the degree of fibrosis had the greatest impact.
4. Value of shear wave elastrography image classification in the diagnosis of breast masses
Tingting LI ; Chunsong KANG ; Huizhan LI ; Jiping XUE ; Qingmei YANG ; Hong LYU
Chinese Journal of Oncology 2019;41(7):540-545
Objective:
To analyze the image features of shear wave elastrography (SWE) in breast masses, and to evaluate their values in the differentiation of benign and malignant breast lesions.
Methods:
A total of 361 patients with 403 breast lesions who simultaneously underwent conventional ultrasound and SWE examination from February 2015 to January 2018 were selected. Diagnosis in all patients was confirmed by aspiration biopsy or operative pathology. The SWE images were collected and the elastic images were divided into 5 types. The SWE image features of different breast pathological types were summarized, and their values in benign and malignant breast lesion diagnoses were evaluated.
Results:
The main features of benign breast lesion were type Ⅰ and Ⅱ, the main features of the malignant lesion were type Ⅳ and Ⅴ, and the proportion of which were 43.6% (71/163), 37.4% (61/163), 22.1% (53/240) and 57.9% (139/240), respectively. Type Ⅲ accounted for a certain proportion in both benign and malignant lesions. The SWE image features of benign and malignant lesions were compared and a significant difference was observed (
5.Value of shear wave elastrography image classification in the diagnosis of breast masses
Tingting LI ; Chunsong KANG ; Huizhan LI ; Jiping XUE ; Qingmei YANG ; Hong LYU
Chinese Journal of Oncology 2019;41(7):540-545
To analyze the image features of shear wave elastrography (SWE) in breast masses, and to evaluate their values in the differentiation of benign and malignant breast lesions.Methods A total of 361 patients with 403 breast lesions who simultaneously underwent conventional ultrasound and SWE examination from February 2015 to January 2018 were selected. Diagnosis in all patients was confirmed by aspiration biopsy or operative pathology. The SWE images were collected and the elastic images were divided into 5 types. The SWE image features of different breast pathological types were summarized, and their values in benign and malignant breast lesion diagnoses were evaluated. Results The main features of benign breast lesion were type Ⅰ and Ⅱ, the main features of the malignant lesion were type Ⅳ and Ⅴ, and the proportion of which were 43.6%(71/163), 37.4%(61/163), 22.1%(53/240) and 57.9%(139/240), respectively. Type Ⅲ accounted for a certain proportion in both benign and malignant lesions. The SWE image features of benign and malignant lesions were compared and a significant difference was observed (P<0.001). The typeⅤfeatures were mainly observed in invasive ductal carcinoma, invasive lobular carcinoma and other types of invasive carcinoma, while the typeⅣ features were mostly presented in ductal carcinoma in situ and mucinous carcinoma. Fibroadenoma, fibroadenosis accompanied with fibroadenoma, and fibroadenosis were featured with typeⅠ. Both intraductal papilloma and benign phyllodes tumor were mostly type Ⅱ, while typeⅢandⅤwere more common in chronic granulomatous mastitis. When typeⅠand typeⅡof breast lesions were classified as benign features while type Ⅳ and Ⅴ were malignant features, the sensitivity and specificity of breast malignant lesion diagnosis were 91.2% and 84.7% by application of SWE combined with breast imaging reporting and data system ( BI?RADS). The sensitivity of combined diagnosis was slightly lower than that of conventional ultrasound (P>0.05), but the specificity was significantly higher than conventional ultrasound ( P<0.01 ). Conclusion The SWE is a simple and effective method. Combination of SWE with conventional ultrasound may improve the diagnostic differentiation of benign and malignant breast lesions.
6.Value of shear wave elastrography image classification in the diagnosis of breast masses
Tingting LI ; Chunsong KANG ; Huizhan LI ; Jiping XUE ; Qingmei YANG ; Hong LYU
Chinese Journal of Oncology 2019;41(7):540-545
To analyze the image features of shear wave elastrography (SWE) in breast masses, and to evaluate their values in the differentiation of benign and malignant breast lesions.Methods A total of 361 patients with 403 breast lesions who simultaneously underwent conventional ultrasound and SWE examination from February 2015 to January 2018 were selected. Diagnosis in all patients was confirmed by aspiration biopsy or operative pathology. The SWE images were collected and the elastic images were divided into 5 types. The SWE image features of different breast pathological types were summarized, and their values in benign and malignant breast lesion diagnoses were evaluated. Results The main features of benign breast lesion were type Ⅰ and Ⅱ, the main features of the malignant lesion were type Ⅳ and Ⅴ, and the proportion of which were 43.6%(71/163), 37.4%(61/163), 22.1%(53/240) and 57.9%(139/240), respectively. Type Ⅲ accounted for a certain proportion in both benign and malignant lesions. The SWE image features of benign and malignant lesions were compared and a significant difference was observed (P<0.001). The typeⅤfeatures were mainly observed in invasive ductal carcinoma, invasive lobular carcinoma and other types of invasive carcinoma, while the typeⅣ features were mostly presented in ductal carcinoma in situ and mucinous carcinoma. Fibroadenoma, fibroadenosis accompanied with fibroadenoma, and fibroadenosis were featured with typeⅠ. Both intraductal papilloma and benign phyllodes tumor were mostly type Ⅱ, while typeⅢandⅤwere more common in chronic granulomatous mastitis. When typeⅠand typeⅡof breast lesions were classified as benign features while type Ⅳ and Ⅴ were malignant features, the sensitivity and specificity of breast malignant lesion diagnosis were 91.2% and 84.7% by application of SWE combined with breast imaging reporting and data system ( BI?RADS). The sensitivity of combined diagnosis was slightly lower than that of conventional ultrasound (P>0.05), but the specificity was significantly higher than conventional ultrasound ( P<0.01 ). Conclusion The SWE is a simple and effective method. Combination of SWE with conventional ultrasound may improve the diagnostic differentiation of benign and malignant breast lesions.
7. Quantitative assessment of renal tissue elasticity in patients with liver cirrhosis by shear wave elastography
Huizhan LI ; Tinghua FENG ; Jiping XUE ; Shuai LI ; Ruiqing LI ; Chunsong KANG
Chinese Journal of Ultrasonography 2018;27(7):609-613
Objective:
To investigate the value of shear wave elastography (SWE) in the early diagnosis of hepatic cirrhosis nephropathy.
Methods:
Seventy-three hepatic cirrhosis patients with normal conventional renal function were enrolled in the study, and were subdivided into Child-Pugh A group, Child-Pugh B group and Child-Pugh C group. Forty healthy volunteers were served as the control group. All the subjects underwent SWE to obtain the Young′s modulus value of left renal cortex, medulla and parenchyma which included Emax, Emin, Emean. The Young′s modulus value were compared among different groups.
Results:
Compared to the control group, the Emax, Emean of left renal cortex, modulus and parenchyma in hepatic cirrhosis group were higher(
8.Preliminary application research of Ultrafast Doppler for renal artery ultrasonography
Wenli XIAO ; Xiaoyan KANG ; Huizhan LI ; Chunsong KANG ; Xiaoyan CHEN
Chinese Journal of Ultrasonography 2016;25(4):324-328
Objective To analyze the accuracy,repeatability and feasibility of Ultrafast Doppler for renal artery ultrasonography.Methods One hundred and one cases were selected that were suspected to have renal artery disease and were successful of conventional and Ultrafast Doppler for renal artery ultrasonography,and 101 cases were grouped by age (≤40 years old,41-60 years old,≥61 years old),body mass index (BMI) (normal 18.5-23.9 kg/m2,overweight 24.0-27.9 kg/m2,obesity ≥28.0kg/m2) and whether there were the presence of renal artery stenosis (no significant renal artery stenosis and renal artery stenosis >60%).Each case was respectively examined by conventional and Ultrafast Doppler for renal artery ultrasonography in a random order.The consistency of Doppler parameters was tested.The duration of each Doppler study was compared and the feasibility of Ultrafast Doppler for renal artery ultrasonography was explored.The Doppler parameters included:renal artery peak systolic velocity (PSV),resistance index (RI),renal segmental artery acceleration time (T) and time consuming (△T).The concordence and △T of two Doppler method were compared.Results ① Ultrafast Doppler had good reproducibility,intraclass correlation coefficient (ICC) values were > 0.6.② For renal artery ultrasonography,the successful number of cases examined by Ultrafast Doppler were more than those examined by conventional Doppler,but the difference was not statistically significant (P >0.05).③The Doppler parameters from all subjects and different groups showed a strong positive correlation between the two Doppler studies (P <0.05).④ UltraFast Doppler required a shorter time than conventional Doppler (P <0.05).⑤The △T of cases with different ages and with or without renal artery stenosis showed no statistically significant (P >0.05),however,their △T were increased with body mass index increasing (P<0.05).Conclusions Ultrafast Doppler for renal artery ultrasonography has a high success rate,a good repeatability and consistency,and a shorter time consuming and simple operation than conventional Doppler.
9.In vivo study of the temperature changes of brain tissue surrounding microwave ablation zone in ;a canine model
Linggang, CHENG ; Wen, HE ; Lishu, WANG ; Huizhan, LI ; Wenyan, HUANG
Chinese Journal of Medical Ultrasound (Electronic Edition) 2014;(3):59-62
Objective To investigate the alteration of peripheral tissue`s temperature of the coagulation zone of microwave ablation in brain tissue, and to provide experimental evidence for clinical application. Methods Twelve canines were treated by microwave ablation in brain tissue. Each was ablated for 180 s with microwave output power of 20 W, 30 W, and 40 W. During the operation the peripheral temperature at the distance of 0.5 cm, 1.0 cm, 1.5 cm and 2.0 cm from the ablation center was recorded respectively. The ultrasound was performed 1 hour after the operation, and then the animals were executed and the microscopic changes of the ablation lesion were observed. Results Eleven canines suffered well for the ablation, while 1 presented abnormal respiration during the operation and died 2 hours later. During the operation, the temperature of the area 0.5 cm from the center rose signiifcantly, with the maximum temperature was (96.40±1.46)℃at the power of 20 W, and 100℃at the power of 30 W and 40 W. The temperature of the area 1.0 cm from the center rose faster, with the maximum temperatures at different powers all above the 46℃. The temperature of the area 1.5 cm from the center rose slower, with the maximum temperature below 46℃at the power of 20 W and 30 W and above 46℃at the power of 40 W. The maximum temperatures of the area 2.0 cm from the center at different powers were all below 46℃. The difference of the maximum temperature at different distances (1.0 cm, 1.5 cm, and 2.0 cm from the center) was signiifcant (F=776.78, 2640.64 and 3025.53, all P<0.05). The length and width of the ablation lesion as well as the area of edema increased with the power. At the power of 20 W, 30 W, and 40 W, the length of the ablation lesion was (29.3±1.8) mm, (32.7±2.1) mm and (34.2±2.4) mm, the width was (22.5±1.5) mm, (23.7±1.7) mm and (27.1±2.0) mm, and the width of the edema zone was (2.3±0.4) mm, (2.6±0.4) mm and (2.7±0.5) mm. The differences of the length and width of the ablation lesion at different powers were signiifcant (F=11.46, 14.49, both P<0.01). The difference of the edema area at different powers was insigniifcant (F=1.94, P=0.169). Conclusions Microwave ablation is a safe therapeutic modality. However, the shorter distance from the ablation center and greater ablation power give rise to larger ablation lesion, higher maximum temperature, and faster temperature increase. Therefore, 2.0 cm from the ablation center is a safe area.
10.The value of color Doppler ultrasound in diagnosing in-stent restenosis in lower limb artery
Shijing, SONG ; Huizhan, LI ; Qingmei, YANG ; Xiaoyan, KANG ; Fucheng, YAO ; Jiping, XUE ; Hong, LYU ; Chunsong, KANG
Chinese Journal of Medical Ultrasound (Electronic Edition) 2014;(9):710-714
Objective To investigate the value of color Doppler flow imaging(CDFI) in diagnosing lower limb artery in-stent restenosis (ISR), and to provide the evidences for clinical application. Methods Patients with lower limb artery percutaneous transluminal stent insertion in 12 months were enrolled in this study and divided into two groups, CT angiography (CTA) or digital subtraction angiography (DSA) was applied to diagnose ISR, 31 patients with 47 stenting which were diagnosed ISR was named as restenosis group, 63 patients with 89 stenting which were diagnosed no ISR was named as no stenosis group, and 30 normal person was enrolled and named as normal control group. Ultrasonic characteristics and peak systolic blood flow velocity (PSV), systolic blood flow acceleration time (AT) of proximal part, inner stents, distal part were recorded in restenosis group and no stenosis group, then compared with data in normal control group. Regression and receiver operator (ROC) curve were applied to analyse the correlation between PSV and AT. Results PSV of no stenosis group in common femoral artery, femoral artery, superifcial, popliteal artery stent respectively were (146.71±35.59) cm/s, (120.11±25.67) cm/s, (96.44±32.87) cm/s. PSV of normal control group in common femoral artery, femoral artery, superifcial, popliteal artery respective were (119.67±15.34) cm/s, (91.17±15.09) cm/s, (71.13±21.23) cm/s. There was statistically signiifcant difference between the two groups (t=2.457, 2.459, 2.321, all P<0.05). AT of no stenosis group in common femoral artery, femoral artery, superficial, popliteal artery stent respectively were (84.98±13.77) ms, (87.33±16.36) ms, (90.77±12.05) ms. AT of normal control group in common femoral artery, femoral artery, superficial, popliteal artery respective were (78.23±21.24) ms, (82.31±18.24) ms, (84.29±23.01) ms. There was no statistically signiifcant difference between the two groups (t=1.696, 1.904, 1.835, all P>0.05). PSV of restenosis group in proximal part, restenosis part, distal part respectively were (87.67±23.34) cm/s, (218.17±72.09) cm/s, (54.13±21.23) cm/s. PSV of no stenosis group in proximal part, inner stents, distal part respectively were (91.71±25.59) cm/s, (131.11±45.67) cm/s, (96.44±32.87) cm/s. There was statistically significant difference between restenosis part/inner stents, distal part (t=3.412, 3.511, both P<0.05). There was no statistically signiifcant difference between the two groups in proximal part (t=1.901, P>0.05). AT of restenosis group in proximal part, restenosis part, distal part respectively were (98.31±14.09) ms, (109.54±21.03) ms, (158.23±45.21) ms. AT of no stenosis group in proximal part, inner stents, distal part respectively were (84.98±13.77) ms, (86.34±19.36) ms, (83.77±17.05) ms. There was statistically signiifcant difference between restenosis part/inner stents, distal part (t=2.319, 3.610, both P<0.05). There was no statistically signiifcant difference between the two groups in proximal part (t=1.833, P>0.05). ROC curve showed that in ISR lower limb artery, PSV>168 cm/s had a sensitivity of 89.4%, speciifcity of 92.1%, the area under the ROC curve was 0.949;AT>127 ms, had a sensitivity of 86.8%, speciifcity of 98.0%, the area under the ROC curve was 0.867. Conclusions CDFI can detect the changes of PSV and AT, ISR can be detected and diagnosed earlier in lower limb artery. By combining PSV>168 cm/s with AT>127 ms, the value of ISR diagnosis can be increased.

Result Analysis
Print
Save
E-mail