1.Effect of Tongdu Huoxue Decoction on Lumbar Spine Function and Serum Inflammatory Factor Levels in Patients with Acute Lumbar Disc Herniation
Yumo XIONG ; Zichen LI ; Ying LI ; Qiangbing XIAO ; Lihua WANG ; Hao HU ; Ruibing FENG ; Jie QIAO ; Yan HU
Chinese Journal of Experimental Traditional Medical Formulae 2024;30(13):135-141
ObjectiveTo observe the clinical efficacy of Tongdu Huoxue decoction in the treatment of acute lumbar disc herniation (LDH). MethodA total of 316 patients with acute LDH admitted to the orthopedic outpatient department of Hubei Provincial Hospital of Traditional Chinese Medicine and Honghu City Hospital of Traditional Chinese Medicine from January 2020 to June 2023 were randomly divided into two groups. 156 cases in the control group (two cases with stopped follow-up) were treated with meloxicam tablets, while 153 cases in the observation group (five cases with stopped follow-up) were treated with Tongdu Huoxue decoction. Both groups were treated for three months. The clinical efficacy, McGill Pain Score Scale (SF-MPQ), Oswestry Dysfunction Index (ODI) score, and the Japanese Orthopaedic Association (JOA) scores of the two groups before and after treatment were compared. The serum levels of interleukin-1β (IL-1β), interleukin-6 (IL-6), and tumor necrosis factor-α (TNF-α) of the patients before and after treatment were determined by using enzyme-linked immunosorbent assay (ELISA). The NDI-092 type electromyography-evoked potential instrument was adopted to measure the motor conduction velocity and clinical efficacy of the tibial and common peroneal nerves in patients of the two groups before and after treatment, and the clinical safety of the two groups of patients was compared. ResultAfter treatment, the total effective rate in the observation group was 95.4% (146/153), significantly higher than that in the control group of 76.3% (119/156) (χ2 =23.18, P<0.05). After treatment, both groups showed significant reductions in SF-MPQ and ODI scores, as well as the levels of IL-1β, IL-6, and TNF-α (P<0.05), with the observation group showing a more significant reduction (P<0.05). Both groups showed a significant increase in JOA scores and motor conduction velocities of the tibial and common peroneal nerves after treatment (P<0.05), with the observation group showing a more significant increase (P<0.05). ConclusionTongdu Huoxue decoction can alleviate lumbar and leg pain in acute LDH, improve lumbar spine function, and suppress inflammatory reactions. It is highly safe and is worthy of clinical promotion.
2.Conventional ultrasound combined with contrast-enhanced ultrasound for analyzing impact factors of pathological grade of nonfunctional pancreatic neuroendocrine tumor
Tingting HUO ; Huifang JIN ; Honghu WANG ; Shuai WANG
Chinese Journal of Interventional Imaging and Therapy 2024;21(11):670-674
Objective To explore the impact factors of pathological grade of nonfunctional pancreatic neuroendocrine tumor(PNET)based on conventional ultrasound and contrast-enhanced ultrasound(CEUS).Methods Totally 86 patients with single lesion of nonfunctional PNET were retrospectively enrolled and divided into G1 grade group(n=48),G2 grade group(n=25)and G3 grade group(n=13)based on pathological results.Clinical and ultrasonic data were compared among groups,and logistic regression analysis was used to screen impact factors of pathological grade of nonfunctional PNET.Results Significant differences of the morphology,boundary,surrounding organs/blood vessels invasion or not,degree of arterial phase enhancement,venous phase enhancement and total enhancement pattern of lesions were found among 3 groups(all P<0.05).The morphology,boundary,degree of arterial phase enhancement and degree of venous phase enhancement of lesions were all independent impact factors of pathological grade of nonfunctional PNET(all P<0.05).Conclusion Morphology,boundary,degree of arterial phase enhancement and venous phase enhancement of lesions were all impact factors of pathological grade of nonfunctional PNET.
3.A clinical randomized controlled trail of an intelligent robot-assisted minimally invasive reduction system for treatment of unstable pelvic fractures
Honghu XIAO ; Chunpeng ZHAO ; Qiyong CAO ; Lijia ZHANG ; Yufeng GE ; Gang ZHU ; Yu WANG ; Xinbao WU
Chinese Journal of Orthopaedic Trauma 2023;25(4):341-350
Objective:To compare the short-term efficacy between our self-designed intelligent robot-assisted minimally invasive reduction system and conventional freehand reduction assisted by fluoroscopy in the treatment of unstable pelvic fractures by robot or fluoroscopy-assisted internal fixation with percutaneous screws.Methods:A prospective randomized controlled trial was conducted to include eligible 35 patients with unstable pelvic fracture who were admitted to Department of Orthopaedic Trauma, Beijing Jishuitan Hospital from December 2021 to October 2022. They were randomized into 2 groups. The observation group[17 cases, 10 males and 7 females with an age of (44.0±17.4) years] was treated with robot-assisted minimally invasive reduction, followed by robot-assisted or fluoroscopic internal fixation with percutaneous screws; the control group[18 cases, 12 males and 6 females with an age of (38.8±15.0) years] was treated with freehand reduction assisted by fluoroscopy, followed by robot-assisted or fluoroscopic internal fixation with percutaneous screws. The 2 groups were compared in terms of operation time, intraoperative bleeding, successful reduction, reduction quality, incidence of surgical complications and postoperative functional scores.Results:The 2 groups were comparable because there were no significant differences in the preoperative general data between them ( P>0.05). The intraoperative fluoroscopy frequency[(32.4±17.5) times] and fluoroscopy time [(19.8±10.4) s] in the observation group were significantly lower or shorter than those in the control group [(60.8±26.6) times and (38.2±16.1) s], and the rate of successful reduction in the observation group was 100.0% (17/17), significantly higher than that in the control group[72.2% (13/18)] ( P<0.05). There was no significant difference between the 2 groups in intraoperative bleeding, operation time, reduction error, excellent and good rate of reduction after operation by Matta scoring, or Majeed functional score at 12 weeks after operation ( P>0.05). Conclusion:In the treatment of unstable pelvic fractures, since our self-designed intelligent robot-assisted minimally invasive reduction system can plan autonomously the reduction paths and accomplish minimally invasive reduction of the fracture with 3D images real-time monitoring, it is advantageous over conventional reduction methods in a higher success rate and less radiation exposure.
4.Study of left ventricular myocardial mechanics in patients with different risk stratifications of hypertrophic cardiomyopathy by four-dimensional automatic left ventricular quantitation technology
Silu DAI ; Lina WU ; Weitao GUO ; Honghu WANG ; Wenqiang SHI ; Huican DUAN ; Lingyun WANG ; Xi ZHAO ; Ruifang ZHANG
Chinese Journal of Ultrasonography 2023;32(4):295-302
Objective:To explore the application value of four-dimensional automatic left ventricular quantitation(4D Auto LVQ) technology, in evaluating the myocardial mechanics in patients with different risk stratifications of hypertrophic cardiomyopathy(HCM).Methods:A total of 88 HCM patients and 20 healthy volunteers were selected from February 2020 to February 2022 in the First Affiliated Hospital of Zhengzhou University. According to the HCM Risk-SCD score, HCM patients were divided into 3 groups: low-risk group( n=49), intermediate-risk group( n=21), and high-risk group( n=18). Conventional ultrasound parameters were collected, and 4D Auto LVQ technology was used to obtain the mechanical parameters of left ventricular myocardium, including global longitudinal strain(GLS) , global circumferential strain(GCS), global area strain(GAS), global radial strain(GRS), twist and torsion. The differences in these parameters among the four groups were compared. The predictive values of conventional ultrasound parameters and myocardial mechanical parameters in patients with intermediate- and high-risk HCM patients were analyzed by ROC curve. Results:①Left ventricular end-diastolic diameter, left ventricular end-diastolic volume, left ventricular end-systolic volume, and peak systolic velocity of mitral annulus in the low-, intermediate-, and high-risk groups were lower than those in the control group while left ventricular maximal wall thickness(LVMWT) and early diastolic peak velocity of mitral value orifice/early diastolic peak velocity of mitral annulus(E/e′) were higher, left atrial diameter(LAD) and left ventricular outflow tract gradients(LVOTG) in the intermediate- and high-risk groups were higher than the low-risk group(all P<0.05). ②Compared with the control group, the GLS of HCM patients was lower, and the GLS of the intermediate- and high-risk groups was lower than the low-risk group. GCS and GRS in the intermediate- and high-risk groups were lower than those in the low-risk group. GAS in the high-risk group was lower than the low-risk and the control group, but higher than the intermediate-risk group(all P<0.05). Compared with the control group, the twist and torsion in the intermediate- and high-risk groups were higher, but lower than the low-risk group, and the differences were statistically significant(all P<0.05). ③The ROC results showed that the area under the curve(AUC) of the model containing conventional ultrasound parameters(LVWMT, LAD, and LVOTG) for predicting intermediate- and high-risk HCM patients was 0.811, with a sensitivity of 0.769 and a specificity of 0.755. The AUC of the conventional ultrasound parameters combined with myocardial mechanical parameters was 0.904, as the sensitivity was 0.667 and the specificity was 0.980. Conclusions:4D Auto LVQ can evaluate the mechanical characteristics of LV myocardium in HCM patients with different risk stratifications. Myocardial mechanical parameters combined with conventional ultrasound parameters can improve the diagnostic performance of patients with intermediate- and high-risk HCM.
5.Intelligent robot-assisted minimally invasive reduction system for reduction of unstable pelvic fractures: a cadaveric study
Chunpeng ZHAO ; Yu WANG ; Xu SUN ; Gang ZHU ; Honghu XIAO ; Lijia ZHANG ; Xiangrui ZHAO ; Shuchang SHI ; Xinbao WU
Chinese Journal of Orthopaedic Trauma 2022;24(5):372-379
Objective:To evaluate a self-designed intelligent robot-assisted minimally invasive reduction system in the reduction of unstable pelvic fractures by a cadaveric anatomic study.Methods:Ten unembalmed cadavers (7 male and 3 female ones) were used in this study. In each cadaveric specimen an unstable pelvic fracture was created in accordance with clinical case models (3 cases of type B1, 4 cases of type B2 and 3 cases of type C1 by the Tile classification). A self-designed intelligent robot-assisted minimally invasive reduction system was used to assist the reduction in the cadaveric models. Intraoperative registration and navigation time, autonomous reduction time, total operation time and reduction error were measured.Results:Effective reduction was completed in 10 bone models with the assistance of our self-designed intelligent robot-assisted minimally invasive reduction system. The time for intraoperative registration and navigation averaged 47.4 min (from 32 to 74 min), the autonomous reduction time 73.9 min (from 48 to 96 min), and the total operation time 121.3 min (from 83 to 170 min). The reduction error averaged 2.02 mm (from 1.67 to 2.62 mm), and the reduction results met the clinical requirements.Conclusion:Our self-designed intelligent robot-assisted minimally invasive reduction system is a new clinical solution for unstable pelvic fractures, showing advantages of agreement with clinical operative procedures, high reduction accuracy and operational feasibility, and reduced radiation exposure compared to a conventional operation.
6.Efficient expansion of rare human circulating hematopoietic stem/progenitor cells in steady-state blood using a polypeptide-forming 3D culture.
Yulin XU ; Xiangjun ZENG ; Mingming ZHANG ; Binsheng WANG ; Xin GUO ; Wei SHAN ; Shuyang CAI ; Qian LUO ; Honghu LI ; Xia LI ; Xue LI ; Hao ZHANG ; Limengmeng WANG ; Yu LIN ; Lizhen LIU ; Yanwei LI ; Meng ZHANG ; Xiaohong YU ; Pengxu QIAN ; He HUANG
Protein & Cell 2022;13(11):808-824
Although widely applied in treating hematopoietic malignancies, transplantation of hematopoietic stem/progenitor cells (HSPCs) is impeded by HSPC shortage. Whether circulating HSPCs (cHSPCs) in steady-state blood could be used as an alternative source remains largely elusive. Here we develop a three-dimensional culture system (3DCS) including arginine, glycine, aspartate, and a series of factors. Fourteen-day culture of peripheral blood mononuclear cells (PBMNCs) in 3DCS led to 125- and 70-fold increase of the frequency and number of CD34+ cells. Further, 3DCS-expanded cHSPCs exhibited the similar reconstitution rate compared to CD34+ HSPCs in bone marrow. Mechanistically, 3DCS fabricated an immunomodulatory niche, secreting cytokines as TNF to support cHSPC survival and proliferation. Finally, 3DCS could also promote the expansion of cHSPCs in patients who failed in HSPC mobilization. Our 3DCS successfully expands rare cHSPCs, providing an alternative source for the HSPC therapy, particularly for the patients/donors who have failed in HSPC mobilization.
Antigens, CD34/metabolism*
;
Hematopoietic Stem Cell Transplantation
;
Hematopoietic Stem Cells
;
Humans
;
Leukocytes, Mononuclear/metabolism*
;
Peptides/metabolism*
7.The application of intraoperative transesophageal echocardiography in systolic anterior motion after mitral valvuloplasty
Na ZHAO ; Qinghua QI ; Juan YANG ; Jiangchuan DU ; Suyun HOU ; Honghu WANG ; Ruifang ZHANG
Chinese Journal of Ultrasonography 2021;30(2):105-111
Objective:To predict the risk of systolic anterior motion (SAM) after mitral valvuloplasty(MVP) by intraoperative transesophageal echocardiography (TEE) and its diagnostic value.Methods:From August 2016 to May 2020, 215 patients with mitral valve degeneration underwent MVP, including 182 patients without SAM (non-SAM group), and 33 patients with SAM (SAM group). TEE examination was performed immediately after operation to determine whether SAM phenomenon was relieved. According to the physiological basis of SAM, before cardiopulmonary bypass (CPB) and immediately after CPB, the parameters of SAM group and non-SAM group were measured and compared, including left atrial dimension(LAD), left ventricular end diastolic diameter(LVEDD), left ventricular end systolic diameter(LVESD), left ventricular ejection fraction(LVEF), basal septal diameter(basal-IVDd), left ventricular posterior wall thickness(LVPW), left ventricular outflow tract diameter(LVOTD), left ventricular outflow tract maximum velocity(LVOT-Vmax), left ventricular outflow tract pressure gradient(LVOTG), mitral valve maximum velocity(MV-Vmax), mitral valve mean pressure gradient(MVG-mean), mitral regurgitation area(MR-area), bulging subaortic septum, anterior leaflet length, posterior leaflet length, ratio between the lengths of the anterior and posterior leaflets, coaptation-septum distance(c-sept), nnular diameter of mitral valve, aorto-mitral angle (AMA) to screen the independent risk factors of SAM after MVP.Results:① Compared with the non-SAM group, LVEDd, LVESD, ratio between the length of the anterior and posterior leaflets, c-sep and AMA decreased in SAM group (all P<0.05), while basal-IVDd, LVEF, posterior leaflet length and bulging subaortic septum increased in SAM group (all P<0.05). ②Compared with that before the "edge to edge" technique, LVOT-Vmax decreased from (4.31±2.26)m/s to (2.55±1.39)m/s, LVOTG decreased from (43.58±10.89)mmHg to (23.36±12.76)mmHg, MVG-mean increased from (0.46±0.33)mmHg to (2.27±0.43)mmHg, and MR-area increased from (3.52±0.79)cm 2 to (0.96±0.57)cm 2 (all P<0.05). ③Multivariate logistic regression analysis showed that independent risk factors of SAM were LVEDd<45.430 mm ( OR=0.267, 95% CI=0.084-0.847), basal-IVDd>14.870 mm ( OR=12.049, 95% CI=1.619-89.661), length ratio of anterior and posterior leaflets of mitral valve>1.371 ( OR=0.159, 95% CI=0.045-0.562), angle of bulging angulated subaortic septum>62.330°( OR=18.246, 95% CI=2.824-117.896), c-sept<23.965 mm( OR=0.177, 95% CI=0.05-0.628), and AMA<123.730°( OR=0.197, 95% CI=0.098-0.396). Conclusions:Intraoperative TEE can evaluate the risk factors of SAM before MVP, and find the SAM phenomenon after MVP in time, which is helpful for surgeons to prevent and correct SAM after MVP and avoid secondary operation.
8.Multidisciplinary team for the diagnosis and treatment of congenital band syndrome
Changying ZHAO ; Hang ZHANG ; Lingxia LI ; Yanhong LYU ; Rui SHU ; Yu WANG ; Honghu JIN ; Rui CONG
Chinese Journal of Applied Clinical Pediatrics 2021;36(20):1576-1578
Objective:To explore the significance of multidisciplinary team for the diagnosis and treatment of congenital band syndrome.Methods:Five children with congenital circular band syndrome admitted in the First Affiliated Hospital of the Chinese People′s Liberation Army Air Force Medical University from January 2017 to January 2020 were retrospectively analyzed.They were diagnosed, treated and followed up by a multidisciplinary team including the department of obstetrics and gynecology, ultrasound, and orthopedics from the fetal stage.Results:One case was found with gradually aggravated ring band that affects the blood circulation of distal limbs during fetal examination, who was promptly performed with partial band release under fetoscopy.All cases had Patterson type Ⅰ ring bands at birth, and distal limbs did not have obvious deformity.They were performed with selective annular band resection, and postoperatively followed up for an average of 10.6 (8-13) months.The annular depression of the skin disappeared, and the appearance and function recovered satisfactory.According to the monitoring of side effects scale (Moses), 4 cases were excellent, 1 case was good, and the excellent and good rate was 100%.Conclusions:The multidisciplinary team for the diagnosis and treatment of congenital band syndrome can maximize the professional advantages of physicians with diffe-rent specialties, make early diagnosis and treatment, minimize the compression of the ring band on the limbs, and avoid serious limb deformities.It is worthy of clinical application.
9.A retrospective study of infection prevention in emergency and confined operations at Department of Orthopaedic Trauma, Beijing Jishuitan Hospital during the epidemic of COVID-19
Honghu XIAO ; Ting LI ; Ruofei MA ; Kaiwen WANG ; Gang LIU ; Jing WANG ; Zhijian SUN ; Shiwen ZHU ; Maoqi GONG ; Minghui YANG ; Hui CHEN ; Xinbao WU
Chinese Journal of Orthopaedic Trauma 2020;22(7):556-560
Objective:To summarize our experience in prevention of COVID-19 infection in emergency and confined operations during the first 3 weeks after Spring Festival in 2020.Methods:From February 3rd to 23rd, 2020, 151 patients were admitted to Department of Orthopaedic Trauma, Beijing Jishuitan Hospital for emergency and confined operations. In this cohort, 125 patients were admitted to ordinary wards. They were 70 males and 55 females with an age of 51.1 years ± 14.9 years. Of them, 2 were subjected to emergency operation and 123 to confined operation. The mean time from injury to operation was 9.9 days ± 6.1 days. There were 26 cases in the senile wards, 7 males and 19 females with an age of 80.8 years ± 7.0 years all of whom underwent confined operations. The mean time from injury to operation was 8.4 days ± 6.3 days. The protocols for emergency diagnosis, admission, emergency and confined operations, postoperative rehabilitation and management of suspects with COVID-19 during the epidemic of COVID-19 were optimized according to Diagnosis and Treatment Protocols for Novel Coronavirus Pneumonia (Trial version 5), emergency responding pre-plans of our hospital, and our experience in Enhanced Recovery After Surgery (ERAS) as well.Results:The patients in the ordinary wards had a hospital stay of 6.8 days ± 4.6 days while those in the senile wards 5.1 days ± 2.0 days. Abnormal temperature (≥37.3 ℃) was observed perioperatively in 17 cases in the ordinary wards. It was absorption fever in all and appeared in 4 cases upon admission. Fever appeared in 11 patients in the senile wards and upon admission in 3 of them. One senile patient who had been diagnosed of normal pneumonia returned to normal temperature and remained stable conditions after antibiotic therapy. The other patients were free of complications related to COVID-19 during their hospital stay.Conclusion:The first-line medical staff working at emergency department, wards and surgical theaters must heighten their vigilance against COVID-19 infection and rigorously follow protocols for prevention of COVID-19 infection in their daily clinical practice.
10. Establishment and clinical performance evaluation of 2019 novel coronavirus antibody colloidal gold detection method
Hui LI ; Yongyin LI ; Zhigao ZHANG ; Zhen LU ; Yi WANG ; Guanfeng LIN ; Taixue AN ; Xiumei HU ; Qintao LAI ; Xuan YI ; Zhihong LIU ; Xiangming ZHAI ; Jian SUN ; Yabing GUO ; Jiatao LU ; Xiaoyong ZHANG ; Yingsong WU ; Jinlin HOU
Chinese Journal of Infectious Diseases 2020;38(0):E017-E017
Objective:
To establish a colloidal gold technique assay for the rapid detection of immunoglobulin(Ig) M and IgG antibodies against 2019 novel coronavirus (2019-nCoV) and to evaluate its clinical performance.
Methods:
A total of 278 patients who were treated at Wuhan Hankou Hospital and the People's Hospital of Honghu from February 12, 2020 to February 20, 2020 were collected. According to the diagnostic criteria, 89 patients were confirmed with 2019-nCoV nucleic acid positive diagnosis, and 189 were 2019-nCoV nucleic acid-negative suspected patients. A total of 273 medical examiners from Nanfang Hospital, Southern Medical University from 2015 to 2018 were selected as controls. The serum samples of patients were collected. 2019-nCoV nucleic proteins were obtained from prokaryotic expression vectors. Indirect IgM and IgG colloidal gold techniques were established by using recombinant N protein. 2019-nCoV nucleic acid detection by reverse transcription-polymerase chain reaction (RT-PCR) was used as control. Serum specimens were tested for 2019-nCoV IgM and IgG. The specificity and sensitivity of colloidal gold assay were analyzed.
Results:
The sensitivity and specificity of IgM detection reagents were 78.7% and 98.2%, respectively, those of IgG detection reagents were 73.0% and 99.3%, respectively, and those of IgM combined with IgG detection were 87.6% and 98.2%, respectively. For suspected patients with negative 2019-nCoV nucleic acid, the positive rates of IgM and IgG were 59.8% (113/189) and 52.9% (100/189), respectively, and the positive rate of IgM combined with IgG detection was 66.1% (125/189).
Conclusion
This reagent of 2019-nCoV antibodies detection (colloidal gold technique) fulfills the requirement for clinical application with high specificity and sensitivity, which can be served as a supplementary detection method for 2019-nCoV nucleic acid detection by RT-PCR.

Result Analysis
Print
Save
E-mail