1.Genotype and phenotype correlation analysis of retinitis pigmentosa-associated RHO gene mutation in a Yi pedigree
Yajuan ZHANG ; Hong YANG ; Hongchao ZHAO ; Dan MA ; Meiyu SHI ; Weiyi ZHENG ; Xiang WANG ; Jianping LIU
International Eye Science 2025;25(3):499-505
AIM: To delineate the specific mutation responsible for retinitis pigmentosa(RP)in a Yi pedigree, and to analyze the correlation of RHO gene mutation with clinical phenotype.METHODS:A comprehensive clinical evaluation was conducted on the proband diagnosed with RP and other familial members, complemented by a thorough ophthalmic examination. Peripheral blood samples were obtained from the proband and familial members, from which genomic DNA was extracte. Subsequent whole exome sequencing(WES)was employed to identify the variant genes in the proband. The identified variant gene was validated through Sanger sequencing, then an in-depth analysis of the mutation genes was carried out using genetic databases to ascertain the pathogenic mutation sites. Furthermore, an exhaustive analysis was performed to delineate the genotype and phenotype characteristics.RESULTS:The RP pedigree encompasses 5 generations with 42 members, including 19 males and 23 females. A total of 13 cases of RP were identified, consisting of 4 males and 9 females, which conforms to the autosomal dominant inheritance pattern. The clinical features of this family include an early onset age, rapid progression, and a more severe condition. The patients were found to have night blindness around 6 years old, representing the earliest reported case of night blindness in RP families. The retina was manifested by progressive osteocytoid pigmentation of the fundus, a reduced visual field, and significantly decreased or even vanished a and b amplitudes of ERG. The combined results of WES and Sanger sequencing indicated that the proband had a heterozygous missense mutation of the RHO gene c.1040C>T:p.P347L, where the 1 040 base C of cDNA was replaced by T, causing codon 347 to encode leucine instead of proline. Interestingly, this mutation has not been reported in the Chinese population.CONCLUSION:This study confirmed that the mutant gene of RP in a Yi nationality pedigree was RHO(c.1040C>T). This variant leads to the change of codon 347 from encoding proline to encoding leucine, resulting in a severe clinical phenotype among family members. This study provides a certain molecular, clinical, and genetic basis for genetic counseling and gene diagnosis of RHO.
2.Genotype and phenotype correlation analysis of retinitis pigmentosa-associated RHO gene mutation in a Yi pedigree
Yajuan ZHANG ; Hong YANG ; Hongchao ZHAO ; Dan MA ; Meiyu SHI ; Weiyi ZHENG ; Xiang WANG ; Jianping LIU
International Eye Science 2025;25(3):499-505
AIM: To delineate the specific mutation responsible for retinitis pigmentosa(RP)in a Yi pedigree, and to analyze the correlation of RHO gene mutation with clinical phenotype.METHODS:A comprehensive clinical evaluation was conducted on the proband diagnosed with RP and other familial members, complemented by a thorough ophthalmic examination. Peripheral blood samples were obtained from the proband and familial members, from which genomic DNA was extracte. Subsequent whole exome sequencing(WES)was employed to identify the variant genes in the proband. The identified variant gene was validated through Sanger sequencing, then an in-depth analysis of the mutation genes was carried out using genetic databases to ascertain the pathogenic mutation sites. Furthermore, an exhaustive analysis was performed to delineate the genotype and phenotype characteristics.RESULTS:The RP pedigree encompasses 5 generations with 42 members, including 19 males and 23 females. A total of 13 cases of RP were identified, consisting of 4 males and 9 females, which conforms to the autosomal dominant inheritance pattern. The clinical features of this family include an early onset age, rapid progression, and a more severe condition. The patients were found to have night blindness around 6 years old, representing the earliest reported case of night blindness in RP families. The retina was manifested by progressive osteocytoid pigmentation of the fundus, a reduced visual field, and significantly decreased or even vanished a and b amplitudes of ERG. The combined results of WES and Sanger sequencing indicated that the proband had a heterozygous missense mutation of the RHO gene c.1040C>T:p.P347L, where the 1 040 base C of cDNA was replaced by T, causing codon 347 to encode leucine instead of proline. Interestingly, this mutation has not been reported in the Chinese population.CONCLUSION:This study confirmed that the mutant gene of RP in a Yi nationality pedigree was RHO(c.1040C>T). This variant leads to the change of codon 347 from encoding proline to encoding leucine, resulting in a severe clinical phenotype among family members. This study provides a certain molecular, clinical, and genetic basis for genetic counseling and gene diagnosis of RHO.
3.Efficacy and safety of proximal gastrectomy versus total gastrectomy for Siewert type Ⅱ and Ⅲ adenocarcinoma of the esophagogastric junction: A systematic review and meta-analysis
Yingjie LU ; Ziqiang HONG ; Hongchao LI ; Gang JIN ; Wenhao WANG ; Yi YANG ; Bin LIU ; Zijiang ZHU
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(05):693-699
Objective To systematically evaluate the efficacy and safety of proximal gastrectomy (PG) versus total gastrectomy (TG) for the treatment of Siewert type Ⅱ/Ⅲ adenocarcinoma of the esophagogastric junction (AEG). Methods PubMed, The Cochrane Library, Web of Science, EMbase, CNKI, Wanfang, and VIP databases were searched for literature comparing the efficacy and safety of PG and TG for the treatment of Siewert type Ⅱ/Ⅲ AEG. The search period was from database inception to March 2023. Meta-analysis was performed using Review Manager 5.4 software. Results A total of 23 articles were included, including 16 retrospective cohort studies, 5 prospective cohort studies, and 2 randomized controlled trials. The total sample size was 2 826 patients, with 1 389 patients undergoing PG and 1 437 patients undergoing TG. Meta-analysis results showed that compared with TG, PG had less intraoperative blood loss [MD=−19.85, 95%CI (−37.20, −2.51), P=0.02] and shorter postoperative hospital stay [MD=−1.23, 95%CI (−2.38, −0.08), P=0.04]. TG had a greater number of lymph nodes dissected [MD=−6.20, 95%CI (−7.68, −4.71), P<0.001] and a lower incidence of reflux esophagitis [MD=3.02, 95%CI (1.24, 7.34), P=0.01]. There were no statistically significant differences between the two surgical approaches in terms of operative time, postoperative survival rate (1-year, 3-year, 5-year), and postoperative overall complications (P>0.05). Conclusion PG has advantages in terms of intraoperative blood loss and postoperative hospital stay, while TG has advantages in terms of the number of lymph nodes dissected and the incidence of reflux esophagitis. There is no significant difference in long-term survival between the two surgical approaches.
4.Development of an online radioactive xenon gas monitoring system for nuclear facilities
Luzhen GUO ; Hongchao PANG ; Chuangao WANG ; Yanbiao ZHANG ; Ying WANG ; Mengmeng WU ; Xinfang DONG ; Ling CHEN
Chinese Journal of Radiological Health 2024;33(1):56-60
Objective Nowadays, radioactive xenon isotopes, including 131mXe, 133mXe, 133Xe, and 135Xe, are primarily released into the atmosphere through various reactor operation and major accidents of reactors. To improve the online monitoring capability of xenon in nuclear facilities and their gaseous effluents, a highly sensitive online xenon monitoring system was developed to monitor, warn, and alarm the activity concentration of radioactive xenon. Methods The online monitoring system for radioactive xenon gas in nuclear facilities was established using xenon membrane separation and concentration, xenon high-efficiency selective adsorption, and low-background gamma-ray spectrometry analysis methods. Results Under the operation mode of one-hour sampling and one-hour measuring, the minimum detectable activity concentration of the radioactive xenon online monitoring system for 133Xe was approximately (1.43 ± 0.03) Bq/m3. Conclusion This system can be effectively used for online monitoring of xenon activity concentration in nuclear facilities such as nuclear power plants and isotope production reactors, as well as in gaseous effluents. It helps improve the safety level of personnel, the environment, and nuclear facilities.
5.Development of a mobile personnel radiation protection equipment
Yuan HE ; Hongchao PANG ; Yang LIU ; Jianhua WU ; Junlin WANG ; Yanan HONG ; Xubiao CHEN ; Hualin WANG ; Xiaoyu SHI ; Miao PAN ; Qiang WANG
Chinese Journal of Radiological Health 2024;33(2):158-163
Objective To design a mobile personnel radiation protection equipment for operation in environments with high radiation such as spent fuel reprocessing plants, to achieve simultaneous protection against γ radiation, neutron radiation, and radioactive aerosol, to reduce the internal and external exposure dose of radioactive workers, and to meet the requirement of operation for two hours. Methods The core parts of the mobile personnel radiation protection equipment included a shielding chamber and a respiratory maintenance system. An automated chassis was used for the movement and lifting of the shielding chamber. MCNP software was used to simulate and calculate the protective effects of shielding chamber made of different materials and material thicknesses. Experimental verification of the shielding chamber design was conducted. Mathematical models were established to describe the variations in the content of various gases in the chamber with personnel operation time. A respiratory maintenance system, a harmful gas absorption device, and an automated mobile chassis were designed. Results The shielding chamber made of polyethylene with a thickness of 80 mm achieved an 80% neutron shielding rate. The respiratory maintenance system could support workers for 2 hours of operation inside the equipment. The mobile chassis allowed operation of the equipment with one person. Conclusion This mobile personnel radiation protection equipment can solve the problem in simultaneous protection against γ radiation, neutron radiation, and radioactive aerosol. The equipment can provide radiation protection for radioactive workers, reduce exposure dose, and reduce personnel burden. This system provides technical means for the operation and maintenance of equipment in high-radiation sites such as spent fuel reprocessing plants.
6.Calculation of organ dose of 90Y TheraSphere in the treatment of pancreatic cancer
Jiangxia WANG ; Wei WANG ; Chuangao WANG ; Jinsen GUO ; Hongchao PANG
Chinese Journal of Radiological Health 2024;33(3):234-241
Objective To calculate the absorbed dose of 90Y TheraSphere in the pancreas and the surrounding sensitive organs after the administration in the treatment of pancreatic cancer through the establishment of an individual voxel model, and to provide technical support for the clinical application of 90Y TheraSphere in the treatment of pancreatic cancer. Methods An individualized voxel model was constructed in Geant4 software based on the CT images of the patient. 12 monoenergetic electron specific absorption fractions (SAFs) in the range of 0.01 to 1 MeV were calculated and validated against the ICRP data. The model and method were used to calculate the absorbed doses in the target organs under uniform and nonuniform distribution of 90Y microspheres in the pancreas. Results The relative errors between the SAF values calculated based on the individualized voxel model and the ICRP data after mass calibration were less than 3.89%. When 90Y was uniformly distributed in the pancreas, the absorbed dose in the pancreas was 4.69 × 10−7 Gy/Bq; the absorbed doses in the liver, kidneys, and spleen were 6.15 × 10−12, 6 × 10−12, and 1.65 × 10−11 Gy/Bq, respectively. When 90Y was distributed within the tumor, the absorbed dose in the tumor was 6.69 × 10−6 Gy/Bq and the absorbed dose in normal pancreas was 5.72 × 10−8 Gy/Bq. The fitted relationship between tumor volume V and administered activity A at the prescribed dose of 120 Gy was quadratic, with relatively low activity required for concentrated administration in the center of the tumor. Conclusion The Monte Carlo dose calculation method based on individual voxel model accurately predicted the absorbed doses in the surrounding sensitive organs (liver, kidneys, and spleen) when 90Y TheraSphere was used to treat pancreatic cancer. These results and the analysis of the factors affecting the drug delivery activity will provide data support for the clinical research of 90Y TheraSphere in pancreatic cancer.
7.Simulation and analysis of an imaging detection device for wound contamination caused by transuranic nuclides
Yujian WANG ; Wei WANG ; Xinglong LI ; Chuangao WANG ; Hongchao PANG ; Ling CHEN
Chinese Journal of Radiological Health 2024;33(3):260-266
Objective To address the radioactive contamination of wounds caused by transuranic nuclides, wound radiation imaging based on coded aperture imaging technology was investigated. Methods By simulating multiple source terms using Monte Carlo method, the differences in imaging performance between two image reconstruction algorithms under near-field conditions were compared. The effects of detector pixels and detection plane pixels on image resolution were investigated. Results The imaging system was simulated based on the designed dimensions. The simulated imaging field of view was 89.4 mm × 89.4 mm and the simulated angular resolution was 1.98°. Based on the comparison of the average width at half height of the reconstructed point sources under different conditions, it was found that increasing the number of pixels in the detector and detection plane optimized the angular resolution but significantly prolonged the Monte Carlo simulation time. Conclusion According to the simulation results, the parameters of the imaging system can be used to effectively image radioactive contamination. Our results provide methodological support for the measurement of wound contamination caused by transuranic nuclides, and lay the foundation for the development of wound contamination imaging detection systems in the future.
8.Correlation between preoperative plasma fibrin degradation products level and clinicopathological features in patients with non-small cell lung cancer
Juanjuan CHE ; Jing WANG ; Mu HU ; Hongchao ZHEN ; Haishan LIN ; Kun SHANG ; Bangwei CAO
Cancer Research and Clinic 2024;36(1):1-5
Objective:To investigate the relationship between preoperative plasma fibrin degradation products (FDP) level and clinicopathological features of patients with completely resected non-small cell lung cancer (NSCLC).Methods:A retrospective case series study was performed. The clinical data of 521 patients who were pathologically diagnosed with NSCLC in Beijing Friendship Hospital Affiliated to Capital Medical University from January 2016 to December 2017 were retrospectively analyzed. Among 521 cases, 406 cases were postoperatively pathologically confirmed as non-lymph node and non-distant metastasis (non-metastasis group) and 115 cases were postoperatively pathologically confirmed as lymph node or distant metastasis (metastasis group). The preoperative FDP level and clinicopathological characteristics as well as the clinicopathological characteristics of NSCLC patients with different FDP levels were compared between the two groups. The correlation between preoperative FDP level and TNM staging was analyzed by using Spearman correlation analysis.Results:Among 521 NSCLC patients, 266 cases were female, 255 cases were male; the age [ M( Q1, Q3)] was 59 years (54 years, 65 years); 441 cases were adenocarcinoma and 70 cases were squamous cell carcinoma. The preoperative median FDP level was 2.78 mg/L (2.35 mg/L, 3.13 mg/L) and 2.99 mg/L (2.56 mg/L, 4.16 mg/L), respectively of NSCLC patients in non-metastasis group and metastasis group, and the difference was statistically significant ( Z = 6.13, P < 0.001). The preoperative FDP level was 2.56 mg/L (2.35 mg/L, 3.20 mg/L) and 2.99 mg/L (2.56 mg/L, 3.20 mg/L), respectively in the early-stage NSCLC (stage Ⅰ-Ⅱ) and advanced NSCLC (stage Ⅲ-Ⅳ) patients, and the difference was statistically significant ( Z = 8.42, P < 0.001). Spearman correlation analysis showed that preoperative FDP level was positively correlated with tumor diameter ( r = 0.287, P < 0.001). There was a positive correlation between preoperative FDP level and the number of metastatic lymph nodes in 115 patients with lymph node metastasis ( r = 0.679, P < 0.001). According to the preoperative median FDP (2.78 mg/L), all patients were divided into FDP ≤2.78 mg/L group and FDP >2.78 mg/L, and there were statistically significant differences in age, metastasis, tumor staging, tumor diameter, the metastatic number of lymph node and histological types of NSCLC patients in both groups (all P < 0.05). Conclusions:The increase of preoperative plasma FDP level may be related to the tumor metastasis and clinical stage of NSCLC patients
9.Analysis of the therapeutic effect of aspiration thrombectomy for early carotid stent thrombosis
Peng GUO ; Jianwen JIA ; Yu WANG ; Hongliang ZHONG ; Hongchao YANG ; Jumei HUANG ; Tong LI ; He LIU ; Yang WANG
Chinese Journal of Surgery 2024;62(3):248-255
Objective:To investigate the clinical characteristics and the efficacy of thrombus aspiration in patients with early intrastent thrombosis (EST) following carotid artery stenting (CAS).Methods:This study is a retrospective case series, collecting clinical data of five patients who developed EST after CAS in the Department of Neurosurgery, Beijing Chaoyang Hospital, Capital Medical University from January 2021 to September 2023.All patients were male, with an age of (64.0±11.9) years (range:48 to 77 years), accounting for 2.0% (5/244) of CAS procedures during the same period.Among them, three patients did not receive standard dual antiplatelet therapy before the procedure, and one had an inadequate ADP inhibition rate (45.6%).Four patients received XACT carotid stents, while one received a Wallstent carotid stent.All five patients showed significant residual stenosis ranging from 43% to 55% after CAS.Emergency thrombus aspiration was performed in all cases, and data regarding perioperative conditions, vascular patency, and clinical outcomes were collected.Results:The interval between CAS and the occurrence of EST ranged from 3 hours to 14 days.The main clinical symptoms included sudden onset of consciousness disorders and contralateral limb weakness.None of the patients received preoperative intravenous thrombolysis, and thrombus aspiration was performed during the procedure to restore vascular patency.Four cases underwent balloon angioplasty during the procedure, and two cases utilized overlapping stents.Two patients experienced intraoperative embolization of thrombus to the C 2 segment.In one case, the embolized thrombus was retrieved using an intracranial thrombectomy stent, while in another case, it was aspirated using a guiding catheter.Postoperatively, all patients had a thrombolysis in cerebral infarction grade of 3, and symptoms improved in four cases.One patient showed no improvement in symptoms, and MRI revealed extensive new infarction in the right frontal and insular regions, adjacent to the right lateral ventricle.Regular follow-up examinations after discharge did not reveal restenosis or embolism within the stent.The follow-up period ranged from 7.6 to 21.2 months, with modified Rankin scale scores of 0 to 1 point in four cases and 2 points in one case, indicating good recovery in all patients. Conclusions:Acute intrastent thrombosis is a rare complication after carotid artery stenting.The combined use of percutaneous thrombus aspiration and endovascular techniques, such as balloon angioplasty and stent overlapping, can rapidly restore vessel patency with favorable outcomes.However, further large-scale clinical studies are needed to confirm the effectiveness of these treatments for acute intrastent thrombosis.
10.Diagnostic and intervention value of implantable cardiac monitor in patients over 60 years of age with unexplained syncope
Rui WANG ; Yanfei ZHANG ; Hongchao ZHANG ; Jia WANG ; Shuhui SHEN ; Jiabin TONG ; Junpeng LIU ; You LYU ; Jia CHONG ; Zhilei WANG ; Xin JIN ; Lin SUN ; Xu GAO ; Yan DAI ; Jing LIANG ; Haitao LI ; Tong ZOU ; Jiefu YANG
Chinese Journal of Cardiology 2024;52(7):784-790
Objective:To investigate the value of implantable cardiac monitor (ICM) in the diagnosis and treatment of patients over 60 years old with unexplained syncope.Methods:This was a multi-center, prospective cohort study. Between June 2018 and April 2021, patients over the age of 60 with unexplained syncope at Beijing Hospital, Fuwai Hospital, Beijing Anzhen Hospital and Puren Hospital were enrolled. Patients were divided into 2 groups based on their decision to receive ICM implantation (implantation group and conventional follow-up group). The endpoint was the recurrence of syncope and cardiogenic syncope as determined by positive cardiac arrhythmia events recorded at the ICM or diagnosed during routine follow-up. Kaplan‐Meier survival analysis was used to compare the differences of cumulative diagnostic rate between the 2 groups. A multivariate Cox regression analysis was performed to determine independent predictors of diagnosis of cardiogenic syncope in patients with unexplained syncope.Results:A total of 198 patients with unexplained syncope, aged (72.9±8.25) years, were followed for 558.0 (296.0,877.0) d, including 98 males (49.5%). There were 100 (50.5%) patients in the implantation group and 98 (49.5%) in the conventional follow-up group. Compared with conventional follow-up group, patients in the implantation group were older, more likely to have comorbidities, had a higher proportion of first degree atrioventricular block indicated by baseline electrocardiogram, and had a lower body mass index (all P<0.05). During the follow-up period, positive cardiac arrhythmia events were recorded in 58 (58.0%) patients in the ICM group. The diagnosis rate (42.0% (42/100) vs. 4.1% (4/98), P<0.001) and the intervention rate (37.0% (37/100) vs. 2.0% (2/98), P<0.001) of cardiogenic syncope in the implantation group were higher than those in the conventional follow-up group (all P<0.001). Kaplan-Meier survival analysis showed that the cumulative diagnostic rate of cardiogenic syncope was significantly higher in the implantation group than in the traditional follow-up group ( HR=11.66, 95% CI 6.49-20.98, log-rank P<0.001). Multivariate analysis indicated that ICM implantation, previous atrial fibrillation, diabetes mellitus or first degree atrioventricular block in baseline electrocardiogram were independent predictors for cardiogenic syncope (all P<0.05). Conclusions:ICM implantation improves the diagnosis and intervention rates in patients with unexplained syncope, and increases diagnostic efficiency in patients with unexplained syncope.

Result Analysis
Print
Save
E-mail