1.Design, synthesis and evaluation of oxadiazoles as novel XO inhibitors
Hong-zhan WANG ; Ya-jun YANG ; Ying YANG ; Fei YE ; Jin-ying TIAN ; Chuan-ming ZHANG ; Zhi-yan XIAO
Acta Pharmaceutica Sinica 2025;60(1):164-171
Xanthine oxidase (XO) is an important therapeutic target for the treatment of hyperuricemia and gout. Based on the previously identified potent XO inhibitor
2. Association between index finger and ring finger length ratios and polymorphism of homeobox A11 gene locus among Ningxia college students
Meng-Yi YANG ; Shi-Bo NIU ; Jing ZHANG ; Jie DANG ; Zhan-Bing MA ; Hong LU ; Zheng-Hao HUO
Acta Anatomica Sinica 2024;55(1):62-66
Objective To investigate the association between the index finger and ring finger length ratio (2D ∶ 4D) and of four loci (rs6461992‚ rs6968828‚ rs7801581‚ rs17427875) polymorphism of homeobox (HOX) A11 gene among Ningxia college students. Methods Digit camera was used to collect frontal hand photos of 667 Han college students (348 males and 319 females) from Ningxia province; Image analysis software was used to mark the anatomical points and measure finger lengths of the index and ring fingers of both hands; multiplex PCR was used to detect each locus polymorphisms of HOXA11 gene; statistical software was used to compare and analyze the differences and associations of 2D ∶4D and gene polymorphisms between different genders. Results Among Ningxia Han college students‚ both left hand and right hand 2D ∶ 4D were significantly higher in females than those of in males (all P< 0. 05)‚ and there were no significant sex differences in right-left hand 2D ∶4D; the genotypes and allele frequencies of rs7801581 locus of HOXA11 gene differed significantly between genders (all P < 0. 05)‚ and none of the other locus polymorphisms showed any significant sex differences; only female left hand 2D ∶4D was significantly associated with rs6461992 locus genotype in the relationship between 2D ∶4D and HOXA11 polymorphisms (P<0. 05). Conclusion There were significant sex differences in 2D ∶ 4D among Han college students in Ningxia‚ and the rs6461992 locus polymorphism of HOXA11 gene may be associated with the formation of 2D ∶4D in females.
3.Clinical features and early warning indicators of patients with acute-on-chronic liver failure and bacterial infection
Zhanhu BI ; Linxu WANG ; Haifeng HU ; Hong DU ; Yidi DING ; Xiaofei YANG ; Jiayi ZHAN ; Fei HU ; Denghui YU ; Hongkai XU ; Jianqi LIAN
Journal of Clinical Hepatology 2024;40(4):760-766
ObjectiveTo investigate the clinical features of patients with acute-on-chronic liver failure (ACLF) and bacterial infection and early warning indicators associated with multidrug-resistant infections. MethodsA retrospective analysis was performed for 130 patients with ACLF and bacterial infection who attended The Second Affiliated Hospital of Air Force Medical University from January 1, 2010 to December 31, 2021, and according to the drug susceptibility results, the patients were divided into multidrug-resistant (MDR) bacterial infection group with 80 patients and non-MDR bacterial infection group with 50 patients. General information and laboratory examination results were compared between the two groups to screen for the early warning indicators associated with MDR bacterial infection. The Student’s t-test was used for comparison of normally distributed continuous data with homogeneity of variance between two groups, and the Mann-Whitney U test was used for comparison of non-normally distributed continuous data or continuous data with heterogeneity of variance between two groups; the chi-square test or the Fisher’s exact test was used for comparison of categorical data between two groups. The binary logistic regression analysis and the receiver operating characteristic (ROC) curve were used to assess the predictive value of early warning indicators. ResultsAmong the 130 patients with ACLF and bacterial infection, sputum (27.7%) was the most common specimen for detection, followed by blood (24.6%), urine (18.5%), and ascites (17.7%). Bacterial infections were dominated by Gram-negative bacteria (58.5%). Of all bacteria, Escherichia coli (18.5%), Klebsiella pneumoniae (14.6%), and Enterococcus faecium (13.8%) were the most common pathogens. Gram-positive bacteria had a high resistance rate to the antibacterial drugs such as erythromycin (72.2%), penicillin (57.4%), ampicillin (55.6%), and ciprofloxacin (53.7%), while Gram-negative bacteria had a high resistance rate to the antibacterial drugs such as ampicillin (73.3%), cefazolin (50.0%), and cefepime (47.4%). The patients with ACLF and bacterial infection had a relatively high rate of MDR bacterial infection (61.5%). Comparison of clinical data between the two groups showed that compared with the patients with non-MDR bacterial infection, the patients with MDR bacterial infection had significantly higher levels of alanine aminotransferase (Z=2.089, P=0.037), aspartate aminotransferase (Z=2.063, P=0.039), white blood cell count (Z=2.207, P=0.027), and monocyte count (Z=4.413, P<0.001). The binary logistic regression analysis showed that monocyte count was an independent risk factor for MDR bacterial infection (odds ratio=7.120, 95% confidence interval [CI]: 2.478 — 20.456,P<0.001) and had an area under the ROC curve of 0.686 (95%CI: 0.597 — 0.776) in predicting ACLF with MDR bacterial infection(P<0.001), with the optimal cut-off value of 0.50×109/L, a sensitivity of 0.725, and a specificity of 0.400. ConclusionACLF combined with bacterial infections is mainly caused by Gram-negative bacteria, with the common pathogens of Escherichia coli and Klebsiella pneumoniae and a relatively high MDR rate in clinical practice. An increase in monocyte count can be used as an early warning indicator to distinguish MDR bacterial infection from non-MDR bacterial infection.
4.Biosensor analysis technology and its research progress in drug development of Alzheimer's disease
Shu-qi SHEN ; Jia-hao FANG ; Hui WANG ; Liang CHAO ; Piao-xue YOU ; Zhan-ying HONG
Acta Pharmaceutica Sinica 2024;59(3):554-564
Biosensor analysis technology is a kind of technology with high specificity that can convert biological reactions into optical and electrical signals. In the development of drugs for Alzheimer's disease (AD), according to different disease hypotheses and targets, this technology plays an important role in confirming targets and screening active compounds. This paper briefly describes the pathogenesis of AD and the current situation of therapeutic drugs, introduces three biosensor analysis techniques commonly used in the discovery of AD drugs, such as surface plasmon resonance (SPR), biolayer interferometry (BLI) and fluorescence analysis technology, explains its basic principle and application progress, and summarizes their advantages and limitations respectively.
5.Effect of printing orientation on physical and mechanical properties of 3D printing prosthodontic base resin materials
Xinxin ZHAN ; Lulu CAO ; Dong XIANG ; Hao TANG ; Dandan XIA ; Hong LIN
Journal of Peking University(Health Sciences) 2024;56(2):345-351
Objective:To analyze the influence of forming direction on the surface characteristics,elastic modulus,bending strength and fracture toughness of printed parts and the relationship between forming direction and force direction,and to provide scientific basis and guidance for the clinical applica-tion of oral denture base resin materials.Methods:The 3D printing technology was used to print denture base resin samples.The shape and size of the samples referred to the current standard for testing conven-tional denture base materials.The samples used for physical performance testing were cylindrical(with a diameter of 15 mm and a thickness of 1 mm)and printed at different angles along the Z axis(0°,45°,90°).Scanning electron microscope was used to observe the microscopic topography of the different sam-ples.The color stability of different samples was observed by color stabilizer.The surface roughness of the samples was analyzed by using surface roughness tester.The Vickers hardness was measured to ana-lyze the hardness of the samples.The samples used for mechanical performance testing were rectangular(elastic modulus and bending strength:A length of 64 mm,a width of 10 mm,and a height of 3.3 mm;fracture toughness:A length of 39 mm,a width of 8 mm,and a height of 4 mm),divided into two groups:W group and H group.The W group was printed from the bottom up along the Z axis with the length × width as the bottom surface parallel to the X,Y axis plane,while the H group printed from the bottom up along the Z axis with the length × height as the bottom surface parallel to the X,Y axis plane.The forming angles of both groups were equally divided into 0°,45°,and 90°.The elastic modulus,bending strength and fracture toughness of different samples were studied through universal mechanical testing machine.SPSS 22.0 software was used for statistical analysis.Results:The microscopic topogra-phy and roughness of different samples were closely related to the printing direction,with significant differences between the 0°,45°,and 90° specimens.The 0° specimens had the smoothest surface(roughness<1 μm).The surface of the 45 ° specimen was the roughest(roughness>3 μm).The microhardness of the 0° sample was the best[(196.13±0.20)MPa],with a significant difference com-pared with the 90° sample[(186.62±4.81)MPa,P<0.05].The mechanical properties of different samples were also closely related to the printing direction.The elastic modulus,bending strength,and fracture toughness of the 45° samples in the W group were the highest compared with the other groups.The results of elastic modulus showed that in the H group,the 45° specimens had the highest elastic mo-dulus,which was significantly different from the 0° and 90° specimens(P<0.05).The elastic modulus of 0° and 45° specimens in the W group were higher than those in 90° specimens(P<0.05).The bending strength results showed that there was no significant difference between the specimens from dif-ferent angles in the H group.The bending strength of the 90° specimens in the W group was the smallest,and there was a significant difference between 90° and the 0° and 45° specimens(P<0.05);And the bendind strength of the 0° and 45° specimens in the W group was significantly higher than that of the 0° and 45° specimens in the H group(P<0.05).The fracture toughness results showed that the fracture toughness of the H group specimens was lower than 1.9 MPa m1/2,which was specified in the denture base standard.The 45° samples in the W group were the highest,with significant differences compared with the 0° and 90° samples(P<0.05).And the 90° samples of the W group specimens were lower than 1.9 MPa m1/2.And the fracture toughness of the 45° specimen in the W group was significantly higher than that of all the specimens in the H group(P<0.05).Conclusion:The 0° samples had rela-tively better physical properties.The 45° samples had the best mechanical properties.But the fracture toughness of specimens(H group and 90° samples of W group)did not yet meet clinical requirements.That indicated that the characteristics of the 3D printing denture base resin were affected by the printing direction.Only when the performance of the printed samples in all directions met the minimum require-ments of the standard,they could be used in clinical practice.
6.Association between index-ring finger length ratio and polymorphisms of 6 phalange-bone development related genes
Meng-Yi YANG ; Shi-Bo NIU ; Jing ZHANG ; Liang PENG ; Jie DANG ; Zhan-Bing MA ; Hong LU ; Zheng-Hao HUO
Acta Anatomica Sinica 2024;55(2):181-187
Objective To investigate the association of 13 single nucleotide polymorphism(SNP)sites in 6 phalange-bone development related genes[fibroblast growth factor receptor 2(FGFR2),indian hedgehog signaling molecule(IHH),Msh homeobox 1(MSX1),Runx family transcription factor 2(RUNX2),SRY-box transcription factor 9(SOX9),Wnt family member 5A(WNT5A)]with human index-ring finger length ratio(2D∶4D).Methods Digital cameras were used to take frontal photographs of the hands of 731 college students(358 males and 373 females)in Ningxia,and image analysis software was used to mark anatomical points and measure finger lengths of index(2th)and ring(4th);genotyping of 13 SNP sites(rs1047057,rs755793,rs41258305,rs3731881,rs3100776,rs12532,rs3821949,rs45585135,rs3749863,rs1042667,rs12601701,rs1829556,rs3732750)for 6 genes by multiplex PCR;One-Way ANOVA or independent sample t-test indirectly assessed the association between 2D∶4D and 13 SNP sites.Results Both left and right hand 2D∶4D were significantly higher in females than males in Ningxia college students(all P<0.01);no statistically significant differences in genotype and allele frequencies of the 13 SNP sites among different sexes(all P>0.05);among different sexes,male left hand 2D∶4D was significantly associated with the genotype of SOX9 gene rs12601701 site(P<0.05)and right hand 2D∶4D was significantly associated with the genotype of WNT5A gene rs1829556 site(P<0.05);the female right hand 2D∶4D was significantly associated with the MSX1 gene rs12532(P<0.01)and rs3821949(P<0.05)sites genotypes.Conclusion SOX9(rs12601701),WNT5A(rs1829556)and MSX1(rs12532 and rs3821949)gene polymorphisms may be associated with the formation of 2D∶4D in Ningxia population.
7.Application and prospect of reconstructing bladder micturition reflex in neurogenic bladder after spinal cord injury
Lifen ZHAN ; Kun AI ; Xuejiu ZENG ; Rouyun LIANG ; Qiangsheng DING ; Hong ZHANG
Chinese Journal of Tissue Engineering Research 2024;28(18):2925-2931
BACKGROUND:The dysfunction of bladder function caused by spinal cord injury is a difficult point in clinical treatment and a hot spot in research.Repairing the injured spinal cord and remodeling the bladder micturition reflex pathway are the fundamental treatment methods. OBJECTIVE:To summarize the reconstruction of the bladder innervation pathway after spinal cord transection injury and its related influencing factors. METHODS:The relevant literature concerning the reconstruction of bladder micturition reflex,neurogenic bladder and urinary reflex and spinal cord repair was retrieved on CNKI,WanFang Data,PubMed and Web of Science.Chinese and English search terms were"neurogenic bladder;spinal cord injury;micturition reflex;spinal cord repair". RESULTS AND CONCLUSION:In the process of reconstructing the bladder micturition reflex,there are many factors involved,including the repair and reconstruction of the injured spinal cord,the remodeling of micturition center,the changes of bladder tissue and substances and hormones in and out of the body.In this process,there are mainly the following problems:(1)As a complex process,there are many sites involved in the reconstruction of the micturition reflex,so the main sites of action can be selected for in-depth study,so as to break through the doubts existing in the reconstruction of the micturition reflex pathway.(2)The mechanism of the normal micturition reflex is complex.After spinal cord transection injury,whether the central nucleus mass controlling or participating in the micturition reflex is compensated and the corresponding compensatory mechanism needs to be further investigated.(3)Information communication between the center and the bladder is interrupted after spinal cord transection injury.Whether there is a direct information connection between the center and the bladder remains to be further investigated.(4)The relationship between reconstructing micturition reflex and body fluid after spinal cord transection injury needs further study.In the reconstruction of the bladder micturition reflex,the key treatment is to promote spinal cord repair,nerve reflex reconstruction,substance metabolism and bladder tissue structure adjustment through intervention.Chinese medicine and Western medicine have their methods.
8.Grey-scale Reversed T1-weighted MRI for Detecting Structural Lesions of the Sacroiliac Joint in Patients with Axial Spondyloarthritis
Ximeng LI ; Wenjuan LI ; Ke ZHANG ; Chaoran LIU ; Yunfei ZHU ; Yingying ZHAN ; Mingzhu LIANG ; Guobin HONG
Journal of Sun Yat-sen University(Medical Sciences) 2024;45(3):412-419
[Objective]To analyze the value of grey-scale reversed T1-weighted(rT1)MRI in the detection of structur-al lesions of the sacroiliac joint(SIJ)in patients with axial spondyloarthritis(ax-SpA).[Methods]Fifty-two ax-SpA pa-tients who underwent both MRI and CT in our hospital within a week from February 2020 to December 2022 were retrospec-tively included.Both sacral and iliac side of each SIJ on oblique coronal images were divided into anterior,middle and pos-terior portion.Two radiologists reviewed independently three groups of MRI including T1-weighted imaging(T1WI),rT1 and T1WI+rT1 images to evaluate the structural lesions like erosions,sclerosis and joint space changes in each of the 6 re-gions of the SIJ.One of the radiologist did the evaluation again one month later.CT images were scored for lesions by a third radiologist and served as the reference standard.Intra-class correlation coefficients(ICC)were calculated to test the inter-and intra-reader agreement for the assessment of SIJ lesions.A Friedman test was performed to compare the lesion results of MRI and CT image findings.We examined the diagnostic performance[accuracy,sensitivity(SE)and specifici-ty]of different groups of MRI in the detection of lesions by using diagnostic test.A McNemar test was used to compare the differences of three groups of MRI findings.[Results]CT showed erosions in 71 joints,sclerosis in 65 and joint space changes in 53.Good inter-and intra-reader agreements were found in three groups of MRI images for the assessment of le-sions,with the best agreement in T1WI+rT1.There were no difference between T1WI+rT1 and CT for the assessment of all lesions,nor between rT1 and CT for the assessment of erosions and joint space changes(P>0.05).T1WI+rT1 yielded better accuracy and SE than T1WI in detection of all lesions(Accuracy erosions:90.3%vs 76.9%;SE erosions:91.6%vs 76.1%;Accu-racy sclerosis:89.4%vs 80.8%;SE sclerosis:84.6%vs 73.9%;Accuracy joint space changes:86.5%vs 73.1%;SE joint space changes:84.9%vs 60.4%;P<0.05).rT1 yielded better accuracy and SE than T1WI in detection of erosions and joint space changes(Accuracy erosions:87.5%vs 76.9%;SE erosions:88.7%vs 76.1%;Accuracy joint space changes:85.6%vs 73.1%;SE joint space changes:83.0%vs 60.4%;P<0.05).[Conclusions]In the detection of SIJ structural lesions in ax-SpA,rT1 improves the diagnostic perfor-mance and T1WI+rT1 is more superior to others.
9.Simultaneous content determination of seventeen constituents in Yangxue Ruanjian Capsules by UPLC-MS/MS
Yong-Ming LIU ; Shu-Sen LIU ; Yi-Zhe XIONG ; Xiang WANG ; Yu-Yun WU ; Jin LIU ; Ling-Yun PAN ; Guo-Qing DU ; Hong-Sheng ZHAN
Chinese Traditional Patent Medicine 2024;46(2):353-358
AIM To establish a UPLC-MS/MS method for the simultaneous content determination of liquiritin apioside,alibiflorin,swertiamarin,methyl gallate,benzoylpaeoniflorin,sweroside,6′-O-β-D-glucosylgentiopicroside,isoliquiritigenin,loganic acid,liquiritigenin,gallic acid,paeoniflorin,oxypaeoniflorin,gentiopicroside,glycyrrhizic acid,isoliquiritoside and liquiritin in Yangxue Ruanjian Capsules.METHODS The analysis was performed on a 40℃thermostatic Waters BEH C18column(2.1 mm×100 mm,1.7 μm),with the mobile phase comprising of 2 mmol/L ammonium acetate(containing 0.1%formic acid)-acetonitrile flowing at 0.3 mL/min in a gradient elution manner,and electron spray ionization source was adopted in negative ion scanning with multiple reaction monitoring mode.RESULTS Seventeen constituents showed good linear relationships within their own ranges(r>0.999 6),whose average recoveries were 91.33%-104.03%with the RSDs of 1.58%-3.50%.CONCLUSION This rapid,accurate and stable method can be used for the quality control of Yangxue Ruanjian Capsules.
10.Clinical effects of Shenxie Zhitong Capsules combined with DONG's Extraordinary Points on patients with knee osteoarthritis of Cold-Dampness Obstruction Pattern
Chinese Traditional Patent Medicine 2024;46(3):821-825
AIM To explore the clinical effects of Shenxie Zhitong Capsules combined with DONG's Extraordinary Points on patients with knee osteoarthritis of Cold-Dampness Obstruction Pattern.METHODS Eighty patients were randomly assigned into control group(40 cases)for 1-month intervention of DONG's Qi Point,and observation group(40 cases)for 1-month intervention of both Shenxie Zhitong Capsules and DONG's Qi Point.The changes in clinical effects,TCM syndrome scores,LKSS score,WOMAC score,NRS score,AIMS2-SF score,sIL-4R,TNF-α,HMGBl,TLR-4,BALP,BGP and β-CTX were detected.RESULTS The observation group demonstrated higher total effective rate than the control group(P<0.05).After the treatment,the two groups displayed decreased TCM syndrome scores,WOMAC score,NRS score,sIL-4R,TNF-α,HMGBl,TLR-4,β-CTX(P<0.05),and increased LKSS score,AIMS2-SF score,BALP,BGP(P<0.05),especially for the observation group(P<0.05).CONCLUSION For the patients of Cold-Dampness Obstruction Pattern,Shenxie Zhitong Capsules combined with DONG's Extraordinary Points can inhibit body inflammatory responses,improve bone metabolism,and relieve knee pain and clinical symptoms.

Result Analysis
Print
Save
E-mail