1.Effect of sphygmomanometer cuff pressure on the differentiation of veins from arteries on ultrasound imaging:an observational cross-sectional study
Tsubouchi MARECHIKA ; Matsui RYOHEI ; Tsubota MAMI ; Yamagishi YOTA ; Miyazaki YUKA ; Murakami HIDEKI ; Hattori TOMONORI ; Sasano HIROSHI
World Journal of Emergency Medicine 2024;15(6):448-454
BACKGROUND:Ultrasound guidance is commonly used for accessing difficult peripheral veins.For successful access,a tourniquet is required for venodilation.Tourniquets decrease the compressibility and increase the diameter of veins;they also obfuscate artery-vein differentiation on ultrasound.We aimed to establish the upper limit of sphygmomanometer cuff pressure that facilitates artery-vein differentiation during ultrasound-guided peripheral intravenous access. METHODS:We employed the sphygmomanometer cuff as a tourniquet for venodilation and tested it on seven participants at six different levels as follows:0 mmHg,DBP/2,DBP,(DBP+SBP)/2,SBP,and SBP+20 mmHg.We used an ultrasound probe attached to a pressure-measuring instrument to record cross-sectional images of the cubital artery and vein.During ultrasonography,compression was applied to the blood vessels through the skin.The following day,we measured the wrist pulse pressure and observed the oximeter pulse wave at six different tourniquet pressure levels.Repeated-measures analysis of variance(ANOVA)on ranks and Tukey's post-hoc analysis were used for multiple comparisons. RESULTS:Arterial pulsation was maintained at tourniquet pressures between 0 mmHg and(DBP+SBP)/2.However,arterial pulsation decreased or disappeared when the tourniquet pressure reached or exceeded the SBP.Moreover,at this pressure level,the superior compressibility of veins compared to that of arteries was no longer observed.Compression of the artery to 75%and 50%of its original diameter increased arterial pulsation. CONCLUSION:Arterial pulsation and the superior compressibility are useful indicators for differentiating veins from arteries until the tourniquet pressure reaches(DBP+SBP)/2.However,these indicators are not reliable once the tourniquet pressure exceeds the SBP.
2.Effect of sphygmomanometer cuff pressure on the differentiation of veins from arteries on ultrasound imaging:an observational cross-sectional study
Tsubouchi MARECHIKA ; Matsui RYOHEI ; Tsubota MAMI ; Yamagishi YOTA ; Miyazaki YUKA ; Murakami HIDEKI ; Hattori TOMONORI ; Sasano HIROSHI
World Journal of Emergency Medicine 2024;15(6):448-454
BACKGROUND:Ultrasound guidance is commonly used for accessing difficult peripheral veins.For successful access,a tourniquet is required for venodilation.Tourniquets decrease the compressibility and increase the diameter of veins;they also obfuscate artery-vein differentiation on ultrasound.We aimed to establish the upper limit of sphygmomanometer cuff pressure that facilitates artery-vein differentiation during ultrasound-guided peripheral intravenous access. METHODS:We employed the sphygmomanometer cuff as a tourniquet for venodilation and tested it on seven participants at six different levels as follows:0 mmHg,DBP/2,DBP,(DBP+SBP)/2,SBP,and SBP+20 mmHg.We used an ultrasound probe attached to a pressure-measuring instrument to record cross-sectional images of the cubital artery and vein.During ultrasonography,compression was applied to the blood vessels through the skin.The following day,we measured the wrist pulse pressure and observed the oximeter pulse wave at six different tourniquet pressure levels.Repeated-measures analysis of variance(ANOVA)on ranks and Tukey's post-hoc analysis were used for multiple comparisons. RESULTS:Arterial pulsation was maintained at tourniquet pressures between 0 mmHg and(DBP+SBP)/2.However,arterial pulsation decreased or disappeared when the tourniquet pressure reached or exceeded the SBP.Moreover,at this pressure level,the superior compressibility of veins compared to that of arteries was no longer observed.Compression of the artery to 75%and 50%of its original diameter increased arterial pulsation. CONCLUSION:Arterial pulsation and the superior compressibility are useful indicators for differentiating veins from arteries until the tourniquet pressure reaches(DBP+SBP)/2.However,these indicators are not reliable once the tourniquet pressure exceeds the SBP.
3.Effect of sphygmomanometer cuff pressure on the differentiation of veins from arteries on ultrasound imaging:an observational cross-sectional study
Tsubouchi MARECHIKA ; Matsui RYOHEI ; Tsubota MAMI ; Yamagishi YOTA ; Miyazaki YUKA ; Murakami HIDEKI ; Hattori TOMONORI ; Sasano HIROSHI
World Journal of Emergency Medicine 2024;15(6):448-454
BACKGROUND:Ultrasound guidance is commonly used for accessing difficult peripheral veins.For successful access,a tourniquet is required for venodilation.Tourniquets decrease the compressibility and increase the diameter of veins;they also obfuscate artery-vein differentiation on ultrasound.We aimed to establish the upper limit of sphygmomanometer cuff pressure that facilitates artery-vein differentiation during ultrasound-guided peripheral intravenous access. METHODS:We employed the sphygmomanometer cuff as a tourniquet for venodilation and tested it on seven participants at six different levels as follows:0 mmHg,DBP/2,DBP,(DBP+SBP)/2,SBP,and SBP+20 mmHg.We used an ultrasound probe attached to a pressure-measuring instrument to record cross-sectional images of the cubital artery and vein.During ultrasonography,compression was applied to the blood vessels through the skin.The following day,we measured the wrist pulse pressure and observed the oximeter pulse wave at six different tourniquet pressure levels.Repeated-measures analysis of variance(ANOVA)on ranks and Tukey's post-hoc analysis were used for multiple comparisons. RESULTS:Arterial pulsation was maintained at tourniquet pressures between 0 mmHg and(DBP+SBP)/2.However,arterial pulsation decreased or disappeared when the tourniquet pressure reached or exceeded the SBP.Moreover,at this pressure level,the superior compressibility of veins compared to that of arteries was no longer observed.Compression of the artery to 75%and 50%of its original diameter increased arterial pulsation. CONCLUSION:Arterial pulsation and the superior compressibility are useful indicators for differentiating veins from arteries until the tourniquet pressure reaches(DBP+SBP)/2.However,these indicators are not reliable once the tourniquet pressure exceeds the SBP.
4.Effect of sphygmomanometer cuff pressure on the differentiation of veins from arteries on ultrasound imaging:an observational cross-sectional study
Tsubouchi MARECHIKA ; Matsui RYOHEI ; Tsubota MAMI ; Yamagishi YOTA ; Miyazaki YUKA ; Murakami HIDEKI ; Hattori TOMONORI ; Sasano HIROSHI
World Journal of Emergency Medicine 2024;15(6):448-454
BACKGROUND:Ultrasound guidance is commonly used for accessing difficult peripheral veins.For successful access,a tourniquet is required for venodilation.Tourniquets decrease the compressibility and increase the diameter of veins;they also obfuscate artery-vein differentiation on ultrasound.We aimed to establish the upper limit of sphygmomanometer cuff pressure that facilitates artery-vein differentiation during ultrasound-guided peripheral intravenous access. METHODS:We employed the sphygmomanometer cuff as a tourniquet for venodilation and tested it on seven participants at six different levels as follows:0 mmHg,DBP/2,DBP,(DBP+SBP)/2,SBP,and SBP+20 mmHg.We used an ultrasound probe attached to a pressure-measuring instrument to record cross-sectional images of the cubital artery and vein.During ultrasonography,compression was applied to the blood vessels through the skin.The following day,we measured the wrist pulse pressure and observed the oximeter pulse wave at six different tourniquet pressure levels.Repeated-measures analysis of variance(ANOVA)on ranks and Tukey's post-hoc analysis were used for multiple comparisons. RESULTS:Arterial pulsation was maintained at tourniquet pressures between 0 mmHg and(DBP+SBP)/2.However,arterial pulsation decreased or disappeared when the tourniquet pressure reached or exceeded the SBP.Moreover,at this pressure level,the superior compressibility of veins compared to that of arteries was no longer observed.Compression of the artery to 75%and 50%of its original diameter increased arterial pulsation. CONCLUSION:Arterial pulsation and the superior compressibility are useful indicators for differentiating veins from arteries until the tourniquet pressure reaches(DBP+SBP)/2.However,these indicators are not reliable once the tourniquet pressure exceeds the SBP.
5.Effect of sphygmomanometer cuff pressure on the differentiation of veins from arteries on ultrasound imaging:an observational cross-sectional study
Tsubouchi MARECHIKA ; Matsui RYOHEI ; Tsubota MAMI ; Yamagishi YOTA ; Miyazaki YUKA ; Murakami HIDEKI ; Hattori TOMONORI ; Sasano HIROSHI
World Journal of Emergency Medicine 2024;15(6):448-454
BACKGROUND:Ultrasound guidance is commonly used for accessing difficult peripheral veins.For successful access,a tourniquet is required for venodilation.Tourniquets decrease the compressibility and increase the diameter of veins;they also obfuscate artery-vein differentiation on ultrasound.We aimed to establish the upper limit of sphygmomanometer cuff pressure that facilitates artery-vein differentiation during ultrasound-guided peripheral intravenous access. METHODS:We employed the sphygmomanometer cuff as a tourniquet for venodilation and tested it on seven participants at six different levels as follows:0 mmHg,DBP/2,DBP,(DBP+SBP)/2,SBP,and SBP+20 mmHg.We used an ultrasound probe attached to a pressure-measuring instrument to record cross-sectional images of the cubital artery and vein.During ultrasonography,compression was applied to the blood vessels through the skin.The following day,we measured the wrist pulse pressure and observed the oximeter pulse wave at six different tourniquet pressure levels.Repeated-measures analysis of variance(ANOVA)on ranks and Tukey's post-hoc analysis were used for multiple comparisons. RESULTS:Arterial pulsation was maintained at tourniquet pressures between 0 mmHg and(DBP+SBP)/2.However,arterial pulsation decreased or disappeared when the tourniquet pressure reached or exceeded the SBP.Moreover,at this pressure level,the superior compressibility of veins compared to that of arteries was no longer observed.Compression of the artery to 75%and 50%of its original diameter increased arterial pulsation. CONCLUSION:Arterial pulsation and the superior compressibility are useful indicators for differentiating veins from arteries until the tourniquet pressure reaches(DBP+SBP)/2.However,these indicators are not reliable once the tourniquet pressure exceeds the SBP.
6.Effect of sphygmomanometer cuff pressure on the differentiation of veins from arteries on ultrasound imaging:an observational cross-sectional study
Tsubouchi MARECHIKA ; Matsui RYOHEI ; Tsubota MAMI ; Yamagishi YOTA ; Miyazaki YUKA ; Murakami HIDEKI ; Hattori TOMONORI ; Sasano HIROSHI
World Journal of Emergency Medicine 2024;15(6):448-454
BACKGROUND:Ultrasound guidance is commonly used for accessing difficult peripheral veins.For successful access,a tourniquet is required for venodilation.Tourniquets decrease the compressibility and increase the diameter of veins;they also obfuscate artery-vein differentiation on ultrasound.We aimed to establish the upper limit of sphygmomanometer cuff pressure that facilitates artery-vein differentiation during ultrasound-guided peripheral intravenous access. METHODS:We employed the sphygmomanometer cuff as a tourniquet for venodilation and tested it on seven participants at six different levels as follows:0 mmHg,DBP/2,DBP,(DBP+SBP)/2,SBP,and SBP+20 mmHg.We used an ultrasound probe attached to a pressure-measuring instrument to record cross-sectional images of the cubital artery and vein.During ultrasonography,compression was applied to the blood vessels through the skin.The following day,we measured the wrist pulse pressure and observed the oximeter pulse wave at six different tourniquet pressure levels.Repeated-measures analysis of variance(ANOVA)on ranks and Tukey's post-hoc analysis were used for multiple comparisons. RESULTS:Arterial pulsation was maintained at tourniquet pressures between 0 mmHg and(DBP+SBP)/2.However,arterial pulsation decreased or disappeared when the tourniquet pressure reached or exceeded the SBP.Moreover,at this pressure level,the superior compressibility of veins compared to that of arteries was no longer observed.Compression of the artery to 75%and 50%of its original diameter increased arterial pulsation. CONCLUSION:Arterial pulsation and the superior compressibility are useful indicators for differentiating veins from arteries until the tourniquet pressure reaches(DBP+SBP)/2.However,these indicators are not reliable once the tourniquet pressure exceeds the SBP.
7.Effect of sphygmomanometer cuff pressure on the differentiation of veins from arteries on ultrasound imaging:an observational cross-sectional study
Tsubouchi MARECHIKA ; Matsui RYOHEI ; Tsubota MAMI ; Yamagishi YOTA ; Miyazaki YUKA ; Murakami HIDEKI ; Hattori TOMONORI ; Sasano HIROSHI
World Journal of Emergency Medicine 2024;15(6):448-454
BACKGROUND:Ultrasound guidance is commonly used for accessing difficult peripheral veins.For successful access,a tourniquet is required for venodilation.Tourniquets decrease the compressibility and increase the diameter of veins;they also obfuscate artery-vein differentiation on ultrasound.We aimed to establish the upper limit of sphygmomanometer cuff pressure that facilitates artery-vein differentiation during ultrasound-guided peripheral intravenous access. METHODS:We employed the sphygmomanometer cuff as a tourniquet for venodilation and tested it on seven participants at six different levels as follows:0 mmHg,DBP/2,DBP,(DBP+SBP)/2,SBP,and SBP+20 mmHg.We used an ultrasound probe attached to a pressure-measuring instrument to record cross-sectional images of the cubital artery and vein.During ultrasonography,compression was applied to the blood vessels through the skin.The following day,we measured the wrist pulse pressure and observed the oximeter pulse wave at six different tourniquet pressure levels.Repeated-measures analysis of variance(ANOVA)on ranks and Tukey's post-hoc analysis were used for multiple comparisons. RESULTS:Arterial pulsation was maintained at tourniquet pressures between 0 mmHg and(DBP+SBP)/2.However,arterial pulsation decreased or disappeared when the tourniquet pressure reached or exceeded the SBP.Moreover,at this pressure level,the superior compressibility of veins compared to that of arteries was no longer observed.Compression of the artery to 75%and 50%of its original diameter increased arterial pulsation. CONCLUSION:Arterial pulsation and the superior compressibility are useful indicators for differentiating veins from arteries until the tourniquet pressure reaches(DBP+SBP)/2.However,these indicators are not reliable once the tourniquet pressure exceeds the SBP.
8.Effect of sphygmomanometer cuff pressure on the differentiation of veins from arteries on ultrasound imaging:an observational cross-sectional study
Tsubouchi MARECHIKA ; Matsui RYOHEI ; Tsubota MAMI ; Yamagishi YOTA ; Miyazaki YUKA ; Murakami HIDEKI ; Hattori TOMONORI ; Sasano HIROSHI
World Journal of Emergency Medicine 2024;15(6):448-454
BACKGROUND:Ultrasound guidance is commonly used for accessing difficult peripheral veins.For successful access,a tourniquet is required for venodilation.Tourniquets decrease the compressibility and increase the diameter of veins;they also obfuscate artery-vein differentiation on ultrasound.We aimed to establish the upper limit of sphygmomanometer cuff pressure that facilitates artery-vein differentiation during ultrasound-guided peripheral intravenous access. METHODS:We employed the sphygmomanometer cuff as a tourniquet for venodilation and tested it on seven participants at six different levels as follows:0 mmHg,DBP/2,DBP,(DBP+SBP)/2,SBP,and SBP+20 mmHg.We used an ultrasound probe attached to a pressure-measuring instrument to record cross-sectional images of the cubital artery and vein.During ultrasonography,compression was applied to the blood vessels through the skin.The following day,we measured the wrist pulse pressure and observed the oximeter pulse wave at six different tourniquet pressure levels.Repeated-measures analysis of variance(ANOVA)on ranks and Tukey's post-hoc analysis were used for multiple comparisons. RESULTS:Arterial pulsation was maintained at tourniquet pressures between 0 mmHg and(DBP+SBP)/2.However,arterial pulsation decreased or disappeared when the tourniquet pressure reached or exceeded the SBP.Moreover,at this pressure level,the superior compressibility of veins compared to that of arteries was no longer observed.Compression of the artery to 75%and 50%of its original diameter increased arterial pulsation. CONCLUSION:Arterial pulsation and the superior compressibility are useful indicators for differentiating veins from arteries until the tourniquet pressure reaches(DBP+SBP)/2.However,these indicators are not reliable once the tourniquet pressure exceeds the SBP.
9.The association between employee lifestyles and the rates of mental health-related absenteeism and turnover in Japanese companies
Atsuya FUJIMOTO ; Hiroshi KANEGAE ; Kaori KITAOKA ; Mizuki OHASHI ; Kunio OKADA ; Koichi NODE ; Kenkichi TAKASE ; Hiroshi FUKUDA ; Tomoyuki MIYAZAKI ; Yuichiro YANO
Epidemiology and Health 2024;46(1):e2024068-
We assessed the association of employee lifestyles (e.g., smoking, exercise, drinking, and sleep habits) with mental health-related absenteeism and turnover rates utilizing data from the annual Health and Productivity Management survey by Japan’s Ministry of Economy, Trade and Industry. This analysis included data from 1,748 companies, encompassing 4,199,021 employees. The average proportions of mental health-related absenteeism and employee turnover rates were 1.1±1.0% and 5.0±5.0%, respectively. In multivariable regression models that incorporated all lifestyle factors and confounders, a 1 percentage point increase in the proportion of employees who slept well was associated with reductions in their turnover rate (mean, -0.020%; 95% confidence interval [CI], -0.038 to -0.002) and in mental health-related absenteeism (mean, -0.005%; 95% CI, -0.009 to 0.001). A similar increase in the proportion of employees engaging in regular physical activity corresponded with a 0.005% decrease in the prevalence of mental health-related absenteeism (95% CI, -0.010 to -0.001). A 1 percentage point increase in the proportion of employees who smoked was associated with a 0.013% reduction in mental health-related absenteeism (95% CI, -0.017 to -0.008). Nonetheless, the current study’s observational and cross-sectional design restricted the ability to establish causality between employee lifestyle factors and mental health issues.
10.The association between employee lifestyles and the rates of mental health-related absenteeism and turnover in Japanese companies
Atsuya FUJIMOTO ; Hiroshi KANEGAE ; Kaori KITAOKA ; Mizuki OHASHI ; Kunio OKADA ; Koichi NODE ; Kenkichi TAKASE ; Hiroshi FUKUDA ; Tomoyuki MIYAZAKI ; Yuichiro YANO
Epidemiology and Health 2024;46(1):e2024068-
We assessed the association of employee lifestyles (e.g., smoking, exercise, drinking, and sleep habits) with mental health-related absenteeism and turnover rates utilizing data from the annual Health and Productivity Management survey by Japan’s Ministry of Economy, Trade and Industry. This analysis included data from 1,748 companies, encompassing 4,199,021 employees. The average proportions of mental health-related absenteeism and employee turnover rates were 1.1±1.0% and 5.0±5.0%, respectively. In multivariable regression models that incorporated all lifestyle factors and confounders, a 1 percentage point increase in the proportion of employees who slept well was associated with reductions in their turnover rate (mean, -0.020%; 95% confidence interval [CI], -0.038 to -0.002) and in mental health-related absenteeism (mean, -0.005%; 95% CI, -0.009 to 0.001). A similar increase in the proportion of employees engaging in regular physical activity corresponded with a 0.005% decrease in the prevalence of mental health-related absenteeism (95% CI, -0.010 to -0.001). A 1 percentage point increase in the proportion of employees who smoked was associated with a 0.013% reduction in mental health-related absenteeism (95% CI, -0.017 to -0.008). Nonetheless, the current study’s observational and cross-sectional design restricted the ability to establish causality between employee lifestyle factors and mental health issues.

Result Analysis
Print
Save
E-mail