1.Effectiveness of combined anteversion angle technique in total hip arthroplasty for treatment of ankylosing spondylitis affecting hip joint.
Yuan WANG ; Fang PEI ; Feng WAN ; Zexuan WANG ; Xiaolei LIU ; Kaijin GUO
Chinese Journal of Reparative and Reconstructive Surgery 2024;38(1):15-21
OBJECTIVE:
To explore the effectiveness of the combined anteversion angle technique in total hip arthroplasty (THA) for treating ankylosing spondylitis (AS) affecting the hip joint.
METHODS:
A retrospective analysis was conducted on the clinical data of 73 patients with AS affecting the hip joint who underwent THA between August 2018 and August 2021. According to whether the combined anteversion angle technique was used in THA, the patients were divided into study group (37 cases, combined anteversion angle technique was used in THA) and control group (36 cases, traditional THA). There was no significant difference in baseline data such as gender, age, body mass index, disease duration, preoperative Harris score, range of motion (ROM), acetabular anteversion angle, acetabular abduction angle, femoral anteversion angle, and combined anteversion angle between the two groups ( P>0.05). The operation time, hospital stay, and complications of the two groups were recorded and compared. The Harris score and hip ROM were compared between the two groups before operation, at 1, 3, 6, 12 months after operation, and at last follow-up. The acetabular component anteversion angle, femoral component anteversion angle, acetabular component abduction angle, and component combined anteversion angle were measured postoperatively.
RESULTS:
The operation time in the study group was significantly shorter than that in the control group ( P<0.05), and there was no significant difference in hospital stay between the two groups ( P>0.05). There was no intraoperative complication such as acetabular and proximal femoral fractures, neurovascular injuries in both groups, and the incisions healed by first intention. All patients were followed up 2-3 years, with an average of 2.4 years; there was no significant difference in the follow-up time between the two groups ( P>0.05). During the follow-up period, there was no complication such as hip dislocation, wound infection, delayed wound healing, deep venous thrombosis, and hip dislocation in both groups. The hip Harris score and ROM of the two groups gradually increased with time after operation, and the differences were significant when compared with those before operation ( P<0.05); the above two indicators of the study group were significantly better than those of the control group at each time point after operation ( P<0.05). Extensive bone ingrowth on the surface of the components could be observed in the anteroposterior X-ray films of the hip joint of the two groups at 12 months after operation, and the acetabular components was stable without femoral stem subsidence, osteolysis around the components, and heterotopic ossification. At last follow-up, the acetabular component anteversion angle, femoral component anteversion angle, and component combined anteversion angle in the study group were significantly superior to those in the control group ( P<0.05), except that there was no significant difference in the acetabular component abduction angle between the two groups ( P>0.05).
CONCLUSION
For patients with AS affecting the hip joint, the use of the combined anteversion angle technique during THA effectively promotes the recovery of hip joint function and enhances the postoperative quality of life of patients when compared to traditional THA.
Humans
;
Arthroplasty, Replacement, Hip/methods*
;
Hip Dislocation/surgery*
;
Spondylitis, Ankylosing/surgery*
;
Retrospective Studies
;
Quality of Life
;
Treatment Outcome
;
Hip Joint/surgery*
;
Hip Prosthesis
2.A novel lateral classification of osteonecrosis of femoral head based on CT recons-truction of necrotic area and its clinical verification.
Mincong HE ; Xiaoming HE ; Tianye LIN ; Huan XIAO ; Wei HE ; Qiushi WEI
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(4):423-430
OBJECTIVE:
To analyze the femoral head collapse and the operation of osteonecrosis of the femoral head (ONFH) in different Japanese Investigation Commitee (JIC) types, in order to summarize the prognostic rules of each type of ONFH, and explore the clinical significance of CT lateral subtypes based on reconstruction of necrotic area of C1 type and verify their clinical effect.
METHODS:
A total of 119 patients (155 hips) with ONFH between May 2004 and December 2016 were enrolled in the study. The total hips consisted of 34 hips in type A, 33 in type B, 57 in type C1, and 31 in type C2, respectively. There was no significant difference in age, gender, affected side, or type of ONFH of the patients with differenct JIC types ( P>0.05). The 1-, 2-, and 5-year femoral head collapse and operation of different JIC types were analyzed, as well as the survival rate (with femoral head collapse as the end point) of hip joint between different JIC types, hormonal/non-hormonal ONFH, asymptomatic and symptomatic (pain duration >6 months or ≤6 months), and combined preserved angle (CPA) ≥118.725° and CPA<118.725°. JIC types with significant differences in subgroup surgery and collapse and with research value were selected. According to the location of the necrotic area on the surface of the femoral head, the JIC classification was divided into 5 subtypes in the lateral CT reconstruction, and the contour line of the necrotic area was extracted and matched to the standard femoral head model, and the necrosis of the five subtypes was presented by thermography. The 1-, 2-, and 5-year outcomes of femoral head collapse and operation in different lateral subtypes were analyzed, and the survival rates (with collapse of the femoral head as the end point) between CPA≥118.725° and CPA<118.725° hip in patients with this subtype were compared, as well as the survival rates of different lateral subtypes (with collapse and surgery as the end points, respectively).
RESULTS:
The femoral head collapse rate and operation rate in the 1-, 2-, and 5-year were significantly higher in patients with JIC C2 type than in patients with other hip types ( P<0.05), while in patients with JIC C1 type than in patients with JIC types A and B ( P<0.05). The survival rate of patients with different JIC types was significantly different ( P<0.05), and the survival rate of patients with JIC types A, B, C1, and C2 decreased gradually. The survival rate of asymptomatic hip was significantly higher than that of symptomatic hip, and the survival rate of CPA≥118.725° was significantly higher than that of CPA<118.725° ( P<0.05). The lateral CT reconstruction of type C1 hip necrosis area was selected for further classification, including type 1 in 12 hips, type 2 in 20 hips, type 3 in 9 hips, type 4 in 9 hips, and type 5 in 7 hips. There were significant differences in the femoral head collapse rate and the operation rate among the subtypes after 5 years of follow-up ( P<0.05). The collapse rate and operation rate of types 4 and 5 were 0; the collapse rate and operation rate of type 3 were the highest; the collapse rate of type 2 was high, but the operation rate was lower than that of type 3; the collapse rate of type 1 was high, but the operation rate was 0. In JIC type C1 patients, the survival rate of the hip joint with CPA≥118.725° was significantly higher than that with CPA<118.725° ( P<0.05). In the follow-up with femoral head collapse as the end point, the survival rates of types 4 and 5 were all 100%, while the survival rates of types 1, 2, and 3 were all 0, and the difference was significant ( P<0.05). The survival rate of types 1, 4, and 5 was 100%, of type 3 was 0, and of type 2 was 60%, showing significant difference ( P<0.05).
CONCLUSION
JIC types A and B can be treated by non-surgical treatment, while type C2 can be treated by surgical treatment with hip preservation. Type C1 was classified into 5 subtypes by CT lateral classification, type 3 has the highest risk of femoral head collapse, types 4 and 5 have low risk of femoral head collapse and operation, type 1 has high femoral head collapse rate but low risk of operation; type 2 has high collapse rate, but the operation rate is close to the average of JIC type C1, which still needs to be further studied.
Humans
;
Femur Head/surgery*
;
Femur Head Necrosis/surgery*
;
Retrospective Studies
;
Hip Joint
;
Tomography, X-Ray Computed
4.Analysis of factors associated with the influence of femoral stem anteversion after total hip arthroplasty.
Zheng LIU ; Kai SONG ; Qing JIANG ; Zhihong XU
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(9):1075-1080
OBJECTIVE:
To explore the related factors of femoral stem anteversion (FSA) after total hip arthroplasty (THA), so as to provide reference for clinical design of FSA before operation and reduce the risk of hip dislocation after arthroplasty.
METHODS:
Ninty-three patients (103 hips) who underwent THA between October 2021 and September 2022 and met the selection criteria were selected as the study subjects. Among them, there were 48 males and 45 females with an average age of 58.5 years (range, 25-88 years). Body mass index was 18.00-37.84 kg/m 2, with an average of 24.92 kg/m 2. There were 51 cases (57 hips) of osteonecrosis of femoral head, 35 cases (39 hips) of hip osteoarthritis, and 7 cases (7 hips) of congenital hip dysplasia. Based on CT images, the following indicators were measured: preoperative femoral neck anteversion (FNA), preoperative femoral rotation angle (FRA), preoperative acetabular anteversion (AA), and preoperative combined anteversion (CA; the sum of preoperative FNA and AA); postoperative FSA and the change in femoral anteversion angle (the difference between postoperative FSA and preoperative FNA). Based on preoperative X-ray films, the following indicators were measured: femoral cortical thickness index (CTI) and canal flare index (CFI), the proximal femoral medullary cavity was classified according to Noble classification (champagne cup type, normal type, chimney type), neck-shaft angle (NSA), and femoral offset (FO). Pearson correlation analysis, one-way ANOVA, and Point-biserial correlation analysis were used to investigate the correlation between postoperative FSA, postoperative change in femoral anteversion angle, and patient diagnosis, proximal femoral medullary cavity anatomy type, gender, age, as well as preoperative FNA, FRA, AA, CA, NSA, FO, CTI, and CFI. FSA was used as the dependent variable and the independent variables that may be related to it were included for multiple linear regression analysis.
RESULTS:
Based on CT image measurement, preoperative FNA was (15.96±10.01)°, FRA (3.36±10.87)°, AA (12.94±8.83)°, CA (28.9±12.6)°, postoperative FSA (16.18±11.01)°, and postoperative change in femoral anteversion angle was (0.22±9.98)°. Based on preoperative X-ray films measurements, the CTI was 0.586±0.081; the CFI was 4.135±1.125, with 23 hips classified as champagne cup type, 68 hips as normal type, and 12 hips as chimney type in the proximal femoral medullary cavity anatomy; NSA was (132.87±7.83)°; FO was (40.53±10.11) mm. There was no significant difference between preoperative FNA and postoperative FSA ( t=-0.227, P=0.821). Pearson correlation analysis showed that postoperative FSA was positively correlated with preoperative FNA, preoperative CA, postoperative change in femoral anteversion angle, and age ( P<0.05), while negatively correlated with preoperative FRA ( P<0.05). The postoperative change in femoral anteversion angle were positively correlated with preoperative FRA and postoperative FSA ( P<0.05), and negatively correlated with preoperative CA and FNA ( P<0.05). One-way ANOVA analysis showed that the above two indicators were not correlated with diagnosis and the proximal femoral medullary cavity anatomy type ( P>0.05). Multiple linear regression analysis showed a linear correlation between FSA and FNA, CA, age, and FRA ( F=10.998, P<0.001), and the best fit model was FSA=0.48×FNA-2.551.
CONCLUSION
The factors related to FSA after THA include patient's age, preoperative FNA, CA, FRA and postoperative femoral anteversion, of which preoperative FNA is the most closely related. When designing a surgical plan before surgery, attention should be paid to the patient's preoperative FNA, and if necessary, CT around the hip joint should be scanned to gain a detailed understanding of the proximal femoral anatomical structure.
Female
;
Male
;
Humans
;
Middle Aged
;
Arthroplasty, Replacement, Hip
;
Femur/diagnostic imaging*
;
Femur Neck
;
Femur Head
;
Hip Joint
5.Progress in diagnosis and hip arthroscopic treatment of borderline developmental dysplasia of hip with Cam-type femoroacetabular impingement.
Yinhao HE ; Xiaosheng LI ; Hongwen CHEN ; Qiang PENG ; Tiezhu CHEN
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(5):629-634
OBJECTIVE:
To summarize the biomechanical characteristics, diagnosis, and hip arthroscopic treatment of borderline developmental dysplasia of hip (BDDH) with Cam-type femoroacetabular impingement (Cam FAI).
METHODS:
The literature on BDDH with Cam FAI at home and abroad in recent years was extensively reviewed and analyzed.
RESULTS:
In patients with BDDH and Cam FAI, the femoral neck anteversion angle and femoral neck shaft angle increase, the pelvis tilts, and the acetabulum rotates, resulting in instability of the hip joint. In order to maintain the stability of the hip joint, the direction of biomechanical action of the hip joint has changed, which further affects the anatomical structures such as the proximal femur and acetabular morphology. BDDH with Cam FAI can be diagnosed clinically by combining lateral center edge angle, anterior center edge angle, and acetabular index. BDDH with Cam FAI can be effectively treated through arthroscopic polishing of the edges of the acetabular proliferative bone, excision of Cam malformations, and minimally invasive repair of the glenoid lip and cartilage of the hip joint.
CONCLUSION
Currently, there is no unified standard for the diagnosis and treatment of BDDH with Cam FAI. Minimally invasive treatment of the hip under arthroscopy can achieve good early- and medium-term effectiveness, and has certain advantages in repairing and maintaining the integrity of the glenoid lip and suturing/compression joint capsule. However, the long-term effectiveness needs to be further followed up to determine. The timing of surgery, intraoperative bone edge depth polishing, and joint capsule suturing/compression techniques also need to be further explored.
Humans
;
Femoracetabular Impingement/surgery*
;
Arthroscopy/methods*
;
Hip Joint/surgery*
;
Acetabulum/surgery*
;
Hip Dislocation, Congenital/surgery*
;
Treatment Outcome
;
Retrospective Studies
7.Study on Influencing Factors of Artificial Hip Joint Test Quality Based on ISO/IEC 17025 and GLP.
Tingting LIU ; Jun WANG ; Xiuling HUANG
Chinese Journal of Medical Instrumentation 2023;47(4):449-453
OBJECTIVE:
Taking artificial hip joint test as the object, integrating ISO/IEC 17025 and GLP, and establishing a new set of management requirements for test influence factors.
METHODS:
The requirements of ISO/IEC 17025 and GLP regulations for influencing factors were compared and analyzed, the similarities and differences were found, and the two were integrated to formulate new management requirements for each influencing factor.
RESULTS:
From the personnel, equipment, materials, methods, reports, filing and other factors, a set of management requirements in line with ISO/IEC 17025 and GLP was formulated, so that the laboratory can provide the objective, real and accurate test data for medical equipment manufacturers and regulatory authorities.
CONCLUSIONS
It can improve the test quality of the laboratory and ensure the authenticity and reliability of the test data and conclusions.
Reproducibility of Results
;
Laboratories
;
Hip Joint
8.Structure Design of Hip Joint Parallel Rehabilitation Exoskeleton.
Yajun HUANG ; Huaixian LI ; Yimin GAO ; Lei YANG
Chinese Journal of Medical Instrumentation 2023;47(6):612-616
At present, most of the research on hip exoskeleton robots adopts the method of decoupling analysis of hip joint motion, decoupling the ball pair motion of hip joint into rotational motion on sagittal plane, coronal plane and cross section, and designing it into series mechanism. Aiming at the problems of error accumulation and man-machine coupling in series mechanism, a parallel hip rehabilitation exoskeleton structure is proposed based on the bionic analysis of human hip joint. The structure model is established and the kinematics analysis is carried out. Through the OpenSim software, the curve of hip flexion and extension, adduction and abduction angle in a gait cycle is obtained. The inverse solution of the structure is obtained by the D-H coordinate system method. The gait data points are selected and compared with the inverse solution obtained by ADAMS software simulation. The results show that the inverse solution expression is correct. The parallel hip exoskeleton structure can meet the requirements of the rotation angle of the hip joint of the human body, and can basically achieve the movement of the hip joint, which is helpful to improve the human-computer interaction performance of the exoskeleton.
Humans
;
Exoskeleton Device
;
Hip Joint
;
Gait
;
Biomechanical Phenomena
;
Computer Simulation
9.Research progress on the revision of Metal-on-Metal hip arthroplasty due to adverse reactions to metal debris.
Xin WANG ; Mei-Ping YANG ; Hong-Liang LIU ; Ze-Xin HUANG ; Shu-Chai XU
China Journal of Orthopaedics and Traumatology 2022;35(1):95-98
The choice of friction interface has always been a controversial topic in hip arthroplasty. Although the metal-on-metal (MoM) interface has gradually faded out of our vision, its revision is a clinical difficulty. Adverse reactions to metal debris (ARMD) is the most common indication for MoM hip arthroplasty revision, and the clinical results of hip arthroplasty due to ARMD are not satisfactory. At present, the indications and suggestions for revision of ARMD are not uniform. In this article, the clinical diagnosis, indications of revision, risk factors of prognosis, intraoperative suggestions and reasons for revision of ARMD were summarized. This article briefly introduces the diagnosis and treatment strategies and precautions of hip arthroplasty due to ARMD, in order to provide reference for such patients in clinical practice.
Arthroplasty, Replacement, Hip/adverse effects*
;
Hip Prosthesis/adverse effects*
;
Humans
;
Metal-on-Metal Joint Prostheses/adverse effects*
;
Prosthesis Design
;
Prosthesis Failure
;
Reoperation
10.Evaluation of acetabular anteversion after total hip arthroplasty.
Pu LIU ; Sha WU ; Hong GAO ; Jia-Wang LOU ; Wei ZHANG ; Xu CAI
China Journal of Orthopaedics and Traumatology 2022;35(4):342-345
OBJECTIVE:
To investigate whether the anteversion angle of acetabular prosthesis can be evaluated on the anteroposterior X-ray film of common double hip joint.
METHODS:
Total 32 patients(41 hips) after total hip arthroplasty were selected, including 18 males and 14 females, aged(66.2±4.1) years. All patients completed the positive X-ray film of both hips and plain CT scan of pelvis after operation. Acetabular anteversion was measured by plain CT scan of pelvis, and measured by Saka and other measurement formulas on X-ray film.
RESULTS:
The acetabular anteversion measured by X-ray film was(16.2±5.0)° and that measured by CT was (31.8±9.7)°(P=0.00). In addition, there was a significant linear correlation between X-ray film and CT(Pearson correlation coefficient (r=0.84, P=0.00).
CONCLUSION
CT can accurately measure the acetabular anteversion, but it has obvious disadvantages, such as large radiation, high cost, phantom CT artifact and so on. Although Saka measurement formula can not directly obtain the accurate acetabular anteversion as CT measurement, it has a high correlation with the acetabular anteversion measured by CT. Therefore, the method proposed in this study can also preliminarily evaluate the acetabular anteversion.
Acetabulum/surgery*
;
Arthroplasty, Replacement, Hip/methods*
;
Female
;
Hip Joint/surgery*
;
Hip Prosthesis
;
Humans
;
Male
;
Pelvis

Result Analysis
Print
Save
E-mail