1.Standardization of electronic medical records data in rehabilitation
Yifan TIAN ; Fang XUN ; Haiyan YE ; Ye LIU ; Yingxin ZHANG ; Yaru YANG ; Zhongyan WANG ; Meng ZHANG ; Xiaoxie LIU ; Yanyan YANG ; Bin ZENG ; Mouwang ZHOU ; Yuxiao XIE ; Guangxu XU ; Jiejiao ZHENG ; Mingsheng ZHANG ; Xiangming YE ; Fubiao HUANG ; Qiuchen HUANG ; Yiji WANG ; Di CHEN ; Zhuoying QIU
Chinese Journal of Rehabilitation Theory and Practice 2025;31(1):33-44
ObjectiveTo explore the data standard system of electronic medical records in the field of rehabilitation, focusing on the terminology and coding standards, data structure, and key content categories of rehabilitation electronic medical records. MethodsBased on the Administrative Norms for the Application of Electronic Medical Records issued by the National Health Commission of China, the electronic medical record standard architecture issued by the International Organization for Standardization and Health Level Seven (HL7), the framework of the World Health Organization Family of International Classifications (WHO-FICs), Basic Architecture and Data Standards of Electronic Medical Records, Basic Data Set of Electronic Medical Records, and Specifications for Sharing Documents of Electronic Medical Records, the study constructed and organized the data structure, content, and data standards of rehabilitation electronic medical records. ResultsThe data structure of rehabilitation electronic medical records should strictly follow the structure of electronic medical records, including four levels (clinical document, document section, data set and data element) and four major content areas (basic information, diagnostic information, intervention information and cost information). Rehabilitation electronic medical records further integrated information related to rehabilitation needs and characteristics, emphasizing rehabilitation treatment, into clinical information. By fully applying the WHO-FICs reference classifications, rehabilitation electronic medical records could establish a standardized framework, diagnostic criteria, functional description tools, coding tools and terminology index tools for the coding, indexing, functional description, and analysis and interpretation of diseases and health problems. The study elaborated on the data structure and content categories of rehabilitation electronic medical records in four major categories, refined the granularity of reporting rehabilitation content in electronic medical records, and provided detailed data reporting guidance for rehabilitation electronic medical records. ConclusionThe standardization of rehabilitation electronic medical records is significant for improving the quality of rehabilitation medical services and promoting the rehabilitation process of patients. The development of rehabilitation electronic medical records must be based on the national and international standards. Under the general electronic medical records data structure and standards, a rehabilitation electronic medical records data system should be constructed which incorporates core data such as disease diagnosis, functional description and assessment, and rehabilitation interventions. The standardized rehabilitation electronic medical records scheme constructed in this study can support the improvement of standardization of rehabilitation electronic medical records data information.
2.Standardization of outpatient medical record in rehabilitation setting
Ye LIU ; Qing QIN ; Haiyan YE ; Yifan TIAN ; Yingxin ZHANG ; Yaru YANG ; Zhongyan WANG ; Meng ZHANG ; Xiaoxie LIU ; Yanyan YANG ; Bin ZENG ; Mouwang ZHOU ; Yuxiao XIE ; Guangxu XU ; Jiejiao ZHENG ; Mingsheng ZHANG ; Xiangming YE ; Fubiao HUANG ; Qiuchen HUANG ; Yiji WANG ; Di CHEN ; Zhuoying QIU
Chinese Journal of Rehabilitation Theory and Practice 2025;31(1):45-54
ObjectiveTo analyze the data structure and standards of rehabilitation outpatient medical records, to provide data support for improving the quality of rehabilitation outpatient care and developing medical insurance payment policies. MethodsBased on the normative documents issued by the National Health Commission, Basic Standards for Medical Record Writing and Standards for Electronic Medical Record Sharing Documents, in accordance with the Quality Management Regulations for Outpatient (Emergency) Diagnosis and Treatment Information Pages (Trial), reference to the framework of the World Health Organization Family of International Classifications (WHO-FICs), the data framework and content of rehabilitation outpatient medical records were determined, and the data standards were discussed. ResultsThis study constructed a data framework for rehabilitation outpatient medical records, including four main components: patient basic information, visit process information, diagnosis and treatment information, and cost information. Three major reference classifications of WHO-FICs, International Classification of Diseases, International Classification of Functioning, Disability and Health, and International Classification of Health Interventions,were used to establish diagnostic standards and standardized terminology, as well as coding disease diagnosis, functional description, functional assessment, and rehabilitation interventions, to improve the quality of data reporting, and level of quality control in rehabilitation. ConclusionThe structuring and standardization of rehabilitation outpatient medical records are the foundation for sharing of rehabilitation data. The using of the three major classifications of WHO-FICs is valuable for the terminology and coding of disease diagnosis, functional description and assessment, and intervention in rehabilitation outpatient medical records, which is significant for sharing and interconnectivity of rehabilitation outpatient data, as well as for optimizing the quality and safety of rehabilitation medical services.
3.Structure, content and data standardization of inpatient rehabilitation medical record summary sheet
Haiyan YE ; Qing QIN ; Ye LIU ; Yifan TIAN ; Yingxin ZHANG ; Yaru YANG ; Zhongyan WANG ; Meng ZHANG ; Xiaoxie LIU ; Yanyan YANG ; Bin ZENG ; Mouwang ZHOU ; Yuxiao XIE ; Guangxu XU ; Jiejiao ZHENG ; Mingsheng ZHANG ; Xiangming YE ; Fubiao HUANG ; Qiuchen HUANG ; Yiji WANG ; Di CHEN ; Zhuoying QIU
Chinese Journal of Rehabilitation Theory and Practice 2025;31(1):55-66
ObjectiveTo explore the standardization of inpatient rehabilitation medical record summary sheet, encompassing its structure, content and data standards, to enhance the standardization level of inpatient rehabilitation medical record summary sheet, improve data reporting quality, and provide accurate data support for medical insurance payment, hospital performance evaluation, and rehabilitation discipline evaluation. MethodsBased on the relevant specifications of the National Health Commission's Basic Norms for Medical Record Writing, Specifications for Sharing Documents of Electronic Medical Records, and Quality Management and Control Indicators for Inpatient Medical Record Summary Sheet (2016 Edition), this study analyzed the structure and content of the inpatient rehabilitation medical record summary sheet. The study systematically applied the three major reference classifications of the World Health Organization Family of International Classifications, International Classification of Diseases (ICD-10/ICD-11, ICD-9-CM-3), International Classification of Functioning, Disability and Health (ICF), and International Classification of Health Interventions (ICHI Beta-3), for disease diagnosis, functional description and assessment, and rehabilitation intervention, forming a standardized terminology system and coding methods. ResultsThe inpatient rehabilitation medical record summary sheet covered four major sections: inpatient information, hospitalization information, diagnosis and treatment information, and cost information. ICD-10/ICD-11 were the standards and coding tools for admission and discharge diagnoses in the inpatient rehabilitation medical record summary sheet. The three functional assessment tools recommended by ICD-11, the 36-item version of World Health Organization Disability Assessment Schedule 2.0, Brief Model Disability Survey and Generic Functioning domains, as well as ICF, were used for rehabilitation functioning assessment and the coding of outcomes. ICHI Beta-3 and ICD-9-CM-3 were used for coding surgical procedures and operations in the medical record summary sheet, and also for coding rehabilitation intervention items. ConclusionThe inpatient rehabilitation medical record summary sheet is a summary of the relevant content of the rehabilitation medical record and a tool for reporting inpatient rehabilitation data. It needs to be refined and optimized according to the characteristics of rehabilitation, with necessary data supplemented. The application of ICD-11/ICD-10, ICF and ICHI Beta-3/ICD-9-CM-3 classification standards would comprehensively promote the accuracy of inpatient diagnosis of diseases and functions. Based on ICD-11 and ICF, relevant functional assessment result data would be added, and ICHI Beta-3/ICD-9-CM-3 should be used to code rehabilitation interventions. Improving the quality of rehabilitation medical records and inpatient rehabilitation medical record summary sheet is an important part of rehabilitation quality control, and also lays an evidence-based data foundation for the analysis and application of inpatient rehabilitation medical record summary sheet.
4.Construction of a Diagnostic Model for Traditional Chinese Medicine Syndromes of Chronic Cough Based on the Voting Ensemble Machine Learning Algorithm
Yichen BAI ; Suyang QIN ; Chongyun ZHOU ; Liqing SHI ; Kun JI ; Chuchu ZHANG ; Panfei LI ; Tangming CUI ; Haiyan LI
Journal of Traditional Chinese Medicine 2025;66(11):1119-1127
ObjectiveTo explore the construction of a machine learning model for the diagnosis of traditional Chinese medicine (TCM) syndromes in chronic cough and the optimization of this model using the Voting ensemble algorithm. MethodsA retrospective analysis was conducted using clinical data from 921 patients with chronic cough treated at the Respiratory Department of Dongfang Hospital, Beijing University of Chinese Medicine. After standardized processing, 84 clinical features were extracted to determine TCM syndrome types. A specialized dataset for TCM syndrome diagnosis in chronic cough was formed by selecting syndrome types with more than 50 cases. The synthetic minority over-sampling technique (SMOTE) was employed to balance the dataset. Four base models, logistic regression (LR), decision tree (dt), multilayer perceptron (MLP), and Bagging, were constructed and integrated using a hard voting strategy to form a Voting ensemble model. Model performance was evaluated using accuracy, recall, precision, F1-score, receiver operating characteristic (ROC) curve, area under the curve (AUC), and confusion matrix. ResultsAmong the 921 cases, six syndrome types had over 50 cases each, phlegm-heat obstructing the lung (294 cases), wind pathogen latent in the lung (103 cases), cold-phlegm obstructing the lung (102 cases), damp-heat stagnating in the lung (64 cases), lung yang deficiency (54 cases), and phlegm-damp obstructing the lung (53 cases), yielding a total of 670 cases in the specialized dataset. High-frequency symptoms among these patients included cough, expectoration, odor-induced cough, throat itchiness, itch-induced cough, and cough triggered by cold wind. Among the four base models, the MLP model showed the best diagnostic performance (test accuracy: 0.9104; AUC: 0.9828). Compared with the base models, the Voting ensemble model achieved superior performance with an accuracy of 0.9289 on the training set and 0.9253 on the test set, showing a minimal overfitting gap of 0.0036. It also achieved the highest AUC (0.9836) in the test set, outperforming all base models. The model exhi-bited especially strong diagnostic performance for damp-heat stagnating in the lung (AUC: 0.9984) and wind pathogen latent in the lung (AUC: 0.9970). ConclusionThe Voting ensemble algorithm effectively integrates the strengths of multiple machine learning models, resulting in an optimized diagnostic model for TCM syndromes in chronic cough with high accuracy and enhanced generalization ability.
5.Mendelian Randomization Analysis of Correlation Between Interleukin and Risk of Gynecological Tumors
Xinying ZHOU ; Hu ZHANG ; Haiyan DAI
Cancer Research on Prevention and Treatment 2025;52(6):511-519
Objective To investigate the relationship between different interleukins (ILs) and gynecological tumors, including cervical cancer, endometrial cancer, and uterine leiomyoma using two-sample Mendelian randomization (MR) analysis. Methods IL and gynecological tumor data were obtained from European populations by using the IEU OpenGWAS open database. Two-sample MR analysis was applied, different interleukins were used as exposure factors, significant SNP in GWAS data were selected as instrumental variables, and the instrumental variables were independent of each other. The risk of three kinds of gynecological tumors was analyzed separately to explore the causal relationship between ILs predicted by genes and outcome indicators. The TwoSampleMR package in R language (4.3.1) software was used for statistical analysis. MR analysis was performed using inverse variance weighted, MR Egger regression, weighted median, simple mode, and weighted mode methods. Results IL-18 receptor 1 (P=0.039) and IL-24 (P=0.025) were negatively correlated with the risk of cervical cancer. IL-4 (P=0.040), IL-21 (P=0.026), and IL-37 (P=0.027) were positively correlated with the risk of endometrial cancer. IL-15 receptor subunit alpha (P=0.005) was negatively correlated with the risk of endometrial cancer. IL-17A (P=0.005) and IL-37 (P=0.018) were negatively correlated with the risk of uterine leiomyoma. IL-21 (P=0.035) was positively correlated with the risk of uterine leiomyoma. Conclusion Genetically predicted IL-4, IL-15Rα, IL-17A, IL-18R1, IL-21, IL-24, and IL-37 are causally associated with the risk of three gynecological tumors. Further exploration of the molecular mechanism of ILs in gynecological tumors may provide potential therapeutic targets for the treatment of gynecological tumors.
6.Clinical Efficacy of Modified Yigongsan Combined with Multi-enzyme Tablets and Bifidobacterium Triple Live Powder in Treatment of Infantile Anorexia with Spleen-Stomach Qi Deficiency Syndrome
Haiyan WANG ; Xiaojing LYU ; Li ZHAO ; Yaqian ZHOU ; Jiaqi CUI ; Yao CUI
Chinese Journal of Experimental Traditional Medical Formulae 2024;30(11):150-155
ObjectiveTo observe the clinical efficacy of modified Yigongsan combined with multi-enzyme tablets and bifidobacterium triple live powder on infantile anorexia with spleen-stomach Qi deficiency syndrome. MethodA total of 112 infantile patients anorexia with spleen-stomach Qi deficiency syndrome treated at Hebei Provincial Hospital of Traditional Chinese Medicine from January 2022 to June 2023 were enrolled and divided into a control group and an observation group, with 56 cases in each group, according to a random number table. Children in the control group were treated with multi-enzyme tablets and Bifidobacterium triple live powder, while those in the observation group were treated with modified Yigongsan in addition to the treatment in the control group. During the study, one case dropped out in the control group and two cases dropped out in the observation group. The clinical efficacy of the two groups of children was compared, including changes in traditional Chinese medicine (TCM) syndrome scores (main symptoms, secondary symptoms, tongue, and pulse), time to restore normal food intake, and increase in body weight. Changes in calcium, iron, zinc levels, hemoglobin, and albumin levels before and after treatment, as well as changes in gastrointestinal hormones such as gastrin and motilin, vasoactive intestinal peptide, somatostatin, neuropeptide Y, orexin, and leptin, were observed. The occurrence of adverse reactions in the two groups of children during the study was also recorded. ResultThe total effective rate of children in the control group after treatment was 85.19% (46/54), while that in the observation group was 98.15% (53/54) (χ2 =5.939, P<0.05). Compared with the control group, the time for food intake to return to normal in the observation group was shorter, and the increase in body weight was greater (P<0.05). Compared with the results before treatment, the TCM syndrome scores (main symptoms, secondary symptoms, tongue, and pulse) in both groups of children significantly decreased, while the levels of calcium, iron, zinc, hemoglobin, albumin, gastrin, motilin, neuropeptide Y, and orexin increased, and the levels of vasoactive intestinal peptide, somatostatin, and leptin decreased (P< 0.01). Compared with the control group after treatment, the improvement in the above indicators in the observation group was more significant (P<0.01). The incidence of adverse reactions in the two groups of children during the treatment period was similar, and the difference was not statistically significant. ConclusionModified Yigongsan combined with multi-enzyme tablets and Bifidobacterium triple live powder is highly effective in treating infantile anorexia (spleen-stomach Qi deficiency syndrome). After treatment, symptoms of the children were improved,appetite and food intake increased, gastrointestinal function was improved, body weight increased, and adverse reactions were few, indicating that the treatment was safe and reliable.
7.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
8.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
9.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
10.Impact of the LAmbre device on left atrial appendage adjacent structures and left atrium
Zhengdan GE ; Dehong KONG ; Zhenyi GE ; Chunqiang HU ; Xiaochun ZHANG ; Haiyan CHEN ; Daxin ZHOU ; Xianhong SHU ; Cuizhen PAN
Chinese Journal of Ultrasonography 2024;33(2):142-150
Objective:To explore the effects of the LAmbre device and mitral annulus(MA), as well as left atrium(LA) in patients with non-valvular atrial fibrillation(NVAF) after left atrial appendage closure (LAAC) using real-time-three-dimensional transesophageal echocardiography (3D TEE).Methods:Fity-six consecutive patients who underwent LAAC with the LAmbre device in Zhongshan Hospital of Fudan University from June 2019 to March 2023 were retrospectively enrolled, with no or less than moderate mitral regurgitation (MR). All patients underwent pre-operative and follow-up two-and three-dimensional transesophageal echocardiography (2D TEE, 3D TEE) at 60 days after the operation. The quantitative parameters of MA and LA were obtained by offline analysis using QLab 13.0 (Philips Healthcare, Andover, MA). Importantly, mitral annular measurements were made at seven time points throughout the cardiac cycle: early diastole, mid-diastole, late diastole, mitral valve closure, early systole, mid-systole, and late systole, which facilitates constructing the dynamic model of MA to assess the annular morphology and dynamics.Results:The values of AP diameter (APD), AL-PM diameter (ALPMD), 3D annulus circumference (3DAC), 3D annulus area (3DAA) decreased significantly compared with pre-operative values at all time points of the cardiac cycle (all P<0.05), while non-planar angle (NPA) and AH/CD were not apparently changed (all P>0.05 ). Throughout the cardiac cycle, MA showed regular changes, gradually increased in systole with the saddle shape deepened, and gradually decreased in diastole with the saddle shape shallowed.During systole, there was an increase in the rate of change of AP in MA [pre-operative (3.01±2.64)%, post-operative (3.81±3.51)%, P=0.037] after LAAC, with no significant difference in the rate of change of ALPM, 3DAC, and 3DAA.Meanwhile, we observed an evident reduction in LA minimal volume (LAVmin) [pre-operative (78.36±25.16)ml, post-operative (70.73±22.78)ml, P=0.004] and an obvious increase in LA ejection function [pre-operative (22.88±10.09)%, post-operative (31.41±12.28)%, P<0.05] during follow-up. Conclusions:3D TEE can accurately assess the impact of LAAC on the MA and LA. The LAmbre device can affect the morphology of MA, as well as the structure and function of LA, while the change of the dynamics of MA is not so prominent.

Result Analysis
Print
Save
E-mail