1.Analysis of iodine nutritional status in water-borne high iodine areas of Shandong Province in 2021
Ruijuan GUO ; Jiakun WANG ; Na LIANG ; Xue ZHANG ; Fang YANG ; Haijie LIU ; Wen JIANG
Chinese Journal of Endemiology 2024;43(8):652-656
Objective:To investigate the popularization of non-iodized salt among residents in water-borne high iodine areas and the iodine nutrition status of key populations in Shandong Province.Methods:In 2021, monitoring was conducted on a county-by-county basis in 47 counties (cities, districts, hereinafter referred to as counties) in 9 cities of Shandong Province, in accordance with the newly designated high iodine areas in the "Definition of Water Source High Iodine Areas and High Iodine Disease Areas" (GB/T 19380-2016) and historical high iodine areas. In each monitoring county, administrative villages with a median water iodine level greater than 100 μg/L were sorted by water iodine value, and a systematic sampling method was used to select 5 administrative villages as monitoring sites to investigate the water improvement situation and the iodine level of residents' drinking water. Totally 40 non boarding students aged 8 to 10 from one primary school and 20 pregnant women were selected in each village location to collect household edible salt samples and random urine samples for testing salt iodine and urine iodine levels, and the B-ultrasound method was used for thyroid examination in children.Results:A total of 364 high iodine administrative villages had been monitored, all of which had completed water improvement with a water improvement rate of 100.0%. The median iodine content in residential drinking water was 20.3 μg/L, ranging from 0.1 to 869.1 μg/L; and 11 464 edible salt samples were collected from residents' homes, with a non-iodized salt rate of 82.7% (9 481/11 464). A total of 9 197 urine samples from children and 2 335 urine samples from pregnant women were tested, with median urinary iodine levels of 219.0 and 139.0 μg/L, respectively. A total of 9 197 children were examined for thyroid, with 262 cases detected and a goiter rate of 2.8%.Conclusions:The rate of non-iodized salt in high iodine areas of Shandong Province still needs to be improved. Children's iodine nutrition is above the appropriate level, while pregnant women are at an iodine deficiency level.
2.Application of newly designed modular hinged ankle prosthesis in the reconstruction of defect after surgical treatment of malignant tumor at the distal tibia
Jun WANG ; Yi YANG ; Haijie LIANG ; Zhiye DU ; Jie ZANG ; Ran WEI ; Xiaodong TANG ; Wei GUO
Chinese Journal of Orthopaedics 2023;43(13):869-877
Objective:To investigate the outcome of surgical treatment of malignant tumor at the distal tibial after reconstruction with modular hinged ankle prosthesis.Methods:The data of 9 patients with malignant tumor at the distal tibia at Musculoskeletal Tumor Center of PKUPH from June 2020 to November 2021 were analyzed retrospectively. They were male patients with age of 17 (14, 24) years (range 11-56 years). There were five tumors at the left sides and four at the right sides. There were eight patients with osteosarcoma who received the neo-chemotherapy. Among eight osteosarcomas, one was Enneking IIA and seven Enneking IIB. Furthermore, there was only one patient with renal carcinama and with solitary metastatic lesion at the distal tibia. After the resection of tumor at the distal tibia, talus cartilage was removed and talus component was fixed by lag screws. The proper tibia component was used to restore the defect of tibia and the reduction of tibia and talus components were performed. The following clinical data were collected: baseline demographic features, surgical and follow-up data. The baseline demographic features included gender, age, side, lung or/and other metastasis at initial diagnosis, Enneking stage or systematic progression for renal carcinama, histological type. The surgical data included: surgery time, blood loss, length of bone involved by the tumor, prosthesis type. Monitoring data was also recorded: complications (ankle pain when loading, talar collapse, component loosing, infection and wound dehiscence), local recurrence, pulmonary and systematic metastasis, radiological image and the function at the last follow-up (MSTS and VAS evaluation).Results:Among these nine patients, the average blood loss was 245.6±103.9 ml (range 100-400 ml) and the mean surgery time was 178.9±56.9 mins (range 120-300 min). No patient was lost during the follow-up period and the average follow-up was 21.4±5.6 months (range 12.5-27.2 months). The excision length of tibia was 14 (11, 17) cm (range 11-28 cm). There were one case with 2# prosthetic base, three cases with 3# and five cases with 4#. Five had cement fixation of prosthetic stem and four had the pressing fixation. No pulmonary and other organ metastasis occurred among eight patients with osteosarcoma and one patient with distal tibia matastasis of renal carcinama. One patient with OShad the local recurrence and received the resection. One sustained the deep infection after four months and received the removal of prosthesis and spacer implant. At the final follow-up, except one with deep infection and receiving the removal of prosthesis and spacer implant, eight patients were assessed for the function. The average MSTS was 97.1%±3.3% (range 93%-100%). The VAS of all patients was 0. One patient with prosthesis removal had no functional evaluation. At the final follow-up, all patients walked without crutch. No breakage and loosening of prosthetic stem, talar collapse, prosthetic sinking and ankle pain occurred at the final follow-up.Conclusion:The early satisfactory outcome can be obtained for patients with segmental defect after resection of malignant tumor at the distal tibia, who received the newly designed modular hinged ankle prosthesis. Meanwhile, it's worth promoting in the reconstruction of large segmental defect at the distal tibia.
3.Application of three-dimensional printed endoprosthesis for reconstruction after metaphysis-involved intercalary tumor resection
Ran WEI ; Haijie LIANG ; Jun WANG ; Yi YANG ; Tao JI ; Xiaodong TANG ; Wei GUO
Chinese Journal of Orthopaedics 2023;43(14):969-977
Objective:To describe the design, manufacture and use of three-dimensional (3D)-printed endoprosthesis for reconstruction after metaphysis-involved intercalary tumor resection and to evaluate its outcome.Methods:Forty-three patients who received metaphysis-involved intercalary tumor resection followed by 3D-printed endoprosthetic reconstruction in Musculoskeletal Tumor Center, Peking University People's Hospital between January 2018 and December 2021 were retrospectively reviewed. There were 25 males and 18 males with an average age of 20.1±15.2 years (range, 4-58 years). The pathological diagnosis included 24 cases of osteosarcomas, 6 cases of Ewing sarcomas, 5 cases of chondrosarcomas, 2 cases of pleomorphic undifferentiated sarcomas, 3 cases of soft-tissue sarcomas (liposarcoma, synovial sarcoma, malignant peripheral nerve sheath tumor for each) and 3 others (adamantinoma, recurrent aneurysmal bone cyst and recurrent osteofibrous dysplasia for each). The tumors located at femur in 25 patients (58%), including 14 lesions involving distal femoral metaphysis and 11 lesions involving both proximal and distal metaphysis; the tumors located at tibia in 11 patients (26%), including 4 lesions involving distal tibial metaphysis, 5 lesions involving proximal tibial metaphysis and 2 lesions involving both proximal and distal tibial metaphysis; the tumors located at humerus in 7 patients (16%), including 1 lesion involving distal humeral metaphysis, 3 lesions involving proximal humeral metaphysis and 3 lesions involving both proximal and distal humeral metaphysis. The endoprosthesis was designed in a semi-modular fashion and consisted of three parts: a diaphysis-fixing component, a semi-modular lap joint component, and a custom-made 3D-printed metaphysis-fixing component which was designed as two types with 3D-printed porous bone-contacting surfaces according to the osteotomy plane (Type I on meta-diaphyseal region, Type II on meta-epiphyseal region). The functional outcome was assessed using Musculoskeletal Tumor Society (MSTS) 93 system.Results:All surgeries were accomplished sucessfully. The median resection length and the distance from osteotomy plane to adjacent joint was 16.0 (13.0, 22.0) cm and 4.5 (3.5, 6.0) cm, respectively. 59 metaphysis-fixing components were installed in 43 patients. Type I components were used in single and dual ends of endoprosthesis in 12 and 6 cases respectively. Type II components were used in single and dual ends in 15 and 5 cases respectively. Hybrid endoprosthesis with Type I and II components were used in 5 cases. The mean follow-up time was 26.0 (17, 37) months (range, 12-54 months). The mean MSTS 93 score was 29.0 (28.0, 30.0) points (range, 21-30 points). Implant failures were found in 5 patients, including 2 cases of aseptic loosening (loosening was observed in the cementing diaphysis-fixing stems while no evidence of loosening in metaphysis-fixing components) and 3 cases of local tumor progression. The 2-year implant survival rate was 90.3% (95% CI: 0.81, 0.99). Conclusion:Using 3D-printed intercalary endoprosthesis for reconstruction after intercalary resection of metaphysis-involved bone tumor shows satisfactory functional outcome and implant survival. Moreover, by assembling endoprosthetic components according to the different osteotomy plane, the semi-modularized endoprosthesis also provids a comprehensive and individualized reconstruction for patients with metaphysis-involved intercalary tumor.
4.Efficacy of 3D-printed segmental tumor prosthesis for reconstruction of bone defects after resection of weight-bearing long bone tumors in the lower extremity
Jichuan WANG ; Haijie LIANG ; Zhiqing ZHAO ; Yi YANG ; Wei GUO ; Xiaodong TANG
Chinese Journal of Orthopaedics 2023;43(20):1372-1378
Objective:To investigate the efficacy of 3D-printed segmental tumor prosthesis for reconstruction of bone defects after resection of weight-bearing long bone tumors in the lower extremity.Methods:A total of 71 patients who received 3D-printed segmental metal tumor prosthesis for reconstruction of bone defects from August 2015 to August 2021 at the Musculoskeletal Tumor Center of Peking University People's Hospital were retrospectively analyzed. There were 40 males and 31 females, aged 23.08±18.52 years (range, 10-63 years). Tumor types: 49 cases of osteosarcoma, 9 cases of Ewing sarcoma, 3 cases of chondrosarcoma, 3 cases of synovial sarcoma, 2 cases of pleomorphic undifferentiated sarcoma, 2 cases of rhabdomyosarcoma, 2 cases of bone metastasis, and 1 case of low-grade malignant tumor of mesenchymal origin. Ennecking stage of bone tumor: 19 cases of stage III, 52 cases of stage IIb. Tumor location: femur 43 cases, tibia 28 cases. Operative time, intraoperative bleeding, patient survival and postoperative complications were recorded. Kaplan-Meier curves for prosthetic survival were plotted. The osseointegration at the prothesis-bone interface was determined by combination of clinical presentation and imaging. Limb function scores were evaluated using the Musculoskeletal Tumor Society (MSTS) 93 function score.Results:All 71 patients successfully completed the operation and were followed up for 24.4±13.2 months (range, 6.6-65.4 months). At the last follow-up, 50 patients survived without disease, 12 survived with the disease, and the remaining 9 cases died with disease. A total of 11 cases showed prosthesis failure, including 1 case of aseptic loosening, 3 cases of screw breakage or periprosthetic fracture, 1 case of periprosthetic infection, and 6 cases of tumor progression involving the prosthesis. The Kaplan-Meier curve showed that the 1-year, 3-year and 5-year survival rates of prosthesis were 94.2%±2.8%, 86.1%±4.7% and 79.5%±9.2%, respectively. 62 patients received functional follow-up, and the MSTS93 functional score at the last follow-up was 23.95±5.03 points (range, 10-30 points), with an excellent rate of 90% (56/62). The score of femoral prosthesis was 24.63±4.97 points (range, 13-30 points) and the score of tibial prosthesis was 23.29±5.09 points (range, 10-29).Conclusion:3D-printed segmental tumor prosthesis for reconstruction of bone defect after resection of weight-bearing long bone tumors in the lower extremity has a relative high survival rate, a low incidence of prosthetic complications, and a good recovery of function, and it can be used as an option for the postoperative reconstruction of bone tumors in weight-bearing bones of the lower extremity.
5.Arthrodesis reconstruction of distal tibia by 3D-printed porous prosthesis after malignant tumor resection
Tianli NIU ; Yi YANG ; Haijie LIANG ; Zhiye DU ; Jie ZANG ; Xingyu LIU ; Wei GUO
Chinese Journal of Orthopaedics 2022;42(5):272-280
Objective:To evaluate the safety and short-term clinical postoperative functional outcomes of a novel 3D-printed porous prosthesis of the distal tibia for the bone defect after tumorectomy.Methods:From December 2017 to December 2019, a total of eight patients diagnosed with malignant bone tumor of the distal tibia were enrolled in this study. All cases received standard preoperative chemotherapy, after which osteosarcoma resection was performed and ankle arthrodesis was reconstructed using a 3D-printed prosthesis developed by our medical center. The contact surface between the distal part of the prosthesis and the talus is a 3D-printed porous surface, which is conducive to ankle fusion. The length of the prosthesis is adjusted by the conical mounting part of the modular prosthesis. The proximal part of the prosthesis can be fixed either biologically or with bone cement. At postoperative follow-up, the function of the fused ankle was assessed by radiographs and the monthly Musculoskeletal Tumor Society (MSTS) score.Results:Of the 8 patients, 5 were male and 3 were female, aged 8-29 years (mean 16.1±7.4 years), including 7 osteoblastic osteosarcomas and 1 telangiectatic osteosarcoma. Among the procedures, the mean length of osteotomy was 16 cm (11-20 cm). The method of fixation of the proximal part of the prosthesis included one case with 3D-printing of trabecular metal bone, one case with autogenous fibular graft, and six cases with bone cement. All patients were followed up for 7-39 months (mean 15.6±10.5 months). The distal prosthesis and talus were completely fused in all cases. The mean fusion duration was 4.3±0.7 months. The mean MSTS score was 84.2%±3.0% (mean 80%-90%). No tumor recurrence, wound complications, or prosthesis loosening were observed during the follow-up period.Conclusion:The novel 3D-printed distal tibial prosthesis is a safe and effective technique for reconstruction of a massive bone defect after tumorectomy of a malignant bone tumor, with high fusion rate, few complications, and satisfactory postoperative function.
6.Design and function evaluation of 3D-printed hemi-elbow-arthroplastic total humeral prosthesis
Liang YAN ; Sen DONG ; Haijie LIANG ; Xiaodong TANG ; Taiqiang YAN ; Jie ZANG ; Zhiye DU ; Wei GUO ; Yi YANG
Cancer Research and Clinic 2022;34(5):346-351
Obiective:To investigate the design, the key points of surgery and the outcome of short-term follow-up of hemi-elbow-arthroplastic bionic total humeral prosthesis by using 3D-print.Methods:The clinical data of 8 patients with humerus malignant tumor who underwent total humerus resection and a 3D-printed auxiliary hemi-elbow-arthroplastic total humeral prosthesis replacement from March 2018 to March 2020 at Peking University People's Hospital were retrospectively analyzed. The operative data, oncological outcome, complication profiles of prosthesis and functional status of all 8 patients were also analyzed. There were 3 males and 5 females with a mean age of 5-37 years. Histological diagnosis included 5 cases of osteosarcoma, 2 cases of Ewing's sarcoma and 1 case of chondrosarcoma.Results:The time for production of the prosthesis was (9.8±2.7) d, the operation time was (209±23) min and intraoperative hemorrhage was (569±173) ml. All the prostheses were implanted successfully and no patients experienced intraoperative complications. While 2 patients had postoperative complications, 1 case of temporary palsy of radial nerve and 1 case of local recurrence. LARS artificial ligament or hernia patch was used to reconstruct joint capsule and tendon-ligament attached around the elbow and shoulder joint. The flexion and extension of the elbow was (118±15)° (100-140°) and (11±9)° (0-25°), and the abduction and anteflexion of the shoulder was (28±12)° (15-50°) and (26±9)° (15-40°), respectively. The postoperative Musculoskeletal Tumor Society (MSTS)-93 scale score was (24.1±1.5) scores. The median follow-up time was 17 months (12-32 months), 7 patients had disease-free survival and 1 patient survived with tumor.Conclusions:The novel 3D-printed total humeral prosthesis with hemi-elbow-arthroplasty has a good perioperative safety, which is effective in restoring the function of elbow joint, solving the problem of stress concentration of ulnar marrow lever of total elbow joint prosthesis and lowering long-term wear rate and loosening rate of prosthesis.
7.Reconstruction with a bionic knee megaprosthesis after resection of a distal femoral osteosarcoma in children
Wei GUO ; Haijie LIANG ; Yi YANG ; Zhiye DU ; Jie ZANG ; Xiaodong TANG ; Tao JI ; Rongli YANG ; Taiqiang YAN
Chinese Journal of Orthopaedics 2021;41(4):201-210
Objective:We designed and applied a novel, bionic megaprosthesis for distal femur, which substituted the hinged articulation with an artificial ligament and a constrained tibial insert in order to maintain articular stability and reduce stress and the risks of wearing, loosening and breakage.Methods:We reviewed the cases of distal femoral osteosarcoma in children population who were initially treated in our center during 2019. Twelve cases of bionic distal femoral prosthesis (bionic group) and 21 cases of fixed-hinge distal femoral prosthesis (control group) were included. In the bionic group, there were six female and six male with the mean age as 8.8±2.6 y. One patient had pathological fracture. Staging according to Enneking system included 1 case of stage IIA, 10 cases of stage IIB and 1 case of stage III. In the control group, there were seven female and fourteen male with the mean age as 8.6±2.2 y. Pathological fracture was seen in three cases. Staging included 15 cases of stage IIB and 6 cases of stage III.We investigated the peri-operative safety, oncological outcome, complication profiles and post-operative functional status of the bionic prosthesis by comparing the baseline data, operative data, and oncological and prosthetic outcomes between the two groups.Results:The two groups were comparable in terms of baseline data including gender, age, height, weight and onset duration, and operative data including duration of operation (126.7±27.9 min vs 143.3±38.9 min, P=0.203), intra-operative hemorrhage (162.5±212.3 ml vs 247.6±175.6 ml, P=0.224) and duration of wound drainage (6.3±2.4 d vs 6.4±3.4 d, P=0.908). The mean follow-up duration of bionic group was 16.0±4.7 months, during which time three patients had systemic progression and one of them died of disease. Another patient had local recurrence and subluxation of the prosthesis that was treated by amputation. Subluxation might be related to the huge tumor mass and excessive resection of the quadriceps femoris. As for the control group, the mean follow-up duration was 12.7±4.5 months. Three patients had systemic progression and all patients were still alive by last follow-up. Local recurrence was seen in two patients and was treated by excision. No prosthetic complications were seen in the control group. The averaged range of motion (ROM) was greater in the bionic group than that in the control group (120.6°±13.6° vs 92.0°±7.7°, P<0.05), but the MSTS 93 scores were similar between groups (29.1±0.9 vs 29.5±0.6, P=0.337). Conclusion:Compared with the fixed-hinge distal femoral prosthesis, the bionic prosthesis had good peri-operative safety, did not increase the risks of prosthetic complications, and could achieve a better range of motion and a similar functional status based on the results of short-term follow-up.
8.The prevention and management of approach-specific complications of abdominal aortic balloon occlusion in pelvic and sacral surgery
Zhiqing ZHAO ; Sen DONG ; Jingtian SHI ; Haijie LIANG ; Taiqiang YAN ; Wei GUO ; Rongli YANG ; Xiaodong TANG ; Xuemin ZHANG
Chinese Journal of Surgery 2021;59(9):737-743
Objective:To investigate the causes,prevention and treatment of femoral artery puncture related complications caused by the application of resuscitative endovascular balloon occlusion of the aorta (REBOA) in the resection of pelvic and sacral tumors.Methods:Clinical data of 23 patients with femoral artery puncture related complications who received REBOA in the resection of pelvic and sacral tumors from August 2010 to August 2018 at the Musculoskeletal Tumor Center,Peking University People′s Hospital were retrospectively analyzed.There were 8 males and 15 females,with the age of (37.0±16.2) years (range:15 to 65 years).Arterial access via the Seldinger technique for REBOA was obtained in the right common femoral artery of 18 cases,and in the left of 6 cases.An arterial sheath with a diameter of 11 to 12 F(1 F≈0.33 mm) was used for the patient.The occurrence and treatment of postoperative complications were analyzed.Results:Acute femoral arterial thrombosis occurred in 18 patients,which was managed by open repair 48 hours postoperatively.Among the 349 patients admitted before 2015 who received hemostasis by compression after femoral artery sheath removal,12 patients (3.4%) developed acute femoral artery thrombosis.While the 476 patients admitted after 2015 who used a percutaneous suture device to close the femoral artery wound,6 patients (1.3%) developed acute femoral artery thrombosis.One case of retroperitoneal hematoma and 1 case of femoral pseudoaneurysm were found and surgically fixed.Postoperative follow-up was (40±18) months (range:13 to 108 months).Three cases with chronic lower extremity ischemia were confirmed by Doppler ultrasonography during 1 to 5 years follow-up.Two of them had minimal symptoms and denied further treatment,while the other one received femoral-femoral artery bypass surgery to restore distal flow for pain and numbness relief.Conclusions:Acute femoral arterial thrombosis is the most common femoral artery puncture.Technique refinement of REBOA,the use of percutaneous suture device and close follow-up can reduce the approach-specific complications,and help to detect and treat the complications timely,which may popularize the clinical application of REBOA.
9.The prevention and management of approach-specific complications of abdominal aortic balloon occlusion in pelvic and sacral surgery
Zhiqing ZHAO ; Sen DONG ; Jingtian SHI ; Haijie LIANG ; Taiqiang YAN ; Wei GUO ; Rongli YANG ; Xiaodong TANG ; Xuemin ZHANG
Chinese Journal of Surgery 2021;59(9):737-743
Objective:To investigate the causes,prevention and treatment of femoral artery puncture related complications caused by the application of resuscitative endovascular balloon occlusion of the aorta (REBOA) in the resection of pelvic and sacral tumors.Methods:Clinical data of 23 patients with femoral artery puncture related complications who received REBOA in the resection of pelvic and sacral tumors from August 2010 to August 2018 at the Musculoskeletal Tumor Center,Peking University People′s Hospital were retrospectively analyzed.There were 8 males and 15 females,with the age of (37.0±16.2) years (range:15 to 65 years).Arterial access via the Seldinger technique for REBOA was obtained in the right common femoral artery of 18 cases,and in the left of 6 cases.An arterial sheath with a diameter of 11 to 12 F(1 F≈0.33 mm) was used for the patient.The occurrence and treatment of postoperative complications were analyzed.Results:Acute femoral arterial thrombosis occurred in 18 patients,which was managed by open repair 48 hours postoperatively.Among the 349 patients admitted before 2015 who received hemostasis by compression after femoral artery sheath removal,12 patients (3.4%) developed acute femoral artery thrombosis.While the 476 patients admitted after 2015 who used a percutaneous suture device to close the femoral artery wound,6 patients (1.3%) developed acute femoral artery thrombosis.One case of retroperitoneal hematoma and 1 case of femoral pseudoaneurysm were found and surgically fixed.Postoperative follow-up was (40±18) months (range:13 to 108 months).Three cases with chronic lower extremity ischemia were confirmed by Doppler ultrasonography during 1 to 5 years follow-up.Two of them had minimal symptoms and denied further treatment,while the other one received femoral-femoral artery bypass surgery to restore distal flow for pain and numbness relief.Conclusions:Acute femoral arterial thrombosis is the most common femoral artery puncture.Technique refinement of REBOA,the use of percutaneous suture device and close follow-up can reduce the approach-specific complications,and help to detect and treat the complications timely,which may popularize the clinical application of REBOA.
10.Clinical and genetic analysis of a patient with 17-hydroxylase/17,20-lyase deficiency.
Yu ZENG ; Libin MEI ; Lei LIANG ; Xuemei HE ; Haijie GAO ; Shaobin LIN ; Lingling HUANG ; Ping LI
Chinese Journal of Medical Genetics 2020;37(9):997-1000
OBJECTIVE:
To explore the clinical and genetic characteristics of a patient with 17-hydroxylase/17,20-lyase deficiency.
METHODS:
The patient was infertile without contraception. Laboratory examination showed her chromosomal karyotype to be 46, XX. DNA sequencing was performed to detect variants of CYP17A1 gene in the patient and her family members.
RESULTS:
Sanger sequencing revealed that the patient has carried homozygous variant c.1486C>T in the exon 8 of the CYP17A1 gene, which resulted in substitution of arginine by cysteine (p.Arg496Cys). Her family members were all heterozygotes for the same variant.
CONCLUSION
Homozygous variant of the CYP17A1 gene c.1486C>T probably underlay the 17-hydroxylase deficiency in this patient. Above finding has enabled accurate genetic counseling and prenatal diagnosis for her family.

Result Analysis
Print
Save
E-mail