1.Correlation of central corneal thickness and Goldmann applanation tonometry among Filipinos
Lat-Luna Ma Margari ; Flores John Vincent ; Guerrero Paul I
Philippine Journal of Ophthalmology 2004;29(2):79-82
		                        		
		                        			
		                        			Methods: A prospective cross-sectional study was performed among Filipino patients consulting at the General Ophthalmology Clinic of the Philippine General Hospital. They underwent a comprehensive eye examination. CCT obtained by ultrasonic pachymetry and IOP by Goldmann applanation tonometry were correlated using linear regression analysis. Factors affecting CCT measurements were analyzed by ANOVA.
Results: Two hundred twenty two eyes of 112 patients were included in the study. CCT ranged from 451.0 mm to 653.6 mm with a mean of 531.5 mm +/- 33.8 mm. There was a significant linear correlation between CCT and IOP (r=0.63). The IOP was noted to rise by 4.3 mm Hg/100 mm CCT.
Conclusion: The CCT among Filipinos is normally distributed and is comparable to the distribution obtained by metaanalysis of worldwide data. The study also found a direct correlation between CCT and IOP among Filipinos.
		                        		
		                        		
		                        		
		                        			Male
		                        			;
		                        		
		                        			 Female
		                        			;
		                        		
		                        			 Aged 80 and over
		                        			;
		                        		
		                        			 Aged
		                        			;
		                        		
		                        			 Middle Aged
		                        			;
		                        		
		                        			 Adult
		                        			;
		                        		
		                        			 Young Adult
		                        			;
		                        		
		                        			 Adolescent
		                        			;
		                        		
		                        			 MANOMETRY
		                        			;
		                        		
		                        			 TONOMETRY, OCULAR
		                        			;
		                        		
		                        			 INTRAOCULAR PRESSURE
		                        			;
		                        		
		                        			 GLAUCOMA
		                        			
		                        		
		                        	
            
Result Analysis
Print
Save
E-mail